• Title/Summary/Keyword: stator current

Search Result 684, Processing Time 0.026 seconds

Decoupled Control of Doubly Fed Induction Machine Fed by SVM Matrix Converter

  • Dendouga, Abdelhakim;Abdessemed, Rachid;Bendaas, Mohamed Lokmane
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.4
    • /
    • pp.491-498
    • /
    • 2008
  • In this paper a decoupled control of a doubly-fed induction machine(DFIM) feed by a matrix converter is presented. It provides a robust regulation of the stator side active and reactive powers by the direct and quadratic components of the stator current vector, presented in a line-voltage-oriented reference frame. In this case, the stator windings are directly connected to the line grid, while the rotor windings are supplied by this later through a matrix converter controlled by a space vector modulation technique. The proposed solution is suitable for both energy generation and electrical drive applications with restricted speed variation range.

Example study of the insulation characteristic change according to the dryness condition in high voltage motor stator winding (고압전동기 고정자권선의 건조상태에 따른 절연특성 변화사례 고찰)

  • Kong, Tae-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2056-2057
    • /
    • 2008
  • This paper is purpose to understand the insulation properties of the high voltage motor stator winding according to the different dryness conditions. we carried out the three times insulation diagnosis test for the same motor stator winding. the first test object is the contaminated winding, second is the washed-out, and natural dried during the 24 hours, and the last is the heating dried in 110$^{\circ}C$ during the 48 hours. the insulation diagnosis tests are consist of the megger, the polarization index, the AC current test, the dissipation factor test and the partial discharge test, we analyzed and made a comparison of the three cases test result.

  • PDF

Auto-Detection of Stator Winding Fault of Small Induction Motor using LabVIEW (LabVIEW를 이용한 소형 유도전동기의 권선고장 자동진단)

  • Song, Myung-Hyun;Park, Kyu-Nam;Han, Dong-Gi;Woo, Hyeok-Jae
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.55 no.4
    • /
    • pp.202-206
    • /
    • 2006
  • In this paper, an auto detection method of stator winding fault of small induction motor is suggested. The Park's vector pattern which is obtained from 3-phase current signal by d-q transforming, is very good to detect winding fault. Comparing the Park's vector pattern of testing motor with its of healthy motor, the Park's vector pattern of fault motor is became an ellipse and the asymmetry is increased by the winding fault series. So for detecting the dis-symmetry, id-filtered function, Min-value, and Max-value are suggested for auto detecting. Using LabVIEW programing, 3-phase healthy motor and several kind of winding fault motors are tested and the test results are shown that the suggested method can gives us a possibility of an auto detecting winding fault.

A Speed Sensorless SPMSM Position Control System with Direct Torque Control (직접 토크제어에 의한 속도검출기 없는 SPMSM의 속도 제어 시스템)

  • Kim, Min-Ho;Kim, Nam-Hun;Kim, Dong-Hee;Kim, Min-Huei
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.277-280
    • /
    • 2001
  • This paper presents a speed sensorless implementation of digital speed control system of Surface Permanent-Magnet Synchronous Motor(SPMSM) drives with a direct torque control(DTC). The system presented are stator flux and torque observer of stator flux feedback control model that inputs are current and voltage sensing of motor terminal with estimated rotor angle for a low speed operating area, two hysteresis band controllers, an optimal switching look-up table, rotor speed estimator, and IGBT voltage source inverter by using fully integrated control software. The developed speed sensorless control system are shown a good motion control response characteristic results and high performance features using 1.0Kw purposed servo drive SPMSM.

  • PDF

Development of Continuous Monitoring System for Generator Stator Insulations (발전기 고정자 권선 절연상태의 상시 감시 시스템 개발)

  • Shin, Byoung-Chol;Hwang, Don-Ha;Kim, Yong-Joo;Kim, Jeong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2212-2214
    • /
    • 1999
  • In this paper, a novel Generator On-line Diagnosis System (GODS) is proposed. This system monitors the insulation condition of the stator winding by on-line measurements of partial discharge (PD). Sensor, such as SSC (Stator Slot Coupler) and RFCT (Radio Frequency Current Transformer) are used for PD measurement. PD signals are continuously measured and digitized with a high speed A/D converter to build the database of the generator's insulation condition. Also this system can communicate with the central monitoring system via RS-485. This helps more efficient operation and maintenance of the generator.

  • PDF

Change of Insulation Properties of Stator Coil fed by Inverter Source on Traction Motor (인버터 전원에 의한 견인전동기 고정자 코일의 절연특성 변화)

  • Jang, Dong-Uk;Park, Hyun-June;Lee, Gil-Hun;Choi, Jong-Sun;Lee, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.420-422
    • /
    • 2003
  • Aging and failure of motor insulation depend on the stresses imposed on it. The insulation life time depends on the severity of the stresses. The electrical aging by transient surge is very important to traction motor in EMU(electric multiple unit). This paper Presents the insulation characteristics of stator coil by transient surge from inverter. There are several nondestructive tests available for checking the condition of motor insulation, the probable extent of aging,. and the rate of which aging is taking pace. So the insulation characteristics of stator coil were each analyzed by measurement of leakage current, dielectric loss($tan{\delta}$), capacitance, polarization index(PI) and partial discharge. The method of diagnosis is able to analyze the aging condition and Predict the life of the traction motor in EMU.

  • PDF

Selection of Optimal Stator Flux Reference of Stator Flux-Oriented Induction Machine Drive in Field Weakening Region (약계자영역에서 유도전동기의 고정자자속 기준 제어를 위한 최적 기준자속 선정방법)

  • Sin, Myeong-Ho;Hyeon, Dong-Seok;Jo, Sun-Bong
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.7
    • /
    • pp.494-499
    • /
    • 2000
  • In a conventional stator flux-oriented(SFO) induction machine drive system, the field weakening method is to vary flux reference in proportion to the inverse of the rotor speed. This paper investigates that maximum torque capability cannot be obtained in the conventional system and proposes a new selection method of flux reference to obtain maximum torque capability over the field weakening region by considering voltage, torque, and current limits.

  • PDF

Properties of Electrical Performance on Stator Coil of Traction Motor by Accelerated Test (견인전동기 고정자 코일의 전기적 열화특성)

  • Park Hyun-June;Jang Dong-Uk;Kim Gil-Dong
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.623-627
    • /
    • 2003
  • Aging and failure of motor insulation depend on the stresses imposed on it. The insulation life time depends on the severity of the stresses. The electrical aging by transient surge is very important to traction motor in EMU(electric multiple unit). This paper presents the insulation characteristics of stator coil by transient surge from inverter. There are several nondestructive tests available for checking the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of leakage current, dielectric loss($tan{\delta}$), capacitance, polarization index(PI) and partial discharge. The method of diagnosis is able to analyze the aging condition and predict the life of the traction motor in EMU.

  • PDF

Assessment of Insulation Condition between Diagnosis and Impregnation for Hydro-Generator (수력발전기의 절연보강 전${\cdot}$후 절연상태 비교평가)

  • Byun il-hwan;Lee Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1124-1126
    • /
    • 2004
  • The measurements were performed to assess the insulation deterioration condition of the stator winding of Dae-Cheong hydro-generator ${\sharp}2$ which had been in service after being constructed 1980. After repair of the stator winding insulation. we conducted insulation diagnostic tests which include resistance, polarization index(P. I). AC current, dissipation factor($Tan{\delta}$) and partial discharges ($Q_{max}$). The results of diagnostic tests were compared to the previous records. On the basis of these test results. this paper tried to present the importance of insulation repair for the generator stator winding.

  • PDF

A Rotor Speed Estimation of Induction Motors Using Sliding Mode Cascade Observer (슬라이딩 모드 축차 관측기를 이용한 유도 전동기 속도추정)

  • 김응석
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.53 no.3
    • /
    • pp.145-153
    • /
    • 2004
  • A nonlinear adaptive speed observer is designed for the sensorless control of induction motors. In order to design the speed observer, the measurements of the stator currents and the estimates of the rotor fluxes are used. The sliding mode cascade observer is designed to estimate the time derivatives of the stator currents. The open-loop observer is designed to estimate the rotor fluxes and its time derivatives using the stator current derivatives. The adaptive observer is also designed to estimate the rotor resistance. Sequentially, the rotor speed is calculated using these estimated values. It is shown that the estimation errors of the corresponding states and the parameters converge to the specified residual set. It is also shown that the speed controller using these estimates is performed well. The simulation examples are represented to investigate the validity of the proposed observers for the sensorless control of induction motors.