• Title/Summary/Keyword: stator current

Search Result 684, Processing Time 0.027 seconds

Study on the Post-Assembly Magnetization Method of Permanent Magnet Motor (영구자석형 전동기의 조립 후 착자 방법에 대한 연구)

  • Lee, C.K.;Kwon, B.I.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.104-106
    • /
    • 2003
  • In this paper, we study about the stator winding magnetization method and the magnetizing fixture magnetization method in post-assembly magnetization. Most of small electrical machine use the stator winding magnetization method but it is impossible to magnetize the permanent magnet by the stator winding magnetization method when the capacity of machine increases and the coercive force of magnet increases. And the eddy current disturbs the magnetization seriously in case of LSPM(Line Start Permanent magnet Motor) that have conductor bar in rotor. Hence, the magnetization fixture is required. So, in this paper we study about the post-assembly magnetization method that can use the stator winding magnetization method or must use the magnetization fixture magnetization method.

  • PDF

Maximum Torque Operating Strategy based on Stator Flux Analysis for Direct Torque and Flux Control of a SPMSM (고정자 자속의 해석을 통한 직접 토크 제어 SPMSM의 최대 토크 운전)

  • Kim, Sang-Hoon
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.463-469
    • /
    • 2014
  • This paper proposes a maximum torque operation strategy for the direct torque control of a surface-mounted permanent-magnet synchronous motor (SPMSM). The proposed method analyzes the available operation region of the stator flux of the SPMSM under voltage and current constraints. Based on this analysis, the optimal stator flux trajectory that yields the maximum torque is obtained across the entire operation region, including constant torque and constant power regions. The proposed strategy is also applicable in the flux-weakening region II operation of the SPMSM, which has no speed limit. The validity of the proposed method is verified through experiments conducted on an 800 W SPMSM drive system.

Detection of Stator Winding Inter-Turn Short Circuit Faults in Permanent Magnet Synchronous Motors and Automatic Classification of Fault Severity via a Pattern Recognition System

  • CIRA, Ferhat;ARKAN, Muslum;GUMUS, Bilal
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.416-424
    • /
    • 2016
  • In this study, automatic detection of stator winding inter-turn short circuit fault (SWISCFs) in surface-mounted permanent magnet synchronous motors (SPMSMs) and automatic classification of fault severity via a pattern recognition system (PRS) are presented. In the case of a stator short circuit fault, performance losses become an important issue for SPMSMs. To detect stator winding short circuit faults automatically and to estimate the severity of the fault, an artificial neural network (ANN)-based PRS was used. It was found that the amplitude of the third harmonic of the current was the most distinctive characteristic for detecting the short circuit fault ratio of the SPMSM. To validate the proposed method, both simulation results and experimental results are presented.

The Design of a patch Sensor for Partial Discharge diagnosis in Rotating Machine Stator Windings (회전기 고정자 권선의 부분방전 진단을 위한 평면 Patch Sensor 설계)

  • Yang, Sang-Hyun;Lim, Kwang-Jin;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2008.10a
    • /
    • pp.97-98
    • /
    • 2008
  • In 6.6kV Rotary Machine Stator Windings, Corona Discharge, Discharge at Conductor Surface, Slot Discharge and Endwinding Discharge is happended by electronic degradation. Also, if Partial Discharge cause in inner-part of Rotary Machine Stator Windings, it will be happended voltage and current pulse. In case of discharge spark, RF electromagnetic wave, which transmits at discharge position, can happen. To detect this kind of RF electromagnetic wave efficiently, we have designed Planar Antenna Sensor with the CST MWS simulation program. Also we have confined the application possibility, which can analyzes the partial discharge in Rotary Machine Stator Windings. In the Future, sample of planar antenna sensor will be able to compare with the data of simulation by CST MWS program.

  • PDF

Measurement and Comparison of Iron Loss in Bonded- and Embossed-Type Segmented Stator Cores for IPMSM

  • Jeong, Kwangyoung;Zhang, Dianhai;Kwon, Jaehoon;Ren, Ziyan;Koh, Chang-Seop
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2013-2018
    • /
    • 2014
  • According to the manufacturing process of the laminated stator core for an inserted permanent magnet synchronous motor (IPMSM), the iron loss may be different. It is because the mechanical stress imposed to electrical steel sheet is strongly dependent on the manufacturing process. This paper proposes a new iron loss measurement algorithm which utilizes the induced voltage of a search coil and exciting current. The method is effective even when the distribution of magnetic flux density is not uniform along the magnetic flux path as well as uniform. The developed iron loss measurement system is applied to bonded- and embossed-type segmented stator cores of an IPMSM, and the iron losses are quantitatively compared.

Characteristics of Insulation Failure in High Voltage Motor Stator Windings (고압전동기 고정자 권선의 절연파괴 특성)

  • Kim, Hee-Dong;Kim, Kyeong-Yeol;Park, Deok-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.124-124
    • /
    • 2010
  • Diagnostic tests were performed on six high voltage motors. These tests included ac current, dissipation factor(tan6) and partial discharge(PD) magnitude. The rewind of motor stator insulation at rated voltage is assessed by the results of these tests. After completing the diagnostic tests, the stator windings of motors were subjected to gradually increasing ac voltage, until the insulation punctured. No. 1 and No.2 motors(4.16 kV) failed near rated voltage of 12.3 kV and 14.2 kV, respectively. The breakdown voltage of No.3 and No.4 motors(6.6 kV) was 17.6 kV and 17.8 kV, respectively. These motors are higher that expected for good quality coils in 6.6 kV class motors.

  • PDF

A Study on Saturation Modeling of Synchronous Generator using Operating Data (운용 데이타를 이용한 동기발전기 포화 모델링에 관한 연구)

  • Kim, Kyung-Yul;Yoo, Ill-Do;Seo, Jang-Cheol;Moon, Seung-Ill
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.106-109
    • /
    • 1995
  • This paper presents a new saturation modeling technique of synchronous generators using the operating data. With the stator voltages, currents and the field current directly measured on the field winding at different steady state operating conditions, it can estimate tile saturated stator mutual inductances, stator resistance and the field-stator equivalent turns ratio. Effects of the measurement noises on tile estimated parameters are also investigated.

  • PDF

Grid Connection Algorithm for Doubly-Fed Induction Generator Using Rotor Side PWM Inverter-Converter (회전자측 PWM 인버터-컨버터를 사용한 이중여자 유도형 풍력 발전기의 계통 투입 알고리즘)

  • 정병창;권태화;송승호;김일환
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.10
    • /
    • pp.528-534
    • /
    • 2003
  • A grid connection algorithm is proposed for the doubly-fed induction generator (DFIG) which is widely adopted in high power variable speed wind turbine. Before the stator of DFIG is connected to grid, rotor-side converter is used to control the induced stator voltage. As a result, the stator transient current is limited below the rate value during the connection by the proposed synchronization of the stator voltage to the grid voltage. A wind power generation simulator using DC motor and wound-rotor induction generator is built and the dynamic characteristics of proposed algorithm is verified experimentally.

Speed Sensorless Vector Control for High Performance of Induction Motor (유도전동기의 고성능제어를 위한 속도센서리스 벡터제어)

  • Dong Hwa Chung
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.11
    • /
    • pp.37-46
    • /
    • 1993
  • Recently, the elimination of speed sensors has been one of the important requirement in vector control systems, because the speed sensor spoil the ruggedness and simplicity of induction motor. This paper proposes sensorless vector control for high performance of induction motor. The proposed vector control scheme is based on a rotor flux and speed which are calculated from the stator voltage and currents with improved flux estimator. The characteristics of vector control employing stator voltage and current generally deteriorate as the speed gets lower acause the calculated rotor flux depends on the stator resistance and it is difficult to calculate rotor flux at low speed of standstill. This new control system is robust with respect to variations of the stator resistance and it makes possible to calculated rotor flux at low speed of standstill. These feature are verified by the simulation results.

  • PDF

Induction Motor Parameter Identification using Step Response (계단 응답을 이용환 유도 전동기 파라미터 식별)

  • Jeon, Bum-Ho;Roh, Chi-Won;Ryu, Joon-Hyung;Lee, Kwang-Won
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.723-725
    • /
    • 2000
  • This paper presents a parameter identification method to estimate the stator resistance. stator inductance, rotor resistance and rotor inductance of the induction motor. A step voltage is applied across the stator terminals while the machine is in the standstill condition, and the resulting stator voltage and current response are measured. Observer/Kalman Filter Identification(OKID) algorithm is used to estimate induction motor parameters. Simulation results are presented to verify the identified model.

  • PDF