• Title/Summary/Keyword: statistical reconstruction

Search Result 207, Processing Time 0.022 seconds

Statistical Analysis of 3D Volume of Red Blood Cells with Different Shapes via Digital Holographic Microscopy

  • Yi, Faliu;Lee, Chung-Ghiu;Moon, In-Kyu
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.2
    • /
    • pp.115-120
    • /
    • 2012
  • In this paper, we present a method to automatically quantify the three-dimensional (3D) volume of red blood cells (RBCs) using off-axis digital holographic microscopy. The RBCs digital holograms are recorded via a CCD camera using an off-axis interferometry setup. The RBCs' phase image is reconstructed from the recorded off-axis digital hologram by a computational reconstruction algorithm. The watershed segmentation algorithm is applied to the reconstructed phase image to remove background parts and obtain clear targets in the phase image with many single RBCs. After segmenting the reconstructed RBCs' phase image, all single RBCs are extracted, and the 3D volume of each single RBC is then measured with the surface area and the phase values of the corresponding RBC. In order to demonstrate the feasibility of the proposed method to automatically calculate the 3D volume of RBC, two typical shapes of RBCs, i.e., stomatocyte/discocyte, are tested via experiments. Statistical distributions of 3D volume for each class of RBC are generated by using our algorithm. Statistical hypothesis testing is conducted to investigate the difference between the statistical distributions for the two typical shapes of RBCs. Our experimental results illustrate that our study opens the possibility of automated quantitative analysis of 3D volume in various types of RBCs.

A study of image evaluation and exposure dose with the application of Tube Voltage and ASIR of Low dose CT Using Chest Phantom (흉부 Phantom을 이용한 Low Dose CT의 관전압과 ASIR(Adaptive Statistical Iterative Reconstruction)적용에 따른 영상평가 및 피폭선량에 관한 연구)

  • Hwang, Hyeseong;Kim, Nuri;Jeong, Yoonji;Goo, Eunhoe;Kim, Kijeong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.9-14
    • /
    • 2014
  • Purpose: The purpose of this study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying Filtered Back Projection(FBP), the existing test method, and Adaptive Statistical Iterative Reconstruction(ASIR) with different values of tube voltage during the Low Dose Computed Tomography(LDCT). Materials and Methods: With the image reconstruction method as basis, Chest Phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of Tube Voltage (100kVp, 120kVp). For image evaluation, Back ground noise, Signal to Noise ratio(SNR) and Contrast to Noise ratio(CNR) were measured, and, for dose evaluation, CTDIvol and DLP were measured respectively. The statistical analysis was tested with SPSS(ver. 22.0), followed by ANOVA Test conducted after normality test and homogeneity test. (p<0.05). Results: In terms of image evaluation, there was no outstanding difference in Ascending Aorta(AA) SNR and Infraspinatus Muscle(IM) SNR with the different values of ASIR application(p<0.05), but a significant difference with the different amount of tube voltage(p>0.05). Also, there wasn't noticeable change in CNR with ASIR and different amount of Tube Voltage (p<0.05). However, in terms of dose evaluation, CTDIvol and DLP showed contrasting results(p<0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120kVp were 2.6mGy with No-ASIR and 2.17mGy with 20%-ASIR respectively, decreased by 0.43mGy, and the values with 100kVp were 1.61mGy with No-ASIR and 1.34mGy with 20%-ASIR, decreased by 0.27mGy. In terms of DLP, the measured values with 120kVp were $103.21mGy{\cdot}cm$ with No-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$(about 16.7%), and the values with 100kVp were $63.84mGy{\cdot}cm$ with No-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$(about 16.7%). Conclusion: At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise. For the future, through the result of the experiment, it is considered that the method above would be recommended for follow-up patients or those who get health checkup as long as there is no interference on the process of diagnosis due to the characteristics of Low Dose examination.

  • PDF

Usefulness of Muscle Plication and Synthetic Mesh in Breast Reconstruction Using TRAM Pedicled Flap (배곧은근피판을 이용한 유방재건 시 복벽의 주름형성과 합성그물을 이용한 복부성형술의 유용성)

  • Park, Jung Min;Park, Su Seong;Lee, Keun Cheol;Kim, Seok Kwun;Cho, Se Hyun
    • Archives of Plastic Surgery
    • /
    • v.33 no.5
    • /
    • pp.643-647
    • /
    • 2006
  • Purpose: The transverse rectus abdominis myocutaneous(TRAM) flap has become a mainstay of breast reconstruction. The chief disadvantage of the TRAM flap is its potential to create a weakness in the abdominal wall. Nowadays true hernia is less frequent, but bulging that appears at the muscle donor site, or at the contralateral side, or at the epigastric area is still remained as a problem. To prevent this complications, we have used synthetic mesh as well as abdominal muscle plication. Now we report the result of our methods. Methods: We started to use synthetic mesh and muscle plication as supplementary reinforcement for entire abdominal wall, after TRAM flap harvesting, in an attempt to stabilize it and achieve a superior aesthetic result since 2002. We observed complications of TRAM flap donor site, and compared our results (from January, 2002 to January, 2006) with other operator's result (before 2001) at the same hospital in aspect of incidence of abdominal complications. Results: 42 consecutive patients have been performed routine reinforcement with the extended mesh technique and muscle plication from January, 2002 to January, 2006. Mean patient follow up was 25.2 months. No hernia or mesh related infection were encountered and only one patient had a mild abdominal bulging. Nevertheless the our good results, there were no significant statistical differences were observed between two groups. Conclusion: We recommend the using of synthetic mesh and muscle plication for donor site reconstruction after TRAM flap breast reconstruction to improve strength as well as aesthetic quality of the abdominal wall.

Anterior inferior reconstruction plate on acute midshaft clavicle fvacture (쇄골 간부골절의 전하방 부착 재구성 금속판을 이용한 치료)

  • Kang, Jae-Do;Kim, Kwang-Ryul;Kim, Hyung-Chun;Lim, Moon-Sup;Kim, Seong-Hoon;Kweon, Jun-Hyung
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.1
    • /
    • pp.44-49
    • /
    • 2003
  • Purpose: Many different operative technique of mid-shaft clavicle fracture have been reported. The aim of this prospective study was to compare the results of anterior or anterior-inferior plating with superior plating on the acute mid-shaft fracture of clavicle Materials and Methods: From February1997 to February 2002, thirty-eight consecutive open reduction and internal fixation with reconstruction plates were performed in thirty-eight patients. from August 1999, anterior or anterior-inferior plating was mainly used, prospectively. The duration of follow-up averaged 17 months (range,23 to 43 months). The mean age was 38 years old (range,21 to 57 years old) on anterior or anterior-inferior plating group and 35 years old (range,24 to 55 years old) on superior plating group. The physician progress note, VAS patient complement score, Roentgenogram and ASES score was evaluated. Results: Four patients were lost to follow-up. There was no statistical difference on mean radiological bone union time (8.7 weeks vs. 8.6 weeks) and ASES score (92 vs 94) at inferior and superior plating groups (P > 0.05). VAS patient complement score was very good or excellent on anterior or anterior-inferior group, average score was 1.1 (ranger,0 to 2) compare with superior plating group (P < 0.05). There were two cases of infection, 1 case of failed fixation on superior plating group and 1 case of delayed union on anterior inferior plating group. Conclusion: Anterior inferior plating on acute clavicle midshaft fracture results in excellent patient complement score compare with conventional superior reconstruction plate.

Incidence and Risk Factors of Pulmonary Thromboembolism in Pedicled TRAM Breast Reconstruction (유경횡복직근피판을 이용한 유방복원술시 폐색전증의 발병률과 위험인자)

  • Lee, Sang Hyuk;Lee, Taik Jong;Eom, Jin Sup;Son, Byung Ho;Ahn, Sei Hyun;Lee, Sang Do
    • Archives of Plastic Surgery
    • /
    • v.33 no.2
    • /
    • pp.193-197
    • /
    • 2006
  • Pulmonary thromboembolism is often clinically silent and difficult to diagnose, and can be fatal to patients with belated treatment. This complication is seen in patients who underwent TRAM breast reconstruction. Multiple factors are involved in this disease such as the presence of malignancy itself, major surgery and therapy-related interventions. TRAM surgery is a lengthy procedure involving mastectomy, flap surgery and abdominoplasty. The purpose of this study is to evaluate the incidence and the correlation between presurgical risk factors(BMI and age) of symptomatic pulmonary thromboembolism after TRAM surgery and the incidence. From July 2001 to March 2005 a total of 384 pedicled TRAM reconstruction of breast was performed in 382 patients at Asan Medical Center. The average of Body mass index was $21.9kg/m^2$ and mean age of the patients was 37.9 years old. We diagnosed symptomatic pulmonary thromboembolism using ventilation/perfusion lung scan and pulmonary embolism computed tomography. Incidence of in-hospital symptomatic pulmonary thromboembolism was 1.3%. BMI and age showed no significant statistical relationship to pulmonary thromboembolism. But the incidence of symptomatic pulmonary thromboembolism in obese patients (BMI > 25) was 3.75%. According to the guideline of the 7th American College of Chest Physicians Consensus Conference on Antithrombotic and Thrombolytic Therapy, the incidence of 3.75% was classified as high risk group. The prevention of pulmonary thromboembolism should be considered in cases of obese patients with low molecular weight heparin(BMI > 25).

Evaluation of Abdominal Wall Function after TRAM Breast Reconstruction: A Prospective Study in 375 Consecutive Cases (횡복직근피판술을 이용한 유방재건 후 복벽의 운동능력에 관한 전향적 연구)

  • Kang, Byeong Su;Eom, Jin Sub;Lee, Taik Jong
    • Archives of Plastic Surgery
    • /
    • v.34 no.4
    • /
    • pp.436-440
    • /
    • 2007
  • Purpose: TRAM flap surgery has settled down as a common method for breast reconstruction after mastectomy. We investigated how TRAM flap surgery influences on the patients' physical movement capability by observing their capability of sit-ups as well as exercises they usually enjoy. Methods: A total of consecutive 375 patients were investigated who had breast reconstruction with unilateral pedicled TRAM flap surgery at Asan Medical Center from July 2001 to August 2005. The patients were asked to sit up right before the surgery and do it again 6 months later and 1 year later. 221 patients were followed up 6 month after the surgery. And 132 patients were followed up 1 year after the surgery. In addition, 155 patients who used to exercise before the surgery were also asked to show us the change in their physical movement capability one year after their surgery. Results: 139 patients showed decrease in the counted number of sit-ups, 48 increase, and 34 showed no change between 6 months in the first group of 221 patients. Among the second group of 132 patients, 64 showed decrease, 39 increase, and 29 no change a year later. There was a statistical significant decrease in the number of sit-ups between pre-operation and six months later and between pre-operation and one year later. According to the research on the exercise that 155 patients participated, 3 of them showed improvement in athletic ability, 7 showed decrease, while the rest, 145 patients, showed no change at all. Conclusion: Considering no difference in usual exercise ability, some patients' increase in the number of sit-ups and the effect of anticancer treatment, we found that the loss of abdominal wall function on this research is not too serious to exclude TRAM flap surgery in the field of breast reconstruction

Camber Reconstruction for a Prefab PSC Girder Using Collocated Strain Measurements (병치된 변형률 계측치를 이용한 프리팹 PSC 거더 캠버 재구성)

  • Kim, Hyun Young;Ko, Do Hyeon;Park, Hyun Woo
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.42 no.2
    • /
    • pp.151-162
    • /
    • 2022
  • Prefab members have attracted attention because they can be mass-produced in factories through smart construction technology. For prefab prestressed concrete girders, it is important to manage the shapes of the girders properly from production to the pre-installation stage for consistency with the prefab floor plate during the erection process. This paper presents a camber reconstruction method using collocated strain measurements from the top and bottom of the prefab girder. In particular, the camber reconstruction method is applied to measured strain data in which the time-dependent behavior of concrete is considered after the introduction of prestress. Through Monte Carlo numerical simulations, the statistical accuracy of the reconstructed camber for a limited number of sensors, measurement errors, and nonlinear time-dependent behaviors are analyzed and validated.

A Retrospective Study of Ear Reconstruction of Microtia (소이증 환자의 이개재건에 관한 후향적 연구)

  • Kim, Seok-Kwun;Moon, In-Sun;Kwon, Yong-Seok;Lee, Keun-Cheol
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.2
    • /
    • pp.109-113
    • /
    • 2009
  • Purpose: Materials for ear reconstruction are autogeneous cartilage and artificial implants. Despite their potential for donor site complications, autogeneous cartilage frameworks remain the accepted standard for external ear reconstruction. The purposes of this study were to investigate our ear reconstruction cases for 12 years. Methods: During twelve years from January 1996 to December 2008, 70 patients visited our hospital for ear reconstruction of microtia. Among them, 65 cases used autogenous cartilage frameworks, 3 cases used tissue expander and 2 cases used artificial implants. We investigated sex & age, common site, combined malformation, operation methods & their complications, donor site & their complications, anterior chest wall deformity and aesthetic evaluation. Results: Males were affected more often than females. Male to female ratio was 1.8 : 1. The common site of microtia was right ear (72%). And hemifacial microsomia was the most common associated congenital malformation. Surgical techniques included Tanzer-Ruecker method, Tissue-expander and Artificial framework ($Medpore^{(R)}$). Incidence of complication was higher with Tissue-expander & artificial framework than with Tanzer-Ruecker method. But There are few reports of using Tissue-expander & artificial framework and there was no acceptable statistical difference. And costal cartilage was harvested in ipsilateral side and anterior chest wall deformity reported only 2 cases under 10 year-old patients. Other minor complications reported such as, wound disruption and chest wall scar, but without any serious complications. Aesthetic result was evaluated by surgeons and patients for postoperative satisfaction and clinical evaluation. Conclusion: In ear reconstruction of microtia patient, delicate surgical strategy is important for natural shape and maintenance of postoperative contour. However, many methods were introduced for reconstrucion of microtia, the authors reconstructed an auricle in Tanzer-Ruecker method, Tissue-expander and Artificial famework ($Medpore^{(R)}$) for 70 patients. In our study, we generally chose Tanzer-Ruecker method and this treatment modality was satisfactory for patients and the postoperative result was acceptable for surgeons.

GCA Reconstruction Algorithm within the EM model for Transmission Computed Tomography (투과형 CT를 위한 EM 모형하에서 GCA 재구성 알고리즘)

  • 김승구
    • The Korean Journal of Applied Statistics
    • /
    • v.12 no.2
    • /
    • pp.537-551
    • /
    • 1999
  • 방출형 토모그래피와는 다르게, 토과형 토모그래피를 위한 통계적 알고리즘들은 매우 늦은 수렴속도와 엄청난 계산시간을 감수해야 했다. 그 주된 이유는 Lange-Carson 모형에 기초한 EM 알고리즘을 사용하고 있기 때문인데, 최근 GCA 기법의 등장으로 계산 시간을 현저히 단축할 수 있는 가능성이 제공되었다. 그러나 GCA 알고리즘은 우도의 단조중가성을 만족시키기 위해 부가적인 계산시간을 희생해야만 한다. 이에 본 연구에서는 프로그래밍이 간편하며, 처리시간이 짧고, 자체로 우도의 단조증가성을 만족하는 투과형 토모그래피를 위한 재구성 알고리즘을 제안한다.

  • PDF

3D Inspection of Printed Circuit Boards (PCB의 3차원 검사)

  • 조홍주;박현우;이준재
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2375-2378
    • /
    • 2003
  • In manufacture of printed circuit boards, one important issue is precisely to measure the three-dimensional shape of the solder paste silk-screened prior to direct surface mounting of chips. This paper presents the 3D shape reconstruction of solder paste using the optical triangulation method based on structured light or slit beam and the measurement algorithm for height, volume. area, and coplanarity on component pads from the 3D range image. Futhermore, statistical process control function is incorporated for process capability analysis.

  • PDF