• Title/Summary/Keyword: statistical reconstruction

Search Result 208, Processing Time 0.031 seconds

Evaluation of the Effect of the Arrhythmia Correction for the Image Quality in the Multidetector-Row Computed Tomography (MDCT) Coronary Angiography (Multidetector-Row Computed Tomography (MDCT) Coronary Agniography에서 Arrhythmia Correction이 영상의 질에 미치는 영향에 관한 연구)

  • Kim, Hyun-Soo;Kim, Keung-Sik;Kim, Tae-Hoon;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.27 no.2
    • /
    • pp.7-12
    • /
    • 2004
  • MDCT is a useful, non-invasive, diagnostic tool in the evaluation of coronary artery disease. However, the image quality is affected by an irregular heart rhythm of the patients. Especially, premature ventricular contraction induced stair-step artifacts in the reconstruction of 2-D or 3-D images of the heart including coronary arteries. In recent, we experienced some improving of the image quality after correcting the PVC. Accordingly, the purpose of our study was to evaluate the effectiveness of the arrhythmia correction method, which was commercially available software, in improving the quality of the reconstruction images of the heart. Image analysis was performed, in consensus, by two radiologists. The scores for image quality were ranked as follows; excellent is 4 (image quality is markedly improved and is helpful in the image evaluation), good is 3 (image quality is mildly improved, but is somewhat helpful in the image evaluation), fair is 2 (image quality is improved and is not helpful in the image evaluation), and poor is 1 (image quality is not improved). We used ANOVA method to evaluate the statistical significant differences in the image qualities among the correction methods of the arrhythmia with below 0.05 of p-value. The method of moving the R-R interval showed statistically significant differences in improving of the image quality in patients with arrhythmia. We concluded that the regulation of R-R interval in patients with arrhythmia was an effective method to improve the image quality in the reconstructions of the MDCT coronary angiograms.

  • PDF

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF

The Relationship between the Size and the Invasion Depth of Tumors in Head and Neck Cutaneous Squamous Cell Carcinoma

  • Lee, Sam Yong;Hwang, Won Joo;Kim, Kyung Pil;Kim, Hong Min;Hwang, Jae Ha;Kim, Kwang Seog
    • Archives of Plastic Surgery
    • /
    • v.43 no.6
    • /
    • pp.538-543
    • /
    • 2016
  • Background Cutaneous squamous cell carcinoma (SCC), which occurs in keratinocytes of the epidermis and is the second most common skin cancer, has a more invasive growth pattern and higher potential to metastasize than basal cell carcinoma. Total excision of the primary tumor is the treatment of choice. For clear excision of the tumor, invasion depth is one of the most important factors. This study was conducted to clarify the relationship between the size and the invasion depth of cutaneous SCC. Methods Twenty-six cases were collected for this prospective study. Frozen biopsies were examined after complete resection of the tumor, followed by histological confirmation by pathological examination. The major and minor axis lengths of the tumor, the invasion depth, and the level of invasion were measured. Recurrence or metastasis was recorded through regular follow-up. Results The Pearson correlation coefficient was used for statistical analysis. Significant results were observed for the relationship between the major and minor axis lengths and the invasion depth of the tumor (0.747, 0.773). No cases of recurrence or metastasis were observed. Conclusions In head and neck cutaneous SCC, the invasion depth of the tumor is closely related to the major and minor axis lengths of the tumor. Therefore, the invasion depth of the tumor can be estimated by measuring the size of the tumor, and a standard vertical safety margin for head and neck cutaneous SCC can be established, which could be helpful in the development of a preoperative reconstruction plan.

Follow-up Comparison of Two Different Types of Anterior Thoracolumbar Instrumentations in Trauma Cases : Z-plate vs. Kaneda Device

  • Park, Jung-Keun;Kim, Keun-Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.2
    • /
    • pp.77-81
    • /
    • 2007
  • Objective : In a variety of thoracolumbar diseases, corpectomy followed by interbody bone graft and anterior instrumentation has allowed direct neural decompression and reconstruction of the weight-bearing column by short segments fusion. In this study, we compared spinal stability of the two different anterior thoracolumbar instruments : Z-plate and Kaneda device representing plate and two-rods type, respectively. Methods : A retrospective review was performed for all the patients with thoracolumbar diseases or traumas treated with anterior corpectomy, autologous iliac bone graft, and fixation with instruments from 1996 to 2000. For the anterior instrumentation, Z-plate or Kaneda device was used for 24 [M:F=5:9, average age=37] and 12 [M:F=9:3, average age=41] patients, respectively. The plain AP and lateral flexion-extension films were taken immediately after surgery and at each follow-up. The sagittal and coronal Cobb's angles at the operation segments were used to observe the change of initial fixation status. The surgical time length and bleeding amount of the two groups were compared. Intra-operative and post-operative instrument associated complications were evaluated. Student t-test was used for statistical analysis and p-value less than 0.05 was considered to be significant. Results : Mean follow-up durations for Z-plate and Kaneda device were 24 and 21 months, respectively. The fusion rate was 91% for Z-plate and 100% for Kaneda device. Two cases of Z-plate group showed instrumentation failure during the follow up period, in which additional surgery was necessary. The mean differences of sagittal Cobb's angles among the AP images immediate after surgery and at follow-up were 7 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. The mean differences of coronal Cobb's angles were 5 and 2 degrees for Z-plate and Kaneda device, respectively [p<0.05]. No Intra-operative complication has occurred in both groups. There was no difference in surgery time and bleeding amount between two groups. Conclusion : We think that Kaneda device [rod type] is stronger than Z-plate [plate type] to keep the spinal stability after anterior thoracolumbar surgery.

Spontaneous bone regeneration after enucleation of jaw cysts: a comparative study of panoramic radiography and computed tomography (악골 낭종의 적출술 후 골재생에 대한 파노라마 촬영과 컴퓨터 단층촬영의 비교 분석)

  • Kim, Taek-Sung;Lee, Jae-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.2
    • /
    • pp.100-107
    • /
    • 2010
  • Introduction: A cyst is a closed pathologic sac containing fluid or semi-solid material in central region. The most common conventional treatment for a cyst is enucleation. It was reported that spontaneous bone healing could be accomplished without bone grafting. We are trying to evaluate bone reconstruction ability by analyzing panorama radiograph and computed tomography (CT) scan with retrograde studying after cyst enucleation. In this way we are estimating critical size defect for spontaneous healing without bone graft. Materials and Methods: The study comprised of 45 patients who were diagnosed as cysts and implemented enucleation treatment without bone graft. After radiograph photo taking ante and post surgery for 6, 12, 18, 24 months, the healing surface and volumetric changes were calculated. Results: 1. Spontaneous bone healing was accomplished clinically satisfying 12 months later after surgery. But analyzing CT scan, defect volume changes indicate 79.24% which imply incomplete bone healing of defect area. 2. Comparing volume changes of defect area of CT scan, there are statistical significance between under $5,000mm^{3}$ and over $5,000mm^{3}$. The defect volume of $5,000mm^{3}$ shows $2.79{\times}1.91$cm in panoramic view. Conclusion: Bone defects, which are determined by a healed section using a panoramic view, compared to CT scans which do not show up. Also we can estimate the critical size of defects for complete healing.

Clinical analysis of Pediatric Blow out Fracture (소아 안와 골절의 임상 분석)

  • Pak, Chang Sik;Kim, Yong Kyu;Chung, Sung Mo
    • Archives of Plastic Surgery
    • /
    • v.35 no.5
    • /
    • pp.560-564
    • /
    • 2008
  • Purpose: Because of traffic accidents and many criminal violences, the incidence of facial trauma has been increasing not only in adults but also in children. We planed this study to introduce our experience about pediatric blow out fracture and provide more information. Methods: We made retrospective study in 76 children with blow out fracture from January 2001 to September 2005 by retrospective chart review including detailed preoperative and postoperative evaluations, age, sex, cause, symptom and sign, and their post-operative complications. Results: Among our patients, 69 were male and 7 were female. The ages ranged from 7 to 18 years, which shows the greatest incidence of blow out fracture. Physical violence(46%) was the most common cause in this group and was followed by vehicle accident(28%), and fall down accident(17%). Left side(64%) showed slightly more incidence than right side(36%), but there were no statistical importance. Ecchymosis(88%) was the most common symptom and followed by periorbital swelling(68%) and diplopia(30%). 30 patients was diagnosed with another facial bone fracture and nasal bone(51%) was the most common associated facial bone fracture. Fourty four Patients(60%) got an orbital wall reconstruction in 7 days after trauma. After the operation, only 3 patients(4%) suffered from diplopia postoperative 3 month, and resolved in 4 years. Conclusion: The incidence of blow out fracture in children has been increasing every year, and violence has become more important etiology of pediatric blow out fracture and public and private education institutions were the most common place that blow out fracture originated. Accurate diagnosis and careful treatment plans are important in pediatric blow out fracture.

Development of an ACL Anchor: Effects of the Design Parameters on the Performance of a New Anterior Cruciate Ligament Fixation Device

  • Kim, Jong-Dae;Oh, Chae-Youn;Kim, Cheol-Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.132-138
    • /
    • 2008
  • We investigated the biomechanical properties of a newly designed self-expansion type anterior cruciate ligament (ACL) anchor. The ACL anchor consists of the ring section giving the elastic force, the wedge for maintaining in contact with the femur tunnel wall and the link suspending hamstring graft or artificial ligament. The main design parameters that determine the performance of this device were the expansion angle (${\theta}$) and the thickness ($t_R$). The Ti6Al4V anchors were heated after inserting in a jig for 1 hour at $800^{\circ}C$ in a protective argon gas atmosphere and allowed to cool to room temperature in the furnace. In order to investigate the influence of the expansion angle and the thickness of the ring on the biomechanical properties of the anchor, the maximum pull-out load, stiffness and slippage of the ACL anchor were measured using the pull-out tester, and statistical analyses were also executed. The present results showed that the design parameters gave a significant effect on the performance of the self- expansion type of anchor. The pull-out load of the ACL anchors significantly increased as the thickness of the ring section was increased, having a similar trend for both expansion angles. The ACL anchor showed about 2.5 times higher values of the pull-out load than that of the minimum load (500N)required for the "accelerated rehabilitation". The optimum ${\theta}$ and $t_R$ values of this ACL anchor were suggested to have sufficient resistance against the pull-out force, high stiffness and relatively low slippage after ACL reconstruction.

The development of statistical methods for retrieving MODIS missing data: Mean bias, regressions analysis and local variation method (MODIS 손실 자료 복원을 위한 통계적 방법 개발: 평균 편차 방법, 회귀 분석 방법과 지역 변동 방법)

  • Kim, Min Wook;Yi, Jonghyuk;Park, Yeon Gu;Song, Junghyun
    • Journal of Satellite, Information and Communications
    • /
    • v.11 no.4
    • /
    • pp.94-101
    • /
    • 2016
  • Satellite data for remote sensing technology has limitations, especially with visible range sensor, cloud and/or other environmental factors cause missing data. In this study, using land surface temperature data from the MODerate resolution Imaging Spectro-radiometer(MODIS), we developed retrieving methods for satellite missing data and developed three methods; mean bias, regression analysis and local variation method. These methods used the previous day data as reference data. In order to validate these methods, we selected a specific measurement ratio using artificial missing data from 2014 to 2015. The local variation method showed low accuracy with root mean square error(RMSE) more than 2 K in some cases, and the regression analysis method showed reliable results in most cases with small RMSE values, 1.13 K, approximately. RMSE with the mean bias method was similar to RMSE with the regression analysis method, 1.32 K, approximately.

A Study for the Enhancement of Korean Married Womans's Quality of Life - Development of A Program and Effect Analysis - (한국 기혼여성의 일상적 삶의 질 향상에 관한 연구(III) -프로그램 개발 및 효과분석 -)

  • Kim, Jung-Ja;Sim, Hae-Sook;Kim, Kyong-Yeon;Kim, Seon-Hee;Chong, Young-Sook;Choi, Won-Chul;Choi, Soon;Moon, So-Jung
    • Journal of the Korean Home Economics Association
    • /
    • v.38 no.1
    • /
    • pp.99-122
    • /
    • 2000
  • The purpose of this study was to develop a program for the enhancement of Korean married women's quality of life(LQ) based on the results of the first year study(1996) and the second year research(1998). In order to construct a program, a psycological type test was conducted to 505 women and four preliminary programs were carried out focusing on self-esteem, understanding of one's own personality dynamics, efficient communication, positive emotion, social belongingness and expressions of feelings of unfinished business. For the final program, Jung's theory of psychological type(MBTI, Satir's family therapy approach and psychodrama were applied. An experimental and a control group were designed consisting 16 women for each group. The program was carried out for 6 weeks for the experimental group. The result of treatment were as follows: 1) There was a difference statistically in LQ related to family harmony, serif-achievement and improvement of relationship with in-laws. 2) There was a statistical change in psychological factors of expression of feelings, self-esttem, communication, and positive emotions. 3) The program participants self reports indicate that the program was effective for the reconstruction of family relationship, self-understanding, group coherence, and instigation of hope. The reports also shows that the program was effective for the perceptual changes in parent-child, wife-husband and siblings' relationships. In conclusion, the program developed for the enhancement of Korean married women's life quality(LQ) based on the Jung's psychological type theory, Satir's family therapy approach and psychodrama was erective for the improvement of LQ.

  • PDF

Experimental Analysis of Recent Works on the Overlap Phase of De Novo Sequence Assembly (De novo 시퀀스 어셈블리의 overlap 단계의 최근 연구 실험 분석)

  • Lim, Jihyuk;Kim, Sun;Park, Kunsoo
    • Journal of KIISE
    • /
    • v.45 no.3
    • /
    • pp.200-210
    • /
    • 2018
  • Given a set of DNA read sequences, de novo sequence assembly reconstructs a target sequence without a reference sequence. For reconstruction, the assembly needs the overlap phase, which computes all overlaps between every pair of reads. Since the overlap phase is the most time-consuming part of the whole assembly, the performance of the assembly depends on that of the overlap phase. There have been extensive studies on the overlap phase in various fields. Among them, three state-of-the-art results for the overlap phase are Readjoiner, SOF, and Lim-Park algorithm. Recently, a rapid development of sequencing technology has made it possible to produce a large read dataset at a low cost, and many platforms for generating a DNA read dataset have been developed. Since the platforms produce datasets with different statistical characteristics, a performance evaluation for the overlap phase should consider datasets with these characteristics. In this paper, we compare and analyze the performances of the three algorithms with various large datasets.