• Title/Summary/Keyword: statistical data analysis

Search Result 9,252, Processing Time 0.042 seconds

Effect of RGD peptide coating of implant titanium surface on human mesenchymal stem cell response (양극산화 티타늄 표면에 서로 다른 RGD 펩타이드 코팅 방법이 인간간엽줄기세포 반응에 미치는 영향)

  • Kim, Min-Su;Jeong, Chang-Mo;Jeon, Young-Chan;Ryu, Jae-Jun;Huh, Jung-Bo;Yun, Mi-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.245-253
    • /
    • 2011
  • Purpose: The aim of this in vitro study was to estimate surface characteristic after peptide coating and investigate biological response of human mesenchymal stem cell to anodized titanium discs coated with RGD peptide by physical adhesion and chemical fixation. Materials and methods: Fluorescence isothiocyanate (FITC) modified RGD-peptide was coated on the anodized titanium discs (diameter 12 mm, height 3 mm) using two methods. One was physical adhesion method and the other was chemical fixation method. Physical adhesion was performed by dip and dry procedure, chemical fixation was performed by covalent bond via silanization. In this study, human mesenchymal stem cell was used for experiments. The experiments consisted of surface characteristic evaluation after peptide coating, analysis about cell adhesion, proliferation, differentiation, and mineralization. Obtained data are statistically treated using Kruskal-Wallis test and Bonferroni test was performed as post hoc test (P=.05). Results: The evaluation of FE-SEM images revealed no diffenrence at micro-surfaces between each groups. Total coating dose was higher at physical adhesion experimental group than at chemical fixation experimental group. In cell adhesion and proliferation, RGD peptide coating did not show a statistical significance compared with control group (P>.05). In cell differentiation and mineralization, physical adhesion method displayed significantly increased levels compared with control group and chemical fixation method (P<.05). Conclusion: RGD peptide coating seems to enhance osseointegration by effects on the response of human mesenchymal stem cell. Especially physical adhesion method showed more effective than chemical fixation method on response of human mesenchymal stem cell.

Simulation of Drying Grain with Solar-Heated Air (태양에너지를 이용한 곡물건조시스템의 시뮬레이션에 관한 연구)

  • 금동혁;김용운
    • Journal of Biosystems Engineering
    • /
    • v.4 no.2
    • /
    • pp.65-83
    • /
    • 1979
  • Low-temperature drying systems have been extensively used for drying cereal grain such as shelled corn and wheat. Since the 1973 energy crisis, many researches have been conducted to apply solar energy as supplemental heat to natural air drying systems. However, little research on rough rice drying has been done in this area, especially very little in Korea. In designing a solar drying system, quality loss, airflow requirements, temperature rise of drying air, fan power and energy requirements should be throughly studied. The factors affecting solar drying systems are airflow rate, initial moisture content, the amount of heat added to drying air, fan operation method and the weather conditions. The major objectives of this study were to analyze the effects of the performance factors and determine design parameters such as airflow requirements, optimum bed depth, optimum temperature rise of drying air, fan operation method and collector size. Three hourly observations based on the 4-year weather data in Chuncheon area were used to simulate rough rice drying. The results can be summarized as follows: 1. The results of the statistical analysis indicated that the experimental and predicted values of the temperature rise of the air passing through the collector agreed well. 2. Equilibrium moisture content was affected a little by airflow rate, but affected mainly by the amount of heat added, to drying air. Equilibrium moisture content ranged from 12.2 to 13.2 percent wet basis for the continuous fan operation, from 10.4 to 11.7 percent wet basis for the intermittent fan operation respectively, in range of 1. 6 to 5. 9 degrees Centigrade average temperature rise of drying air. 3. Average moisture content when top layer was dried to 15 percent wet basis ranged from 13.1 to 13.9 percent wet basis for the continuous fan operation, from 11.9 to 13.4 percent wet basis for the intermittent fan operation respectively, in the range of 1.6 to 5.9 degrees Centigrade average temperature rise of drying air and 18 to 24 percent wet basis initial moisture content. The results indicated that grain was overdried with the intermittent fan operation in any range of temperature rise of drying air. Therefore, the continuous fan operation is usually more effective than the intermittent fan operation considering the overdrying. 4. For the continuous fan operation, the average temperature rise of drying air may be limited to 2.2 to 3. 3 degrees Centigrade considering safe storage moisture level of 13.5 to 14 perceut wet basis. 5. Required drying time decrease ranged from 40 to 50 percent each time the airflow rate was doubled and from 3.9 to 4.3 percent approximately for each one degrees Centigrade in average temperature rise of drying air regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on required drying time. 6. Required drying time increase ranged from 18 to 30 percent approximately for each 2 percent increase in initial moisture content regardless of the fan operation methods, in the range of 18 to 24 percent moisture. 7. The intermittent fan operation showed about 36 to 42 percent decrease in required drying time as compared with the continuous fan operation. 8. Drymatter loss decrease ranged from 34 to 46 percent each time the airflow rate was doubled and from 2 to 3 percent approximately for each one degrees Centigrade in average temperature rise of drying air, regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on drymatter loss. 9. Drymatter loss increase ranged from 50 to 78 percent approximately for each 2 percent increase in initial moisture content, in the range of 18 to 24 percent moisture. 10. The intermittent fan operation: showed about 40 to 50 percent increase in drymatter loss as compared with the continuous fan operation and the increasing rate was higher at high level of initial moisture and average temperature rise. 11. Year-to-year weather conditions had a little effect on required drying time and drymatter loss. 12. The equations for estimating time required to dry top layer to 16 and 1536 wet basis and drymatter loss were derived as functions of the performance factors. by the least square method. 13. Minimum airflow rates based on 0.5 percent drymatter loss were estimated. Minimum airflow rates for the intermittent fan operation were approximately 1.5 to 1.8 times as much as compared with the continuous fan operation, but a few differences among year-to-year. 14. Required fan horsepower and energy for the intermittent fan operation were 3. 7 and 1. 5 times respectively as much as compared with the continuous fan operation. 15. The continuous fan operation may be more effective than the intermittent fan operation considering overdrying, fan horsepower requirements, and energy use. 16. A method for estimating the required collection area of flat-plate solar collector using average temperature rise and airflow rate was presented.

  • PDF

Simulation of Drying Grain with Solar-Heated Air (태양에너지를 이용한 곡물건조시스템의 시뮬레이션에 관한 연구)

  • Keum, Dong-Hyuk
    • Journal of Biosystems Engineering
    • /
    • v.4 no.2
    • /
    • pp.64-64
    • /
    • 1979
  • Low-temperature drying systems have been extensively used for drying cereal grain such as shelled corn and wheat. Since the 1973 energy crisis, many researches have been conducted to apply solar energy as supplemental heat to natural air drying systems. However, little research on rough rice drying has been done in this area, especially very little in Korea. In designing a solar drying system, quality loss, airflow requirements, temperature rise of drying air, fan power and energy requirements should be throughly studied. The factors affecting solar drying systems are airflow rate, initial moisture content, the amount of heat added to drying air, fan operation method and the weather conditions. The major objectives of this study were to analyze the effects of the performance factors and determine design parameters such as airflow requirements, optimum bed depth, optimum temperature rise of drying air, fan operation method and collector size. Three hourly observations based on the 4-year weather data in Chuncheon area were used to simulate rough rice drying. The results can be summarized as follows: 1. The results of the statistical analysis indicated that the experimental and predicted values of the temperature rise of the air passing through the collector agreed well.2. Equilibrium moisture content was affected a little by airflow rate, but affected mainly by the amount of heat added, to drying air. Equilibrium moisture content ranged from 12.2 to 13.2 percent wet basis for the continuous fan operation, from 10.4 to 11.7 percent wet basis for the intermittent fan operation respectively, in range of 1. 6 to 5. 9 degrees Centigrade average temperature rise of drying air.3. Average moisture content when top layer was dried to 15 percent wet basis ranged from 13.1 to 13.9 percent wet basis for the continuous fan operation, from 11.9 to 13.4 percent wet basis for the intermittent fan operation respectively, in the range of 1.6 to 5.9 degrees Centigrade average temperature rise of drying air and 18 to 24 percent wet basis initial moisture content. The results indicated that grain was overdried with the intermittent fan operation in any range of temperature rise of drying air. Therefore, the continuous fan operation is usually more effective than the intermittent fan operation considering the overdrying.4. For the continuous fan operation, the average temperature rise of drying air may be limited to 2.2 to 3. 3 degrees Centigrade considering safe storage moisture level of 13.5 to 14 perceut wet basis.5. Required drying time decrease ranged from 40 to 50 percent each time the airflow rate was doubled and from 3.9 to 4.3 percent approximately for each one degrees Centigrade in average temperature rise of drying air regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on required drying time.6. Required drying time increase ranged from 18 to 30 percent approximately for each 2 percent increase in initial moisture content regardless of the fan operation methods, in the range of 18 to 24 percent moisture.7. The intermittent fan operation showed about 36 to 42 percent decrease in required drying time as compared with the continuous fan operation.8. Drymatter loss decrease ranged from 34 to 46 percent each time the airflow rate was doubled and from 2 to 3 percent approximately for each one degrees Centigrade in average temperature rise of drying air, regardless of the fan operation methods. Therefore, the average temperature rise of drying air had a little effect on drymatter loss. 9. Drymatter loss increase ranged from 50 to 78 percent approximately for each 2 percent increase in initial moisture content, in the range of 18 to 24 percent moisture. 10. The intermittent fan operation: showed about 40 to 50 percent increase in drymatter loss as compared with the continuous fan operation and the increasing rate was higher at high level of initial moisture and average temperature rise.11. Year-to-year weather conditions had a little effect on required drying time and drymatter loss.12. The equations for estimating time required to dry top layer to 16 and 1536 wet basis and drymatter loss were derived as functions of the performance factors. by the least square method.13. Minimum airflow rates based on 0.5 percent drymatter loss were estimated.Minimum airflow rates for the intermittent fan operation were approximately 1.5 to 1.8 times as much as compared with the continuous fan operation, but a few differences among year-to-year.14. Required fan horsepower and energy for the intermittent fan operation were3. 7 and 1. 5 times respectively as much as compared with the continuous fan operation.15. The continuous fan operation may be more effective than the intermittent fan operation considering overdrying, fan horsepower requirements, and energy use.16. A method for estimating the required collection area of flat-plate solar collector using average temperature rise and airflow rate was presented.

Development and Application of a Methodologyfor Climate Change Vulnerability Assessment-Sea Level Rise Impact ona Coastal City (기후변화 취약성 평가 방법론의 개발 및 적용 해수면 상승을 중심으로)

  • Yoo, Ga-Young;Park, Sung-Woo;Chung, Dong-Ki;Kang, Ho-Jeong;Hwang, Jin-Hwan
    • Journal of Environmental Policy
    • /
    • v.9 no.2
    • /
    • pp.185-205
    • /
    • 2010
  • Climate change vulnerability assessment based on local conditions is a prerequisite for establishment of climate change adaptation policies. While some studies have developed a methodology for vulnerability assessment at the national level using statistical data, few attempts, whether domestic or overseas, have been made to develop methods for local vulnerability assessments that are easily applicable to a single city. Accordingly, the objective of this study was to develop a conceptual framework for climate change vulnerability, and then develop a general methodology for assessment at the regional level applied to a single coastal city, Mokpo, in Jeolla province, Korea. We followed the conceptual framework of climate change vulnerability proposed by the IPCC (1996) which consists of "climate exposure," "systemic sensitivity," and "systemic adaptive capacity." "Climate exposure" was designated as sea level rises of 1, 2, 3, 4, and 5 meter(s), allowing for a simple scenario for sea level rises. Should more complex forecasts of sea level rises be required later, the methodology developed herein can be easily scaled and transferred to other projects. Mokpo was chosen as a seaside city on the southwest coast of Korea, where all cities have experienced rising sea levels. Mokpo has experienced the largest sea level increases of all, and is a region where abnormal high tide events have become a significant threat; especially subsequent to the construction of an estuary dam and breakwaters. Sensitivity to sea level rises was measured by the percentage of flooded area for each administrative region within Mokpo evaluated via simulations using GIS techniques. Population density, particularly that of senior citizens, was also factored in. Adaptive capacity was considered from both the "hardware" and "software" aspects. "Hardware" adaptive capacity was incorporated by considering the presence (or lack thereof) of breakwaters and seawalls, as well as their height. "Software" adaptive capacity was measured using a survey method. The survey questionnaire included economic status, awareness of climate change impact and adaptation, governance, and policy, and was distributed to 75 governmental officials working for Mokpo. Vulnerability to sea level rises was assessed by subtracting adaptive capacity from the sensitivity index. Application of the methodology to Mokpo indicated vulnerability was high for seven out of 20 administrative districts. The results of our methodology provides significant policy implications for the development of climate change adaptation policy as follows: 1) regions with high priority for climate change adaptation measures can be selected through a correlation diagram between vulnerabilities and records of previous flood damage, and 2) after review of existing short, mid, and long-term plans or projects in high priority areas, appropriate adaptation measures can be taken as per this study. Future studies should focus on expanding analysis of climate change exposure from sea level rises to other adverse climate related events, including heat waves, torrential rain, and drought etc.

  • PDF

Estimation of the Superelevation Safety Factor Considering Operating Speed at 3-Dimensional Alignment (입체선형의 주행속도를 고려한 편경사 안전율 산정에 관한 연구)

  • Park, Tae-Hoon;Kim, Joong-Hyo;Park, Je-Jin;Park, Ju-Won;Ha, Tae-Jun
    • Journal of Korean Society of Transportation
    • /
    • v.23 no.7 s.85
    • /
    • pp.159-163
    • /
    • 2005
  • The propriety between suppliers and demanders in geometric design is very important. Although the final purpose of constructing roads is to concern about the driver s comfort, unfortunately, it has not been considered so far. We've considered the regularity and quickness in considering driver's comfort but there should be considered the safety for the accident as well. If drivers are appeared to be more speeding than designer's intention, there will be needed some supplements to increase the safety rate for the roads. Even if both an upward and downward section are supposed to exist at the same time for solid geometry of the roads like this, it is true that the recent design for the 3-D solid geometry section has been done as flat 2-D and the minimum plane curve radius and the maximum cant have been decided just by calculating without considering operating speed between an upward and downward section at the same point. In this investigation, thus, I'd like to calculate the safety of the cant by considering the speed features of the solid geometry for the first lane of four lane rural roads. To begin with, we investigated the driving speed of the car, which is not been influenced by a preceding car to analyze the influence of the geometrical structure by using Nc-97. Secondly, we statistically analyzed the driving features of the solid geometry after comparing the 6 sections, that is, measuring the driving speed feature at 12 points and combining the influence of the vertical geometry and plane geometry to the driving speed of the plane curve which was researched before. Finally, we estimated the value of cant which considers the driving speed not by using it which has applied uniformly without considering it properly, though there were some differences between a designed speed and driving speed through the result of the basic statistical analysis but by introducing the new safety rate rule, a notion of ${\alpha}$. As a result of the research, we could see the driving features of the car and suggest the safety rate which considers these. For considering the maximum cant, if we apply the safety rate, the result of this experiment, which considers 3-D solid geometry, there'll be the improvement of the driver's safety for designing roads. In addition, after collecting and analyzing the data for the road sections which have various geometrical structures by expanding this experiment it is considered that there should be developed the models which considers 3-D solid geometry.

Development of Aceclofenac Soft Capsule (Clanza S Soft Capsule) (아세클로페낙 연질캡슐(클란자 에스 연질캡슐)의 개발)

  • Yong, Chul-Soon;Lee, Kyung-Hee;Choi, Jin-Suck;Park, Byung-Joo;Jung, Se-Hyun;Kim, Yong-Il;Park, Sang-Man;Bae, Myung-Soo;Kim, Gui-Ja;Gill, Young-Sig;Yu, Chang-Hun;Kang, Sung-Lyoung;Yoo, Bong-Kyu;Rhee, Jong-Dal;Choi, Han-Gon
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.1
    • /
    • pp.49-55
    • /
    • 2004
  • To develop a aceclofenac soft capsule, four preparations with various solubilizers were prepared and their dissolution test was carried out. Among four preparations tested, a preparation with ethanolamine was selected as a formula of aceclofenac soft capsule (Clanza $S^{TM}$), since it showed the fastεst dissolution rate. Bioequivalence of aceclofenac tablet, $Airtal^{TM}$ (Dae-Woong Pharmaceutical Co., Ltd.) and aceclofenac soft capsule, Clanza $S^{TM}$ (Korea United Pharmaceutical Co., Ltd.) was evaluated according to the guideline of KA Fourteen normal male volunteers (age 20 - 25 years old) were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After oral administration of one tablet or capsule containing 100 mg of aceclofenac, blood was taken at predetermined time intervals and the concentration of aceclofenac in plasma was determined with an HPLC method under UV detector The pharmacokinetic parameters ($C_{max}$ and $AUC_t$) were calculated and ANOVA was utilized for the statistical analysis of parameters using logarithmetically transformed $AUC_t$, $C_{max}$ and $T_{max}$. The results showed that the differences in $AUC_t$, $C_{max}$ and $T_{max}$ between Aral tablet and Clanza soft capsule were 2.89%, 0.18% and 43.0%, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log(0.8) to log(15) (e.g. log(0.81) -log(1.23) ad log(0.89) -log(1.4)) fo $AUC_t$ and $C_{max}$, respectively. Thus, the criteria of the KFDA guidelines for the equivalence was satisfied, indicating that Clanza $S^{TM}$ soft capsule is bioequivalent to$Airtal^{TM}$ tablet.

Bioequivalence of Burophil Capsule to Surfolase Capsule (Acebrophylline 100 mg) (설포라제 캡슐(아세브로필린 100 mg)에 대한 부로필 캡슐의 생물학적 동등성)

  • Cho, Hea-Young;Park, Eun-Ja;Kang, Hyun-Ah;Kim, Se-Mi;Park, Chan-Ho;Oh, In-Joon;Lim, Dong-Koo;Lee, Myung-Hee;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.3
    • /
    • pp.179-185
    • /
    • 2005
  • Acebrophylline is a compound produced by salifying ambroxol with theophylline-7 -acetic acid. After acebrophylline administration, the salt splits into these two components which feature a peculiar pharmacokinetic behavior, an adequate ambroxol and a low theophylline-7-acetic acid serum levels. The purpose of the present study was to evaluate the bioequivalence of two acebrophylline capsules, Surfolase (Hyundai Pharm. lnd. Co., Ltd.) and Burophil (Kuhnil Pharm. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of ambroxol from the two acebrophylline formulations in vitro was tested using KP VIII Apparatus II method with various dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty eight healthy male subjects, $23.25{\pm}1.43$ years in age and $64.82{\pm}6.77$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After two capsules containing 100 mg as acebrophylline were orally administered, blood was taken at predetermined time intervals and the concentrations of ambroxol in serum were determined using HPLC with electrochemical detector (ECD). The dissolution profiles of two formulations were similar at all dissolution media. In addition, the pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug Surfolase, were -1.64, -3.33 and -0.92% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 $(e.g., \;log\;0.93{\sim}log\;1.05\;and\;log\;0.88{\sim}log\;1.05$ for $AUC_t$, and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Burophil capsule was bioequivalent to Surfolase capsule.

Bioequivalence of SCD Zaltoprofen Tablet to Soleton® Tablet (Zaltoprofen 80 mg) (솔레톤 정(잘토프로펜 80 mg)에 대한 삼천당잘토프로펜 정의 생물학적동등성)

  • Kang, Hyun-Ah;Park, Sun-Ae;Kim, Dong-Ho;Kim, Hwan-Ho;Yun, Hwa;Kim, Kyng-Ran;Yoo, Hee-Doo;Park, Eun-Ja;Cho, Hye-Young;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.3
    • /
    • pp.209-215
    • /
    • 2006
  • Zaltoprofen, (2-(10,11-dihydro-10-oxodibenzo[b,f]thiepin-2-yl)propionic acid) is an NSAID with powerful anti-inflammatory effects as well as an analgesic action on inflammatory pain. The purpose of the present study was to evaluate the bioequivalence of two zaltoprofen tablets, $Soleton^{\circledR}$ (CJ Corp.) and SCD Zaltoprofen (Samchundang Pharmaceutical Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of zaltoprofen from the two zatoprofen formulations in vitro was tested using KP Vlll Apparatus ll method with various dissolution media. Twenty six healthy male subjects, $23.2{\pm}2.26$ years in age and$64.7{\pm}8.08$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After a single tablet containing 80 mg as zaltoprofen was orally administered, blood samples were taken at predetermined time intervals and the concentrations of zaltoprofen in serum were determined using HPLC with UV detector. The dissolution profiles of two formulations were similar in all tested dissolution media. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated, and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Soleton^{\circledR}$ were 6.33, 5.91 and 17.7% for $AUC_t$, $C_{max}$ and untransformed $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g.,log $1.01{\sim}1og\;1.11$ and log $0.928{\sim}1og\;1.18$ for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating SCD Zaltoprofen tablet was bioequivalent to $Soleton^{\circledR}$ tablet.

The Concepts of Weight Control and Dietary Behavior in High School Seniors (고등학교 3학년생의 체중조절에 대한 인식과 관련 식행동 분석)

  • Chung, Hye-Kyung;Lee, Hae-Young
    • Journal of Nutrition and Health
    • /
    • v.43 no.6
    • /
    • pp.607-619
    • /
    • 2010
  • The purpose of this study was to identify the concepts of body image, weight control and food behavior in 520 Korean high school seniors from Seoul and Gyeonggi Province. A questionnaire survey was conducted to investigate body image, concern of weight control, experience of weight control, the first time to try weight control, plan for weight control, reasons of weight control and food behaviors related with weight control. Anthropometric parameters such as weight and height were measured. Finally, data from 497 high school seniors were used for statistical analysis. The results were as follows. Many subjects had misperceptions. Among the subjects who perceived themselves as 'fat', 57.8% were normal weight and 0.5% underweight. Among the subjects who perceived themselves as 'thin', 59.5% were normal weight, 0.9% overweight and 0.9% obese. Girls were more concerned about weight control than boys (4.20 vs. 3.66). Weight loss had been experienced by 61.5% of the subjects and weight gain by 12.8%. First weight control was attempted by 71.3% of the subject at high school and by 28.7% at middle school. The majority of subjects planned for weight control before their freshman year. The boys choose 'health' as the primary reason for weight control, whereas the girls chose 'good appearance'. The total score of food behaviors varied significantly according to BMI. Overweight and obese subjects had more desirable food behaviors than normal weight and underweight subjects (24.00, 24.06 vs. 21.92, 21.52). However, total scores of food behaviors showed no variation according to sex, weight control attempt and body image. In conclusion, the high school seniors had misconceptions about body image and weight control. They were exposed to a high risk of inappropriate weight control and food behaviors. Therefore, proper nutritional education programs need to be developed for high school seniors to prevent nutrition problems related to weight control and to maintain desirable food behaviors.

The Effect of Cyclic Load on Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction (전방십자인대 재건시 이식건의 대퇴골측 고정에 대한 주기성인장부하의 효과)

  • Song Eun-Kyoo;Kim Jong Seok
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.1
    • /
    • pp.28-36
    • /
    • 2003
  • Purpose: To determine and to compare the effects of cyclic loading on the fixation strength of different femoral fixation methods in ACL reconstruction. Materials and Methods: Biomechanical test using an Instron(R) machine (Model No.5569. Mass, U.S.A) were carried out to compare the pull out strength of six different femoral fixation techniques after a cyclic loading in 72 Yorkshire pig knees. The graft-bone complex was cyclically loaded between 30N and 150N at 50 mm/min rate for 1000 cycles and maximal tensile testing was performed. A preload of 30N was applied to the graft along the axis of the tunnel 15 minutes. ANOVA and the Duncan multiple comparison test was used for the statistical analysis. Results: The mean maximum tensile strength of femoral fixation before and after the cyclic loading test were 1003.4$\pm$145N and 601.1$\pm$154N in hamstring-LA screw(R) group, 595.5$\pm$104N and 360.7$\pm$56N in hamstring-Bioscrew(R) group, 1431.7$\pm$135N and 710.7$\pm$114N in hamstring-Semifix(R) group, 603.6$\pm$54N and 459.1$\pm$46N in hamstring-Endobutton(R) fixation group, 1067.4$\pm$145 and 601.8$\pm$134N in the BPTB-Titanium interference screw group, and 987.1$\pm$168N and 588.7$\pm$124N in the BPTB-Bioscrew(R) group. And these data illustrated that cyclic loading reduces the maximum tensile strength by 40 $\%$, 39 $\%$, 50 $\%$, 24 $\%$, 44 $\%$, 40 $\%$ respectively. Conclusions: With the results of these experiments it should be emphasized that rehabilitation exercises after anterior cruciate ligament reconstruction should be executed with precaution as the repetitive flexion and extension of the knee would compromise the maximum tensile strength of the graft tendon.

  • PDF