• Title/Summary/Keyword: statistical confidence

Search Result 1,002, Processing Time 0.031 seconds

The likelihood of achieving pregnancy through timed coitus in young infertile women with decreased ovarian reserve

  • Koo, Hwa Seon;Song, In Ok;Cha, Sun Hwa;Park, Chan Woo;Kim, Hye Ok
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.45 no.1
    • /
    • pp.31-37
    • /
    • 2018
  • Objective: To evaluate the pregnancy rate and time to pregnancy after timed coitus with or without superovulation in infertile young women younger than 35 years old with low serum $anti-M{\ddot{u}}llerian$ hormone (AMH) levels ( < 25th percentile). Methods: A total of 202 patients younger than 35 years old were recruited retrospectively between 2010 and 2012. Ninety-eight women had normal serum AMH levels (25-75th percentile), 75 women had low serum AMH levels (5th ${\leq}$ & < 25th percentile) and 29 women had very low serum AMH levels ( < 5th percentile), according to reference values for their age group. Results: The clinical pregnancy rate was positively associated with AMH levels, but this trend did not reach statistical significance (43.9% vs. 41.3% vs. 27.6% in the normal, low, and very low AMH groups, respectively). The time to pregnancy was longer in the very low AMH group than in the normal AMH group ($13.1{\pm}10.9months$ vs. $6.9{\pm}6.1months$, p= 0.030). The cumulative live birth rate over 18 months was lower in the very low AMH group than in the normal AMH group, with marginal significance (20.0% vs. 55.9%, p= 0.051). The duration of infertility was negatively correlated with achieving pregnancy (odds ratio, 0.953; 95% confidence interval, 0.914-0.994; p= 0.026). Conclusion: Conservative management, such as timed coitus with or without superovulation, should be considered in young patients who have low ovarian reserve without any infertility factors. However, for women with a long duration of infertility or very low serum AMH levels, active infertility treatment should be considered.

Bioequivalence of Tigrin Capsule to Disgren Capsule (Triflusal 300 mg) (디스그렌 캅셀(트리플루살 300 mg)에 대한 티그린 캅셀의 생물학적 동등성)

  • Kim, Soo-Jin;Shim, Young-Sun;Son, Sun-Mi;Lim, Dong-Koo;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.29 no.4
    • /
    • pp.355-360
    • /
    • 1999
  • Triflusal is a new antithrombotic agent which inhibits both platelet cyclooxygenase and c-AMP phosphodiesterase activity. The purpose of the present study was to evaluate the bioequivalence of two triflusal capsules, $Disgren^{TM}$ (Myung-In Pharmaceutical Co., Ltd.) and $Tigriri^{TM}$ (Hana Pharmaceutical Co., Ltd.) according to the guidelines of Korea Food and Drug Administration (KFDA). Eighteen normal male volunteers, $22.94{\pm}1.83$ in age and $63.7l{\pm}10.43$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After one capsule containing 300 mg of triflusal was orally administered, blood was taken at predetermined time intervals and the concentrations of triflusal in serum were determined using HPLC method with UV detector. Pharmacokinetic parameters such as $AUC_t$ $C_{max}$ and $T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters. The results showed that the differences in $AUC_t$ $C_{max}$ and $T_{max}$ between two capsules were -0.30%, 0.81 % and -3.03%, respectively when calculated against the $Disgren_{TM}$ capsule. The powers $(1-{\beta})$ for $AUC_t$ $C_{max}$ and $T_{max}$ were 98.29%,84.73% and 81.02%, respectively. Minimum detectable differences $({\Delta})$ at ${\alpha}=0.1$ and $1-{\beta}=0.8$ were all less than 20% (e.g., 12.91%, 18.46% and 19.65% for $AUC_t$ $C_{max}$ and $T_{max}$ respectively). The 90% confid,ence intervals were all within ${\pm}20%$(e.g., $-8.97{\sim}8.37$, $-11.58{\sim}13.22$ and $-16.23{\sim}10.17$ for $AUC_t$ $C_{max}$ and $T_{max}$, respectively). All of the above parameters ($1-{\beta}, {\Delta}$ and 90% confidence intervals) met the criteria of KFDA for bioequivalence, indicating that $Tigriri^{TM}$ capsule is bioequivalent to $Disgren^{TM}$ capsule.

  • PDF

Bioequivalence of Hana Ondansetron Tablet to Zofran Tablet (Ondansetron 8 mg) (조프란 정(온단세트론 8 mg)에 대한 하나 온단세트론 정의 생물학적 동등성)

  • Cho, Hea-Young;Kim, Soo-Jin;Shim, Young-Sun;Lim, Dong-Koo;Oh, In-Joon;Moon, Jai-Dong;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.30 no.3
    • /
    • pp.213-218
    • /
    • 2000
  • Ondansetron is a potent, highly selective 5-hydroxytryptamine3(5-HT3) receptor- antagonist, for the management of nausea and vomiting induced by cytotoxic chemotherapy and radiography, and the treatment of post-operative nausea and vomiting. The purpose of the present study was to evaluate the bioequivalence of two ondansetron tablets, $Zofran^{TM}$, (Glaxo Wellcome Korea Ltd.) and Hana ondansetron (Hana Pharmaceutical Co., Ltd.), according to the guidelines of Korea Food and Drug Administration (KFDA). Eighteen normal male volunteers, $23.56{\pm}1.79$ year in age and $67.35{\pm}8.35\;kg$ in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After one tablet containing 8 mg of ondansetron was orally administered, blood was taken at predetermined time intervals and the concentrations of ondansetron in serum were determined using HPLC with UV detector. Pharmacokinetic parameters such as $AUC_t,\;C_{max}\;and\;T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters. The results showed that the differences in $AUC_t,\;C_{max}\;and\;T_{max}$ between two tablets were 7.53%, -0.23% and -3.92%, respectively when calculated against the $Zofran^{TM}$, tablet. The powers $(1-{\beta})$ for $AUC_t,\;C_{max}\;and\;T_{max}$ were above 99.00%, above 99.00% and 84.99%, respectively. Minimum detectable differences $(\Delta)\;at\;{\alpha}=0.1\;and\;1-{\beta}=0.8$ were all less than 20% (e.g., 12.25%, 10.88% and 18.37% for $AUC_t,\;C_{max}\;and\;T_{max}$, respectively). The 90% confidence intervals were all within ${\pm}20%$ (e.g., $-0.70{\sim}15.76,\;-7.53{\sim}7.08\;and\;-16.27{\sim}8.42\;for\;AUC_t,\;C_{max}\;and\;T_{max}$, respectively). All of the above parameters met the criteria of KFDA for bioequivalence, indicating that Hana ondansetron tablet is bioequivalent to $Zofran^{TM}$, tablet.

  • PDF

Bioequivalence of Neuracetam Tablet to Neuromed Tablet (Oxiracetam 800 mg) (뉴로메드정(옥시라세탐 800 mg)에 대한 뉴라세탐정의 생물학적동등성)

  • Choi, Sung-Up;Kim, Jong-Seok;Yoon, Mi-Kyeong;Kim, Jung-Il;Park, Seok;Han, Sang-Beom;Lee, Jae-Hwi;Choi, Young-Wook
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.3
    • /
    • pp.215-222
    • /
    • 2004
  • The purpose of the present study was designed to evaluate the bioequivalence of two oxiracetam tablets, Neuromed tablet (Korea Drug Co., reference drug) and Neuracetam tablet (Sam Jin Pharmaceutical Co., test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Release of oxiracetam from the tablet in vitro was tested using KP VIII Apparatus II method with various dissolution media (pH 1.2, 4.0, 6.8 buffer solution and water). Twenty-four healthy volunteers, $23.7\;{\pm}\;2.4$ year in age and $68.9\;{\pm}\;6.2$ kg in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was performed. After oral administration of a tablet containing 800 mg of oxiracetam, blood samples were taken at predetermined time intervals and concentrations of oxiracetam in plasma were determined using HPLC-MS-MS. The dissolution profiles of two formulations were very similar at all dissolution media. In addition, pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$ and $C_{max}$ untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug were 0.42%, 0.45% and -12.58% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals for the log transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., $log0.94{\sim}log1.06$ and $log0.90{\sim}log1.07$ for $AUC_t$, and $C_{max}$, respectively), indicating that Neuracetam tablet is bioequivalent to Neuromed tablet. The major pharmacokinetic parameters, $AUC_t$, and $C_{max}$ met the criteria set by KFDA for bioequivalence indicating that Neuracetam tablet is bioequivalent to Neuromed tablet.

Bioequivalence of Cadilan Tablet 12.5 mg to Dilatrend® Tablet 12.5 mg (Carvedilol 12.5 mg) (딜라트렌 정 12.5밀리그람(카르베딜롤 12.5밀리그람)에 대한 카딜란 정 12.5밀리그람의 생물학적동등성)

  • Kim, Se-Mi;Shin, Sae-Byeok;Kim, Ju-Hwan;Kwon, In-Ho;Kim, Yong-Hee;Lee, Sang-No;Cho, Hea-Young;Lee, Yong-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.38 no.6
    • /
    • pp.413-419
    • /
    • 2008
  • Carvedilol, is a nonselective $\beta$-blocking agent and it also has vasodilating properties that are attributed mainly to its blocking activity at ${\alpha}_1$-receptors. The purpose of the present study was to evaluate the bioequivalence of two carvedilol tablets, $Dilatrend^{(R)}$ tablet 12.5 mg (Chong Kun Dang Pharmaceutical Co., Ltd.) and Cadilan tablet 12.5 mg (KyungDong Pharmaceutical. Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of carvedilol from the two carvedilol formulations in vitro was tested using KP VIII Apparatus II method with pH 4.5 dissolution medium. Thirty two healthy male subjects, $25.00{\pm}3.09$ years in age and $70.71{\pm}11.35\;kg$ in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After a single tablet containing 12.5 mg as carvedilol was orally administered, blood samples were taken at predetermined time intervals and the concentrations of carvedilol in serum were determined using HPLC with fluorescence detector. The dissolution profiles of two formulations were similar in the tested dissolution medium. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Dilatrend^{(R)}$ tablet 12.5 mg, were 4.66%, 8.33% and -7.45% for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., $\log\;0.9823{\sim}\log\;1.1042$ and $\log\;1.0132{\sim}\log\;1.1875$ for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Cadilan tablet 12.5 mg was bioequivalent to $Dilatrend^{(R)}$ tablet 12.5 mg.

Influences of Chronic Pain on the Use of Medical Services in South Korea (만성 통증이 한국의 의료 이용 행태에 미치는 영향)

  • Jeong, Eui-Kyun;Kwak, Yeun-Hee;Song, Jae-Seok
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.2
    • /
    • pp.363-369
    • /
    • 2015
  • Chronic pain is one of the leading causes of hospital visits. It not only affects the patients themselves but also has a major negative impact on their families and society. In this study, we investigated epidemiology of musculoskeletal disorders induced chronic pain among general population based on Korea National Health and Nutrition Examination Survey database and also analysed how it influenced on the use of medical services. This study was done by using the data of 5th Korea National Health and Nutrition Examination Survey (KNHANES V), taking aged 20 years and over adults as research subjects. The EuroQoL-5 Dimension Index(EQ-5D) was used as a survey instrument. T-test, chi-square test and multivariate logistic regression were used for statistical analysis. Subjects with chronic pain had a higher likelihood than control group to use medical services(odds ratio : 5.858, confidence interval 3.636-9.438). Controlling for existence of chronic pain, more women were likely to use medical services than men(1.156, 0.707-1.889). Age, gender and household income level did not affect the use of medical services. Proper control of chronic pain is very helpful in improving patient's quality of life and it also accounts for a large proportion in suppressing excessive consumption of medical services. Anesthesia and pain medicine specialists have superior knowledge about analgesics and anticonvulsants than other physicians do and also have specialized skills to perform procedures like nerve blocks in treating chronic pain. Therefore Anesthesia and pain medicine specialists need to play a leading role in managing chronic pain.

A Comparison of Cardiopulmonary Function, RPE, and Blood Lactate following in Wheelchair Treadmill and Arm Ergometer GXT Test through Convergence (융복합을 활용한 휠체어 트레드밀과 암에르고미터 점증부하운동검사 시 심폐기능, 운동자각도 및 젖산농도 비교)

  • Jang, Hong-Young;Kim, Jong-Hyuck
    • Journal of Digital Convergence
    • /
    • v.14 no.9
    • /
    • pp.553-561
    • /
    • 2016
  • The purpose of this study was to compare cardiopulmonary function, RPE(Rating of perceived exertion), and blood lactate when examining the GXT(Graded exercise testing) of wheelchair treadmill and arm ergometer. Participants were 11 wheelchair basketball players with non disability. While examining the GXT of wheelchair treadmill and arm ergometer, cardiorespiratory functional capacity was measured by using $Quarkb^2$ and Polar and RPE was measured through Borg Scale. The lactate analyser, YSI-2000 was used to measure blood lactate level when resting, right after exercise, two minutes, four minutes, six minutes, and ten minutes of recovery. Data was analyzed by paired t-test using SPSS 18.0 program and significance for all statistical analysis was fixed at .05 confidence level(p<0.05). The conclusion of this study is below. First, maximal oxygen uptake which is a factor of cardiopulmonary function showed the highest with arm ergometer, the rate of respiratory exchange showed the highest with wheelchair treadmill, and maximal heart rate showed the highest with wheelchair treadmill. Second, subjective exercise intensity showed the highest with arm ergometer at the end point. Third, blood lactate level showed the highest with arm ergometer right after exercise.

Bioequivalence Evaluation of Lovastatin Tablets (로바스타틴 정제의 생물학적 동등성 평가)

  • Bok, Hae Sook;Kim, Myoung Min;Choi, Kyung Eob
    • Korean Journal of Clinical Pharmacy
    • /
    • v.8 no.2
    • /
    • pp.107-112
    • /
    • 1998
  • Lovastatin is a lipid lowering agent for the treatment of hypercholesterolemia and belongs to a new class of pharmacologic compounds called the 3-hydroxy-3-methylglutaryl coenzyme A (HMG CoA) reductase inhibitors. By competitively inhibiting HMG CoA reductase, lovastatin disrupts the biosynthesis of cholesterol in hepatic and peripheral cells and increases the synthesis of high-density-lipoprotein HDL) receptors. Following oral administration, the lactone ring of lovastatin is hydrolysed to the active inhibitor of HMG CoA reductase, lovastatin acid. Lovastatin is known to have poor oral absorption and wide individual variation. In this study, bioequivalence test of two lovastatin formulations, the test drug ($Lovaload^{TM}$, Chong Kun Dang Pharmaceutical Co.) and the reference drug ($Mevacor^{TM}$, Chung Wae Pharmaceutical Co.) were conducted according to the guidelines of Korea Food and Drug Administration (KFDA). A total of 18 healthy male volunteers, $31.90\pm3.60$ years old and $72.17\;7.88$ kg of body weight in average, were evaluated in a randomized crossover manner with a 2-week washout period. Concentrations of lovastatin acid in plasma were measured upto 12 hours following a single oral administration of eight tablets (20 mg of lovastatin per tablet) by high-performance liquid chromatography with UV detection at 238 nm. The area under the concentration-vs-time curve from 0 to 12 hours $(AUC_{0-12h})$ was calculated by the trapezoidal summation method. The statistical analysis showed that there are no significant differences in $AUC_{0-12h),\;C_{max}\;and\;T_{max}$ between the two formulations ($6.72\%,\;1.52\%,\;and\;0.88\$, respectively). The least significant differences between the formulations at $\alpha$=0.05 were less than $20\%\;(11.65\%,\;19.73\%,\;and\;14.81\%\;for\;AUC_{0-12h},\;C_{max}\;and\;T_{max}$, respectively). The $90\%$ confidence intervals for these parameters were also within $\pm20\%\;(-1.50{\leq}{\delta}{\leq}15.00$, $-12.50{\leq}{\delta}{\leq}15.50,\;and\;-9.64{\leq}{\delta]{\leq}11.40{\leq}\;for\;\;AUC_{0-12h}$ ,$C_{max}\;and\;T_{max}$, respectively). In conclusion, the new generic product $Lovaload^{TM}$ was proven to be bioequivalent with the reference drug.

  • PDF

Bioequivalence Evaluation of Pylocin Tablet to Klaricid Tablet (Clarithyomycin, 250 mg) (클래리시드 정(클래리스로마이신 250 mg)에 대한 파이로신 정의 생물학적 동등성)

  • Cho, Hea Young;Kim, Soo Jin;Sim, Young Sun;Lim, Dong Koo;Oh, In Joon;Lee, Yong Bok;Moon, Jai Dong
    • Korean Journal of Clinical Pharmacy
    • /
    • v.10 no.1
    • /
    • pp.13-18
    • /
    • 2000
  • The bioequivalence of two clarithromycin tablets, the $Klaricid^{TM}$ (Ciba-Geigy Korea Ltd.) and the $Pylocin^{TM}$ (Kyungdong Pharmaceutical Co., Ltd.), was evaluated according to the Korean Guidelines for Bioequivalence Test (KGBT 1998). Sixteen healthy male volunteers ($20\sim26$ years old) were randomly divided into two groups and a randomized $2\times2$ cross-over study was employed. After one tablet containing 250 mg of clarithromycin was orally administered, blood sample was taken at predetermined time intervals, and the concentrations of clarithromycin in serum were determined using high-performance liquid chromatographic method with electrochemical detector. The pharmaco-kinetic parameters (area under the concentration-time curve: $AUC_t$, maximum concentration; $C_{max}$ and time to maximum concentration; $T_{max}$) were calculated and analysis of variance (ANOVA) was utilized for the statistical analysis of parameters. The results showed that the differences in $AUC_t,\;C_{max}\;and\;T_{max}$ between two tablets based on $Klaricid^{TM}$ tablet were $-0.22\%,\;-0.48\%\;and\;-1.63\%$, respectively. The powers $(1-\beta)\;for\;AUC_t,\;C_{max}\;and\;T_{max}\;were\;99.07\%,\;88.15\%\;and\;99.99\%$, respectively. Detectable differences $(\Delta)\;and\;90\%$ confidence intervals ($\alpha$=0.10) were all less than $\pm20\%$ All the parameters above met the criteria of KGBT 1998, indicating that $Pylocin^{TM}$ tablet is bioequivalent to $Klaricid^{TM}$ tablet.

  • PDF

Bioequivalence Test of Rebamipide 100 mg Tablets (레바미피드 100 mg 정제의 새울학적동등성)

  • Kim, Se-Mi;Cho, Hea-Young;Kang, Hyun-Ah;Lee, Yong-Bok
    • Korean Journal of Clinical Pharmacy
    • /
    • v.18 no.1
    • /
    • pp.38-44
    • /
    • 2008
  • Rebamipide, ($\pm$)-2-(4-chlorobenzoylamino)-3-[2(1H)-quinolinon-4-yl] propionic acid, is used for mucosal protection, healing of gastroduodenal ulcers, and treatment of gastritis. It works by enhancing mucosal defense, scavenging free radicals and temporarily activating genes encoding cyclooxygenase-2. The purpose of the present study was to evaluate the bioequivalence of two rebamipide tablets, $Mucosta^{(R)}$ (Korea Otsuca Pharmaceuticals Co., Ltd.) and Mustar (Korean Drug Co., Ltd.), according to the guidelines of the Korea Food and Drug Administration (KFDA). The release of rebamipide from the two rebamipide formulations in vitro was tested using KP VIII Apparatus II method with pH 6.8 dissolution medium. Twenty six healthy male subjects, $23.46{\pm}2.63$ years in age and $66.62{\pm}8.97\;kg$ in body weight, were divided into two groups and a randomized $2{\times}2$ cross-over study was employed. After a single tablet containing 100 mg as rebamipide was orally administered, blood samples were taken at predetermined time intervals and the concentrations of rebamipide in serum were determined using HPLC with fluorescence detector. The dissolution profiles of two formulations were similar in the tested dissolution medium. The pharmacokinetic parameters such as $AUC_t$, $C_{max}$ and $T_{max}$ were calculated, and ANOVA test was utilized for the statistical analysis of the parameters using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. The results showed that the differences between two formulations based on the reference drug, $Mucosta^{(R)}$ were -5.08, 3.52 and -9.71 % for $AUC_t$, $C_{max}$ and $T_{max}$, respectively. There were no sequence effects between two formulations in these parameters. The 90% confidence intervals using logarithmically transformed data were within the acceptance range of log 0.8 to log 1.25 (e.g., log 0.84$\sim$log 1.07 and log 0.90$\sim$log 1.17 for $AUC_t$ and $C_{max}$, respectively). Thus, the criteria of the KFDA bioequivalence guideline were satisfied, indicating Mustar tablet was bioequivalent to $Mucosta^{(R)}$ tablet.

  • PDF