• Title/Summary/Keyword: station class

Search Result 184, Processing Time 0.03 seconds

Evaluation of Electrical Characteristics of Metal Oxide Varistors for Surge Arresters (초고압용 피뢰기 산화아연소자의 전기적 특성 평가)

  • Cho, Han-Goo;Yoon, Han-Soo;Kim, Suk-Soo;Han, Se-won
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.05b
    • /
    • pp.46-49
    • /
    • 2005
  • This paper presents the electrical characteristics of metal oxide varistors for lightning surge arresters. ZnO varistors were fabricated with typical ceramic production methods and two types of varistors were also prepared to be compared. The nominal discharge current and line discharge class of those varistors are $10kA(8/20{\mu}s)$ and class 3, respectively. The diameter of varistors manufactured and prepared were in the range of 61.6~65.0mm and the thickness of those were in the range of 27~42.52mm. The reference and residual voltage were tested and reference and residual voltage per 1mm and the ratio of reference and residual voltage were calculated. The reference voltage per 1mm of varistors manufactured was about 175V/mm but that of A's and B's varistors was nearly 200V/mm. The residual voltage exhibited the same trends as the reference voltage, so the reference and residual voltage per 1mm of domestic varistors should be increased. According to the results of tests, it is thought that if the reference and residual voltage per 1mm were increased to 200V/mm and 330V/mm, domestic ZnO varistors would be possible to apply to the station class arresters in the near future.

  • PDF

Sojourn Times in a Multiclass Priority Queue with Random Feedback

  • Hong, Sung-Jo;Hirayama, Tetsuji
    • Management Science and Financial Engineering
    • /
    • v.2 no.1
    • /
    • pp.123-145
    • /
    • 1996
  • We consider a priority-based multiclass queue with probabilistic feed-back. There are J service stations. Each customer belongs to one of the several priority classes, and the customers of each class arrive at each station in a Poisson process. A single server serves queued customers on a priority basis with a nonpreemptive scheduling discipline. The customers who complete their services feed back to the system instantaneously and join one of the queues of the stations or depart from the system according to a given probability. In this paper, we propose a new method to simplify the analysis of these queueing systems. By the analysis of busy periods and regenerative processes, we clarify the underlying system structure, and systematically obtain the mean for the sojourn time, i.e., the time from the arrival to the departure from the system, of a customer at every station. The mean for the number of customers queued in each station at an arbitrary time is also obtained simultaneously.

  • PDF

DECOMPOSITION APPROXIMATION FOR OPEN QUEUEING NETWORKS

  • Lim, Jong-Seul
    • Journal of applied mathematics & informatics
    • /
    • v.8 no.3
    • /
    • pp.1035-1045
    • /
    • 2001
  • We present two decomposition approximations for the mean sojourn times in open single class queing networks. If there is a single bottleneck station, the approximations are asymptotically exact in both light and heavy traffic. When applied to a Jackson network or an M/G/1 queue, these approximations are exact for all values of the traffic intensity.

Higher fungi of Dagelet Island (Forest Experiment Station) (울릉도의 버섯류)

  • 이용우
    • Journal of Plant Biology
    • /
    • v.2 no.2
    • /
    • pp.22-24
    • /
    • 1959
  • 1. In this paper the author reports on 16 species fo the higher fungi, Which were collected in the Dagelet Island during the periods of October 5-22, 1958. 2. They are Classified as follows : 1. Class, 2 subClasses, 4 orders, 8 families, 13 genera and 16 species. Among them 2 unrecorded species are included.

  • PDF

A novel approach for the design of multi-class reentrant manufacturing systems

  • Yoo, Dong-Joon;Jung, Jae-Hak;Lee, In-Beum;Lee, Euy-Soo;Yi, Gyeong-beom
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.710-715
    • /
    • 2004
  • The design problem of manufacturing system is addressed, adopting the closed queueing network model with multiple loops and re-entrant flows. The entire design problem is divided into two hierarchical sub-problems of (1) determining the station configuration and (2) optimizing the lot constitution; then they are tackled by neighbor search algorithm (NSA) and greedy mean value analysis (GMVA), respectively. Unlike the conventional MVA concerning multi-class closed queueing networks, the GMVA doesn't stick to a fixed lot proportion; rather it tries to find the optimal balance. The NSA, on the other hand, improves the object function value by altering the station configuration successively with its superior neighbor. The moderate time complexity, presented in big-${o}$ notation, enables us to apply the method even to the large-size practical cases, and the CPU time of an enlarged problem can be approximated by the same equation. The validity of our analytic approach is backed up by simulation studies with a widespread simulation package.

  • PDF

A study on the commercialization cause of 2nd class residential area in urban center (도시거점내 제2종 일반주거지역 상업화 확산과 원인 분석)

  • Yoon, Yong-Suk;Yang, Woo-Hyun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2011.04a
    • /
    • pp.147-152
    • /
    • 2011
  • The purpose of this study is to find out the commercialization cause of 2nd class residential area in urban center as basic research to protect urban residential area against the pressure of commercialization. Through the research that are based on literature, field survey and urban planning map, it analysed the commercialization cause of selected two sites under similar urban condition ; to be a nearby subway station and to be a famous commercial street in site, etc. The consequences of this study are summarized as follows ; First the distance between subway station and residential block and residential commercialization are in inverse proportion each other. Second, the corner lot of a block and the access street directly connected collector street are very important factors to spread commercialization to residential area. Finally, nevertheless first and second results, there is square zone which is very high rate of commercialization within one regardless the distance between subway and residential block. the maximum range of square zone is assumed about 250 meter based on case study.

  • PDF

Evaluation of Long Duration Current Impulse Withstand Characteristics of ZnO Blocks for High Voltage Surge Arresters (초고압 피뢰기용 ZnO 소자의 장시간 방전내량 특성 평가)

  • Cho, Han-Goo;Yun, Han-Soo;Kim, Seok-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.4
    • /
    • pp.398-403
    • /
    • 2006
  • This paper describes the evaluation of the long duration current impulse withstand characteristics of ZnO blocks for high voltage surge arresters. Four ZnO varistors were manufactured with the general ceramic production method and the long duration current impulse withstand test, electrical uniformity evaluation test and microstructure observation were performed. All varistors exhibited high density, which was in the range of $5.42{\sim}5.46g/cm^3$. In the electrical properties, the reference voltage of samples was in the range of $5.11{\sim}5.25\;kV$ and the residual voltage was in the range of $8.314{\sim}8.523\;kV$. In the long duration current impulse withstand test, sample No.2 and No.3 failed at the 2nd and 4th shot of series impulse currents, respectively, but the rest survived 18 shots during the test. Before and after this test, the variation ratio of the residual voltage of samples survived was below 0.5 %, which was in the acceptance range of 5 %. According to the results of the test, it is thought that if the soldering method is improved, ZnO varistors would be possible to apply to the high voltage arresters like the station class and transmission line arresters in the near future.

Electrical Characteristics and Performance Evaluation with Manufacturing Process of Zinc Oxide Varistors (산화아연소자의 성형공정에 따른 전기적 특성과 성능평가)

  • Cho, Han-Goo;Yoon, Han-Soo;Kim, Suk-Soo;Choi, In-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.11
    • /
    • pp.1061-1066
    • /
    • 2006
  • This paper presents the electrical characteristics with manufacturing process and performance evaluation of high performance zinc oxide varistors. ZnO varistors were fabricated with typical ceramic production methods with different thickness and the structural and electrical characteristics of ZnO varistors were investigated. All varistors exhibited high density, which was in the range of $5.41{\sim}5.49g/cm^3$. In the electrical properties, the reference voltage increased in the range of $4.410{\sim}5.250kV$ with increasing their thickness and the residual voltage exhibited the same trends as the reference voltage. In the long duration current impulse withstand test, E-2 and F-1 samples failed at the two and four shots of impulse current, respectively, but E-1 and F-2 samples survived 18 shots during the test. Before and after this test, the variation ratio of residual voltage of E-1 and F-2 samples were -0.34 % and 0.05 %, respectively, which were in the acceptance range of 5 %. According to the results of tests, it is thought that if the fabrication process such as insulating coating, sintering condition, and soldering method is improved, these ZnO varistors would be possible to apply to the station class arresters in the near future.

Design & characteristics of impulse current test system for station class(up to class 5) (송변전급(up to class 5) Impulse current test system의 설계 및 특성)

  • Kim, Seok-Sou;Choi, Ike-Sun;Kang, Young-Sik;Park, Byung-Rak;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1146-1149
    • /
    • 2004
  • A new developed impulse current test system(100kV, 250kJ)is presented, which can carry out all impulse current and performance tests on surge arrester sections with rated voltage up to 12kV according to IEC 60099-4(2001). The maximum achievable peak value is 200kA for the impulse current $4/10{\mu}s$ and 60kA for the $30/80{\mu}s$ and $8/20{\mu}s$. The long duration current impulse is realized from class 1 to class 5. The digital transient recorder(4 channels 60MS/S 10bit) is used for measuring AC voltage, impulse current, reference voltage and leakage current. The complex control, measuring, evaluation and data storage system is controlled by one industrial PC system.

  • PDF

Environmental Survey and Properties of Establishable Grassland (초지조성 대상지 환경조사)

  • Choi, S.S.;Hwang, S.J.;Seo, S.;Lee, J.Y.;Jung, Y.K.
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.5 no.2
    • /
    • pp.93-99
    • /
    • 1985
  • All soil characteristics for 10,077ha of establishable grassland in 1984 were statistically summarized. Soils could be classified into 5 of Order, 7 Suborder, 11 Great group, 28 Subgroup, and 105 Series by the new comprehensive classification system. Distribution rate of farm houses managed the extent magnitude of 3.0ha was 70.8% and its total extent was 35.9%. Extent rate of uncultivated method was 71.3%. These soils were distributed with regard to hilly land and mountain foot slope at, 82.0, and to 0-30% slope at 66.9%. Soil texture was light such as sandy loam to loam at 85.0%, available soil depth more than 20cm at 97.8%, and gravel content less than 35% at 98.4%. Soil would be distributed in 67.3 of first class, 29.7 second class, and 3.0% third class for suitability. Mean values of pH, available $P_2O_5$, OM, Ca, Mg and K for topsoil were 5.6, 31ppm, 3.2%, 2.23me/100gr, 1.05me/100gr, and 0.37me/100gr, respectively.

  • PDF