• Title/Summary/Keyword: static studies

Search Result 927, Processing Time 0.026 seconds

Performance of Transaction Processing Schemes in Mobile Database Systems (이동 데이터베이스체계에서 거래처리 기법의 성능)

  • 최용구
    • Journal of the Korea Society of Computer and Information
    • /
    • v.4 no.2
    • /
    • pp.70-79
    • /
    • 1999
  • In mobile database system, transactions processing schemes address in ones using a static coordinator and coordinator migration. This apply coordinator migration mechanism which perform the transaction in new database server when posed to be the transaction service handoff. That apply static coordinator mechanism which perform the transaction in database server to begin the transaction when posed to be the transaction service handoff. In this paper, a scheme-independent simulation model has been developed in order to support comparative performance studies of mobile transaction processing schemes. And this paper describes the model in detail and presents simulation results which were obtained for what it believe to be the performance evaluation of the mobile transaction processing schemes. Finally, the mobile transaction processing schemes will improve system performance by minimizing the transmission of message for processing the transactions in mobile database system.

  • PDF

Numerical Simulation of Ground Heat Exchanger Embedded Pile Considering Unsaturated Soil Condition (불포화 지반 조건을 고려한 파일 매입형 열교환기의 수치해석)

  • Choi, Jung-Chan;Lee, Seung-Rae
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.213-220
    • /
    • 2010
  • This study presents a numerical simulation model of vertical ground heat exchangers, considering unsaturated hydro static ground conditions induced by the ground water table fluctuation. Heat transfer in ground and grout is modeled by a 3-D FEM transient conductive heat transfer model, where heat transfer between circulating fluid and heat exchanging pipe is treated as 1-D quasi steady state forced convective elements. To take into account the unsaturated ground condition, soil thermal conductivity and heat capacity which are dependent on the matric suction are applied to ground elements. Parametric studies considering various ground water table conditions are conducted to investigate the influence of unsaturated hydro static ground condition on the mean heat exchange rate of ground heat exchanger. Simulation results considering water table fluctuation show 60~100% of mean heat exchange rate for a saturated soil condition and 125~208% of that for a dry soil condition. Thus consideration of unsaturated soil condition is substantially recommended for more accurate design and performance evaluation for ground heat exchangers.

  • PDF

The study on the Analysis of Useful Daylight Illuminance in rural standard house model - By Dynamic Daylight Simulation Using Weather Data - (농어촌주택 표준설계의 유용조도 분석에 관한 연구 - 기상데이터 기반 동적 자연채광 시뮬레이션을 기반으로 -)

  • Yun, Young Il;Song, Jeong Suk;Lee, Hyo Won
    • KIEAE Journal
    • /
    • v.11 no.1
    • /
    • pp.47-55
    • /
    • 2011
  • Daylight is highly beneficial for improving the indoor environmental quality and reducing building energy consumption, daylighting applications are scarcely considered, especially during the Rural standard house models design process, because of lack of previous studies on elderly-light environment and complex simulation process. Therefore, daylighting process were performed using ECOTECT, which has various advantage such as easy user interface and simple simulation processes. Moreover, dynamic daylight simulation were performed using whether data. Static simulation are performed to compute static metrics such as daylight factor, whereas dynamic simulation are performed for dynamic metrics such as daylight autonomy and useful daylight illuminance using annual weather data On the basis of daylight autonomy and useful daylight illuminance analysis result, variations in annual daylight performances. A parametric and regression analysis of the window-to-wall ratio and visible transmittance showed that daylight factor, daylight autonomy increased with window-to-wall ratio and visible transmittance. It can be concluded that this new daylight criteria. useful daylight illuminance, will enable architect to obtain better fenestration design.

Effects of a Static Synchronous Series Compensator (SSSC) Based on a Soft Switching 48-Pulse PWM Inverter on the Power Demand from the Grid

  • Ustun, Taha Selim;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • v.10 no.1
    • /
    • pp.85-90
    • /
    • 2010
  • In this paper the effects of a Static Synchronous Series Compensator, which is constructed with a 48-pulse inverter, on the power demand from the grid are studied. Extensive simulation studies were carried out in the MATLAB simulation environment to observe the compensation achieved by the SSSC and its effects on the line voltage, line current, phase angle and real/reactive power. The designed device is simulated in a power system which is comprised of a three phase power source, a transmission line, line inductance and load. The system parameters such as line voltage, line current, reactive power Q and real power P transmissions are observed both when the SSSC is connected to and disconnected from the power system. The motivation for modeling a SSSC from a multi-pulse inverter is to enhance the voltage waveform of the device and this is observed in the total harmonic distortion (THD) analysis performed at the end of the paper. According to the results, the power flow and phase angle can be controlled successfully by the new device through voltage injection. Finally a THD analysis is performed to see the harmonics content. The effect on the quality of the line voltage and current is acceptable according to international standards.

A Study on a Substation Static Load Model Including the Mobility of a Railway Load (철도 부하의 이동성을 반영한 변전소 정태부하모델링 수립에 대한 연구)

  • Chang, Sang-Hoon;Youn, Seok-Min;Kim, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.2
    • /
    • pp.315-323
    • /
    • 2015
  • Nowadays, it is expected that mobility loads such as electric railways and electric vehicles will be penetrated gradually and affect on the power system stability by their load characteristics. Various researches have been carried out about electric vehicles for the recent decade though the load of electric railway could be forecasted because of the specified path and timetable, is a field with a long historic background. Some precise 5th polynomial equations are required to analyze the power system stability considering mobility load to be increased in the immediate future while the electric railway dispatching simulator uses load models with constant power and constant impedance for the system analysis. In this paper, seasonal urban railway load models are established as the form of 5th polynomial equations and substation load modeling methods are proposed merging railway station load models and general load models. Additionally, load management effects by the load modeling are confirmed through the case studies, in which seasonal load models are developed for Seoul Subway Line No. 2, Gyeongui Line and Airport Railroad and the substation load change is analyzed according to the railway load change.

Proteomic analysis of murine peritoneal macrophages after in vitro exposure to static magnetic field

  • Soon, Eun-Jae;Woong, Ko-Dae;Geun, Kwak-Young
    • Proceedings of the Korean Society of Applied Pharmacology
    • /
    • 2003.11a
    • /
    • pp.113-113
    • /
    • 2003
  • A number of studies have demonstrated recently nonthermal interactions of extremely low frequency electromagnetic fields with cellular systems, such as the cells of the immune system. Particular concern came from epidemiological findings, which correlated environmental exposure of human body to weak electromagnetic fields with an elevated risk for developing certain type of leukemias and cancers. Several home/environmental sources generating extremely low frequency electromagnetic fields, such as 50 - 60 Hz high-voltage transmission lines, video display terminals, electric blankets, clinical nuclear magnetic resonance imaging procedures, etc., may interact with the human body. In this study we examined the effects of static magnetic fields (SMF) on the phagocytosis of the murine peritoneal macrophages (C57BL/6). The cells were exposed in vitro for 24 h at 37$^{\circ}C$ to 400 G SMF. The phagocytic activity of peritoneal macrophages was determined with a luminometer. Exposure to the SMF decreased phagocytic activity of murine peritoneal macrophages. In order to provide a more exact mechanism of the phenomenon, we analyzed peritoneal macrophages for alteration in their proteomes. The expression levels of these 5 proteins were increased in the SMF. In total 5 proteins which were differentially expressed in the SMF compared with control group were identified. The expression levels of these 5 proteins were increased in the SMF.

  • PDF

Evaluation of Fracture Toughness of Pressure Vessel Steel Using Charpy Impact Test Specimens (Charpy 충격시편을 이용한 압력용기 재료의 파괴인성 측정)

  • Han, Dae-June;Park, Sun-Pil
    • Nuclear Engineering and Technology
    • /
    • v.19 no.1
    • /
    • pp.1-9
    • /
    • 1987
  • The fracture toughness of SA 533 Grade B Class 1 steel has been studied with the Charpy impact test specimens in a range of temperature between -4$0^{\circ}C$ and 288$^{\circ}C$. The dynamic fracture toughness is measured by the instrumented precracked Charpy impact test while the static fracture toughness is by the 3-point bend test based on the unloading compliance method. The results are compared with the data obtained from the large specimens. It is known through the studies that temperature dependence of the appropriate (a low bound) value of the fracture toughness can be estimated by taking the static fracture toughness above the transition temperature and the dynamic fracture toughness below the temperature and it is also shown that the tests are satisfied with the requirements of ASTM E 813 when the side-groove is more than 14%.

  • PDF

Investigations of H-Darrieus rotors for different blade parameters at low wind speeds

  • Sengupta, Anal R.;Biswas, Agnimitra;Gupta, Rajat
    • Wind and Structures
    • /
    • v.25 no.6
    • /
    • pp.551-567
    • /
    • 2017
  • Studies of unsymmetrical blade H-Darrieus rotors at low wind speeds in terms of starting time, static torque, and power performances for different blade parameters: thickness-to-chord (t/c), camber position, and solidity are scarce. However these are required for knowing insights of rotor performances to obtain some design guidelines for the selection of these rotors. Here, an attempt is made to quantify the effects of these blade parameters on the performances of three different H-Darrieus rotors at various low wind streams. Different blade profiles, namely S815, EN0005 (both unsymmetrical), and NACA 0018 (symmetrical blade for comparison) are considered. The rotors are investigated rigorously in a centrifugal blower apparatus. Firstly the dynamic and static performances of the rotors are evaluated to determine the best performing rotor and their optimum solidity. Generalised performance equations are developed based on selected blade parameters which are validated for the unsymmetrical rotors. Further, the starting time is quantified with respect to the rotor inertia to determine the suitable range of inertia that helps the unsymmetrical blade rotor to self-start earlier than the symmetrical one. This study can work as a benchmark for the selection of optimum blade parameters while designing an unsymmetrical blade rotor at low wind speeds.

EFFICIENT STRETCHING METHODS : A Review (효과적인 스트레칭 방법의 연구 고찰)

  • Han, Sang-Wan;Kim, Yong-Nam
    • Journal of Korean Physical Therapy Science
    • /
    • v.5 no.3
    • /
    • pp.675-689
    • /
    • 1998
  • The purpose of this study was to determine the efficient way of stretching technique from three methods, and of stretching duration and frequency. Sretching is known to improve musculotendinous flexibility and joint suppleness, and employed in many warm-up routines during physical activities and athletic performances. The benefits and the rationale of stretching have been reviewed. Many authors agree that, for the best results, static stretching has to be held for approximately 30 sec. in a trial, three trials in a session, at least three times a week for four weeks. Further clinical studies are required for elucidating more informations on this subject.

  • PDF

Prediction on Ultimate Vertical and Horizontal Bearing Capacity of Steel Pipe Piles by Means of PAR (PAR에 의한 강관 말뚝의 극한 수직 및 수평 지지력 예측)

  • 최용규
    • Geotechnical Engineering
    • /
    • v.13 no.4
    • /
    • pp.13-24
    • /
    • 1997
  • A predicting method for ultimate vertical and horizontal bearing capacity by means of PAR(Pile Analysis Routines) was suggested. Based on the static pile load test data, case studies by means of PAR were performed. Ultimate pile capacity predicted by PAR was within 15% error range of that determined by stairs pile load tests. Also, the results of static pile load test, statnamic tests and PDA data performed on pipe piles were compared and, by using PAR, ultimate pile capacity was determined. Distributions of atrial pile load could be predicted and load transfer analysis could be done approximately by those distributions.

  • PDF