• 제목/요약/키워드: static preload

검색결과 35건 처리시간 0.021초

진공예압형 다공질 공기베어링의 압력분포 및 성능해석 (Analysis on the Static Performance of Vacuum-Preloaded Porous Air Bearings)

  • 김경호;박천홍
    • 한국정밀공학회지
    • /
    • 제30권12호
    • /
    • pp.1327-1333
    • /
    • 2013
  • Air bearings are widely used in precision stages because of low friction and high motion accuracy, however, they suffer from low stiffness in comparison with rolling bearings or hydrostatic bearings. So, several preloading methods using weight, magnet and vacuum force, and opposing pads have been used to increase the stiffness of the air bearings. In this paper, pressure distributions of the vacuum preloaded porous air bearings are calculated using the proposed method. And then, the load capacity and stiffness are analyzed. For the vacuum preloaded air bearings, the stiffness is increased owing to reduced bearing clearance by vacuum force. The simulation results indicate that variation of vacuum pressure with clearance in the vacuum pocket gives rise to low stiffness, so the vacuum pocket should be designed for pressure to be constantly maintained regardless of the bearing clearance by means of large effective pumping speed.

볼트결합부를 포함한 구조물의 정적 및 동적 해석을 위한 유한요소 모델링 (Finite Element Modeling for Static and Dynamic Analysis of Structures with Bolted Joints)

  • 권영두;구남서;김성윤;조민호
    • 대한기계학회논문집A
    • /
    • 제26권4호
    • /
    • pp.667-676
    • /
    • 2002
  • Many studies on the finite element modeling for bolted joints have proceeded, but the structures with bolted joints are complicated in shape and it is difficult to find out the characteristics according to joint condition. Usually, experimental methods have been used for bolted joint analysis. A reliable and practical finite element modeling technique for structure with bolted joints is very important for engineers in industry. In this study, three kinds of model are presented; a detailed model, a practical model and a simple model. The detailed model is modeled by using 3-D solid element and gap element, and the practical model is modeled by using shell element (a portion of bolt head) and beam element (a portion of bolt body), the simple model is modeled by simplifying practical model without using gap elements. Among these models, the simple model has the least degree of freedom and show the effect of memory reduction of 59%, when compared with the detailed model.

Lumbar spine 의 뼈와 Interbody cage의 접촉면에서 기계공학적 민감성 고찰 (The Mechanical Sensitivity at Interfaces between Bone and Interbody Cage of Lumbar Spine Segments)

  • 김용
    • 대한의용생체공학회:의공학회지
    • /
    • 제21권3호
    • /
    • pp.295-301
    • /
    • 2000
  • 뼈의 성장에 미치는 많은 요소들 중에서 implant의 상대적인 미세운동(relative micromotion)은 뼈의 implant와의 접합을 방해하는 것으로 알려져 왔다. 그런데 이러한 상대적인 운동 및 spinal stability에 직접적으로 영향을 주는 하중조건, spinal material의 물성치, spinal geometry 및 뼈와 implant의 접촉면에서의 마찰계수를 고려하기 위하여, 하나의 titanium interbody cage 가 삽입된 human lumbar segments (L4-L5)의 유한요소 모델이 개발되었다. 이러한 유한요소 모델의 해석을 통하여 상대적인 미세운동, Posterior의 수직적인 변위, von Mises 응력 및 마찰력이 예측되었다. Cancellous bone. annulus fibers 및 ligaments의 기계적인 물성치의 감소 또는 접촉면에서의 마찰계수의 감소는 상대적인 미세운동 (relative micromotion or slip distance)을 증가 시켰다. 접촉면에서의 normal force는 뼈의 밀도 (cancellous bone density) 가 감소하거나 접촉마찰계수가 증가하면 감소했다. 특히 하중조건에 있어서, compressive preload에 대한 torsion의 추가는 접촉면의 anterior부위에서 상대적인 미세운동을 증가 시켰다. 하지만 디스크면적이 증가할수록 상대적인 미세운동은 감소했다. 결론적으로, 접촉면의 기계공학적 거동 (Relative micromotion, stress response, posterior axial displacement and contact normal force)은 접촉면의 마찰계수 뼈의 밀도, 하중조건 및 노화에 따른 형상/물성의 변화에 매우 민감함을 보이고있다.

  • PDF

Biomechanical stress and microgap analysis of bone-level and tissue-level implant abutment structure according to the five different directions of occlusal loads

  • Kim, Jae-Hoon;Noh, Gunwoo;Hong, Seoung-Jin;Lee, Hyeonjong
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.316-321
    • /
    • 2020
  • PURPOSE. The stress distribution and microgap formation on an implant abutment structure was evaluated to determine the relationship between the direction of the load and the stress value. MATERIALS AND METHODS. Two types of three-dimensional models for the mandibular first molar were designed: bone-level implant and tissue-level implant. Each group consisted of an implant, surrounding bone, abutment, screw, and crown. Static finite element analysis was simulated through 200 N of occlusal load and preload at five different load directions: 0, 15, 30, 45, and 60°. The von Mises stress of the abutment and implant was evaluated. Microgap formation on the implant-abutment interface was also analyzed. RESULTS. The stress values in the implant were as follows: 525, 322, 561, 778, and 1150 MPa in a bone level implant, and 254, 182, 259, 364, and 436 MPa in a tissue level implant at a load direction of 0, 15, 30, 45, and 60°, respectively. For microgap formation between the implant and abutment interface, three to seven-micron gaps were observed in the bone level implant under a load at 45 and 60°. In contrast, a three-micron gap was observed in the tissue level implant under a load at only 60°. CONCLUSION. The mean stress of bone-level implant showed 2.2 times higher than that of tissue-level implant. When considering the loading point of occlusal surface and the direction of load, higher stress was noted when the vector was from the center of rotation in the implant prostheses.

자가관류법에 의한 체외심폐의 혈역학적 변동에 관한 실험적 연구 (The experimental study for hemodynamic changes in the heart-lung preparatio by autoperfusion)

  • 한승세
    • Journal of Chest Surgery
    • /
    • 제22권2호
    • /
    • pp.179-190
    • /
    • 1989
  • The experimental study for extracorporeal preservation of the heart-lung preparation by autoperfusion system was performed in 10 dogs. Under intravenous Pentothal endotracheal anesthesia bilateral thoracotomies were performed. A 24F cannula connected to a plastic reservoir bag located 100 cm above the level of the heart was introduced into the aortic arch. Left subclavian, innominate artery, and descending aorta were ligated and divided. Both vena cavae were ligated and divided after the bag was half filled with blood. A 24F catheter inserted into right atrium and connected to the plastic bag in order to keep constant the preload. The thoracic trachea was intubated and the lungs were ventilated. The heart-lung preparations were removed en bloc and floated in a $34^{\circ}C$ bath of Hartmann solution. The preparations were observed for from 2 hours to 8 hours, with the average of 5.2 hours. Hemodynamic and hematologic variables were measured during preharvest and autoperfusion. The pH revealed severe respiratory alkalosis due to very low $PaCO_2$ during autoperfusion ; $PaO_2$ remained constant for 130-140 mmHg; $A-aDO_2$ increased markedly. The static inspiratory pressure [SIP] at late autoperfusion [6hr] increased significantly as compared with at early autoperfusion [2hr]. There was no difference between white blood cell counts from right atrium and those of left atrium. Heart rates remained constant for 110-120/min; cardiac outputs maintained to approximately 0.6L/min; mean aortic pressures, 75 mmHg; mean pulmonary arterial pressures, 15-18 mmHg; mean right atrial pressures, 9-13 mmHg; mean left atrial pressures, 12 mmHg lower than those of right atrium. Serum Na maintained with normal range during autoperfusion; K increased significantly; Ca decreased progressively. Hemoglobin and hematocrit decreased significantly during autoperfusion. The study demonstrated that stable hemodynamics could be maintained throughout the experiment and the preparation of the lung seemed to be inadequate, especially after 3-4 hours, such as high $A-aDO_2$, increased SIP, and scattered atelectasis and edema in their gross appearances.

  • PDF