• Title/Summary/Keyword: static measurements

Search Result 414, Processing Time 0.02 seconds

Measurements of Dynamic Properties of Rock Cores Using Free-Free Resonance Tests. (자유단 공진 시험을 이용한 암시편의 동적 물성치 측정)

  • 목영진
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.75-80
    • /
    • 1998
  • Dynamic measurements are used rather sparingly to determine the elastic moduli of rock cores and modulus values are not much utilized in design practices. The reason seems to result from the general perception that values obtained by dynamic measurement are much higher (about 10 time) than those determined statically. This paper presents results from dynamic and static tests on rock cores. One of the findings is that both moduli determined by statically and dynamically on a solid rock core agrees well at the same-strain. At different strain levels, the ratio between dynamic and static modult widely varies depending upon micro-cracks and discontinuites of rock cores.

  • PDF

Performance assessment of bridges using short-period structural health monitoring system: Sungsu bridge case study

  • Kaloop, Mosbeh R.;Elsharawy, Mohamed;Abdelwahed, Basem;Hu, Jong Wan;Kim, Dongwook
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.667-680
    • /
    • 2020
  • This study aims at reporting a systematic procedure for evaluating the static and dynamic structural performance of steel bridges based on a short-period structural health monitoring measurement. Sungsu bridge located in Korea is considered as a case study presenting the most recent tests carried out to examine the bridge condition. Short-period measurements of Structural Health Monitoring (SHM) system were used during the bridge testing phase. A novel symmetry index is introduced using statistical analyses of deflection and strain measurements. Frequency Domain Decomposition (FDD) is implemented to the strain measurements to estimate the bridge mode shapes and damping ratios. Furthermore, Markov Chain Monte Carlo (MCMC) is also implemented to examine the reliability of bridge performance while ambient design trucks are in static or moving at different speeds. Strain, displacement and acceleration were measured at selected locations on the bridge. The results show that the symmetry index can be an efficient and useful measure in assessing the steel bridge performance. The results from the used method reveal that the performance of the Sungsu bridge is safe under operational conditions.

A Comparative Study on Elastic-Plastic-Static Analysis of Sheet Metal Forming (탄소성 정적해석시 해에 미치는 여러인자들의 비교연구)

  • 박종진
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1999.03b
    • /
    • pp.241-244
    • /
    • 1999
  • A series of parametric study was performed for the investigation of the influence of several analysis parameters to the solution behavior in the elasti-plastic-static analysis of sheet metal forming. The parameters taken into the consideration in the present study are finite element mesh distribution and numerical integration scheme, The elstic-plastic-static analysis was performed for two cases : deflection by a point force bending by a punch Results obtained with different selections of the parameters were compared with each other experimental measurements and analytical solutions.

  • PDF

A modified Zienkiewicz-Zhu error estimator

  • Stephen, D.B.;Steven, G.P.
    • Structural Engineering and Mechanics
    • /
    • v.4 no.1
    • /
    • pp.1-8
    • /
    • 1996
  • A new error measure for a static finite element analysis is proposed. This error measure is a modification to the Zienkiewicz and Zhu energy norm. The new error estimator is a global error measure for the analysis and is independent of finite element model size and internal stresses, hence it is readily transportable to other error calculations. It is shown in this paper the the new error estimator also produces conservative error measurements, making it a suitable procedure to adopt in commerical packages.

Reliability and Validity Study of Inertial Sensor-Based Application for Static Balance Measurement

  • Park, Young Jae;Jang, Ho Young;Kim, Kwon Hoi;Hwang, Dong Ki;Lee, Suk Min
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.3
    • /
    • pp.311-320
    • /
    • 2022
  • Objective: To investigate the reliability and validity of static balance measurements using an acceleration sensor and a gyroscope sensor in smart phone inertial sensors. Design: Equivalent control group pretest-posttest. Methods: Subjects were forty five healthy adults aged twenty to fifty-years-old who had no disease that could affect the experiment. After pre-test, all participants wore a waist band with smart phone, and conducted six static balance measurements on the force plate twice for 35 seconds each. To investigate the test-retest reliability of both smart phone inertial sensors, we compared the intra-correlation coefficient (ICC 3, 1) between primary and secondary measurements with the calculated root mean scale-total data. To determine the validity of the two sensors, it was measured simultaneously with force plate, and the comparision was done by Pearson's correlation. Results: The test-retest reliability showed excellent correlation for acceleration sensor, and it also showed excellent to good correlation for gyroscope sensor(p<0.05). The concurrent validity of smartphone inertial sensors showed a mostly poor to fair correlation for tandem-stance and one-leg-stance (p<0.05) and unacceptable correlation for the other postures (p>0.05). The gyroscope sensor showed a fair correlation for most of the RMS-Total data, and the other data also showed poor to fair correlation (p<0.05). Conclusions: The result indicates that both acceleration sensor and gyroscope sensor has good reliability, and that compared to force plate, acceleration sensor has unacceptable or poor correlation, and gyroscope sensor has mostly fair correlation.

Effect of Motor Imagery Training with Visual and Kinesthetic Imagery Training on Balance Ability in Post Stroke Hemiparesis (시각적인 상상연습 훈련과 운동 감각적인 상상연습 훈련이 편마비 환자의 균형능력에 미치는 영향)

  • Kim, Jin-Seop;Kim, Kyoung
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.5 no.4
    • /
    • pp.517-525
    • /
    • 2010
  • Purpose : This study aimed to compare the effect of two conditions (visual and kinesthetic) of motor imagery training on static and dynamic balance. Methods : Fifteen patients with post-stroke hemiparesis volunteered to participate in this study. Two motor imagery training conditions, for 10minute trials, employed with audiotape instructions. Measurements were performed at pretest, posttest and 1-hour follow up in both static and dynamic balance. Results : Measures were significantly different both static and dynamic balance tests between treatment conditions (kinesthetic imagery more than visual imagery) at the pretest, post test, and 1-hour follow-up (p<.05). Measures of both static and dynamic balance tests, for both conditions, improved significantly from pretest to posttest (p<.05), and was maintained at 1-hour follow up. Conclusion : This study showed that both imagery training applications were effective treatment strategies for both static and dynamic balance. When comparing the two treatment conditions, kinesthetic motor imagery training was more effective than the visual motor imagery training in static and dynamic balance.

Laboratory Validation of Bridge Finite Model Updating Approach By Static Load Input/Deflection Output Measurements (정적하중입력/변위출력관계를 이용한 단경간 교량의 유한요소모델개선기법: 실내실험검증)

  • Kim, Sehoon;Koo, Ki Young;Lee, Jong-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.3
    • /
    • pp.10-17
    • /
    • 2016
  • This paper presents a laboratory validation of a new approach for Finite Element Model Updating(FEMU) on short-span bridges by combining ambient vibration measurements with static load input-deflection output measurements. The conventional FEMU approach based on modal parameters requires the assumption on the system mass matrix for the eigen-value analysis. The proposed approach doesn't require the assumption and even provides a way to update the mass matrix. The proposed approach consists of two steps: 1) updating the stiffness matrix using the static input-deflection output measurements, and 2) updating the mass matrix using a few lower natural frequencies. For a validation of the proposed approach, Young's modulus of the laboratory model was updated by the proposed approach and compared with the value obtained from strain-stress tests in a Universal Testing Machine. Result of the conventional FEMU was also compared with the result of the proposed approach. It was found that proposed approach successfully estimated the Young's modulus and the mass density reasonably while the conventional FEMU showed a large error when used with higher-modes. In addition, the FE modeling error was discussed.

Measurements of Elastic Moduli of Rock Cores Using Free-Free Resonance Tests (자유단 공진시험을 이용한 암석의 탄성계수 측정)

  • 목영진
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.353-360
    • /
    • 1998
  • Dynamic measurements are used rather sparingly to determine the elastic moduli of rock cores and modulus values are not much utilized in design practice. The reason seems to result from the general perception that values obtained by dynamic measurement are much higher (about 10 times) than those determined statically. This paper presents results from dynamic and static tests on rock cores. The findings are : 1) elastic moduli can be consistently determined by laboratory seismic testing. 2) nonlear deformation characteristic of rock cores was tentatively proposed with variation in elastic modulus with strain.

  • PDF

Identification of Geotechnical Paramters Using Relative Convergence Measurements (상대변위를 이용한 지반정수 인식)

  • Choi, Sang-Hyun;Cho, Kook-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.418-423
    • /
    • 2005
  • In designing underground structure such as tunnels, estimating geotechnical characteristics of the ground is one of the most important and difficult tasks. In this paper, a methodology that can identify geotechnical parameters using only field-measured relative convergence displacements is presented. By using only relative convergence measurement data, inevitable errors in absolute convergence estimation can be avoided and in turn the parameter estimation process can be simplified. The methodology utilizes sensitivity relationship between static displacement measurements and geotechnical parameters. The feasibility and applicability of the proposed methodology is verified via a 3-d numerical example of a tunnel structure.

  • PDF

Reliability of static balance abilities measure using a smartphone's acceleration sensor (스마트폰의 가속도 센서를 이용한 정적균형능력 측정의 신뢰도 연구)

  • Han, Seul-Ki;Lee, In-Hak;Park, Nu-Ri
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.6
    • /
    • pp.233-238
    • /
    • 2016
  • The purpose of this study is to investigate the reliability of static balance measurements using a smartphone. Thirty subjects were selected among university students who had no fractures, history of operation, or inflammatory arthritis, and they had not started regular exercise during the past three months. The smartphone used in this study was a Galaxy S5LTE (SM-G900F, Samsung, Korea, 2014), and the application was a Sensor Kinetics Pro (Ver. 2.1.2, INNOVENTIONS Inc., US, 2015). Static balance ability was measured three times at one-day intervals between tests and retests. The first and second measurements used the same process. Analysis was done using the Wilcoxon signed rank test and intraclass correlation coefficient (ICC (2,1)). The results were as follows. With eyes opened, there was no significant difference (p>0.05), a high volume of correlation (r>0.75, p<0.05), and very high reliability (ICC>0.80) between the first measurement and second measurement. With eyes closed, there was also no significant difference (p>0.05), a high volume of correlation (r>0.75, p<0.05), and very high reliability (ICC>0.80) between the measurements. The results show that the smartphone is likely accurate for measuring static balance. This study will look forward to being the only basis for measuring future application development and the ability to balance.