• Title/Summary/Keyword: static and dynamic stability analysis method

Search Result 105, Processing Time 0.025 seconds

Calculation of Active Power Transfer Capability using Repeated Power Flow Program

  • Ham, Jung-Pil;Kim, Jung-Hoon;Lee, Byung-Ha;Won, Jong-Ryul
    • KIEE International Transactions on Power Engineering
    • /
    • v.12A no.1
    • /
    • pp.15-19
    • /
    • 2002
  • The power transfer capability is determined by the thermal, dynamic stability and voltage limits of the generation and transmission systems. The voltage stability depends on the reactive power limit and it affects the power transfer capability to a great extent. Then, in most load flow analysis, the reactive power limit is assumed as fixed, relatively different from the actual case. This paper proposes a method for determining the power transfer capability from a static voltage stability point of view using the IPLAN which is a high level language used with PSS/E program. The f-V curve for determining the power transfer capability is determined using Repeated Power Flow method. It Is assumed that the loads are constant and the generation powers change according to the merit order. The maximum reactive power limits are considered as varying similarly with the actual case and the effects of the varied maximum reactive power limits to the maximum power transfer capability are analyzed using a 5-bus power system and a 19-bus practical power system.

Concrete Caisson Manufacturing and Transferring Apparatus and Method (II) (초대형 콘크리트 케이슨 다단계 일괄 제작 및 운반공법 개발 (II))

  • Zung, Zi-Man;Lee, Won-Pyo;Park, Jung-Min
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.400-403
    • /
    • 2004
  • In conventional methods, the availability of floating crane has determined the size of a concrete caisson. However, this paper introduces a new method for larger caisson production that make it possible to complete caisson fabrication and launch out without use of floating crane. The new method carries out multi-step fabrication of caisson and horizontal transfer of caisson on a single casting bed which consists of collapsible soffit form, trough, aero go watercaster system or low frictional PTFE added jacking system, half-submergible floating dock. To make the new method successfully launched, the static and dynamic analysis is carried out to obtain the stability of caisson launching and experimental research is conducted in evaluating friction occurred between PTFE pad and steel track. Lastly, the comparison of the new method and the conventional method are detailed. With significant benefits in construction costs reduction and construction time reduction, this new method in this paper would be recommended for extensive application in large port and harbor construction projects.

  • PDF

A study on Voltage Stability Analysis by the Lyapunov Direct Method in 2-bus Systems (Lyapunov 직접법에 의한 2모선 개통의 전압안정도 해석)

  • Moon, Young-Hyun;Lee, Tae-Shik;Kim, Baik;Lee, Eung-Hyuk;Park, Neung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1993.07a
    • /
    • pp.106-108
    • /
    • 1993
  • This paper gives derivations of voltage collapse conditions by using the Lyapunov function, which yields the exactly same results with the sensitivity analysis approach. On the other hand, the voltage collapse phenomenon is interpreted in the physical sense, and causes of the static voltage unstability and the dynamic voltage unstability are analyzed with the use of proposed Lyapunov function. In addition a new method is developed to calculate the power capacity limit of transmission lines with respect to voltage stability. This paper shows that it is able to analyze the voltage collapse with the Lyapunov direct method in the simple 2-bus system and proposes that the method works well by observing the variation of Lyapunov function as the load is increased in the system.

  • PDF

Dynamic Analysis of MABB(Multiple Arches Bowstring Bridge) and Single Arch Subjected to Moving Loads (이동하중을 받는 다중아치와 일반아치의 동적거동 분석)

  • Yhim, Sung Soon;Kim, Dong Yong;Son, Suk Ho;Kong, Min Sik
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.5 s.78
    • /
    • pp.537-547
    • /
    • 2005
  • MABB(Editor's note: Please spell out "MABB" upon first mention)is a new structural type of arch that connects arch ribs and stiffened girders with two internal arches. In this study, the static and dynamic behavior of MABB were analyzed in comparison with those of conventional arches for the investigation of the structural effect of MABB on moving loads. For the purpose of surveying the effect of internal arches on the dynamic behavior of structure, natural frequency and natural vibration mode were investigated and the static and dynamic behavior were analyzed by the method of idealizing train loads as traveling loads consisting of a group of concentrated loads. From the results, the following conclusions were known. First, it is concluded that with MABB, decreasing the section of stiffened girders is possible as compared with conventional arches because the increase of stiffness by internal arches is larger than that of the mass of internal arches. Second, MABB has the advantage of assurance of stability of dynamic behavior because the dynamic behavior of MABB on moving loads is usually investigated in a more stable way than that of conventional arches.

Study on the Oil-free Turbocharger Supported by Air Foil Bearing (공기 포일 베어링으로 지지되는 무급유 터보 과급기 회전체 설계에 대한 연구)

  • Lee, Yong-Bok;Kim, Tae-Ho;Kim, Chang-Ho;Lee, Nam-Soo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.453-458
    • /
    • 2002
  • The feasibility study on supporting a turbocharger rotor on air foil bearing is investigated. Based on finite difference method and Newton-Raphson method, the static equilibrium position of a turbocharger rotor is predicted. And using finite difference method and perturbation method, dynamic characteristics of air foil bearings are calculated. Rotordynamic analysis is performed by finite element method, with collaboration of calculated stiffness and damping of foil bearing. The effect of compliance and clearance of bump foil bearing on the oil-free turbocharger is investigated in terms of rotordynamics. And the critical speeds, eccentricity ratio, vibration amplitude, and stability are considered. It is demonstrated that foil bearings offer a rlausible replacement for oil-lubricated bearings in turbocharger.

  • PDF

Dynamic State Feedback Controller Synthesis for Fuzzy Models (퍼지 모델을 위한 동적 상태 피드백 제어기 설계)

  • Chang, Wook;Joo, Young-Hoon;Park, Jin-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1999.07b
    • /
    • pp.528-530
    • /
    • 1999
  • This paper addresses the analysis and design of fuzzy control systems for a class of complex single input single output nonlinear systems. Firstly, the nonlinear system is represented by well-known Takagai-Sugeno (TS) fuzzy model and the global controller is constructed by compensating each linear model in the rule of TS fuzzy model. The design of conventional TS fuzzy-model-based controller usually is composed of two processes. One is to determine static state feedback gain of each local model and the other is to validate the stability of the designed fuzzy controller. In this paper, we propose an alternative of the design of TS fuzzy-model-based controller. The design scheme is based on the extension of conventional optimal control theory to the design of TS fuzzy-model-based controller. By using the proposed method the design and stability analysis of the TS fuzzy model-based controller is reduced to the problem of finding the solution of a set of algebraic Riccati equations. And we use the recently developed interior point method to find the solution of AREs, where AREs are recast as the LMI formulation. One simulation example is given to show the effectiveness and feasibility of the proposed fuzzy controller design method.

  • PDF

Aerodynamic Damping Analysis of a Vane-type Multi-Function Air Data Probe

  • Lee, Yung-Gyo;Park, Young-Min
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.14 no.1
    • /
    • pp.99-104
    • /
    • 2013
  • Configuration design, analysis, and wind tunnel test of a vane-type multi-function air data probe (MFP) was described. First, numerical analysis was conducted for the initial configuration of the MFP in order to investigate aerodynamic characteristics. Then, the design was modified to improve static and dynamic stability for better response characteristics. The modified configuration design was verified through wind tunnel tests. The test results are also used to verify the accuracy of the analytical method. The analytically estimated aerodynamic damping provided by the Navier-Stokes equation solver correlated well with the wind tunnel test results. According to the calculation, the damping coefficient estimated from ramp motion analysis yielded a better correlation with the wind tunnel test than pitch oscillation analysis.

The Analysis of a High Frequency Series Resonant DC-DC Converter (고주파 직렬공진형 DC-DC Converter의 특성 해석)

  • 이윤종;김철진
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.9
    • /
    • pp.934-943
    • /
    • 1990
  • There are no turn-on losses in the series Resonant Converter which operates above the resonance frequency, and the commutation stress on the switched component is low. For a given Series Resonant Converter with specified load resistance, the output voltage is a function of the operation frequency. This paper describes the static and dynamic characteristic analysis of the Series Resonant DC to DC Converter, which is operating above the resonant frequency, with frequency control. For the analysis method, state plane technique is adopted, and the circuit operation is defined from normalized switching frequency, Fsn. Under this condition, circuit performance is analyzed ideally. The validity of the proposed analysis is verified by comparing with experimental results, the stability of the converter is confirmed against small variations around the operating point by conventional frequency domain analysis, and the stress quantity added to switch component is shown.

  • PDF

A Study on the Oil-free Turbocharger Supported by Air Foil Bearing (공기 포일 베어링으로 지지되는 무급유 터보 과급기 회전체 설계에 대한 연구)

  • Lee Yong-Bok;Kim Tae-Ho;Kim Chang-Ho;Sa Jong-Sung;Lee Nam-Soo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.1 s.18
    • /
    • pp.51-56
    • /
    • 2003
  • The feasibility study on the oil-free turbocharger supported by air foil bearings is investigated. Using the perturbation method, dynamic characteristics of air foil bearings are calculated based on the static equilibrium position of a turbocharger rotor is predicted. With collaboration of calculated stiffness and damping of foil bearing, rotordynamic analysis is performed using the finite element method. The effects of bump compliance and bearing clearance on rotordynamic characteristics of the oil-free turbocharger such as the critical speeds, eccentricity ratio, vibration amplitude and stability are investigated.

Development of a 3D FDEM-Based Static-Dynamic Sequential Damage Analysis Method for Optimal Mechanical Demolition Processes for Large-Scale Aging Structures (대형 노후 구조물의 최적 기계식 해체 공정을 위한 3D FDEM 기반 정적-동적 손상 순차 해석 기법 개발)

  • Gyeong-Gyu Kim;Chan-Hwi Shin;Gyeong-Jo Min;Daisuke Fukuda;Kyong-Pil Jang;Tae-Hyeob Song;Sang-Ho Cho
    • Explosives and Blasting
    • /
    • v.42 no.3
    • /
    • pp.9-22
    • /
    • 2024
  • As buildings constructed in the 1980s during a period of rapid urbanization and economic growth have aged, the demand for demolition, especially of reinforced concrete structures, has increased. In large-scale structures such as industrial buildings, a mixed approach utilizing both mechanical demolition and explosive demolition methods is being employed. As the demand for demolition rises, so do safety concerns, making structural stability during demolition a crucial issue. In this study, drones and LiDAR were used to collect actual structural data, which was then used to build a simulation model. The analysis method employed was a combination of the Finite Element Method (FEM) and the Discrete Element Method (DEM), known as the Combined Finite-Discrete Element Method (FDEM), which was used to perform dynamic structural analysis during various demolition phases. The results were compared and analyzed with the commercial software ELS to assess its applicability.