• Title/Summary/Keyword: state variable

Search Result 1,630, Processing Time 0.044 seconds

A Study on the Global Management Strategy for Product Quality Assurance Based on Brand Power and Country of Origin Effect (글로벌 품질보증 경영 전략에 관한 연구: 브랜드 명성 및 제조 국가 이미지를 중심으로)

  • Hwang, Hee-Joong
    • Journal of Distribution Science
    • /
    • v.11 no.2
    • /
    • pp.23-33
    • /
    • 2013
  • Purpose - Numerous studies have tried to assess the role of a warranty as an explanatory instrument for product quality. While one study argued that manufacturers signal their superior quality to consumers by extending the duration of a warranty, quality is not necessarily related to warranty and a warranty for a short duration is a sign of high product quality. However, there are limitations to measuring product quality in terms of a single variable such as a warranty. Some other studies have evaluated the influence of brand power or value and price on the supposed quality of a product while the influence of warranty was found to be insignificant. Research design, data, methodology - The study analyzes the influence of brand power and the country of origin effect on consumers' perception of product quality in line with warranty and establishes a priority strategy. Especially, consumer experience has a significant influence on state of the art technology products like applied home electronics as these goods are generally quite expensive and consumers expend significant energy in purchasing them, so the associated warranty and brand can have a critical role in the decision making process. The price of the product was excluded in this discussion as it continually varies with the market share of the product. Results - The results of the analysis are as follows: First, each of the factors such as the standard of the warranty, brand power, and country of origin effect influences the degree of satisfaction of an individual. Second, the factors brand power and quality of the warranty interact both complementarily and synergistically at a time, depending on the brand power. As brand power is more significant, the degree of satisfaction is greater in case of products with low quality warranty compared to those with high quality warranty. Third, the brand power and country of origin effect present a complementary interaction. Fourth, the country of origin effect and quality of a warranty interact synergistically. Conclusions - Thus, the higher the quality of warranty, greater is the increment in the degree of satisfaction. The comprehensive study on the effect of the country of origin on the purchase decision process and the degree of satisfaction compared to the other elements shows that in case of Japanese and Korean markets the brand power of a company is desirable in sustaining the quality of warranty to the industrial average. Also, there is no significant improvement in the perceived quality of the product when the quality of the warranty is lowered. Therefore, the warranty effect diminishes when the value of the brand is known, while it perishes when both the brand power and the country of origin effect are strong enough.

  • PDF

Estimation of Acidic Wastewater Toxicity on the Activated Sludge (활성슬러지에 미치는 산폐수의 독성도 예측)

  • Choi, Kwang-Soo;Ko, Joo-Hyung;Jang, Won-Ho;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.12
    • /
    • pp.2175-2185
    • /
    • 2000
  • Respiration rate should be a reasonable state variable for the activated sludge and could be used to simulate the performance of the activated sludge process. Toxic materials are classified into three groups, competitive, noncompetitive and uncompetitive. They increase/decrease the half saturation coefficient or specific growth rate. that means decreasing of the substrate removal capacity. In this research, a pilot-scale activated sludge process was operated under extended aeration method, and a representative noncompetitive inhibitor, acidic wastewater was applied to establish a respirometry-based toxicity model. Using this model. the correlation coefficient between measured and calculated respiration rate was 0.96 when acidic wastewater(pH 3.9~5.5) was introduced continuously to the aeration tank. Even though respiration rate was decreased by toxic effect of acidic wastewater, effluent substrate concentration represented to COD was deteriorated just a little bit. It might be caused by the low ratio of readily biodegradable substrate in the input substrate. Reduction of respiration rate by decreasing of input substrate concentration was much lower than that by acidic wastewater, and hence it was estimated that the possibility of false toxic alarm caused by decreasing of substrate concentration should be low.

  • PDF

Development of Analysis Model and Improvement of Evaluation Method of LOS for Freeway Merging Areas (고속도로 합류부 분석모형 개발 및 서비스수준 평가 기법 개선 연구)

  • Lee, Seung-Jun;Park, Jae-Beom
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.7 s.93
    • /
    • pp.115-128
    • /
    • 2006
  • The analytic methodology of a merging area in KHCM(2004) supposes that congestion nay occur when traffic demand is more than capacity However, in many cases, congestion on merging area occurs when summation of traffic demand of main line and ramp is less than capacity, and in present methodology analysis of how main line and ramp flow effect on congestion occurrence is difficult. In this study, the model that is able to estimate traffic flow condition on merging area in accordance with the combination of main line and ramp demand flow is developed. Main characteristic of the model is estimation of maximum possible throughput rate and maximum throughput rate according to the combination of main line and ramp demand flow. Through the estimation of maximum possible throughput rate and maximum throughput rate. it was Possible to predict whether congestion would occur or not and how much maximum throughput rate and congestion would be on merging area. On one hand, in present LOS evaluation methodology on merging area, congestion state is determined as un-congested flow if demand flow is less than capacity. Therefore, to establish more reasonable In evaluation method, new criterion of LOS evaluation on merging area was searched based on the model of this study.

STUDY OF PATENCY RATE IN VARIABLE MICROVASCULAR ANASTOMOSIS (다양한 방법으로 적용한 미세혈관문합술간의 개존율연구)

  • Kim, Uk-Kyu;Kim, Yong-Deok;Byun, June-Ho;Shin, Sang-Hun;Chung, In-Kyo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.5
    • /
    • pp.349-357
    • /
    • 2003
  • Several microvascular anastomotic techniques have been described with methodical effectiveness, patency rates, healing state of microscopic findings. This experimental study presents the comparison of three types of arterial microvascular anastomotic techniques: end-to-end(ETE) anastomosis, end-in-end(EIE) anastomosis, and continuous technique. Sixty male Sprague-Dawley rats, 60 femoral arteries were used for this study. Twenty rats per each technique were used and sacrificed at post-operation 1 day, 3 days, a week, 2 weeks for scanning electromicroscopic findings. The patency was monitored by miniDoppler throughout total experimental periods. The anastomotic time on each method was measured to compare the technical effectiveness. The final results were as follows: 1. The anastomotic time for the end-in-end technique was significantly shorter than another techniques. The average time for each technique was measured as 15 minutes on EIE technique, 20 minutes on continuous technique and 25 minutes on ETE technique. 2. The patency rate for the end-in-end technique at 2 weeks also was superior to another techniques. The patency rate for each technique was demonstrated as 90 % on EIE technique, 85 % on ETE technique and 80 % on continuous technique. 3. The scanning electromicroscopic findings on healing condition of vessel endothelium during the observation period showed that the end results of EIE technique, ETE technique and continuous technique in sequence were good. The end-in-end technique proved to be the superior with regard to anastomotic time and patency rate when compared to end-to-end technuqe, so EIE techniqe might be well available for the case of large discrepancy of vessel size. The patency rate, microscopic healing findings in continuous technique were seen as the lowest level among the three anastomotic techniques, therefore the application of continuous technique was recommended only on the inevitable case.

Estimation of VMS Traffic Information Value Using Contingent Valuation Method (조건부 가치측정법을 활용한 VMS 교통정보 가치 추정)

  • Choi, Jung Yoon;Yu, Jeong Whon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.3
    • /
    • pp.42-52
    • /
    • 2013
  • In this study, value of VMS (Variable Message Sign) traffic information is estimated by using CVM (Contingent Valuation Method), which is developed to quantify the value of non-marketable goods in environmental economics. CVM is used to estimate the value of goods provided by a project under consideration and then the project feasibility can be indirectly examined on the basis of the estimated value. This study focuses on estimating to estimate value of traffic information provided through VMS, a part of the transportation system enhancement project by Korea Expressway Corporation which is aimed at mitigating traffic problems on expressways. In particular, this study analyzes value of information separately by trip purpose, information type, and traffic flow condition. A state preference survey was designed to estimate the value of non-marketable traffic information. To maximize reliability of the survey results, a pilot survey was taken before the main survey. The open-ended question method was adopted in capturing users' willingness-to-pay. Both Tobit and binary Probit models were applied in estimating the value of VMS traffic information and their parameters were estimated using the maximum likelihood estimation. The estimation results suggests that the value of traffic information perceived by users is 518.28 KRW.

The Experimental Study on the Bond behavior of High strength concrete (고강도 콘크리트의 부착거동에 관한 실험적 연구)

  • Lee, Joon-Gu;Kim, Woo;Park, Kwang-Su;Kim, Dae-Joung;Lee, Wong-Chan;Kim, Han-Joung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.774-780
    • /
    • 1999
  • The study of bond behavior between concrete and rebar has been performed for a long time. On this study, we tried to analysed variation of bond behaviors quantitatively with varying the strength of concrete. Bond stress which observed below the neutral surface of beam and at connecting part of beam and column is affected by various bond parameters. Resistance of deformed bars which embedded in concrete to the pullout force is divided 1) chemical adhesive force 2) frictional force 3) mechanical resistance of ribs to the concrete and these horizontal components of resistance is being bond strength. We selected the most common and typical variable which is concrete strength among various variables. So we used two kinds of concrete strength like as 25MPa(NSC) and 65MPa(HSC). Tension Test was performed to verify how bond behavior varied with two kinds of concrete strength. Concentration of bond stress was observed at load-end commonly in Tension Test of the initial load stage. At this stage stress distribution was almost coincident at each strength. As tension load added, this stress distribution had difference gradually and movement of pick point of bond stress to free-end and central section was observed. This tendency was observed at first and moving speed was more fast in NSC. At the preceeding result the reason of this phenomenon is considered to discretion of chemical adhesion and local failure of concrete around rebar in load-end direction. Especially, when concrete strength was increased 2.6 times in tension test, ultimate bond strength was increased 1.45 times. In most recent used building codes, bond strength is proportioned to sqare root of concrete compressive strength but comparison of normalized ultimate bond strength was considered that the higher concrete strength is, the lower safety factor of bond strength is in each strength if we use existing building codes. In Tension Test, in case of initial tensile force state, steel tensile stress of central cross section is not different greatly at each strength but tensile force increasing, that of central cross section in NSC was increased remarkably. Namely, tensile force which was shared in concrete in HSC was far greater than that of concrete in NSC at central section.

  • PDF

Institutional Approach to Innovation: the Knowledge Spillovers in Regional Innovation System and Innovative Cluster - Review and New Issue of Antecedent Research - (혁신의 제도적 접근: 지역혁신체제와 혁신클러스터의 지식파급효과 -선행연구의 검토와 새로운 쟁점-)

  • Bae, Eong Hwan
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.115-135
    • /
    • 2015
  • In the glocalization a common phenomenon of several nations reveals knowledge innovation and growth by the important subject of region and state and is studied at theory and practice. the successful cases of regional development in an advanced country have leading innovation through regional innovation system and cluster. therefore we are necessary to analyse how the knowledge spillovers in innovative cluster as the reduced model of regional innovation system guide firm innovation and region growth. this article reviews theories and empirical studies of the knowledge spillovers in the regional innovation system and innovative cluster of innovative geography and proposes a new research issues for further explorations of the knowledge spillovers. Previous studies assist that knowledge spillovers exist in knowledge-based industries of specific local area and local innovation accomplishes through pure knowledge spillover. but limits of these studies include narrow region and technological area, few analytical variable and exclusion of rent knowledge spillover. therefore new research topics related with that exemplifies geographical dimension(concentration and decentralization), technological dimension(knowledge based industry), category of analytic variables(previous indicators, time, and social capital), conceptualization(appropriation means, markets for technology) etc.

  • PDF

Related Factors with Medication Task Ability in Rural Elderly (일부 농촌 노인에서의 약물복용 수행능력과 관련된 요인)

  • Lee, Moo-Sik
    • Journal of agricultural medicine and community health
    • /
    • v.24 no.1
    • /
    • pp.35-47
    • /
    • 1999
  • Medication non-compliance among the elderly results in medical problems and substantial cost to the health care system. This study investigate predicted variable related to the medication task ability among elderly. This study was done in the selected 4 villages in Kimchun County of Kyungbuk Province from July to August, 1996. The subject was the resident that 202 adults above 60 years of age. The questionnaire of interview included medication task ability, socio-demographic data, COOP/WONCA chart, family ABGAR score. BDI(Beck depression inventory), ADL(activities of daily living), IADL(instrumental activities of daily living), and MMSE-K(minimental state examination-Korean version). The results were as followed : 1. Approximately 49% of study population was taking drug medication currently. We found that 93% of study population was successful at the medication task all alone, 6% was failure at the medication task all alone, so need help partly or completely. 2. Significant variables between group of medication task ability were age, educational attainment, IADL, and MMSE-K in univariate analysis. And significant correlated variables with medication task ability were ADL, IADL, MMSE-K, and BDI in correlation analysis. 3. Major predictors to medication task ability on multiple logistic regression were IADL and sex finally. Findings suggest that IADL is related to medication task ability than other test battery of health status, so IADL could be used to necessary for medication management and add information to conventional methods of assessing mental status.

  • PDF

Effects of Water Temperature Changes on the Oxygen Consumption Rhythm in the Japanese eel, Anguilla japonica

  • Kim, Jong-Wook;Lee, Tae-Won;Noh, Il;Kim, Wan-Soo
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.943-951
    • /
    • 2011
  • We investigated the effects of temperature changes on the oxygen consumption rhythm in Japanese eels, Anguilla japonica, using an automatic intermittent flow respirometer (AIFR). The endogenous rhythm of the oxygen consumption rate (OCR) in the eels (n = 18; 44-74 cm, 145-690 g), freshly collected by bag net from estuaries, was nearly synchronous with the tidal pattern of the estuarine collection site. The magnitude of mean OCR (mOCR) of eels showed variable range of 82.2 - 116.5 ml $O_2\;kg^{-1}ww \;h^{-1}$ under constant conditions. In case of increasing temperature from 25 to $38^{\circ}C$, the OCR of eels exhibited a gradually increasing trend with a rhythmic pattern until $36^{\circ}C$. Above $36^{\circ}C$ the rhythms of the OCR dampened and the OCR decreased rapidly at around $36-37^{\circ}C$. The OCR of the eels exhibited the maximum value at $38^{\circ}C$, and then it sharply decreased. The results suggested that the critical thermal maximum (CTM) regarding the endogenous rhythms of the eels was at around $36-37^{\circ}C$ when water temperature increased at $0.5^{\circ}C$/14 h following the acclimation at $25^{\circ}C$. In case of decreasing temperature ($0.5^{\circ}C$/14 h) from 25 to $0^{\circ}C$, the OCR of the eels displayed a abrupt decrease up to $23^{\circ}C$, and between at 23 and $20^{\circ}C$, there was an agitation which showed a slight increase in the OCR with a duration of 1-2 days. Below $9^{\circ}C$, the OCR rhythm of the eels showed a constant state regardless of temperature decreasing. These results suggest that the Japanese eel has an upper incipient lethal temperature at $36^{\circ}C$, with a lower thermal limit at $9^{\circ}C$. The biochemical aspects of the eels influenced by water temperature need to be further studied.

A Study on the Geometric Design Parameters for Optimization of Cooling Device in the Magnetocardiogram System (심자도 장비의 냉각장치 특성 최적화를 위한 기하 설계 변수 연구)

  • Lee, Jung-Hee;Lee, Young-Shin;Lee, Yong-Ho;Lim, Hyun-Kyoon;Lee, Sung-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.2
    • /
    • pp.153-160
    • /
    • 2010
  • A magnetocardiogram (MCG) is a recording of the biomagnetic signals generated by cardiac electrical activity. Biomagnetic instruments are based on superconducting quantum interference devices (SQUIDs). A liquid cryogenic Dewar flask was used to maintain the superconductors in a superconducting state at a very low temperature (4 K). In this study, the temperature distribution characteristics of the liquid helium in the Dewar flask was investigated. The Dewar flask used in this study has a 30 L liquid helium capacity with a hold time of 5 d. The Dewar flask has two thermal shields rated at 150 and 40 K. The temperatures measured at the end of the thermal shield and calculated from the computer model were compared. This study attempted to minimize the heat transfer rate of the cryogenic Dewar flask using an optimization method about the geometric variable to find the characteristics for the design geometric variables in terms of the stress distribution of the Dewar flask. For thermal and optimization analysis of the structure, the finite element method code ANSYS 10 was used. The computer model used for the cryogenic Dewar flask was useful to predict the temperature distribution for the area less affected by the thermal radiation.