The Analysis of Actual Condition and Technical Standards for Electrical Facilities in Amusement Electric Trains in Amusement Parks (유원시설 내 유희용전차의 설치규정 및 국내 적용실태 분석)

  • Kim, Han-Sang;Bae, Suk-Myong;Bang, Sun-Bae;Lee, Gyun-Ho;Kim, Gi-Hyun;Kim, Chong-Min
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.6
    • /
    • pp.100-107
    • /
    • 2004
  • Amusement electric train which is a kind of fun rides in amusement parks is prescribed by the provision of article 252 of the technical standards of the MOCIE(Ministry of Commerce, Industry and Energy) notification. The technical standards which is prescribed on the basis of Japanese technical standards is minimum compulsory standards in Korea. But these early standards can not be correctly applied for current condition of well-developed technical environment In order to improve the early standards, this paper will suggest a reform plan of the current technical standards by means of analyzing actual applied conditions and examining 28 amusement electric trains in Korea

A Study on the Legal Standards and Design Guidelines on Disabled Auditorium in Cultural Facilities (문화시설 내 장애인 관람석에 대한 법적기준 및 문헌 연구)

  • Lee, Kijeong;Yoon, Taejun;Park, Hyeonsoo
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.4
    • /
    • pp.37-47
    • /
    • 2015
  • Purpose: Due to increase of interest in the viewing environment for the disabled, ordinances that are related to an optimal auditorium for the disabled are being executed. However, since there are no detailed criteria regarding the optimal auditorium, there is a necessity that it should be supported by more concrete criteria for installation. Therefore, the study is aimed to be utilized as basic data to suggest the criteria for installation of the optimal auditorium in the future through domestic and international legal standards and the analysis of design guidelines that are related to the auditorium for the disabled. Methods: First, legal standards and design guidelines that are related to the auditorium for the disabled were analyzed, and Second, items and things to be improved that are required to suggest the criteria for installation of the optimal auditorium in the future were looked into by comparing and analyzing each contents. Results: Items and considerations by items that are required to establish the criteria for installation of the optimal auditorium were looked into, and based on these results, concrete and standardized installation criteria can be suggested. Implications: Based on the analysis results, the optimal viewing environment for the disabled within cultural facilities can be created through establishment of more concrete installation criteria for the optimal auditorium in the future.

A An Experimental Study for Load Capacity and Dip Characteristic in Overhead Transmission Lines (가공송전선의 부하용량과 이도 특성에 관한 실험적 연구)

  • Kim, Sung-Duck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.177-183
    • /
    • 2010
  • Overhead transmission lines in domestic area have been built by several different design standards of dip and ground clearance. This paper describes an experimental study for evaluating load capacity and dip margin in overhead transmission lines. Such design standards for selection of overhead transmission conductors, dip and ground clearance, as well as electrical equipment technical standard are discussed. Based on daily load and weather data, several characteristics such as line utilization factor, load factor, conductor temperature and dip, etc. are analyzed, and compared with the specified levels of design standards. As a result, it is verified that DLR method can be a clue of the solving of the problem, for occurring in old transmission conductors which may be rarely operating below standards.

Fault Current Calculation and Coordination by IEC Standards (IEC 표준에 의한 고장전류 계산과 보호협조)

  • Son, Seok-Geum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.12
    • /
    • pp.6-12
    • /
    • 2014
  • The safety and reliability of the power system short-circuit current, the short-circuit current depends on the failure to obtain the objective is to quickly eliminate the breaking capacity of the circuit-breaker selection of the cable, the insulation of electrical equipment and protective relay an important factor in determining the level correction and protective relay selection scheme to be meaningful. Standards used in the domestic circuit breaker is applied to the production of IEC standard, but the American National Standards (ANSI / IEEE) by NEMA specification of the fault current calculations and the application of the asymmetric coefficient Korea. Therefore, in this paper, the IEC 60909 standard IEC breaker fault current calculation method and the method for selection of system configurations reviewed and protection system for reviewing the configuration of various protective relays appropriate correction and the correction value is main protection, back-up protection the equipment so that the period of protection relay coordination to minimize accidents and accident protection to minimize interruptions proposed for cooperation.

Comprehensive Countermeasure for Safety of School Electric Installation (학교 전기설비의 안전을 위한 방안)

  • Jeon, Jun-Man;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07e
    • /
    • pp.65-66
    • /
    • 2006
  • The speciality of education installation has to be applied to the design construction, inspection of school in the installation. But. it was applied general electric installation standards in korea. Therefore, the electric shock accidents and fire was more frequently occurred in the school than in other building. So, this paper, is proposed the comprehensive countermeasure for safety of school electric installation

  • PDF

Comparison and Analysis of Cometic and Foreign Standard for electrical facilities installation of entertainment spaces (유흥장 전기설비 설치에 대한 국내.외 규정 비교 분석)

  • Bae, Seok-Myung;Bang, Sun-Bae;Yi, Geon-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.321-325
    • /
    • 2004
  • Electrical facilities of entertainment spaces become more complicate and bigger due to growing industry and economy. Therefore using only Technical standards for Electrical facilities of internal standard, we have some difficulty for management and installation of electrical facilities of entertainment spaces. So this paper gives a information which is applied to install the electrical facilities of entertainment space by analysing and comparing of internal and external standard.

  • PDF

Effects of Security Lighting Lamps on Discomfort Glare to Indoor Occupants

  • Lee, Yoon Jeong;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.15 no.4
    • /
    • pp.21-28
    • /
    • 2015
  • Purpose: Although security lights are used to secure pedestrian visibility and safety at nighttime, they can generate light trespass in the neighboring residential space. To prevent this, standards for acceptance limits on vertical illuminance and light pollution by the windows of residential buildings are presented. Method: This study thus representatively selected three types of lamps and, through an evaluation and analysis of the physical and subjective discomfort glare per lamp, proposed a discomfort glare index for each lamp. The evaluation and analysis according to the lamps were conducted through experiments. The variables were the security lights' lamps (NH 100W, MH 70W, LED 50W), installation angles ($0^{\circ}$, $20^{\circ}$), and installation distances (3m, 5m, 7m, 9m). Result: According to the results of the discomfort glare evaluation depending on the angles and distances of the security lights, the following minimum standards are proposed: for NH 100W, a discomfort glare index of 30 and an installation distance of 4m; for MH 70W, a discomfort glare index of 32 and an installation distance of 4m; and, for LED 50W, a discomfort glare index of 31 and an installation distance of 6m, respectively. In addition, this paper recommends the use of MH 70W, when the road width is 4m-6m, and LED 50W, when the road width is over 6m, respectively.

Investigation on the Spot for Grounding Systems in Buildings

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Kim, Hyang-Kon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.3
    • /
    • pp.39-45
    • /
    • 2010
  • This paper deals with investigation on the spot for grounding systems of buildings based on international standards at construction sites. The investigation was carried out for grounding method, grounding type, shape of grounding electrode, grounding for a lightning protection system, continuity of steelwork in reinforced concrete structures, etc. The investigation on the spot was performed by a researcher and engineer with over fifteen years of industry experience all over the country. As a result of the investigation on the spot in 13 buildings, common grounding and structure grounding methods were dominant. The safety improvement methods include installation of equipotential bonding conductors for the connection to the main earthing terminal, equipotential bonding conductors for supplementary bonding, use of Surge Protective Devices (SPD), and safe connections between earthing conductors and the rebar.

An Analysis of Performance Testing for Metallic Connection Components of Lightning Protection System (피뢰시스템 구성부품 중 금속접속재의 성능시험 및 결과분석)

  • Lee, Ju-Cheol;Lee, An-Ki;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.7
    • /
    • pp.69-74
    • /
    • 2014
  • Recently, IEC published new standards about the requirements and tests for lightning protection system(LPS) components. If components are used for LPS, they should comply with the IEC standards. This paper, we collected six specimens for the metallic connection components using in domestic, and it tested for withstand lightning current which according to the IEC 62561-1. As a result, only one specimen meet this performance requirement. The specimen is the metallic connection component with four bolts fixed. Therefor, when designing of LPS in domestic, the metallic connection components shall be taken into account for the selection of the withstand lightning current. In addition, we need to develop for LPS components product and the national standards.