• Title/Summary/Keyword: standard reference materials

Search Result 355, Processing Time 0.027 seconds

Characterization of few-layered reduced graphene oxide (rGO) for standardization (소수의 층을 갖는 환원 graphene oxide(rGO) 표준화를 위한 물성분석)

  • Ahn, Hae Jun;Huh, Seung Hun;Jee, Youngho;Lee, Byeong Woo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.32 no.6
    • /
    • pp.239-245
    • /
    • 2022
  • Reduced graphene oxide (rGO) has attracted many attention and applications due to its excellent electrochemical ability. Therefore, standardization of rGO through structural and thermal analysis facilitates quality improvement and management, enabling users to increase efficiency and reduce relevant costs. For rGO and graphene-related materials, it is very important to determine the number of layers and define the resulting difference in physical properties. In this study, 3~4 layers of rGO-1 and 9~10 layers of rGO-2 were obtained from graphene oxide (GO) through a hydrazine reduction process. For the prepared rGOs, X-ray diffraction (XRD) pattern obtained a diffraction peak at 2θ≈25° related to (002) reflection was used to calculate the layer numbers by determining interlayer distance and FWHM value. To reduce the angular uncertainty, XRD data analysis was performed with angle correction using standard reference materials for X-ray powder diffraction analysis. Precise interlayer distance and number of layers were determined using OriginLab and open-source XRD diffraction analysis programs using the angle-corrected diffraction data. TG-DSC thermal analysis was performed to further standardize the physical properties of rGO samples.

Study on Radioactive Material Management Plan and Environmental Analysis of Water (II) Study of Management System in Water Environment of Japan (물 환경의 방사성 물질 관리 방안과 분석법에 관한 연구 (II) 일본의 물 환경 방사성물질 관리 체계에 대한 고찰)

  • Han, Seong-Gyu;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.305-313
    • /
    • 2015
  • After Fukushima Daiichi nuclear disaster in 2011, study and maintenance of monitoring systems have been made at home and abroad. As concerns about radioactive contamination of water have increased in Korea, update of maintenance of managing radioactive materials in water is being made mainly by Ministry of Environment. In this study, we analysed current state of monitoring system modification in Japan, the country directly involved and neighboring country. According to the result, Japan modified the legislations first. Then Ministry of Education, Culture, Sports, Science and Technology (MEXT) provides theoretical background of radiological monitoring. And Ministry of the Environment actually watches state of water pollution in public waters and underground water. Finally related agencies like local government are monitoring current state of radioactive contamination in water environment. By region, local monitoring stations share the investigation of the whole country. Also, additional monitoring is running around nuclear facilities. After Fukushima disaster, monitoring for area near Fukushima is added. Among the reference levels, management target value of drinking water and tap water is 10 Bq/kg, and those of public water and underground water are 1 Bq/L. Measuring intervals varied from every hour to once a year, regularly or irregularly depending on the investigation. The main measuring items are air dose rate, gross ${\alpha}$, gross ${\beta}$, ${\gamma}$ radionuclide, Cs-134, Cs-137, Sr-89, Sr-90, I-131, and so on. In comparison, regulations about general public water in Korea need to be modified, while those about area near nuclear facility and drinking water are organized well. In future, therefore, domestic system would be expected to be modified with making reference to the guidelines like WHO's one. As good case of applying international guideline to domestic environment, Japanese system could be a reference when general standard of radioactivity in public water is made in Korea.

Monitoring of Sulfur Dioxide, Carotenoid Contents and Bacillus cereus Contamination of Dried Sweet Potato in Circulating Dried Agricultural Products (국내 유통 건조 농산물 중 고구마 말랭이의 이산화황, 카로티노이드 함량 및 바실러스 세레우스오염 정도 조사)

  • Lee, Hyeon Min;Park, Hyun Ji;Kim, Ji Na;Shin, Weon Sun;Kim, Eun Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.6
    • /
    • pp.477-484
    • /
    • 2017
  • This study was conducted to investigate the content of sulfur dioxide, carotenoids and the degree of contamination of Bacillus cereus in 33 kinds of dried sweet potato from domestic mainly dried agricultural products in Korea. According to the characteristics of dried sweet potato samples, it was classified into four clusters and as a result of analyzing the contents of sulfur dioxide, carotenoids and the degree of contamination B. cereus was no significant difference among the clusters. The detection ranges of residual sulfur dioxide from 33 dried sweet potatoes ranged from 0.38 to 28.16 mg/kg, three cases (9.09%) were detected at the reference level of 10 mg/kg or more. But no samples exceeding 30 mg/kg, the tolerance level of sulfur dioxide in dried sweet potatoes were detected. Since dried sweet potato does not have a standard for carotenoids, when comparing the national and international standards of carotenoids, the range of detection of carotenoids in dried sweet potato was $46{\sim}2,663{\mu}g$/100 g, which was within the reference range of $0{\sim}9,826{\mu}g$/100 g. In principle colonies suspected to be B. cereus in dried sweet potato were not detected. In 7 cases (21.21%), there were detected in the range of 0.05~1.59 log CFU/g but not more than 3 log CFU/g as the reference value. The results of this study are expected to be used as basic data to establish quality standard for dried sweet potatoes. In order to control the quality of dried sweet potatoes in domestic market, raw materials, drying method and packaging after distribution, it is necessary to maintain and maintain the process steadily.

Marine Ecotoxicological Assessment Using the Nauplius of Marine Harpacticoid Copepod Tigriopus japonicus (저서성 해산 요각류 harpacticoid Tigriopus japonicus 유생을 이용한 해양생태독성평가)

  • Yoon Sung-Jin;Park Gyung-Soo;Oh Jeong-Hwan;Park Soung-Yun
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.9 no.3
    • /
    • pp.160-167
    • /
    • 2006
  • Harpacticoid copepod Tigriopus japonicus is widely distributed in coastal waters of Korea and plays important role in marine trophic structure as a first consumer. In this study, a series of experiment were conducted to test the potential of the species as a standard test species for marine bioassay. Tolerance on salinity and pH, sensitivity on the reference materials(copper sulfate and cadmium chloride) and response on the ocean dumping materials(waste sludge) we re tested to identify if the species satisfy the basic criteria as standard species for marine bioassay. The nauplius of the species($100{\sim}200{\mu}m$) showed wide tolerance on salinity with >90.0% survival rates exposed to $5.0{\sim}35.0psu$ for 48 h. Wide adaptability on pH's were also observed from 6.3 to 8.2 with >90.0% survival rates during the test. $LC_{50}$ values for copper sulfate and cadmium chloride were $3.6{\pm}0.7ppm,\;1.7{\pm}0.8ppm$, respectively. The variations in mortality between replicates were less than 10.0%. Comparison of $LC_{50}$ values indicated that T. japonicus nauplius was lower sensitive to copper sulfate than the most marine crustaceans included copepods, however, the sensitivity of test animal to cadmium chloride higher than the adults of copepod T. japonicus, Paracalanus parvus, and marine rotifer Brachinonus plicatilis. There were significant concentration-response relationship in the mortality of T. japonicus nauplius using the elutriates of three ocean dumping materials(industrial waste sludge). 48 h $LC_{50}$ values we re $31.1{\pm}1.1%$ for the elutriate of sludge from leather processing company and $54.4{\pm}15.1%$ for that of dye production company. Based on the above experimental results, bioassay using benthic harpacticoid T. japonicus nauplius must be a good estimation tool for marine ecotoxicological assessment of waste or chemicals. Wide tolerance on the salinity and pH, and significant linear relationship between concentration and response(mortality) supported the high potential of the species as a standard test species.

  • PDF

Evaluation of the accuracy of three different intraoral scanners for endocrown digital impression: An in vitro study (엔도크라운 디지털 인상을 위한 구강스캐너 3종의 정확도 평가: 실험실 연구)

  • Ural, Cagri;Park, Ji-Man;Kaleli, Necati;Caglayan, Esma
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.282-289
    • /
    • 2020
  • Purpose: The aim of this in vitro study was to evaluate the accuracy of three different intraoral scanners (IOSs) on digital impressions of different types of endocrown cavity preparations. Materials and methods: Two human mandibular molar teeth were prepared with different endocrown abutment designs: one with a buccal wall (Class 2) and the other without a buccal wall (Class 3). Both cavity designs were scanned using a reference desktop scanner (E3) and three different intraoral scanners: Trios3 (TRI group), Cerec Omnicam (CER group), and i500 (I5 group). The obtained Standard Tessellation Language (.stl) datasets were exported to metrology software. The precision was evaluated based on deviations among repeated scan models recorded by each IOS. The trueness was evaluated based on deviations between the reference data and repeated scans. For detecting interaction, data were statistically analyzed using a univariate analysis of variance (ANOVA) and for analyzing the comparison of the test groups data were analyzed by one-way ANOVA and post-hoc Tukey test at the significance level of .05. Results: The deviation values for both cavity designs in the I5 group were significantly lower than those in the other IOS groups in terms of trueness. For both cavity designs, the TRI group exhibited better precision than the other IOS groups. Conclusion: Different technologies of IOS device's and different endocrown prepration designs affected the accuracy of the digital scans.

Inter-laboratory Comparison for Analyses of Heavy Metals and Organic Solvent Metabolites in Biological Samples (생체시료 중 중금속 및 유기용제 대사물 분석의 실험실간 정도관리 프로그램)

  • Yang, Jeong Sun;Lee, Mi Young;Park, In Jeong;Kang, Seong-Kyu
    • Analytical Science and Technology
    • /
    • v.13 no.2
    • /
    • pp.258-267
    • /
    • 2000
  • The result of five year's experience on Inter-laboratory Comparison for Analyses of Heavy Metals and Organic Solvent Metabolites in Biological Samples was described. Since 1995, around a hundred laboratories in the Occupational Health have participated this program twice per year by the Industrial Safety and Health Law. Four metals in blood and five organic solvent metabolites in urine were examined. Reference samples were made by spiking standard materials to human blood or urine pools treated previously to give homogeneity and stability for a specific time periods. Some reference samples for organic solvent metabolites were made from workers' urine who were exposed to the organic solvents. Some items such as Lead in blood and Hippuric acid in urine showed good accordance between participants while the other items such as Mercury and N-methylformamide in urine showed poor proficient rate. The results were published in the internet or newspaper to help the consumer of the laboratory's service to get the information on them and to make competition between them. The inter-laboratory's comparison program have done greate role to improve the ability of analysis and reliability of analytical data produced from each laboratory.

  • PDF

Functional knee test in sports injury (스포츠 손상에서 슬관절 기능 검사의 의의)

  • Moon, Hyung-Tae;Seo, Jung-Gook;Ha, Jeong-Ku;Kim, Ji-Yeong;Kim, Min-Gun;Kim, Jin-Goo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.4 no.2
    • /
    • pp.109-115
    • /
    • 2005
  • Purpose: The purpose of this study was to evaluate the effectiveness of three functional performance tests and one-legged hop test and to establish the reference data of the three functional performance tests of the active young Korean men. Materials and methods: We performed five tests on 40 normal subjects such as one-legged hop test (single hop, triple hop) and the three functional performance tests (carioca test, co-contraction test, shuttle run test). The mean age was 28.4 years. The mean score of Tegner activity scale was 6.2 and Lysholm score 98.2 Mean value and standard deviation were obtained. The correlation of age, height and weight with the results, the relationship between FPT and one-legged hop test and the mean difference between dominant and non-dominant limbs were statistically calculated. Results: All data obtained were normally distributed and there were no significant relationship between age, height and weight. The paired t-test of one legged hop test showed no statistical significance between dominant and non-dominant limbs. The results of one legged hop test had strong relationship with functional performance test. Conclusion; The three functional performance tests can be a useful functional test in ACL-insufficient athletes. Our results can be used as normal reference data of the normal active Korean men.

  • PDF

Performance Evaluation of KOMPSAT-3 Satellite DSM in Overseas Testbed Area (해외 테스트베드 지역 아리랑 위성 3호 DSM 성능평가)

  • Oh, Kwan-Young;Hwang, Jeong-In;Yoo, Woo-Sun;Lee, Kwang-Jae
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_2
    • /
    • pp.1615-1627
    • /
    • 2020
  • The purpose of this study is to compare and analyze the performance of KOMPSAT-3 Digital Surface Model (DSM) made in overseas testbed area. To that end, we collected the KOMPSAT-3 in-track stereo image taken in San Francisco, the U.S. The stereo geometry elements (B/H, converse angle, etc.) of the stereo image taken were all found to be in the stable range. By applying precise sensor modeling using Ground Control Point (GCP) and DSM automatic generation technique, DSM with 1 m resolution was produced. Reference materials for evaluation and calibration are ground points with accuracy within 0.01 m from Compass Data Inc., 1 m resolution Elevation 1-DSM produced by Airbus. The precision sensor modeling accuracy of KOMPSAT-3 was within 0.5 m (RMSE) in horizontal and vertical directions. When the difference map was written between the generated DSM and the reference DSM, the mean and standard deviation were 0.61 m and 5.25 m respectively, but in some areas, they showed a large difference of more than 100 m. These areas appeared mainly in closed areas where high-rise buildings were concentrated. If KOMPSAT-3 tri-stereo images are used and various post-processing techniques are developed, it will be possible to produce DSM with more improved quality.

Prognosis for Pneumonic-Type Invasive Mucinous Adenocarcinoma in a Single Lobe on CT: Is It Reasonable to Designate It as Clinical T3?

  • Wooil Kim;Sang Min Lee;Jung Bok Lee;Joon Beom Seo;Hong Kwan Kim;Jhingook Kim;Ho Yun Lee
    • Korean Journal of Radiology
    • /
    • v.23 no.3
    • /
    • pp.370-380
    • /
    • 2022
  • Objective: To compare pneumonic-type invasive mucinous adenocarcinoma (pIMA) confined to a single lobe with clinical T2, T3, and T4 stage lung cancer without pathological node metastasis regarding survival after curative surgery and to identify prognostic factors for pIMA. Materials and Methods: From January 2010 to December 2017, 41 patients (15 male; mean age ± standard deviation, 66.0 ± 9.9 years) who had pIMA confined to a single lobe on computed tomography (CT) and underwent curative surgery were identified in two tertiary hospitals. Three hundred and thirteen patients (222 male; 66.3 ± 9.4 years) who had non-small cell lung cancer (NSCLC) without pathological node metastasis and underwent curative surgery in one participating institution formed a reference group. Relapse-free survival (RFS) and overall survival (OS) were calculated using the Kaplan-Meier method. Cox proportional hazard regression analysis was performed to identify factors associated with the survival of patients with pIMA. Results: The 5-year RFS and OS rates in patients with pIMA were 33.1% and 56.0%, respectively, compared with 74.3% and 91%, 64.3% and 71.8%, and 46.9% and 49.5% for patients with clinical stage T2, T3, and T4 NSCLC in the reference group, respectively. The RFS of patients with pIMA was comparable to that of patients with clinical stage T4 NSCLC and significantly worse than that of patients with clinical stage T3 NSCLC (p = 0.012). The differences in OS between patients with pIMA and those with clinical stage T3 or T4 NSCLC were not significant (p = 0.11 and p = 0.37, respectively). In patients with pIMA, the presence of separate nodules was a significant factor associated with poor RFS and OS {unadjusted hazard ratio (HR), 4.66 (95% confidence interval [CI], 1.95-11.11), p < 0.001 for RFS; adjusted HR, 4.53 (95% CI, 1.59-12.89), p = 0.005 for OS}. Conclusion: The RFS of patients with pIMA was comparable to that of patients with clinical stage T4 lung cancer. Separate nodules on CT were associated with poor RFS and OS in patients with pIMA.

Preparation of Pure CO2 Standard Gas from Calcium Carbonate for Stable Isotope Analysis (탄산칼슘을 이용한 이산화탄소 안정동위원소 표준시료 제작에 대한 연구)

  • Park, Mi-Kyung;Park, Sunyoung;Kang, Dong-Jin;Li, Shanlan;Kim, Jae-Yeon;Jo, Chun Ok;Kim, Jooil;Kim, Kyung-Ryul
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.18 no.1
    • /
    • pp.40-46
    • /
    • 2013
  • The isotope ratios of $^{13}C/^{12}C$ and $^{18}O/^{16}O$ for a sample in a mass spectrometer are measured relative to those of a pure $CO_2$ reference gas (i.e., laboratory working standard). Thus, the calibration of a laboratory working standard gas to the international isotope scales (Pee Dee Belemnite (PDB) for ${\delta}^{13}C$ and Vienna Standard Mean Ocean Water (V-SMOW) for ${\delta}^{18}O$) is essential for comparisons between data sets obtained by other groups on other mass spectrometers. However, one often finds difficulties in getting well-calibrated standard gases, because of their production time and high price. Additional difficulty is that fractionation processes can occur inside the gas cylinder most likely due to pressure drop in long-term use. Therefore, studies on laboratory production of pure $CO_2$ isotope standard gas from stable solid calcium carbonate standard materials, have been performed. For this study, we propose a method to extract pure $CO_2$ gas without isotope fractionation from a solid calcium carbonate material. The method is similar to that suggested by Coplen et al., (1983), but is better optimized particularly to make a large amount of pure $CO_2$ gas from calcium carbonate material. The $CaCO_3$ releases $CO_2$ in reaction with 100% pure phosphoric acid at $25^{\circ}C$ in a custom designed, evacuated reaction vessel. Here we introduce optimal procedure, reaction conditions, and samples/reactants size for calcium carbonate-phosphoric acid reaction and also provide the details for extracting, purifying and collecting $CO_2$ gas out of the reaction vessel. The measurements for ${\delta}^{18}O$ and ${\delta}^{13}C$ of $CO_2$ were performed at Seoul National University using a stable isotope ratio mass spectrometer (VG Isotech, SIRA Series II) operated in dual-inlet mode. The entire analysis precisions for ${\delta}^{18}O$ and ${\delta}^{13}C$ were evaluated based on the standard deviations of multiple measurements on 15 separate samples of purified $CO_2$. The pure $CO_2$ samples were taken from 100-mg aliquots of a solid calcium carbonate (Solenhofen-ori $CaCO_3$) during 8-day experimental period. The multiple measurements yielded the $1{\sigma}$ precisions of ${\pm}0.01$‰ for ${\delta}^{13}C$ and ${\pm}0.05$‰ for ${\delta}^{18}O$, comparable to the internal instrumental precisions of SIRA. Therefore, we conclude the method proposed in this study can serve as a way to produce an accurate secondary and/or laboratory $CO_2$ standard gas. We hope this study helps resolve difficulties in placing a laboratory working standard onto the international isotope scales and does make accurate comparisons with other data sets from other groups.