• Title/Summary/Keyword: standard of diagnosis

Search Result 1,211, Processing Time 0.024 seconds

In-situ Performance Test and Prediction of a 10 RT Air Source Heat Pump (10RT급 공기열원 열펌프의 현장 성능측정 및 예측)

  • 김영일;백영진;장영수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.3
    • /
    • pp.221-230
    • /
    • 2002
  • In this study, in-situ performance test of an air source heat pump which has a arted capacity of 10 RT is carried out. Since test conditions, such as indoor and outdoor air conditions cannot be controlled to satisfy the standard test conditions, experiments are done with the inlet air conditions as they exist. To estimate the performance for other conditions, he heat pump is modeled with a small number of selected parameters. The values of the parameters are determined from the few measurements measured on-site during normal operation. A simulation program is developed to calculate cooling capacity and power consumption t any other operating conditions. The simulation results are in good agreement with the experiment. This study provides a method of an on-site performance diagnosis of an air source heat pump.

Case Study on Engine Trouble analysis and Diagnosis Using MDA (MDA를 이용한 엔진 가속 불량 진단에 관한 연구)

  • Hwang, Sung-Wan;Cha, Suk-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.9
    • /
    • pp.105-109
    • /
    • 2022
  • In this study, the cause of the acceleration failure of Hyundai Motor's 2.0-liter CRDi engine was analyzed. We tried to find problems through MDA (Measuring Data Analyzer) based on data such as vehicle speed, air intake, and air-fuel ratio obtained during the actual driving process. As a result, it was analyzed that the failure of the EGR valve exceeded the NOx emission standard and caused a decrease in engine output. Through this study, it is possible to reduce the time and cost of unnecessary maintenance and repair, and it is expected that a rapid cause analysis will be possible in the case of new failure diagnosis in the future.

A Study on 『Bihuayijing·Vol 1』 -Focusing on Diagnosis and Pattern Differentiation- (『필화의경(筆花醫鏡)·권일(卷一)』에 대한 연구(硏究) - 진단 및 변증을 중심으로 -)

  • Kim, Yeon-Tae;Kim, Yong-Jin
    • Journal of Korean Medical classics
    • /
    • v.33 no.1
    • /
    • pp.17-28
    • /
    • 2020
  • Objectives : Classical texts such as 『Donguibogam』 and 『Yixuerumen』 have previously been used as primers to students of Korean Medicine. However, their massiveness in volume and comprehensiveness in contents make it unfit for students whose school curriculum lacked classical chinese. This paper suggests another introductory text that would be more practical in the current situation. Methods :Based on the translation of the main text and annotations, the clinical meanings of the contents were studied. Afterwards its practical application as a primer was considered. Results : The text focuses on the medically important issues in simple and accessible form, making it an important text for beginners to establish the foundation in medicine. Conclusions : Beginners will be able to establish a standard for basic medical knowledge through this text and also apply its contents to diseases that are relatively easy to treat.

Optimization of Waste Pneumatic Transportation System by Results of Facility Diagnosis (생활폐기물 관로이송시스템의 진단과 최적화 방안)

  • Chung, Won-Sik
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.5
    • /
    • pp.54-57
    • /
    • 2010
  • The purpose of this article is to diagnosis all aspects of waste pneumatic transportation system, in order to provide everyone interested in the subject with a optimal design and management of the system. The results of the analyzed inlet boxes were especially designed for customers' convenience and automatically operation, side air intake, ensure good wear. And key of pipelines were showed design standard as degree of an angle. Also, the system is mostly equipped with automatic control and watch conducted inside the waste collection facilities, and it will cut down excessive manpower and be able to be managed by least trained personnel.

In Vivo Doppler-Based Measurement of Bending Vibration Velocity in Liver Vibrated by Lo7v Frequency Signal (초음파 Doppler법에 의한 비침투적인 생체조직의 진동속도 계측)

  • 박무훈;장윤석
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.407-412
    • /
    • 1997
  • In this paper, we present a new method to diagnose the characteristics of the soft tissue, especially a liver. In order to diagnose the characteristics of a liver, it is necessary to evaluate the propagation delay time and propagation velocity of bending vibration In a liver. For this purpose, we measure the propagation velocity of bending vibration in a liver for low frequency forced vibration using a standard ultrasonic Doppler diagnosis equipment. We have carried out preliminary experiments by using an ultrasonic probe of 3.5MHz and obtained some results. This new measurement method developed here can be applied to new research and medical fields for acoustic non-invasive diagnosis of soft tissue.

  • PDF

An Aggressive Large Epithelioid Hemangioendothelioma of the Anterior Mediastinum in a Young Woman

  • Dutta, Roman;Pal, Harish;Garg, Garima;Mohanty, Sambit
    • Journal of Chest Surgery
    • /
    • v.51 no.6
    • /
    • pp.419-422
    • /
    • 2018
  • Hemangioendothelioma is a rare vascular tumor with involvement of the liver, brain, long bones, and lung. Among the 6 histological subtypes, epithelioid hemangioendothelioma (EHE) is the most aggressive. Its occurrence in the mediastinum is quite rare, and very few cases have been documented. The reported cases in the literature have described difficulties in the preoperative diagnosis due to the unusual histological appearance of the tumor. Immunohistochemistry remains the mainstay for a definitive diagnosis. Due to its low incidence, there is no standard treatment for mediastinal EHE, but curative resection is the preferred treatment option where possible, with chemotherapy used as an adjuvant treatment or in cases of widespread inoperable disease. The present case study describes an aggressive EHE occurring in an 18-year-old woman in the anterior mediastinum.

Halo, Reversed Halo, or Both? Atypical Computed Tomography Manifestations of Coronavirus Disease (COVID-19) Pneumonia: The "Double Halo Sign"

  • Antonio Poerio;Matilde Sartoni;Giammichele Lazzari;Michele Valli;Miria Morsiani;Maurizio Zompatori
    • Korean Journal of Radiology
    • /
    • v.21 no.10
    • /
    • pp.1161-1164
    • /
    • 2020
  • The epidemic of 2019 novel coronavirus, later named as coronavirus disease (COVID-19), began in Wuhan, China in December 2019 and has spread rapidly worldwide. Early diagnosis is crucial for the management of the patients with COVID-19, but the gold standard diagnostic test for this infection, the reverse transcriptase polymerase chain reaction, has a low sensitivity and an increased turnaround time. In this scenario, chest computed tomography (CT) could play a key role for an early diagnosis of COVID-19 pneumonia. Here, we have reported a confirmed case of COVID-19 with an atypical CT presentation showing a "double halo sign," which we believe represents the pathological spectrum of this viral pneumonia.

Implementation of a portable telemetry system based on wavelet transform. (웨이블릿 알고리즘을 적용한 휴대용 텔레미트리 시스템)

  • 박차훈;서희돈
    • Proceedings of the IEEK Conference
    • /
    • 2000.06e
    • /
    • pp.113-116
    • /
    • 2000
  • In this paper presents the portable wireless ECG data detection and diagnosis system based on discreet wavelet transform. An algorithm based on wavelet transform suitable for real time implementation has been developed in order to detect ECG characteristics. In particular, QRS complex, S and T waves may be distinguished form noise, baseline drift or artifacts. Proposed telemetry system that a transmitting media using radio frequency(RF) for the middle range measurement of the physiological signals and receiving media using optical for electromagnetic interference problem. A standard hi-directional serial communication interface between the telemetry system and a personal computer or laptop, allows read-time controlling, diagnosing and monitoring of system. A portable telemetry system within a size. of 65${\times}$125${\times}$45mm consists of three parts: a digital signal processing part for physiological signal detect or diagnose, RF transmitter for data transfer and a optical receiver for command receive. Advantages of proposed telemetry system is wireless middle range(50m) FM transmission, reduce electromagnetic interference to a minimum. which enables a comfortable diagnosis system at home.

  • PDF

Maturity-onset Diabetes of the Young: Update on Diagnosis and Treatment

  • Jang, Kyung Mi
    • Journal of Interdisciplinary Genomics
    • /
    • v.3 no.1
    • /
    • pp.1-6
    • /
    • 2021
  • Maturity-onset diabetes of the young (MODY) is characterized by a heterogeneous group of monogenic diabetes. MODY has autosomal dominant inheritance, a primary defect in pancreatic β-cell, and an early onset. Discriminating MODY from type 1 or type 2 diabetes is often challenging at first. To date, 14 different disease causing mutations have been identified in MODY patients worldwide. Targeted DNA sequencing is the gold standard to diagnose MODY and their asymptomatic relatives. Next-generation sequencing may help successfully to diagnose MODY patients and identify new MODY genes. In this review, the current perspectives on diagnosis and treatment of MODY and discrepancy in the disease-causing mutations between the Asian and Caucasian patients with MODY are summarized.

A Study on the Improvement of Test and Diagnosis Device for Audio Frequency Track Circuit (가청주파수 궤도회로의 진단 및 시험 장비 개선에 대한 연구)

  • Kang, Jang-Kyu;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.147-155
    • /
    • 2010
  • We studied on performance improvement of TTM(TI21 Test Meter) that is test and diagnosis devices for jointless audio frequency track circuit on Korean electric railway TI21 standard. Upgraded devices is AD-TTM(Advanced TI21 Test Meter). This can measure alternating frequency USB(Upper signal band) and LSB(Lower signal band). In the audio frequency track circuit, ${\pm}17[Hz]$ of nominal frequency are demodulated and supplied to track relay through AND gate. It is important that measurement function which is error between USB and LSB. Need of AD-TTM will stand out in the electric railway system because this is simple and accurate rather than the former device.