• Title/Summary/Keyword: standard of diagnosis

Search Result 1,211, Processing Time 0.023 seconds

Temperature Distribution Monitoring of Transformer (변압기 온도 변화특성 모니터링)

  • Lee, Woo-Sun;Jung, Chan-Moon;Son, Dong-Min;Seo, Young-Jin;Lim, Jang-Sub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.69-72
    • /
    • 2002
  • The conventional thermal insulator and power transformer testing is widely used in surface aging measurement of outside insulator because those testing can carry out very short time in Lab testing. Also thermal testing is able to offer the standard judgement of relative degradation level of outside HV machine. There it is very useful method compare to previous conventional thermal testing method and effective Lab testing method. But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR-camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis. In this study, thermal testing of power transformer is measured with partial temperature distribution in real time.

  • PDF

A Study on Pulse Condition of Sameumsamyang(三陰三陽) in "Hwangjenaegyeong(黃帝內經)" ("황제내경(黃帝內經)"의 삼음삼양(三陰三陽) 맥상(脈象)에 대한 소고(小考))

  • Baik, You-Sang
    • Journal of Korean Medical classics
    • /
    • v.21 no.3
    • /
    • pp.119-125
    • /
    • 2008
  • Among the various pulse diagnosis contents in "Hwangjenaegyeong(黃帝內經)", we researched the pulse conditions that are belonged to Sameumsamyang(三陰三陽), and made a comparative study with pulse conditions of five organs[五臟], that of six meridians in "Sanghallon(傷寒論)". So from now on, this study would make help to understand standard pulse condition of Sameumsamyang(三陰三陽) diseases for clinical application. In "Hwangjenaegyeong(黃帝內經)", pulse condition of Taeyang(太陽) is expressed to be floating, Yangmyeong(陽明)'s condition to be strong but with a little bit weakness, Soyang(少陽)'s condition to be intermediate between Eum(陰) and Yang(陽), Taeeum(太陰)'s condition to be low and soft, So-eum(少陰)'s condition to be low and weak with some occasional upward tendency, Gweoleum(厥陰)'s condition to be mixed state of Eum and Yang.

  • PDF

Multiple Tuberculous Splenic Abscesses in a Child (소아에서 발생한 비장의 다발성 결핵성 미세농양 1예)

  • Park, Chan-Yong;Choi, Soo-Jin-Na;Chung, Sang-Young;Kim, Shin-Kon
    • Advances in pediatric surgery
    • /
    • v.12 no.2
    • /
    • pp.244-250
    • /
    • 2006
  • Splenic abscess is a rare clinical condition with a reported incidence of 0.14 % to 0.70 % in various autopsy series. Primary tuberculosis of the spleen as a cause of splenic abscess is even rarer, especially in the antitubercular era. Infants and children have a higher predisposition to extra-pulmonary tuberculosis than adults and tend to develop severe extra-pulmonary disease such as miliary tuberculosis and meningitis. The diagnosis of tuberculosis in infants and children can be difficult because of nonspecific symptoms and clinical findings. Computed tomography establishes the diagnosis of splenic abscess and demonstrates the number and location of abscesses. Splenectomy is the standard of care in most clinical setting. We present a 4-year-old girl who had multiple tuberculosis splenic abscesses and was treated successfully with splenectomy.

  • PDF

The Analysis of Weibull Distribution on the Monitoring of IRR Camera (적외선 모니터링 관측의 와이블 분포해석)

  • Lim, Jang-Seob;Kim, Jin-Gook;Lee, Hack-Hyun;Lee, Jin;Lee, Woo-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.264-267
    • /
    • 2004
  • The conventional testing as IEC-60587 is widely used in surface aging measurement of outside insulator those testing can carry out very short time in Lab testing. Also IEC-60587 testing is able to offer the standard judgement of relative degradation level of out side HV machine. Therefore it is very useful method compare to previous conventional tracking testing method and effective Lab testing method, But surface discharges(SD) have very complex characteristics of discharge pattern so it is required estimation research to development of precise analysis method. In recent, the study of IRR Camera is carrying out discover of temperature of power equipment through condition diagnosis and system development of degradation diagnosis.

  • PDF

Regression Analysis of Doubly censored data using Gibbs Sampler for the Incubation period

  • Yoo Hanna;Lee Jae Won
    • Proceedings of the Korean Statistical Society Conference
    • /
    • 2004.11a
    • /
    • pp.237-241
    • /
    • 2004
  • In standard time-to-event or survival analysis, the occurrence times of the event of interest are observed exactly or are right-censored. However in certain situations such as the AIDS data, the incubation period which is the time between HIV infection time and the diagnosis of AIDS is usually doubly censored. That is the HIV infection time Is interval censored and also the time of the diagnosis of AIDS is right censored. In this paper, we Impute the Interval censored infection time using the conditional mean imputation and estimate the coefficient factor of the regression analysis for the incubation period using Gibbs sampler. We applied parametric and semi-parametric methods for the analysis of the Incubation period and compared the results.

  • PDF

A Study on the Self-Diagnosis Criteria of Electrical Installations (자가용 전기설비의 자가진단 기준에 대한 연구)

  • Kim, Jong-Min;Lee, Hyeon-Woo;Kim, Hong-Ki;Yoo, Sang-Bong;Jang, Kyung-Bae
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.5
    • /
    • pp.863-869
    • /
    • 2017
  • This paper is to enable electrical safety manager to have more objective evaluation on the safety by indicating quantitative values such as life-time and status quotient of daily visual inspection on private electrical equipments. Self-diagnosis table is recommended to apply such a evaluation efficiently according to the characteristics of each electrical equipments, and the managers's determination of the precise inspection, replacement etc. will be also possible through the standard selected by various domestic and foreign data with expert's advise for numerical evaluation. This circumstance will be able to establish the foundation to secure the soundness of electrical equipments.

A Study on the Web-based Remote Pulse Diagnosis System (Web 기반 원격 맥진 시스템 구축에 관한 연구)

  • Lee, J.Y.;Lee, S.J.;Kim, J.H.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.2821-2822
    • /
    • 2001
  • This study has conducted researches in the web-based diagnosis data management system of pulse waveform as well as the method of transmitting the data of pulse waveform. In order to set the standard for the documents of the pulse waveform of patients, the web-based clinical database management system has been developed.

  • PDF

UsN based Soundness Monitoring Diagnosis System of Power Transmission Steel Tower (UsN 기반의 송전철탑 건전성 감시진단시스템 기본설계)

  • Lee, Dong-Cheol;Bae, Ul-Lok;Kim, Woo-Jung;Min, Bung-Yun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.56-62
    • /
    • 2007
  • In this paper, design method for power tower hazard diagnosis/predition system based on UsN was proposed. The proposed method used multi-hybrid sensors to measure rotation, displacement, and inclination state of power tower, and made decision/prediction of hazard of power tower. System design was made with requirement analysis of monitoring for transmission power facility and use of MEMS and optic fiber sensors. For hazard decision, analysis of correlation was made using sensor output. LN based on IEC61850,international standard for digital substation, was also proposed. For transmission facility monitoring, digital substation and power tower were considered as parts of power facility networks.

The Classification of Standard Nursing Activities in Korea (한국 표준 간호행위 분류)

  • 박정호;성영희;송미숙;조정숙;심원희
    • Journal of Korean Academy of Nursing
    • /
    • v.30 no.6
    • /
    • pp.1411-1426
    • /
    • 2000
  • A nursing activity classification for hospitalized patients was performed based on an article review regarding nursing definition and nursing activity classification system. The study was conducted as follows: 1) Taxonomy was developed by the research team through the Delphi process and review article. The taxonomy consists of four nursing processes, (assessment, diagnosis, intervention and evaluation) and twelve nursing activity domains space (resperation, nutrition, elimination, exercise/alignment maintenance, comfort, hygiene, safety, spiritual support, counseling/ education, medication, communication, patient and information management). 2) First, nursing activities of the intervention process were listed and then classified by the nursing process of assessment, diagnosis, intervention and evaluation. The list consists of twelve nursing activity domains and 136 nursing activities. 3) A pilot study was conducted in two hospitals to verify validity and appropriateness of nursing activities. 4) The content validity index, which was calculated by 6 clinical practice experts, was 0.95. Also, a nursing activity classification system should also be developed in the department of community nursing and home health care nursing.

  • PDF

Development of Tension Leveller Condition Monitoring and Diagnosis System (TENSION LEVELLER 상태감시 및 진단시스템 개발)

  • 신남호;김수광;최석욱
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.350-354
    • /
    • 1995
  • The Tension Leveller of Cold Rolling Mill In POSCO performs levelling the strip in high speed line. But minor variations in operating condition of driving machines such as motor, gear box, and support bearings, a small gap-variation of supporter and strip slip by poor roll revolutions can cause serious problems in the quality of strip. In this study, firstly, A condition monitoring standard for each sensor is made through with the detail analysis of vibration and strip slip. Secondly, An automatic monitoring and diagnosing system was developed to monitor the condition of Tension Leveller, and diagnose the cause of abnormal condition. Finally, A diagnosing algorithm for abnormal condition and man-machine interface (MMI) for easy operation are developed.

  • PDF