• 제목/요약/키워드: standard components

검색결과 1,584건 처리시간 0.029초

사용 조건하에서의 자동차용 커넥터 신뢰성 분석 (Reliability Analysis of Auto-Connector in Use-condition)

  • 김종걸;김진환
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2004년도 춘계학술대회
    • /
    • pp.129-136
    • /
    • 2004
  • Environmental factors for automotive consist of temperature, humidity, vibration(sine & random), gas, an electrical load and so on. These environmental factors are impressed in a automotive. Dependability is essential requirement in many electronic parts. Among components of automotive, the connector connecting electrical signals is one of the most important parts. Automotive -connector is inspected according to each manufacturer's test standard in which dependability should be considered. This paper aims to verify that current test standard is suitable for dependability, and present an inductive life test for automotive connector based on the field data in use-condition.

  • PDF

국내 연안 카페리 차량 고박 장치 안전성에 관한 연구: 제2부 가속도 예측 방법에 따른 고박 안전도 비교 연구 (Study on Structural Safety of Car Securing Equipment of Coastal Carferry: Part II Assessment of Lashing Safety according to Acceleration Prediction Approaches)

  • 정준모;조희상;이경훈;이영우
    • 한국해양공학회지
    • /
    • 제30권6호
    • /
    • pp.451-457
    • /
    • 2016
  • For a carferry with a displacement of 1,633 tonf, a seakeeping analysis-based direct load approach (DLA) was used in Part I of these series, where the final deliverable was the long-term probabilistic acceleration components. In Part II of these series, the tangential acceleration components are explained based on two approaches: a standard called the IMO CSS code and simple formulas with the probable maximum roll and pitch rotations. The subsequent tangential acceleration-induced external force components are also introduced for these two approaches. The lashing strength components were selected from the IMO CSS code. It was assumed that two different vehicles (a car and a truck) were stowed at the most distant locations on the main deck to assume the largest tangential acceleration components and were secured with four steel wires with longitudinal and transverse lashing angles of $45^{\circ}$. Four cases were considered, with different methods for predicting the acceleration components and different tools for the external loads and lashing strengths involved: cases Rule-LS (rule-based maximum probable roll and pitch angles for predicting the acceleration components in conjunction with LashingSafety), DLA-LS (seakeeping-based long-term acceleration components with LashingSafety), CSS-LC (IMO CSS code-based acceleration components using LashCon), and CSS-LS (IMO CSS code-based acceleration components using LashingSafety). In terms of the acceleration and external force components, the CSS-LC and CSS-LS results are more than two times the results of Rule-LS. Thus, when the external forces and lashing strengths are evaluated using CSS-LC and CSS-LS, the truck needs more lashing wires, while Rule-LS and DLA-LS predict that the present lashing configuration is on the safe side.

Establishment of a National Primary Inductance Standard Unit

  • Kim Han Jun;Lee Rae Duk;Semenov Yu. P.;Han Sang Ok
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제5B권3호
    • /
    • pp.283-288
    • /
    • 2005
  • A portable primary inductance standard set that includes a Maxwell-Wien bridge and a 10 mH standard inductor installed in a thermostat has been developed at KRISS. Two auxiliary resistance capacitance networks (analogous to a 'Wagner ground') provide excellent stability of the bridge balance and impose less strict requirements on the components of these networks. Removable capacitance and ac-dc resistance standards used in the bridge arms made it possible to reproduce 10 mH and 100 mH inductance values in the frequency range of 500 Hz to 3 kHz. From investigations of this standard and preliminary comparison with VNIIM (D. I. Mendeleyev Institute for Metrology), the results have demonstrated that the bridge can be used as a part of the transportable inductance standard with a measurement uncertainty within (1-3) $\mu$H/H at frequencies of 1 kHz and 1.6 kHz. The application of the bridge as a constituent part of the transportable standard gives us an opportunity to eliminate the influence of the standard inductors.

멀티모드 단말기의 라디오 라이브러리를 위한 표준 기능 블록의 선정 및 구현 (Selection and implementation of Standard Functional Blocks for Radio Library in multi-mode mobile device)

  • 정일도;최승원
    • 디지털산업정보학회논문지
    • /
    • 제12권3호
    • /
    • pp.125-132
    • /
    • 2016
  • The European Telecommunication Standards Institute (ETSI) Technical Committee (TC) Reconfigurable Radio Systems (RRS) is standardizing the multi-mode Mobile Device (MD). The configuration of multi-mode MD is determined by the downloaded mobile communication standard software. In this paper, we introduce the Radio Library concept for multi-mode MD which is one of the key components of RRS standard. This paper also introduces the Standard Functional Block which is a part of Radio Library. A method for selecting efficiency SFBs for multi-mode MD is presented and a Radio Library is generated based on the selected SFBs. This paper also shows sample Standard Functional Block Set which included in Radio Library. In order to verify the compatibility of the generated Radio Library which was made by C language, we implement the LTE Rel-10 and Wi-Fi(802.11b) to show the efficiency of generating a mobile communication standard software based on the Radio Library. Then using the Prograph Visual Programming MartenTM 1.6.4, we compiled our LTE Rel-10 and Wi-Fi(802.11b) source code.

압전소자를 이용한 에너지 하베스터용 전력변환장치 연구 (A Study of Power Conversion System for Energy Harvester Using a Piezoelectric Materials)

  • 안현성;김영철;차한주
    • 전기학회논문지
    • /
    • 제66권7호
    • /
    • pp.1059-1065
    • /
    • 2017
  • In this paper, the energy harvester with a piezoelectric materials is modeled as the electric equivalent circuit, and performances of a standard DC method and a Parallel-SSHI method are verified through experiment under variable force and load conditions. Piezoelectric generator consists of mass, damper and spring constant, and it is modeled by electrical equivalent circuit with RLC components. Standard DC and Parallel-SSHI are used as power conversion methods, and standard DC consists of full-bridge rectifier and smoothing capacitor. Parallel-SSHI method is composed of L-C resonant circuit, zero-crossing detector and full-bridge rectifier. In case of simulation under $100k{\Omega}$ load condition, the harvested power is $500{\mu}W$ in Standard DC and $670{\mu}W$ in Parallel-SSHI, respectively. In experiment, the harvested power under $100k{\Omega}$ load condition is $420{\mu}W$ in standard DC and $602{\mu}W$ in Parallel-SSHI. Harvested power of Parallel-SSHI is improved by approximately 40% more than that of standard DC method.

콘크리트용 표준물질(Standard Reference Materials)개발의 최적배합비율 결정을 위한 기초연구 (A Fundamental Study on the Determination of Optimal Mixing Ratio for Development of Standard Reference Materials for Concrete)

  • 이동규;최명성
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.111-118
    • /
    • 2019
  • Recently, a variety of special concrete structures have been designed in domestic and overseas construction markets and more advanced construction technology is required. Therefore, it is necessary to secure quantitative construction technology. For this purpose, it is essential to develop a standard reference material having a constant flow performance and quality to evaluate quantitative performance. On the other hand, the flowability of the concrete is greatly influenced by the flowability of the cement paste. Also, in consideration of design strength and workability, mix design is carried out at various mixing ratios according to the purpose of the site. Therefore, in this study, based on the derived components of standard reference materials for cement paste, we suggested mixing ratio of standard reference materials that can uniformly simulate the flow characteristics of cement paste according to W/C. As a result, it was found that the yield stress was determined by the ratio of water and glycerol but plastic viscosity was controled by limestone content. Finally, the ratio of standard reference materials to simulate the rheological range of cement paste by W/C was suggested.

해외 발전소 건설의 효율화를 위한 표준분류체계 상위구조 (Outline of Standard Classifications for International Power Plant Construction)

  • 강미연;하지원;정영수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.184-185
    • /
    • 2014
  • International construction contracts to Korean construction companies have been dramatically increased over the 48 years (Contract received worth 65.2 billion dollars in 2013). Especially, the plant construction sector has achieved about 61% among the 65.2 billion dollars. Under this trend, in order to ensure plant construction's competitiveness, 'standard classification' is an important area for systematic management. However, these standards in the plant construction are not widely utilized yet, in comparison with civil and building sectors. Therefore, in this research, a higher level of standard classifications is proposed for various types of power plants from a PMO's (Project Management Office) perspective. This study also provides a comparative analysis outlining different features and common components based on various types of power plants.

  • PDF

캘리포니아 표준 테스트 방법을 사용한 압전 발판의 경제성 분석 (Economic Analysis of the Piezoelectric Power using the California Standard Test)

  • 정순성
    • 동력기계공학회지
    • /
    • 제21권4호
    • /
    • pp.51-56
    • /
    • 2017
  • The purpose of this study is to suggest economic analysis for piezoelectric power. Economic analysis method uses california standard test. Perspectives of california standard test is participant test, ratepayer impact measure test, program administrator cost test and total resource cost test. This study identifies the cost and benefit components. This study identifies benefit-cost calculation procedures from four test : participant test, ratepayer impact measure test, program administrator cost test and total resource cost test. In the economic analysis, the order of benefit cost ratio in piezoelectric power shows total resource cost test, program administrator cost test, ratepayer impact measure test and participant test.

GC를 이용한 주류중 에탄올 및 유해 성분의 동시 분석법 (Simultaneous Analysis of Ethanol and Harmful Components by GC in Alcoholic Liquors)

  • 정의한;이명자;강금자;문혜성;유병옥;황정구;장준식
    • 한국식품위생안전성학회지
    • /
    • 제7권1호
    • /
    • pp.45-48
    • /
    • 1992
  • 우리나라의 식품 공전에서 주류의 검사방법이 비색 및 적정의 방법으로 나타나 있다. 그러나 이런 습식분석법은 시간이 많이 걸리고 개인오차 등 심각한 문제를 내포하고 있다. 주류의 제조 과정 중 휴겔류가 생성되는데 n-propanol, 2-propanol, n-butanol, i-butanol, i-amyl alcohol이 주로 생성된다. 우리는 GC를 이용하여 개개의 물질을 분리하고 농도에 따른 신호가 직선성이 얻어지면 동시에 정성 및 정량 자료를 얻을 수 있다. 즉 GC나 GC/MSD에 의해 capillary FFAP 칼럼을 이용하여, 다섯가지 휴젤성분, 아세트알데히드, 메탄올, 에탄올 그리고 내부표준물질인 아세토니트릴을 동시에 분리하였다. 그리고 capillary FFAP 칼럼으로 분리된 각 피이크가 단일종이라는 것을 GC/MSD를 이용하여 각각의 mass 스펙트럼으로 확인할 수 있었다. 또한 내부 표준법으로 GC에 의해 각 물질에 대한 좋은 정량자료를 얻었다.

  • PDF

Development of a Model System of Uncertainty Evaluations for Multiple Measurements by Isotope Dilution Mass Spectrometry: Determination of Folic Acid in Infant Formula

  • Kim, Byung-Joo;Hwang, Eui-Jin;So, Hun-Young;Son, Eun-Kyung;Kim, Yong-Seong
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권11호
    • /
    • pp.3139-3144
    • /
    • 2010
  • A model system has been established for the evaluation of the uncertainty of the value from measurements of multiple subsamples by isotope dilution mass spectrometry (IDMS). In this report, we apply this model system for the evaluation of measurement uncertainty in determination of folic acid in infant formula. Five subsamples were analyzed by IDMS. The mean of the measurement results of the five subsamples was assigned as the final measurement value. The standard deviation (s) of the results from five subsamples was attributable to repeatability of the measurement. The uncertainty components in the IDMS measurement methods were categorized into two groups. Group I includes uncertainty components which give common systematic effects to all subsamples and do not contribute to the variation among multiple measurements (repeatability). Group II includes uncertainty components that give random effects on the measurement results, and are related with the measurement repeatability. These random effects are attributed to s. Therefore, the uncertainty of the final value was calculated by combining the standard deviation of the mean of multiple measurements, $s/{\surd}n$ (where n = 5), and the measurement uncertainty associated with the uncertainty components that give systematic effects.