• Title/Summary/Keyword: standard cell

Search Result 1,454, Processing Time 0.025 seconds

Relationship of Somatic Cell Count, Physical, Chemical and Enzymatic Properties to the Bacterial Standard Plate Count in Different Breeds of Dairy Goats

  • Ying, Chingwen;Yang, Cheng-Bin;Hsu, Jih-Tay
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.4
    • /
    • pp.554-559
    • /
    • 2004
  • The objective of the present study was to investigate the accuracy of mastitis diagnostic indicators for different dairy goat breeds. Biweekly milk samples were collected from individual half mammary gland of seven Saanen and seven Alpine dairy goats in the period of 40 to 120 days in milk. With threshold value set at 2.8 and 3.1 for Alpine and Saanen dairy goats, respectively, log (SPC) offered good sensitivity (0.89, 0.93), specificity (0.88, 0.95), positive predictive value (0.75, 0.85) and negative predictive value (0.95, 0.98) as a mastitis diagnostic tool. The correlations of log (SPC) with milk yield, log (SCC), ALP, LDH, $Na^{+}$, $K^{+}$ and EC were significant in Saanen dairy goats (p<0.05), with the highest correlation coefficient (0.653) existing between log (SPC) and log (SCC). The correlations of log (SPC) with milk yield, milk fat, milk protein, log (SCC), $Na^{+}$, $K^{+}$, EC were significant in Alpine dairy goats (p<0.05), with the highest correlation coefficient (0.416) existing between log (SPC) and log (SCC). There were different best-fit regression equations with different multiple diagnostic indicators for Saanen and Alpine dairy goats. In conclusion, different breeds of dairy goats may have to adapt different mastitis diagnostic parameters for a better diagnosis.

Analysis of Comparison Test and Measurement Error Factor for I - V Performance of Photovoltaic Module (PV모듈 발전성능 비교시험과 계측편차 요인 분석)

  • Kang, Gi-Hwan;Kim, Kyung-Soo;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.2
    • /
    • pp.70-75
    • /
    • 2009
  • In this experiment, we did sampling 6 kinds of photovoltaic modules and analyzed the discrepancy of measurement results between l laboratory and 4 PV makers to have performance repeatability at Standard Test Condition(STC) condition. From the KIER's results, Korea's standard test laboratory, other laboratory showed -10% measurement variation. The causes came from correction of reference cell, test condition and the state of skill. Form the comparison test, we analyzed the problems. But three PV maker reduced measurement variation, other one PV maker and one test laboratory didn't improve the problems of correction of reference cell, test condition and the state of skill. Also, High Efficiency Module had a big discrepancy of -10.0$\sim$-6.2% among 3 laboratories which have a less than 10msec light pulse duration time. This made low spectrum response speed so the Fill Factor decreased maximum output power under 10msec light pulse duration time

VLSI Design of Data Manipulation Unit capable of bit partitioned shifts and various data type conversions (비트 분할 데이터 시프트 및 다양한 형식 변환이 가능한 데이터 처리기의 VLSI 설계)

  • 유재희
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.6C
    • /
    • pp.594-600
    • /
    • 2002
  • A data manipulation unit capable of bit partitioned shift and various multimedia data type conversions in addition to conventional shift, is presented. Utilizing the similarity between the data type conversion and the shift, the addition of small amount of interconnections to conventional barrel shifter enables data type conversion as well as shift operations with minimal hardware overhead. The presented data manipulation unit is composed of the shifter block for conventional shift and a pack and a unpack block. It has been designed with verilog HDL and the VLSI implementation results using compass 0.6 um standard cell are discussed.

Design of a Blind DFE Equalizer for high-speed data communication (고속 데이터 통신을 위한 Blind DFE Equalizer의 설계)

  • 박원흠;선우명훈
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.7C
    • /
    • pp.704-711
    • /
    • 2002
  • This paper proposes a DFE (Decision Feedback Equalizer) equalizer ASIC using the Multi-Modulus Algorithm (MMA) for cable modem applications. We believe that it is the first effort to combine the DFE structure and the MMA algorithm. The proposed equalizer has been designed for 64/256 QAM modems. The existing MMA equalizer uses two transversal filters and updates two tap weights while the proposed equalizer uses two DFE filter banks to improve the channel adaptive performance and to reduce the number of taps and updates only one tap weights. We have used the 0.35 $\mu\textrm{m}$ standard cell library. The implemented equalizer ASIC operates at 8 MHz and provides 64 Mbps which is higher than existing equalizers. The total number of gates are about 160,000.

A Study on Performance of Protective Gloves to Isocyanate Toxicity (이소시안화물 독성에 대한 보호장갑의 성능 연구)

  • Lee, Su-Gil;Pisaniello, Dino;Lee, Nae-Woo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.62-69
    • /
    • 2008
  • As the concerns of dermal exposure of spray painters to isocyanates in the automobile industry, glove performance was examined like permeation rate and breakthrough time including fatigue test. Methylene chloride was used as the solvent for derivatization of the isocyanates with a 97.5% recovery. Ghost wipe pads were used to wipe the surface of the glove material after chemical penetration through the glove material placed under a disposable test cell. Several solvents were tested, such as thinner(xylene, toluene) and cleaning agent(acetone) by using a standard permeation test cell(AS/NZS standard 2161. part 10.3). Solvents accelerate chemical permeation through the gloves more quickly than pure HDI hardener products. The longest breakthrough times were from Nitrosolve gloves, not detected in 8 hours, compared with others like Latex, Neoprene, TNT and Dermo Plus. Therefore Nitrosolve gloves could be recommended as personal protective equipment in crash repair shops. In addition, revised exposure limit of korean regulation should be suggested for employee to minimize the risk of health symptoms.

Recent Progress in Immunotherapy for Advanced Gastric Cancer (진행성 위암에 대한 면역 요법의 최신 지견)

  • Byeong Seok Sohn
    • Journal of Digestive Cancer Research
    • /
    • v.10 no.1
    • /
    • pp.22-30
    • /
    • 2022
  • Immune checkpoint inhibition has been established as a new treatment option for various types of carcinoma, and many clinical trials are being actively conducted as a treatment for advanced or metastatic gastric cancer, either as a monotherapy with an immune checkpoint inhibitor or as a combination therapy with standard chemotherapy. In the CheckMate-649 clinical trial to confirm the efficacy of the combination of nivolumab and chemotherapy (FP) in advanced gastric cancer and gastroesophageal junction cancer, nivolumab group showed improvement in overall survival in programmed death ligand 1-positive cancer patients compared with placebo group. Also, the combination therapy of pembrolizumab, trastuzumab and chemotherapy (FP) in first-line treatment was tested through the KEYNOTE-811 trial. The pembrolizumab group showed 22.7% of improvement in objective response rate compared with placebo group. Accordingly, the combination of nivolumab/pembrolizumab with standard chemotherapy was approved for the first-line treatment. In KEYNOTE-059 trials for patients with progressive disease after at least two lines of chemotherapy, pembrolizumab monotherapy showed improvement in objective response rate and overall survival, and the use of pembrolizumab was approved for the third-line or more treatment. In this article, we review the result of clinical trials related to immune checkpoint inhibitors that have been recently introduced in the treatment of gastric cancer.

Artificial Neural Network System in Evaluating Cervical Lymph Node Metastasis of Squamous Cell Carcinoma (편평세포암종 임파절 전이에 대한 인공 신경망 시스템의 진단능 평가)

  • Park Sang-Wook;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won;You Dong-Soo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.1
    • /
    • pp.149-159
    • /
    • 1999
  • Purpose: The purpose of this study was to evaluate cervical lymph node metastasis of oral squamous cell carcinoma patients by MRI film and neural network system. Materials and Methods: The oral squamous cell carcinoma patients(21 patients. 59 lymph nodes) who have visited SNU hospital and been taken by MRI. were included in this study. Neck dissection operations were done and all of the cervical lymph nodes were confirmed with biopsy. In MR images. each lymph node were evaluated by using 6 MR imaging criteria(size. roundness. heterogeneity. rim enhancement. central necrosis, grouping) respectively. Positive predictive value. negative predictive value. and accuracy of each MR imaging criteria were calculated. At neural network system. the layers of neural network system consisted of 10 input layer units. 10 hidden layer units and 1 output layer unit. 6 MR imaging criteria previously described and 4 MR imaging criteria (site I-node level II and submandibular area. site II-other node level. shape I-oval. shape II-bean) were included for input layer units. The training files were made of 39 lymph nodes(24 metastatic lymph nodes. 10 non-metastatic lymph nodes) and the testing files were made of other 20 lymph nodes(10 metastatic lymph nodes. 10 non-metastatic lymph nodes). The neural network system was trained with training files and the output level (metastatic index) of testing files were acquired. Diagnosis was decided according to 4 different standard metastatic index-68. 78. 88. 98 respectively and positive predictive values. negative predictive values and accuracy of each standard metastatic index were calculated. Results: In the diagnosis of using single MR imaging criteria. the rim enhancement criteria had highest positive predictive value (0.95) and the size criteria had highest negative predictive value (0.77). In the diagnosis of using single MR imaging criteria. the highest accurate criteria was heterogeneity (accuracy: 0.81) and the lowest one was central necrosis (accuracy: 0.59). In the diagnosis of using neural network systems. the highest accurate standard metastatic index was 78. and that time. the accuracy was 0.90. Neural network system was more accurate than any other single MR imaging criteria in evaluating cervical lymph node metastasis. Conclusion: Neural network system has been shown to be more useful than any other single MR imaging criteria. In future. Neural network system will be powerful aiding tool in evaluating cervical node metastasis.

  • PDF

Performance Analysis of PCM Cell Search Algorithm for Fast Cell Search in WCDMA Systems (WCDMA. 시스템에서 빠른 셀 탐색을 위한 극성 변조 셀 탐색 알고리즘의 성능 분석)

  • 배성오;임재성
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.8A
    • /
    • pp.598-606
    • /
    • 2003
  • In this paper, we analyze the performance of the PCM cell search algorithm proposed for fast cell search of WCDMA systems. In order to improve both performance and complexity of the cell search algorithm standardized for WCDMA systems the PCM scheme uses a group of the polarization codes produced by a Gold code generator. The PCM scheme only uses one synchronization channel since the polarization codes modulated on P-SCH can replace the RS codes of S-SCH. Thus, the PCM reduces the BS's transmission power since only one synchronization channel can be used, and it can also reduce the complexity of receiver as compared with the conventional one. In this paper, by defining a numerical model, we analyze the performance of the PCM cell search algorithm in terms of detection probability and mean acquisition time. Consequently, we could demonstrate that the PCM cell search algorithm is superior to the standard WCDMA cell search algorithm.

The protective effect of Halal food extract in pancreatic beta cell lines.

  • Kim, Seong-sun;Jin, Yu-Mi;Song, Young-Jae;AYE, AYE;Soh, Ju-Ryoun;Jeon, Yong-Deok;Jin, Jong-Sik
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.04a
    • /
    • pp.121-121
    • /
    • 2019
  • In Islamic dietary guidelines, Halal foods are allowed as edible blessed food. Most foods were categorized within halal for Muslims. The main point of Halal food is that foods are clean in every process and based on Halal standard which might be different in each country. Most pancreatic ${\beta}$ cells synthetize, store, and release insulin. Specific molecular, functional as well as ultrastructural traits of pancreatic ${\beta}$ cells could control their insulin secretion properties and survival phentoype. Insulin-secreting pancreatic ${\beta}$-cells are essential regulators of mammalian metabolism. In addition, the pancreatic ${\beta}$ cell plays an important role in the pathogenesis of type 1 and type 2 diabetes as improving glucose homeostasis by preserving, expanding and improving the function of this key cell type. However, the pharmacological effect of halal food has not been unclear yet, especially food habit-dependent diabetes. The aim of the this study was to determine the preventive effect of Iran plants extract (Almond, Garlic, Cumin, Ginkgo biloba, Holy basil, Psyllium, Satureja khuzistanica, Fenugreek, Green tea, Ipomoea betatas, Blueberry) on RINm5F cells and MIN6 cells as pancreatic ${\beta}$ cell line. The cytotoxicity of the extracts of Iran plants on RINm5F cells and MIN6 cells were measured by using MTT assays. The preventive effects of Iran plant extracts were measured by WST-8 cell proliferation assay on streptozotocin (STZ)-induced cell death in MIN6 cells. In presented result showed that all extract of Iran plants (0.01-10mg/ml) did not show cytotoxicity in RINm5F cells and MIN6 cells. Among non-cytotoxic extract, the protective effects could be detect in high dose concentration. These results suggest that the extract of Iran plants may serve as a potential therapy for diabetes.

  • PDF

A Study of the Long-term Fuel Mix with the Introduction of Renewable Portfolio Standard (RPS(Renewable Portflio Standard) 제도 도입에 따른 국내 장기 전원구성 변화에 관한 연구)

  • Lee, Jeong-In;Han, Seok-Man;Kim, Bal-Ho H.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.3
    • /
    • pp.467-477
    • /
    • 2009
  • Renewable Portfolio Standard (RPS) is a regulatory policy that requires the generation companies to increase the proportion of renewable energy sources such as wind, solar, LFG, fuel cell, and small hydro. Recently, Korean government decided to increase the portion of renewable energy to 3% to total electricity generation by 2012 from the current level of 0.13%. To achieve this goal, an innovative plan for market competitiveness would be required in addition to the present Feed-In-Tariff (FIT). That is Korean government has taken it into consideration to introduce a Renewable Portfolio Standard (RPS) as an alternative to FIT. This paper reviews the impact of RPS on the long-term fuel mix in 2020. The studies have been carried out with the GATE-PRO (Generation And Transmission Expansion PROgram) program, a mixed-integer non-linear program developed by Hongik university and Korea Energy Economics Institute. Detailed studies on long-term fuel mix in Korea have been carried out with four RPS scenarios of 3%, 5%, 10% and 20%. The important findings and comments on the results are given to provide an insight on future regulatory policies.