• Title/Summary/Keyword: standard cell

Search Result 1,439, Processing Time 0.027 seconds

A Study on the Automatic Placement System for Standard Cell (스텐다드 셀의 자동배치 시스템에 관한 연구)

  • Kang, Gil Soon;Kyung, Chong Min;Park, Song Bai
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.23 no.4
    • /
    • pp.557-564
    • /
    • 1986
  • This paper describes a standard cell placement strategy which consists of three kconsecutive steps` initial placement, iterative placement improvement, and string placement. In the initial placement step, cell placement was done by solving the linear ordering problem for a one-dimensional layout of standard cells and then zigzaging the resultant linear order width in the chip plane. The iterative placement improvement step is based on the iterative pairwise interchange using the estimated total routing length as a figure-or -merit. The string placement is used to reorder cells and terminals in each etandard cell row such that channel routing in the adjacent channels is not blocked by cyclic constraints and needs fewer routing tracks. The placement program is coded in PASCAL and kimplemented on a VAX-11/750 computer. Experimental results for several examples are included.

  • PDF

A Comparative Study on Similarity of Flow Fields Reconstructed by VIC# Data Assimilation Method (VIC# 자료동화 기법을 통해 재구축된 유동장의 상사성에 관한 비교 연구)

  • Jeon, Young Jin
    • Journal of the Korean Society of Visualization
    • /
    • v.16 no.2
    • /
    • pp.23-30
    • /
    • 2018
  • The present study compares flow fields reconstructed by data assimilation method with different combinations of parameters. As a data assimilation method, Vortex-in-Cell-sharp (VIC#), which supplements additional constraints and multigrid approximation to Vortex-in-Cell-plus (VIC+), is used to reconstruct flow fields from scattered particle tracks. Two parameters, standard deviation of Gaussian radial basis function (RBF) and grid spacing, are mainly tested using artificial data sets which contain few particle tracks. Consequent flow fields are analyzed in terms of flow structure sizes. It is demonstrated that sizes of the flow structures are proportional to an actual scale of the standard deviation of RBF. It implies that a combination of larger grid spacing and smaller standard deviation which preserves the actual standard deviation is able to save computational resources in case of a low track density. In addition, a simple comparison using an experimental data filled with dense particle tracks is conducted.

Investigation of the ASTM International frost heave testing method using a temperature-controllable cell

  • Hyunwoo, Jin;Jangguen, Lee;Byung-Hyun, Ryu
    • Geomechanics and Engineering
    • /
    • v.31 no.6
    • /
    • pp. 583-597
    • /
    • 2022
  • Frost heave can cause uneven ground uplift that may damage geo-infrastructure. To assist damage-prevention strategies, standard frost heave testing methods and frost susceptibility criteria have been established and used in various countries. ASTM International standard testing method is potentially the most useful standard, as abundant experimental data have been acquired through its use. ASTM International provides detailed recommendations, but the method is expensive and laborious because of the complex testing procedure requiring a freezing chamber. A simple frost heave testing method using a temperature-controllable cell has been proposed to overcome these difficulties, but it has not yet been established whether a temperature-controllable cell can adequately replace the ASTM International recommended apparatus. This paper reviews the applicability of the ASTM International testing method using the temperature-controllable cell. Freezing tests are compared using various soil mixtures with and without delivering blow to depress the freezing point (as recommended by ASTM International), and it is established that delivering blow does not affect heave rate, which is the key parameter in successful characterization of frost susceptibility. As the freezing temperature decreases, the duration of supercooling of pore water shortens or is eliminated; i.e., thermal shock with a sufficiently low freezing temperature can minimize or possibly eliminate supercooling.

The Electromotive Force and Thermodynamic Properties of the Cell at High Pressure (고압하에서의 전지의 기전력과 열역학적 성질)

  • Jee Jong-Gi;Jung Jong-Jae;Hwang Jung-Ui
    • Journal of the Korean Chemical Society
    • /
    • v.18 no.5
    • /
    • pp.320-328
    • /
    • 1974
  • It is unable to derive the standard emf ($E^{\circ}$) of the cell at high pressure from the conventional method. However, when the concept of the complete equilibrium constant($K{\circ})$) is available to the conventional Nernst equation, it is possible to get the standard emf of the cell at high pressure(complete Nernst equation). Moreover, the other thermodynamic properties, such as the net change of solvation number(k), the compressibility of solvent(${\beta}$), ionization constant(K), the standard free energy change(${\Delta}G^{\circ}$), the standard enthalpy change(${\Delta}H^{\circ}$) and the standard entropy change (${\Delta}S^{\circ}$) of the cell reaction at equilibrium state have been also obtained. In this experiment, the emf of the cell; 12.5 % Cd(Hg)│$CdSO_4(3.105{\times}10^{-3}M),\;Hg_2SO_4│Hg$ have bee measured at temperature from 20 to $35^{\circ}C$ and at pressures from 1 to 2500 atms. The emf of the cell increased with increasing pressure at constant temperature, and did with increasing temperature at constant pressure. The net change of solvation number(k) of the cell reaction was 41.96 at $25^{\circ}C$, and kept constant value with pressure, while, K and ${\Delta}S^{\circ}$ increased with pressure, but whereas ${\Delta}G^{\circ}$ and ${\Delta}H^{\circ}$ decreased. Since the standard emf of the cell at high pressure can be calculated from the complete Nernst equation, the theory of chemical equilibrium could be developed with at high pressure as well as at the atmosphere.

  • PDF

A One-Pass Standard Cell Placement Algorithm Using Multi-Stage Graph Model (다단 그래프 모델을 이용한 빠른 표준셀 배치 알고리즘)

  • 조환규;경종민
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.6
    • /
    • pp.1074-1079
    • /
    • 1987
  • We present a fast, constructive algorithm for the automatic placement of standard cells, which consists of two steps. The first step is responsible for cell-row assignment of each cell, and converts the circuit connectivity into a multi-stage graph under to constraint that sum of the cell-widths in each stage of the multi-state graph does not exceed maximum cell-row width. Generatin of feed-through cells in the final layout was shown to be drastically reduced by this step. In the second step, the position of each cell within the row is determined one by one from left to right so that the cost function such as the local channel density is minimized. Our experimental result shows that this algorithm yields near optimal results in terms of the number of feed-through cells and the horizontal tracks, while running about 100 times faster than other iterative procedures such as pairwise interchange and generalized force directed relaxation method.

  • PDF

Fabrication of Multi-crystalline Silicon Solar Cell by using Wafer Adhesion Texturing Method (웨이퍼 접착 텍스쳐링 방식을 이용한 다결정 실리콘 태양전지 제조)

  • Yoon, Seok-Il;Roh, Si-Cheol;Choi, Jeong- Ho;Jung, Jong-Dae;Seo, Hwa-Il
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.4
    • /
    • pp.67-72
    • /
    • 2016
  • In this study, the texturing and the emitter formation processes were carried out with the wafer adhesion method to increase the productivity and reduce the production cost of the multi-crystalline silicon solar cell. After fabricating $156{\times}156mm$ solar cell according to the wafer adhesion method, the operation characteristics were analyzed and compared with those of the solar cell fabricated by the standard process method. In the case of a solar cell formed by the wafer adhesion method, it showed Jsc of $32.87mA/cm^2$, Voc of 0.612V, FF of 78.04% and efficiency of 15.71% respectively. The efficiency of the solar cell formed by the wafer adhesion method was 0.1% higher than that of the solar cell formed by the standard method. In addition, the productivity of the texturing and the emitter formation processes is expected to be approximately doubled. Therefore, it is expected that the manufacturing cost of the multi-crystalline solar cell can be reduced due to the improved productivity compared with the standard process.

A Study on Red Cell Protoporphyrin Concentration and Iron Metabolism (적혈구(赤血球) Protoporphyrin과 철분대사(鐵分代謝)에 관(關)한 연구(硏究))

  • Cho, Kyung-Hwan;Tchai, Bum-Suk
    • Journal of Nutrition and Health
    • /
    • v.7 no.3
    • /
    • pp.1-13
    • /
    • 1974
  • The relative state of human iron storage may be ascertained more reliably through determination of the serum iron, iron binding capacity, transferrin saturation and absorption of radioactive iron in conjunction with studies of red cell morphology than from the study of red cell morphology alone. Recent investigations have shown that there is an increase in red cell protoporphyrin concentration in iron deficiency anemia. The significance of the red cell protoporphyrin has been discussed greatly during the years since its discovery. Two of the main factors which appear to influence the amaunt of protoporphyrin are increased erythropoiesis and factors interfering with the utilization of iron in the synthesis of hemoglobin, and iron deficiency. Recently Heller et al. have described a simplified method for blood protoporphyrin assay and this technique could be used assess nutritional iron status, wherein even minor insufficiencies are detectable as increased protoporphyrin concentrations. Based on the evaluation of the relationship between nutritional iron status and red cell protoporphyrin as an index suitable for the detection of the iron deficiency is described in this paper. RESULTS 1. Hemoglobin Concentrations and Anthropometric Measurements. The mean and standard deviations of the various anthropometric measurements of different age and sex groups are shown in table 1. There measurements have been compared with the Korean Standard. In the absence of local standards for arm circumference and skin-fold thickness over triceps, they have been compared with the standard from Jelliffe. Table 2,3, and 4 give anthropometric measurements and frequency (%) of anemia in children surveyed. The mean height of the children studid was 10 to 20 percent; below the Korean Standard. The distribution of height below 80 percent of the Standard was 21.2 percent, however, among anemic group this percentage was 27.7 percent. In general, the mean weight of the children was 10 to 15 percent below the Korean Standard. The percentage of children with weight less than 80 percent of the Standard was about 35 percent. But in the anemic group of the children, this percentage was 44 percent. The mean arm circumference was about 15 percent lower than the Jelliffe's standard. 61.2 percent of the children had values of arm circumference below 80 percent of the standard. Children with low hemoglobin levels, this percentage was 80 percent. The mean skinfold thickness over the triceps of the children studied was about 25 Percent lower than the Jelliffe's standard and 61.2 percent of the children had the value less than 80 percent of the standard. Among anemic children, this percentage was 70.8%. As may be seen from table 5, the mean hemoglobin concentration of the total group was 11.3g/100ml. Hemoglobin concentration was less than 11.0g/100ml. in 65(36.5%) of the 178 children. The degree of anemia in most of these children was mild with a hemoglobin level of less than 8.0g/100ml. found in only one child. In general, the prevalence of anemia was high in female children than male and decreased its frequency with increasing age. Relatively close relationship was observed between hemoglobin level and anthrophometric measurements especially high between arm circumference and skinfold thickness and hemoglobin but very low in height and low in weight and hemoglobin level, estimated by chi-square value. II. Serum iron, Transferrin saturation (1) Serum iron, and transferrin saturation Serum iron, transferrin saturation and red cell protoporphyrin concentrations were estimated in sub-sample of 84 children from 1 to 6 years and 24 older children between 7 and 13 years of age. The findings are presented in table 6. The mean serum iron concentration of the total group was 59ug/100ml. However, the level incrased with age from 36.6ug/100ml. (1-3years) to 80.8ug/100ml. (7-13 years). 60 percent of these children had a serum iron level less than 50ug/10ml. in the 1-3 years age group and 31.4 percent for 4-6 years group. These contrast with the finding of 12.5 percent anemic children in the 7-13 years age group. The mean transferrin saturation for the total group was 18.1 percent and frequency of anemia by transferrin saturation was observed same pattern as serum iron concentration. (2) Red cell protoporphyrin concentrations. (a) Red cell protoporphrin levels of children: Red cell protoporphyrin and other biochemical data are shown in table 4. The mean concentration in red cell of all children was fround 46.3ug/100ml. RBC. and differences with age groups were observed; in the age group 1-3 years, the mean concentration was $59.5{\pm}32.14$ ug/100ml. RBC; 4-6 years $44.1{\pm}22.57$ ug/100ml. RBC. and 7-13 years, $39.0{\pm}13.56$ ug/100ml. RBC. (b) Normal protoporphyrin values in adults: It was observed that in 10 normal adult males studied here the level of protoporphyrin in red cell ranged from 18 to 54 ug/100ml. RBC. and the mean concentration was $47.5{\sim}14.47$ ug/100ml. RBC. Other biochemical determination made on the same subjects are presented in table 8. (c) Red tell protoporphyrin concentration of occupational blood donors: The results of analyses for red cell protoporphyrin as well as serum iron, transferrin saturation and hemoglobin in the 76 blood donors are presented in table 7 and 8. In this experiment, donors were selected at random, however, most of them bled repeatedly because of poor economic situation, I doubt. Table 9 shows the distribution of red cell protoporphyrin concentration and hemoglobin concentration of occupational donors. The mean hemoglobin value for the total was 11.9 g/100 ml. When iron deficiency anemia is defined as a transferrin saturation below 15%, prevalence of anemia was 47.4 percent and the mean serum iron was 27.1ug/100ml. and red cell protoporphyrin, 168.3ug/100ml. RBC. However, mean serum iron and protoporphyrin concentration of above 15% transferrin saturation were 11.6 ug/100 ml. and 58.8 ug/100 ml. RBC. respectively. The mean Protoporphyrin concentration of non-anemic (above 15% transferrin saturation) donors was slightly higher than the results of normal adult males.

  • PDF

A Study on the Development of Safety Standard through the Risk Assessment for Fuel Cell System Applied to UAV (무인 비행체용 연료전지 시스템 위험요소 분석을 통한 안전기준 개발 연구)

  • TAEHEON KIM;JAEUK CHOI;INROK CHO;JUNGWOON LEE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.35 no.1
    • /
    • pp.56-65
    • /
    • 2024
  • Fuel cell powered unmanned aerial vehicles (UAV) are globally being developed for various application according to hydrogen roadmap. However, safety standards for hydrogen fuel cell for UAV have not been established. Therefore, in this study, we derive safety data based on risk assessment to develop safety standards for fuel cells for UAV. We use fault tree analysis method which is broadly used in hydrogen facilities as a risk assessment tool. We set hydrogen leaks and fires as top events and derived the basic events. Safety data for the basic events were derived by quoting overseas safety standards related to fuel cells. The safety data will be used for developing fuel cell inspection standard according to Act on Hydrogen Economy Promotion and Hydrogen Safety Management.

Assessment of Appropriateness of Standard for Insurance Coverage on Chemotherapy used in Non-small Cell Lung Cancer (NSCLC) (비소세포폐암에 사용되는 항암화학요법의 요양급여기준 적절성 평가)

  • Kim, Jeong-Yeon;Park, Eun-Ji;Bae, Min-Kyung;Yoon, Jeong-Hyun
    • Korean Journal of Clinical Pharmacy
    • /
    • v.21 no.3
    • /
    • pp.193-207
    • /
    • 2011
  • Purpose: The purpose of this study is to assess appropriateness of current standard for insurance coverage by Health Insurance Review & Assessment Service (HIRA) on chemotherapy used in the treatment of advanced non-small cell lung cancer (NSCLC), by reviewing a variety of clinical evidences, and thereby, if needed, to propose an updated evidence-based recommendations. Methods: We collected data from HIRA regarding on the insurance standard which includes the scope and conditions for coverage on systemic chemotherapy of NSCLC. We performed a search for clinical databases and examined the most current clinical evidence from clinical literature including various clinical practice guidelines. Based on the collected data the appropriateness of HIRA standard for insurance coverage of chemotherapy of NSCLC was assessed. Results: Collected data demonstrated that HIRA standard did not reflect the most current clinical practice and evidence. Some were inappropriately listed in HIRA formulary and accepted as a chemotherapy being covered by insurance, despite the lack of evidences of clinical efficacy or superiority over other chemotherapeutic agents or regimens. In addition, there seems to be a need for a modification on the standard for insurance coverage of certain newer chemotherapeutic agents based on the current accumulated data showing their clinical efficacy and benefits in the selected group of NSCLC patients. Therefore, we concluded that current HIRA standard for insurance coverage on chemotherapy of NSCLC needs to be revised and we proposed an updated recommendation based on these latest clinical evidences. Conclusion: The standard for insurance coverage of chemotherapy should be continually examined its appropriateness based on the most recent clinical evidences in a timely manner so as to provide the most effective and safe therapy to cancer patients.

P&R Porting & Test-chip implementation Using Standard Cell Libraries (표준 셀 라이브러리 P&R 포팅과 테스트 칩의 설계)

  • Lim, Ho-Min;Kim, Nam-Sub;Kim, Jin-Sang;Cho, Won-Kyung
    • Journal of Advanced Navigation Technology
    • /
    • v.7 no.2
    • /
    • pp.206-210
    • /
    • 2003
  • In this paper, we design standard cell libraries using the 0.18um deep submircom CMOS process, and port them into a P&R (Placement and Routing) CAD tool. A simple test chip has been designed in order to verify the functionalities of the 0.18um standard cell libraries whose technical process was provided by Anam semiconductor. Through these experiments, we have found that the new 0.18um CMOS process can be successfully applied to automatic digital system design.

  • PDF