• Title/Summary/Keyword: standard cell

Search Result 1,439, Processing Time 0.025 seconds

3- Transistor Cell OTP ROM Array Using Standard CMOS Gate-Oxide Antifuse

  • Kim, Jin-Bong;Lee, Kwy-Ro
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.3 no.4
    • /
    • pp.205-210
    • /
    • 2003
  • A 3-Transistor cell CMOS OTP ROM array using standard CMOS antifuse (AF) based on permanent breakdown of MOSFET gate oxide is proposed, fabricated and characterized. The proposed 3-T OTP cell for ROM array is composed of an nMOS AF, a high voltage (HV) blocking nMOS, and cell access transistor, all compatible with standard CMOS technology. The experimental results show that the proposed structure can be a viable technology option as a high density OTP ROM array for modern digital as well as analog circuits.

Measurement of Solar Cell Using LED-based Differential Spectral Responsivity Comparator under High Background Irradiance

  • Zaid, Ghufron;Park, Seong-Chong;Lee, Dong-Hoon;Park, Seung-Nam
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.293-294
    • /
    • 2009
  • The spectral responsivity of solar cells has been measured under high background irradiance using an LED-based differential spectral responsivity Comparator (DSR-C). The comparator developed is fully automated and has some advantages: It does not need a chopper to modulate the light. Unlike the conventional method, it does not require a monochromator to select wavelength. It covers a wavelength range up to 1200 nm. The wavelength range of the comparator is limited by the spectral power distribution of the LEDs and the spectral responsivity of the standard detector. An active temperature control was utilized to meet the specified standard conditions of solar cell test. This work shows the effect of different levels of background irradiance on the spectral responsivity and the importance of same background irradiance for solar cell test as specified by the corresponding standard.

  • PDF

A channel Routing System using CMOS Standard Cell Library (CMOS 표준 Cell Library를 이용하는 수평 트랙 배선 시스템)

  • 정태성;경종민
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.22 no.1
    • /
    • pp.68-74
    • /
    • 1985
  • In this Paper, we present a non-doglegging channel routing system for If layout using standard cells. This system produces a final two-layer wiring pattern in the horizontal track between two rows, each of which is a linear placement of standard cells of identical heights, satisfying the given net list specification. The layout of CMOS cell library Including nine primitive cells used in this paper is represented in CIF (Caltech Intermediate Form) using λ(Lambda) of 2 microns in Mead-Conway layout representation scheme. The cell dimension and 1/0 characteristics such as name, position and layer type of the pins are stored in Component Library to be used in the channel routing progranl, CROUT. 4 subprogram, NET-PLOT, was used to report a schemdtic layout result, and another subprogram, NETCIF was used to with a full-fledged final layout representation in GIF, A test run for realizing a dynamicmaster-slave D flip-flop with set/reset using primitive cells was shown to take 4 CPU seconds on VAX 11/780.

  • PDF

A $3{\mu}m$ Standard Cell Library Implemented in Single Poly Double Metal CMOS Technology ($3{\mu}m$ 설계 칫수의 이중금속 CMOS 기술을 이용한 표준셀 라이브러리)

  • Park, Jon Hoon;Park, Chun Seon;Kim, Bong Yul;Lee, Moon Key
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.24 no.2
    • /
    • pp.254-259
    • /
    • 1987
  • This paper describes the CMOS standard cell library implemented in double metal single poly gate process with 3\ulcornerm design rule, and its results of testing. This standard cell library contains total 33 cells of random logic gates, flip-flop gates and input/output buffers. All of cell was made to have the equal height of 98\ulcornerm, and width in multiple constant grid of 9 \ulcornerm. For cell data base, the electric characteristics of each cell is investigated and delay is characterized in terms of fanout. As the testing results of Ring Oscillator among the cell library, the average delay time for Inverter is 1.05 (ns), and the delay time due to channel routing metal is 0.65(ps)per unit length.

  • PDF

Design Aspects and Parasitic Effects on Complementary FETs (CFETs) for 3nm Standard Cells and Beyond (3 나노미터와 미래공정을 위한 상호보완 FET 표준셀의 설계와 기생성분에 관한 연구)

  • Song, Taigon
    • Journal of IKEEE
    • /
    • v.24 no.3
    • /
    • pp.845-852
    • /
    • 2020
  • Developing standard cells for 3nm and beyond requires significant advances in the device and interconnect technology. Thus, it is very important to quantify the impact of the new technology in various aspects. In this paper, we perform a through analysis on the impact of Buried Power Rail (BPR) and Complementary FET (CFET) in the perspective of cell area and parasitics such as capacitance. We emphasize that CFET is a technology that realizes 4T and beyond for standard cell designs, but significant capacitance increases (+18.0%), compared to its counterpart technology (FinFET) cell, due to the increase of cell height in the Z-direction.

BIPHASIC CULTURE STRATEGY BASED ON HYPEROSMOTIC PRESSURE FOR IMPROVED HUMANIZED ANTIBODY PRODUCTION IN CHINESE HAMSTER OVARY CELL CULTURE

  • Kim, Min-Su;Kim, No-Su;Seong, Yun-Hui;Lee, Gyun-Min
    • 한국생물공학회:학술대회논문집
    • /
    • 2002.04a
    • /
    • pp.293-296
    • /
    • 2002
  • Hyperosmotic pressure increased specific antibody productivity ($q_{Ab}$) of recombinant CHO cells (SH2-0.32) while it depressed cell growth. Thus, the use of hyperosmolar medium did not increase the maximum antibody concentration substantially. To overcome this drawback, the feasibility of biphasic culture strategy was investigated. In the biphasic culture, cells were first cultivated in the standard medium with physiological osmolality(294 mOsm/kg) for cell growth. When cells reached the late exponential phase of growth, the spent standard medium was replaced with the fresh hyperosmolar medium (522 mOsm/kg) for antibody production. The ($q_{Ab}$) in growth phase with the standard medium was 2.1 ${\mu}g/10^6cell/day$ while the ($q_{Ab}$) in antibody production phase with the hyperosmolar medium (522 mOsm/kg) was 11.1 ${\mu}g/10^6cell/day$. Northern blot analysis showed a positive relationship between the relative contenet of Ig mRNA and ($q_{Ab}$), indicating that transcriptional regulation was involved in the response of rCHO cells to hyperosmotic pressure. Due to the enhanced ($q_{Ab}$) and increased cell concentration in biphasic culture, the maximum antibody concentration obtained in biphasic culture with 522 mOsm/kg medium exchange was 161% higher than that obtained in batch culture with the standard medium. Taken together, simple biphasic culture strategy based on hyperosmotic culture for improved foreign protein production from rCHO cells is effective in improving antibody production of rCHO cells.

  • PDF

A Study on Standard Design Procedure and Optimum Dimension of Embedded Steel-Plate Cell Structure (근입식 강판셀 구조 설계표준화 및 최적제원 결정에 관한 연구)

  • Park, Yong Myung;Kim, Tae Jin
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.3 s.40
    • /
    • pp.259-270
    • /
    • 1999
  • In this study, establishment of standard design procedure and optimum dimension of the embedded steel-plate cellular bulkheads for seawall structures in deep water sites has been presented. A computer program was developed to asses feasible dimensions of steel-plate cell, and general equations to determine optimum cell diameter and embedment depth are derived for sand. A model experiment to verify the necessary driving force of vibratory hammer system was also performed and driving force data pertinent to optimum cell dimension are presented.

  • PDF

Standard Field Generation Using a Micro-TEM Cell and Its Measurement Uncertainty Evaluation (Micro-TEM Cell을 사용한 표준 전자기장의 발생 및 측정불확도 평가)

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Kang, Ung-Taek;Kang, No-Weon;Kang, Tae-Weon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.1
    • /
    • pp.91-99
    • /
    • 2009
  • In this paper, a standard field generation method using a micro-TEM ceil is described and its measurement uncertainty is evaluated. The standard field generation system consists of an auto-leveling signal source, a micro-TEM cell operating up to 1.2 GHz, and a power measuring Instrument using a thermistor mount. Measurement results of a field strength key comparison (CCEM.RF-K20) for the field strength of 20 V/m at frequencies between 10 MHz and 1 GHz are presented for validating the standard field generation method.

A High speed Standard Basis GF(2$^{m}$ ) Multiplier with A Known Primitive Coefficient Set (Standard Basis를 기반으로 하는 유한체내 고속 GF($2^m$) 곱셈기 설계)

  • 최성수;이영규;박민경;김기선
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.333-336
    • /
    • 1999
  • In this paper, a new high speed parallel input and parallel output GF(2$^{m}$ ) multiplier based on standard basis is proposed. The concept of the multiplication in standard basis coordinates gives an easier VLSI implementation than that of the dual basis. This proposed algorithm and method of implementation of the GF(2$^{m}$ ) multiplication are represented by two kinds of basic cells (which are the generalized and fixed basic cell), and the minimum critical path with pipelined operation. In the case of the generalized basic cell, the proposed multiplier is composed of $m^2$ basic cells where each cell has 2 two input AND gates, 2 two input XOR gates, and 2 one bit latches Specifically, we show that the proposed multiplier has smaller complexity than those proposed in 〔5〕.

  • PDF

Quantitative Analysis of Indomethacin by the Portable Near-Infrared (NIR) System (근적외분광분석법을 이용한 인도메타신의 정량분석)

  • 김도형;우영아;김효진
    • YAKHAK HOEJI
    • /
    • v.47 no.5
    • /
    • pp.261-265
    • /
    • 2003
  • Near-infrared (NIR) system was used to determine rapidly and simply indomethacin in buffer solution for a dissolution test of tablets and capsules. Indomethacin standards were prepared ranging from 10 to 50 ppm using the mixture of phosphate buffer (pH 7.2) and water (1 : 4). The near-infrared (NIR) transmittance spectra of indomethacin standard solutions were collected by using a quartz cell in 1 mm and 2 mm pathlength. Partial least square regression (PLSR) was explored to develop calibration models over the spectral range 1100∼1700 nm. The model using 1 mm quartz cell was better than that using 2 mm quartz cell. The PLSR models developed gave standard error of prediction (SEP) of 0.858 ppm. In order to validate the developed calibration model, routine analysis was performed using another standard solutions. The NIR routine analysis showed good correlation with actual values. Standard error of prediction (SEP) is 1.414 ppm for 7 indomethacin samples in routine analysis and its error was permeable in the regulation of Korean Pharmacopoeia (VII). These results show the potential use of the real time monitoring for indomethacin during a dissolution test.