• Title/Summary/Keyword: standard Korean

Search Result 34,727, Processing Time 0.062 seconds

Selection of Representative Menu and Development of Standard Recipes in Middle & High School Meals (중.고등학교 급식의 대표메뉴 선정 및 표준조리법 개발)

  • Lee, Seon-Mi;Jeong, Hyeon-A;Park, Sang-Hyeon;Ju, Na-Mi
    • Journal of the Korean Dietetic Association
    • /
    • v.11 no.1
    • /
    • pp.28-43
    • /
    • 2005
  • This study was conducted to illustrate standard menu items available in the school foodservice industry, and to establish higher nutritional standards in this industry. We reviewed menu items from 125 middle and high schools from the Seoul area for three months. These menus were then classified into 12 representative menu items, as follows: beef seeweed soup, egg soup, sliced rice rod soup, spaghetti, sauted squid with hot sauce, fish cutlet, simmered pork-egg in soy sauce, sweet and sour meat, sauted pork, acorn starch jelly salad, cucumber salad. And standard recipes of these 12 representative menu items were established, based on a survey from 150 dietitians who completed a questionnaire of 97 questions. According to the survey results, 89% of the dietitians answered positively('yes') about the necessity of establishing standard recipes for the school foodservice industry. 69% of the dietitians were educated standard recipes for the school foodservice, 91% will use standard recipes for the school foodservice Moreover, we discovered there was a consensus on what type of menu items should be included on the menus; demographic factors only affected a small range of recommended items. In order to confirm real application of resulted standard recipe, it is required to conduct quantity food production at real foodservice and study on more suitable standard recipe.

  • PDF

Precision Control of a Torque Standard Machine Using Fuzzy Controller (퍼지제어기를 이용한 토크 표준기의 정밀제어)

  • Kim, Gab-Soon;Kang, Dae-Im
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.7
    • /
    • pp.46-52
    • /
    • 2001
  • This study describes the precision control of the torque standard machine using a self-tuning fuzzy controller. The torque standard machine should generate the accurate torque for calibrating a torque sensor. In order to reduce the relative expanded uncertainty of the torque standard machine, when a weight is hanged to the end of the torque arm for generating the torque, the sloped torque arm should be accurately controlled to the horizontal level. If the slope of the torque arm is larger from the inaccurate control, the uncertainty of the torque standard machine due to control will be larger. This applies the inaccurate torque to a torque sensor to calibrate, and the measuring error of the torque sensor generate from it. Therefore the torque arm of the torque standard machine is accurately controlled. In this paper, the self-tuning fuzzy controller was designed using a fuzzy theory, and the torque arm of the torque standard machine was accurately controlled. The control gain of the fuzzy controller, that is the membership function size of the error, the membership function size of the error change and the membership function size of the controller were determined from the self-tuning. The control results of the torque standard machine were the overshoot within 0.0076mm, the rise time within 16.70sec and the steady state error within 0.0076mm.

  • PDF

A STUDY ON THE DEVELOPMENT OF STANDARD CRITERIA OF EQUIPMENT FOR 3 YEAR NURSING EDUCATION (3년제 간호교육과정의 실험실습 기자재 기준 개발)

  • Chon, Si-Ja;Kwon, Sook-Hee;Kim, Yeon-Hwa;Park, Yeon-Su;Hong, Yong-Hae;In, Kyung-Sun;Lee, Sook-Hee;Oh, Sei-Young;Choi, Byung-Sun;Chu, Su-Kyung
    • The Korean Nurse
    • /
    • v.37 no.3
    • /
    • pp.78-91
    • /
    • 1998
  • This descriptive study was conducted in order to develop a standard criteria for nursing laboratory facilities and equipment for use by the 3 year nursing colleges. The data was collected from Aug. 28 to Sept. 30, 1997 by mail from 44 3 year nursing schools. To develop a standard criteria, the syllabi for Fundamentals of Nursing laboratory and for Physical Assessment were collected and analyzed. The following information was elicited and analyzed by the researchers : 1. for each procedure in the syllabus, the percentage of schools using the procedures 2. the facilities and equipment recognized as necessary and the percentage of schools which possess each item 3. calculation of the standard criteria for size of the nursing laboratory together with a list of the necessary facilities and equipment. The results of the study were as follows : 1. The Size of facility was 181.2m2 for fundamentals of Nursing laboratory and 56.4m2 for the storage room. For those whose number of students exceed 120, 1.98m2 is required for each students. 2. The number of items included in the standard criteria was 92 for Fundamentals of Nursing and Physical Assessment and 47 for other nursing subjects. The items made of rubber, plastic and the disposable ones were suggested but excluded from the standard criteria. Based on the above findings, the following suggestions were made : 1. Periodic review of the standard criteria is necessary to update the standard. 2. A study on the standardization of the curriculum for basic science laboratory, including experiment and a standard criteria of equipment, is necessary. 3. A study to develop a computer program for management of nursing laboratory facilities and equipment is needed.

  • PDF

CCD PHOTOMETRY OF STANDARD STARS AT MAIDANAK ASTRONOMICAL OBSERVATORY IN UZBEKSTAN: TRANSFORMATIONS AND COMPARISONS

  • Lim, Beomdu;Sung, Hwan-Kyung;Bessell, M.S.;Karimov, R.;Ibrahimov, M.
    • Journal of The Korean Astronomical Society
    • /
    • v.42 no.6
    • /
    • pp.161-174
    • /
    • 2009
  • Observation of standard stars is of crucial importance in stellar photometry. We have studied the standard transformation relations of the UBV RI CCD photometric system at the Maidanak Astronomical Observatory in Uzbekistan. All observations were made with the AZT-22 1.5m telescope, SITe 2k CCD or Fairchild 486 CCD, and standard Bessell UBV RI filters from 2003 August to 2007 September. We observed many standard stars around the celestial equator observed by SAAO astronomers. The atmospheric extinction coefficients, photometric zero points, and time variation of photometric zero points of each night were determined. Secondary extinction coefficients and photometric zero points were very stable, while primary extinction coefficients showed a distinct seasonal variation. We also determined the transformation coefficients for each filter. For B, V, R, and I filters, the transformation to the SAAO standard system could be achieved with a straight line or a combination of two straight lines. However, in the case of the U filter and Fairchild 486 CCD combination, a significant non-linear correction term - related to the size of Balmer jump or the strength of the Balmer lines - of up to 0:08 mags was required. We found that our data matched well the SAAO photometry in V, B - V, V - I, and R - I. But in U - B, the difference in zero point was about 3.6 mmag and the scatter was about 0.02 mag. We attribute the relatively large scatter in U -B to the larger error in U of the SAAO photometry. We confirm the mostly small differences between the SAAO standard UBV RI system and the Landolt standard system. We also attempted to interpret the seasonal variation of the atmospheric extinction coefficients in the context of scattering sources in the earth's atmosphere.

An Estimation of the Standard Cost of Project Management of Empowerment Sector in Comprehensive Rural Village Development Project (일반농산어촌개발 지역역량강화사업비의 적정요율 산정)

  • Choi, Young-Wan;Park, Hyun-Yong;Kim, Young-Joo
    • Journal of Korean Society of Rural Planning
    • /
    • v.19 no.3
    • /
    • pp.131-144
    • /
    • 2013
  • The existing standard cost of project management of empowerment sector in general rural development project has problems with standard cost system without considering characteristics of empowerment project and unclear division of works. These problems are a lot of trouble to fulfill the project. Thus, it needs an arrangement of standard cost considering detailed characteristics of project management in the empowerment sector. The contents and results of this study can be summarized as follows. 1) To set accurate standard cost, we carried out three-step processes, such as elicitation of standard works, calculation of workload and determination of standard cost. (1) In an investigation of 30 rural area dividing 8 parts about an workload of empowerment project, an average workload is 1,499 hours. (2) Based on this results, the standard cost is calculated at 15% of project cost in over 600 million won, at 28.75% of project cost in under 500 million won, by standards of empowerment project cost. 2) It set the responsibility management cost to 15% of empowerment project cost considering existing awareness, workload and work professionalism of project management. Based on the results, It suggested the practical use as basis for efficient management of the future empowerment projects. To achieve this, It needs to promote maximizing results on the whole project through the legalization processes including amendment of existing regulations.

A Study on the Management Criteria of Chemiclas Impurities for Drinking Water Treatment by Risk Assessment (건강위해성 평가에 의한 정수용 수처리제의 불순물 관리 기준 설정 방법에 관한 연구)

  • Chung, Yong;Beck, Young-seog;Kwon, Dong-sik;Lee, Ki-gong;Kang, Hyeong-seok
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.5
    • /
    • pp.432-436
    • /
    • 2004
  • The principle and methodology of risk assessment was applied to establish the quality standard of potential impurities of drinking water treatment chemicals. The impurities(arsenic, lead, cadmium, chromium, mercury, etc.) are regulated as the contained quantity of chemicals in Korea while they are regulated as the quality standard with the idea of 10% of the national safety drinking water standard in U.S.A(NSF) and Japan(JWWA). According to risk assessment of the current standard implemented in Korea, the excess cancer risk of arsenic and lead were determined in around $10^{-5}$ and the hazard quotient(HQ) of cadmium and chromium were below $10^{-2}$, respectively. And the standard concentration of the impurities are regulated as much as 2%~6% of the national drinking water quality standard. The values are more enforced rather than the standards in U.S.A(NSF) and Japan(JWWA) regulating the concentration of impurities the 10% of the national drinking water quality standard. We conclude that the impurities standard of drinking water treatment chemicals should be reconsidered comprehensively concerning the national safety drinking water quality standard and risk assessment.

A W-Band Millimeter-Wave Power Standard Transfer System Using the Direct Comparison Method (직접 비교법을 이용한 W-Band 밀리미터파 전력 표준 전달 시스템)

  • Kwon, Jae-Yong;Kang, Tae-Weon;Kang, Jin-Seob;Lee, Dong-Joon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.1
    • /
    • pp.47-54
    • /
    • 2013
  • This paper introduces a W-band millimeter-wave power standard transfer system using the direct comparison method. The transfer system was developed to evaluate the effective efficiency and calibration factor of a W-band waveguide power sensor. The evaluation method and the measured results of the directional coupler that characterizes the calibration system are studied. The uncertainties of the standard transfer system are investigated, and the major uncertainty contributors are discussed as well. The performance of the realized W-band power standard transfer system was verified by comparing results with reference values.

The Characteristices of Step Responses of the Manabe Standard Forms and Its Application to the Controller Desegn (Manabe 표준형의 계단 응답 특성 및 제어기설계에의 응용)

  • Gang, Hwan-Il
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.5
    • /
    • pp.586-592
    • /
    • 1999
  • We investigate the characteristic of 소데 responses of the Manabe standard form which is used recently for design of the controller. We obtain some theorems and these theorems have the properties of the relationship between the roots of the polynomial and the stability indices which are used for the Manabe standard form. The Manabe standard form has the following properties: The sum of the squal to zero, the sum of the reciprocal of the squared roots is greater than zero and the parameter $\tau$ is the negative value of the sum of the reciprocal of the roots. We compare the step responses of the Manabe standard form with those of the ITAE form, the dead beat response and Bessel forms. We choose the 6th order closed loop polynomial and keep the same settling time for the four forms. Under these conditions we find that the Manabe standard form have faster 90% rising time than the Bessel and dead beat response. We see that the ITAE, bessel and dead beat responses have some overshoot, whereas the Manabe standard form has none. We also compare the Manabe form with the other three forms for the controller design using the pole assignment technique. If the open loop transfer function is a type-1 system (transfer functions having one integrator), then, for the closed loop system associated with the open loop transfer function, the steady state error of the unit ramp input is obtained in terms of the parameter $\tau$ of the Manabe standard form.

  • PDF

The Accuracy of the Radiographic Method in Root Canal Length Measurement (근광장 측정에서 방사선 사진술의 정확도)

  • Jo Eun-Young;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.28 no.2
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF