• Title/Summary/Keyword: stage loading factor

Search Result 49, Processing Time 0.023 seconds

Effects of Failure Mode II on Crack Initiation and Crack propagation Steps Using Multilevel Fatigue Loading Test (다단계 피로하중 실험을 통한 균열 발생 및 전파단계에서 파괴모드 II 영향 분석)

  • Hong, Seok Pyo;Park, Sae Min;Kim, Ju Hee
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.9
    • /
    • pp.853-860
    • /
    • 2017
  • To evaluate the effects of mode II on the crack initiation and propagation stages, the effects in the fatigue threshold region under a mixed-mode I+II loading state was experimentally investigated. In the case of mixed-mode I + II, during the crack initiation stage, as the loading application angle (${\theta}$) increased, cracks occurred in the lower load owing to the effects of mode II, while the crack propagation rate decreased. The effects of mode II were experimentally investigated in the crack propagation stage by means of multilevel loading direction variation. Following mixed-mode I+II ($0^{\circ}{\rightarrow}{\theta}{\rightarrow}60^{\circ}$), as the load application angle increased, the fatigue crack propagation rate decreased, as did the fatigue crack propagation rate, which occurred later. Following mixed-mode I + II in case of(${\theta}{\geq}75^{\circ}$), the fatigue crack propagation rate was found to increase, while the fatigue life decreased.

Design and Prediction of Three Dimensional Flows in a Low Speed Highly Loaded Axial Flow Fan

  • Liu, Xuejiao;Chen, Liu;Dai, Ren;Yang, Ailing
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.2
    • /
    • pp.94-104
    • /
    • 2013
  • This paper describes the design to increase the blade loading factor of a low speed axial flow fan from normal 0.42 to highly loaded 0.55. A three-dimensional viscous solver is used to model the flows in the highly-loaded and normal loaded stages over its operation range. At the design point operation the static pressure rise can be increased by 20 percent with a deficit of efficiency by 0.3 percent. In the highly loaded fan stage, the rotor hub flow stalls, and separation vortex extends over the rotor hub region. The backflow, which occurs along the stator hub-suction surface, changes the exit flow from the prescribed axial direction. Results in this paper confirm that the limitation of the two dimensional diffusion does not affect primarily on the fan's performance. Highly loaded fan may have actually better performance than its two dimensional design. Three dimensional designing approaches may lead to better highly loaded fan with controlled rotor hub stall.

Post-earthquake capacity evaluation of R/C buildings based on pseudo-dynamic tests

  • Kang, Dae-Eon;Yi, Waon-Ho
    • Structural Engineering and Mechanics
    • /
    • v.24 no.1
    • /
    • pp.91-105
    • /
    • 2006
  • In this paper, post-earthquake capacity evaluation method of reinforced concrete buildings was studied. Substructure pseudo-dynamic test and static loading test of first story column in a four-story R/C building was carried out in order to investigate the validity of the evaluation method proposed in the Damage Assessment Guideline (JBDPA 2001). In pseudo-dynamic test, different levels of damage were induced in the specimens by pre-loading, and input levels of seismic motion, at which the specimens reached to the ultimate stage, were examined. From the experimental result, no significant difference in damage levels such as residual crack width between the specimens under static and pseudo-dynamic loading was found. It is shown that the seismic capacity reduction factors ${\eta}$ can provide a reasonable estimation of post-earthquake seismic capacity of R/C buildings suffered earthquakes.

Control of Asymmetrical Tall Buildings under Wind Loading (비대칭 고층건물의 내풍 및 제진 해석)

  • 민경원;김진구;조한욱
    • Computational Structural Engineering
    • /
    • v.10 no.2
    • /
    • pp.203-211
    • /
    • 1997
  • In the design of tall building system, the wind loading can be more dominant factor than earthquake loading, and thus, it is important to check the stability and human comfort against wind. Experimental wind tunnel test is usually performed to predict wind behavior of a tall building, however, the test is not cost-effective in the preliminary stage for various structural models of tall building systems. In this regard, the study is focused on the numerical wind analysis of the tall building with and without tuned mass dampers based on the three dimensional model of wind loads and building behavior. As a numerical result, an asymmetrical 102-story tall building is presented to show the results of root mean squares of build responses with and without tuned mass dampers.

  • PDF

A Study on the Power Supply for Endura Electrodeless Lamp (엔두라 무전극 램프용 전원장치 연구)

  • 한수빈;박석인;정봉만;김규덕;이선근
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.15-18
    • /
    • 2002
  • Power supply technique for electrodeless lamps, especially Endura of Osram, is presented in this paper. The power supply uses a conventional power factor correction technique due to its proved performance. But in the inverter stage, resonant converter with parallel loading scheme is used to mitigate the variation of matching circuit characteristics by time varying load. Less performance but sufficient to predict future success compared to Osram's one is verified as a result of experiment of the prototype.

  • PDF

A Study on the Power Supply for Electrodeless Lamp (무전극 형광등용 전원)

  • Han, Soo-Bin;Jang, Woo-Jin
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.13-16
    • /
    • 2004
  • Power supply technique for electrodeless lamps is presented in this paper. The power supply uses a conventional power factor correction technique due to its proved performance. But in the inverter stage, resonant converter with parallel loading scheme is used to mitigate the variation of matching circuit characteristics by time varying load. Experiment and performance comparison for both Endura md QL are performed and further study to commercialization are discussed.

  • PDF

A Study on Fatigue Crack Growth Model Considering High Mean Loading Effects Based on Structural Stress (고평균하중을 고려한 구조응력 기반의 피로균열성장 모델에 관한 연구)

  • Kim, Jong-Sung;Kim, Cheol;Jin, Tae-Eun;Dong, P.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.220-225
    • /
    • 2004
  • The mesh-insensitive structural stress procedure by Dong is modified to apply to the welded joints with local thickness variation and inignorable shear/normal stresses along local discontinuity surface. In order to make use of the structural stress based K solution for fatigue correlation of welded joints, a proper crack growth model needs to be developed. There exist some significant discrepancies in inferring the slope or crack growth exponent in the conventional Paris law regime. Two-stage crack growth model was not considered since its applications are focused upon the fatigue behavior in welded joints in which the load ratio effects are considered negligible. In this paper, a two-stage crack growth law considering high mean loading is proposed and proven to be effective in unifying the so-called anomalous short crack growth data.

  • PDF

Topology and geometry optimization of different types of domes using ECBO

  • Kaveh, A.;Rezaei, M.
    • Advances in Computational Design
    • /
    • v.1 no.1
    • /
    • pp.1-25
    • /
    • 2016
  • Domes are architectural and elegant structures which cover a vast area with no interrupting columns in the middle, and with suitable shapes can be also economical. Domes are built in a wide variety of forms and specialized terms are available to describe them. According to their form, domes are given special names such as network, lamella, Schwedler, ribbed, and geodesic domes. In this paper, an optimum topology design algorithm is performed using the enhanced colliding bodies optimization (ECBO) method. The network, lamella, ribbed and Schwedler domes are studied to determine the optimum number of rings, the optimum height of crown and tubular sections of these domes. The minimum volume of each dome is taken as the objective function. A simple procedure is defined to determine the dome structures configurations. This procedure includes calculating the joint coordinates and element constructions. The design constraints are implemented according to the provision of LRFD-AISC (Load and Resistance Factor Design-American Institute of Steel Constitution). The wind loading act on domes according to ASCE 7-05 (American Society of Civil Engineers). This paper will explore the efficiency of various type of domes and compare them at the first stage to investigate the performance of these domes under different kind of loading. At the second stage the wind load on optimum design of domes are investigated for Schwedler dome. Optimization process is performed via ECBO algorithm to demonstrate the effectiveness and robustness of the ECBO in creating optimal design for domes.

Development of A Nurse는s Suffering Experience Scale (말기 암 환자를 간호하는 간호사의 고통경험 척도개발)

  • 조계화
    • Journal of Korean Academy of Nursing
    • /
    • v.32 no.2
    • /
    • pp.243-253
    • /
    • 2002
  • The purpose of this study was to develop Nurse's Suffering Experience Scale and to test the reliability and validity of the instrument. Method: The subjects used to verify the scale's reliability and validity were 220 nurses who were taking care of the end stage cancer patients, while working at university and general hospitals in Daegu and Kyungbuk province from April 20. to July 10, 2001. The data was analyzed by the SPSS/WIN 8.0 program. Results: A factor analysis was conducted, and items that had a factor loading more than .40, and an eigen value more than 1.0. were selected. The factor analysis classified a total of seven factors statistically, and it's communality was 44%. The explanation of factors based on the conceptual framework and item content are as follows: The first factor was expanding self consciousness, the second factor was forming empathy with family, the third factor was professional challenge, the fourth factor was change of values, the fifth factor was spiritual sublimation, the sixth factor was helplessness, and finally the seventh factor was rejection to death. Cronbach's coefficient to test reliability of the scale was .8665 for total of 44 items. The Scale for Nurse's Suffering Experience developed in the study was identified as a tool with a high degree of reliability and validity. Therefore this scale can be effectively utilized for the evaluation of the degree of nurse's suffering experience in clinical settings.

Multiaxial ratcheting behavior of Inconel 718 at elevated temperature (Inconel 718 의 고온 다축피로하중 하에서의 라체팅 거동)

  • Kim, Hyo-Shin;Kim, Kwang-Soo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.344-349
    • /
    • 2008
  • Ratcheting behavior of IN 718 was investigated at $649^{\circ}C$ under various proportional and non-proportional loading conditions with stress control. The material response was initially elastic but substantial plastic strain was developed as the material softened cyclically. Ratcheting strain was measured to near fatigue life, and is found to have three stages of development - primary, secondary (steady-state) and tertiary. The secondary stage dominates for most cases. Under the same equivalent stress amplitude and mean stress, it was revealed that circular path loading gives higher ratcheting rates and shorter lives than linear paths and that the more ratcheting occurs when the cyclic load is in the same direction as the mean stress. The ratcheting strain at failure depends not only on its rate but also on fatigue life itself, and it is not a primary life-determining factor.

  • PDF