• 제목/요약/키워드: stack performance

검색결과 624건 처리시간 0.026초

AMESet 기반 20 kW급 수소 연료전지 시스템 동특성 모델 해석 (Analysis of Dynamic Characteristics of 20 kW Hydrogen Fuel Cell System Based on AMESet)

  • 우종빈;김영현;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제34권5호
    • /
    • pp.465-477
    • /
    • 2023
  • In proton exchange membrane fuel cell (PEMFC), proper thermal management of the stack and moisture generation by electrochemical reactions significantly affect fuel cell performance. In this study, the PEMFC dynamic characteristic model was developed through Simcenter AMESim, a development program. In addition, the developed model aims to understand the thermal resin balance of the stack and performance characteristics for input loads. The developed model applies the thermal management model of the stack and the moisture content and permeability model to simulate voltage loss and stack thermal behavior precisely. This study extended the C based AMESet (adaptive modeling environment submodeling tool) to simulate electrochemical reactions inside the stack. Fuel cell model of AMESet was liberalized with AMESim and then integrated with the balance of plant (BOP) model and analyzed. And It is intended to be used in component design through BOP analysis. The resistance loss of the stack and thermal behavior characteristics were predicted, and the impact of stack performance and efficiency was evaluated.

5 kW 용융탄산염 연료전지 스택내 운전특성 및 온도 변화 해석 (Operation Characteristics and Analysis of Temperature Gradients in a 5-kW Molten Carbonate Fuel Cell Stack)

  • 임희천;고준호;류정인
    • 한국수소및신에너지학회논문집
    • /
    • 제10권2호
    • /
    • pp.107-118
    • /
    • 1999
  • MCFC 발전 기술의 실용화를 위하여 $3,000cm^2$ 면적의 단위전지 20장으로 구성된 5 kW 급 MCFC 스택을 5,760 시간 동안 운전하여 그 운전특성을 파악하였다. 스택은 7.6 kW의 출력을 보여주어 설계치보다 높은 출력을 보여주었다. 아울러 스택 성능 및 스택내 운전온도 분포변화를 해석하기 위하여 열전달, 유동방정식 및 연료전지 반응특성을 고려한 수학적 모델을 완성하였다. 완성된 수학적 모델 전산 모사를 위하여 상용 CFD 코드를 이용한 프로그램을 개발하였고 개발된 스택 전산모사 코드는 실제 운전된 5 kW MCFC 스택 운전 자료와 이론적 계산결과와 비교하여 그 신뢰성을 확인하였다.

  • PDF

왕복유동을 이용한 확산증대 효과에 대한 연구 (Enhanced diffusion by using pulsating flow)

  • 황용신;이대영;김서영;최훈;차석원
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.538-541
    • /
    • 2008
  • This study considers the feasibility of the concentration control of the feul and air by oscillating flow in the channel of Fuel Cells. Fuel Cell Stack performance is largely influenced by the fuel and air concentration. If the fuel and air concentration is lower than stoichiometry 1.25 of the fuel and 2.5 of the air, its performance deteriorates seriously because of the fuel and air starvation. In this respect the optimization of the fuel and air concentration is crucially important to maximize fuel cell stack performance. In this work, the effects of oscillating actuation are studied to control the concentration. Two important nondimensional parameters are introduced, each of which represents either the oscillating frequency or the oscillating amplitude. It is shown how these factors affect the stack performance and the efficiency of the fuel cell stack stack.

  • PDF

재생전원 시스템의 지상 시뮬레이터용 1kW급 재생형 연료전지 개발 (Development of the 1kW Class Regenerative Fuel Cell for Ground Simulator of Regeneration Electric Power System)

  • 김형모;양철남;홍병선;박영일
    • 대한기계학회논문집B
    • /
    • 제30권11호
    • /
    • pp.1117-1122
    • /
    • 2006
  • The PEM type regenerative fuel cell(RFC) for the ground simulator of the regeneration electric power system has been designed, manufactured, and tested. In this paper, the designing and manufacturing procedures of the RFC were presented. Also, the performance test results were showed briefly. The RFC consists of PEM type stack, humidifier, pressure and flow control valve, storage tanks, pump and controller. The performance tests were carried out with stack and system performance tests. The performance targets are more than 50% stack efficiency, 1.5kW stack power, less 400W parasitic power in design condition. Most of the performances required are satisfied.

건물용 고체산화물연료전지 스택 안전성능평가 연구 (Study on safety performance evaluation of stationary SOFC stack)

  • 박태성;이은경;이승국
    • 에너지공학
    • /
    • 제27권4호
    • /
    • pp.1-12
    • /
    • 2018
  • SOFC (Solid Oxide Fuel Cell) stack 안전성능 평가항목 및 평가절차 도출을 위하여 국내 외 연료전지 관련 규격들을 분석하였으며, 분석을 통해 도출된 시험항목으로 SOFC stack 안전성능 시험을 실시하였다. 시험에 사용된 SOFC stack은 (주)미코사(社)에서 제작된 음극 지지형 2 cell stack(활성면적: $110.25cm^2/cell$)이고, 평가장치는 자체 제작한 SOFC stack 안전성능 평가 장치를 사용하였다. 기밀성능 시험, 전류전압특성 시험, 정격출력 시험 및 부하변동 시험을 실시하였으며, 그 결과 해당 stack의 최대출력은 65.6 W(1.41 V, 46.5 A, $422mA/cm^2$), 정격출력은 62.3 W(1.57 V, 40 A, $363mA/cm^2$)로 나타났으며 가스누출이 없음을 확인하였다. 또한, 부하변동에 대하여 2초 이내에 안정적으로 출력이 유지되는 것을 확인하였다. 이때 운전 온도 $750^{\circ}C$에서 최대부하(40 A) 및 최소부하(8 A)에서의 출력은 각 62 W와 16 W로 측정되었다. 본 연구를 통하여 고체산화물연료전지의 보급화와 안전한 사용 환경을 제공하는데 기여하고자 한다.

소형 모듈 스택을 이용한 가정용 연료전지 성능의 실험적 고찰 (An Experimental Study of Short Stack on the Performance of the Proton Exchange Membrane Fuel Cell for the Residential Power generation)

  • 최원석;김용모;유상석;이영덕;홍동진;안국영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.21-24
    • /
    • 2008
  • Proton Exchange Membrane Fuel Cell (PEMFC) is an attractive candidate for residential power generator due to fast start-up and stop, high efficiency, low emission, and high power density. In this study, we employ short module stack to understand the performance of the unit cell of the stack in terms of operating temperatures. To simulate the practical fuel cell stack of residential power generator, the structure and active area of the short module stack is kept the same as that of the practical fuel cell. The results shows that the electric potential of short module stack is different from the number of cells times the potential of unit cell because of cell-to-cell variation.

  • PDF

인산형 연료전지 30W급 스택제조 및 발전실험 (Fabrication of 30W PAFC stack and its electrical performance)

  • 김창수;송락현;최병우;한성옥;최수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.78-80
    • /
    • 1991
  • Preliminary multiple cell stack testing was performed using three-cell stack each electrode having an active area of $100cm^2$. The stack was operated at $190^{\circ}C$, the output power was 32W at 1.8V and maximum power was 69W. It was recorded as the first stack fabricated in Korea and continuous research works on the fabrication of stack, optimization of stack performance and long run tests will be conducted.

  • PDF

고효율 가압형 고분자전해질 연료전지 셀스택 개발 (Development of a High Efficiency Polymer Electrolyte Membrane Fuel Cell Stack under Pressurized Operating Conditions)

  • 한인수;서하규;정지훈;김민성;신현길;허택욱;조성백
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.125.1-125.1
    • /
    • 2010
  • A high efficiency polymer electrolyte membrane (PEM) fuel cell stack was developed for pressurized pure hydrogen and oxygen supplying conditions. The design objective for the cell stack was to maximize the electric efficiency and to minimize exhaust-gas emissions from it simultaneously. To achieve this objective, the cell stack was designed to use pure hydrogen and oxygen as fuel and oxidant, respectively, and to be operated under high gas inlet pressures and in a stage-wise dead-end operation mode. Major components constituting the cell stack, such as membrane electrode assembly, bipolar-plate, and gasket, have been developed to meet a target durability even in severe operating conditions: high gas inlet pressures and usage of pure oxygen. A high-power fuel cell stack was assembled using these components to verify the performance. The cell stack showed a good performance in terms of the efficiency and maximum power output.

  • PDF

이산화탄소 에어컨 시스템을 이용한 연료전지 자동차의 스택 냉각성능에 대한 실험적 연구 (Experimental Studies on the Stack Cooling Performance Using a $CO_2$ Air Conditioning System in Fuel Cell Vehicles)

  • 김성철;김민수;원종필
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.87-93
    • /
    • 2008
  • The $CO_2$ air conditioning system installed in fuel cell vehicles could be used either for stack cooling or for cabin cooling, and thus was used for the stack cooling when additional stack heat release was required over a fixed radiator capacity for high power generation. This study investigated the performance of the stack cooling system using $CO_2$ air conditioner at various operating conditions. Also, the heat releasing effectiveness and mutual interference were analyzed for the stack cooling system using an air conditioner and compared with the conventional radiator cooling system with/without cabin cooling. The heat release of the stack cooling system with the aid of $CO_2$ air conditioner increased up to 36% more than that of the conventional radiator cooling system with cabin cooling. Furthermore, the heat release of the stack cooling system using $CO_2$ air conditioner increased more by 7% than that of the conventional radiator cooling system without cabin cooling.

고온 고분자전해질 연료전지 박판형 분리판의 유로 설계 및 스택 성능 평가 (Flow Field Design and Stack Performance Evaluation of the Thin Plate Separator for High Temperature Polymer Electrolyte Membrane Fuel Cell)

  • 김지홍;김민진;김진수
    • 한국수소및신에너지학회논문집
    • /
    • 제29권5호
    • /
    • pp.442-449
    • /
    • 2018
  • Research on High temperature polymer electrolyte fuel cell (HT-PEMFC) has actively been conducted all over the world. Since the HT-PEMFC can be operated at a high temperature of $120-180^{\circ}C$ using phosphoric acid-doped polybenzimidazole (PBI) electrolyte membrane, it has considerable advantages over conventional PEMFC in terms of operating conditions and system efficiency. However, If the thermal distribution is not uniform in the stack unit, degradation due to local reaction and deterioration of lifetime are difficult to prevent. The thin plate separator reduces the volume of the fuel cell stack and improves heat transfer, consequently, enhancing the cooling effect. In this paper, a large area flow field of thin plate separator for HT-PEMFC is designed and sub-stack is fabricated. We have studied stack performance evaluation under various operating conditions and it has been verified that the proposed design can achieve acceptable stack performance at a wide operating range.