• 제목/요약/키워드: stack

검색결과 2,229건 처리시간 0.027초

연료전지 자동차 열방출 시스템의 설계 (Design of a Heat Release System for Fuel Cell Vehicles)

  • 김민수;김성철;박민수;정승훈;윤석호
    • 신재생에너지
    • /
    • 제1권4호
    • /
    • pp.49-54
    • /
    • 2005
  • There is close relation between the heat generation in the fuel cell stack and the fuel performance. In PEM fuel cell vehicles, the stack coolant temperature is about $65^{\circ}C$, which is far lower than that for general automobile engine. Therefore, it is hard to release heat generated in the stack by using a radiator of limited size because of the reduced temperature difference between the coolant and the ambient air. In this study, indirect stack cooling system using $CO_2$ heat pump was designed and its stack cooling performance in releasing heat to the ambient was investigated. This work focuses on a series of processes that grasp the relation among the fuel cell power, the radiator capacity and the stack temperature. The purpose of this work is to find out a way to properly release sufficient amount of heat through the finite sized radiator, so that the slack power generation can not be deteriorated due to the stack temperature increase. The optimization between the compressor power consumption and the fuel cell output power can be carried out to maximize the performance of fuel cell system.

  • PDF

고분자 연료전지의 데드엔드 운전 시 기울임에 따른 성능 변화 (The Effects of the Inclination on the Performance of dead-end operating PEM Fuel Cell)

  • 정지훈;고백균;한인수;신현길;허태욱;조성백
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.89.2-89.2
    • /
    • 2011
  • In automotive applicatons or water vehicles, the polymer electrolyte membrane fuel cell(PEMFC) stack is keep moving while their operation. Especially the inclination environment can take a effect to fuel cell stack perfromance, because this condition can cause a bad effect to water exhaust of fuel cell stack. In this study, a large scale stack(over 100kW power) is inclined upto 30 degree in lengthwise and crosswise using stack lift equipment. And the stack is operated in 10~100% load. No significant change has appeared in crosswise inclined condition and lenthwise low angle. But in lenthwise large angle tilting condition, the fuel cell performance has significantly decreased. And this performance decrease is aggravated in low load. An active water exhaust device is applied to the stack to prevent the performance decrease. And in lenthwise large angle tilting condition, this device cause a good effect to fuel cell stack performance.

  • PDF

Stack Trace 기반 Bug report 우선순위 자동 추천 접근 방안 (An Automatic Approach for the Recommendation of Bug Report Priority Based on the Stack Trace)

  • 이정훈;김태영;최지원;김순태;류덕산
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2020년도 추계학술발표대회
    • /
    • pp.866-869
    • /
    • 2020
  • 소프트웨어 개발 환경이 빠르게 변화함에 따라 시스템의 복잡성이 증가하고 있다. 이에 따라 크고 작은 소프트웨어의 버그를 피할 수 없게 되며 이를 효율적으로 처리하기 위해 Bug report 를 사용한다. 하지만, Bug report 에서 개발자가 해당 Bug report 의 우선순위를 결정하는 과정은 노력과 비용 그리고 시간을 많이 소모하게 만든다. 따라서, 본 논문에서는 Bug report 내의 Stack trace 를 기반으로 Bug 의 우선순위를 자동적으로 추천하는 기법을 제안한다. 이를 위해 본 연구에서는 첫 번째로 Bug report 로부터 Stack trace 를 추출하였으며 Stack trace 의 3 가지 요소(Exception, Reason 그리고 Stack frame)에 TF-IDF, Word2Vec 그리고 Stack overflow 를 사용하여 특징 벡터를 정의하였다. 그리고 Bug 의 우선순위 추천 모델을 생성하기 위해 4 가지의 Classification 알고리즘을(Random Forest, Decision Tree, XGBoost, SVM)을 적용하였다. 평가에서는 266,292 개의 JDK library 의 Bug report 데이터를 수집하였고 그중 Stack trace 를 가진 Bug report 로부터 68%의 정확도를 산출하였다.

AMESet 기반 20 kW급 수소 연료전지 시스템 동특성 모델 해석 (Analysis of Dynamic Characteristics of 20 kW Hydrogen Fuel Cell System Based on AMESet)

  • 우종빈;김영현;유상석
    • 한국수소및신에너지학회논문집
    • /
    • 제34권5호
    • /
    • pp.465-477
    • /
    • 2023
  • In proton exchange membrane fuel cell (PEMFC), proper thermal management of the stack and moisture generation by electrochemical reactions significantly affect fuel cell performance. In this study, the PEMFC dynamic characteristic model was developed through Simcenter AMESim, a development program. In addition, the developed model aims to understand the thermal resin balance of the stack and performance characteristics for input loads. The developed model applies the thermal management model of the stack and the moisture content and permeability model to simulate voltage loss and stack thermal behavior precisely. This study extended the C based AMESet (adaptive modeling environment submodeling tool) to simulate electrochemical reactions inside the stack. Fuel cell model of AMESet was liberalized with AMESim and then integrated with the balance of plant (BOP) model and analyzed. And It is intended to be used in component design through BOP analysis. The resistance loss of the stack and thermal behavior characteristics were predicted, and the impact of stack performance and efficiency was evaluated.

Numerical Model for Stack Gas Diffusion in Terrain Containing Buildings - Application of Numerical Model to a Cubical Building and a Ridge Terrain -

  • Sada, Koichi;Michioka, Takenobu;Ichikawa, Yoichi
    • Asian Journal of Atmospheric Environment
    • /
    • 제2권1호
    • /
    • pp.1-13
    • /
    • 2008
  • A numerical simulation method has been developed to predict atmospheric flow and stack gas diffusion using a calculation domain of several km around a stack under complex terrain conditions containing buildings. The turbulence closure technique using a modified k-$\varepsilon$-type model under a non hydrostatic assumption was used for the flow calculation, and some of the calculation grids near the ground were treated as buildings using a terrain-following coordinate system. Stack gas diffusion was predicted using the Lagrangian particle model, that is, the stack gas was represented by the trajectories of released particles. The numerical model was applied separately to the flow and stack gas diffusion around a cubical building and to a two-dimensional ridge in this study, before being applied to an actual terrain containing buildings in our next study. The calculated flow and stack gas diffusion results were compared with those obtained by wind tunnel experiments, and the features of flow and stack gas diffusion, such as the increase in turbulent kinetic energy and the plume spreads of the stack gas behind the building and ridge, were reproduced by both calculations and wind tunnel experiments. Furthermore, the calculated profiles of the mean velocity, turbulent kinetic energy and concentration of the stack gas around the cubical building and the ridge showed good agreement with those of wind tunnel experiments.

성능이 향상된 Stack Monitoring System의 설계 (Design of Stack Monitoring System with Improved Performance)

  • 장경욱;이주현;이승원;이승호
    • 전기전자학회논문지
    • /
    • 제20권3호
    • /
    • pp.299-302
    • /
    • 2016
  • 본 논문에서는 성능이 향상된 Stack Monitoring System을 설계한다. Stack Monitoring System의 증폭기(AMP)에 들어오는 펄스성 잡음을 차단하기 위하여, 차폐 및 전원부 임피던스를 낮추고 전원회로를 분리하여 노이즈를 차단한다. 신틸레이션 검출기 특성을 최대한 장치에 매칭하기 위한 가변 고전압, 이득(Gain), 상쇄(Offset), 한계(Threshold) 등을 설정 할 수 있는 제어부를 설계한다. 또한 300 ~ 1,500V의 가변 고전압 전원회로를 구성하여 다양한 신틸레이션 검출기에 적용가능 한 가변 전압 공급 장치를 설계한다. 성능이 향상된 Stack Monitoring System은 다종의 신틸레이션 검출기가 각각의 특성을 고려하여 동작하게 함으로서 효율적이고 높은 신뢰성을 보장한다. 개발된 Stack Monitoring System의 측정 불확도에 대하여 공인 시험기관의 장비를 사용하여 실험한 결과 우수한 성능을 나타내었다.

Evaluation of the Impacts of Stack Effect in High-Rise Buildings

  • Yang, In-Ho;Jo, Jae-Hun;Yeo, Myoung-Souk;Kim, Kwang-Woo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권2호
    • /
    • pp.91-103
    • /
    • 2003
  • The objective of this study is to analyze and evaluate the impact of the stack effect in high-rise buildings for solving the various problems resulting from it. For the evaluation of the impacts on the stack effect, computer program simulations based on the network model were performed for a typical high-rise office building. The results of the simulations show that the impact caused by the stack effect is mainly dependent on building envelope air-tightness and internal air flow resistance. Therefore the problems due to the stack effect may be solved to some extent by installing vestibules around entrance doors and doors serving elevators, and by zoning the elevators.

초고층 건축물에서 급기가압제연이 연돌효과에 미치는 영향 (The Influence on the Stack effect that Pressure differential system to smoke control in High-rise buildings)

  • 임채현;박용환
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.235-238
    • /
    • 2008
  • High-rise buildings with stack effect caused by the foreclosure, which significantly delayed the spread of a fire in effects of these stack effect driving force said. In this research on the stack effect of the lobby if the pressurization of the stairwell analysis of the pressure distribution of the CONTAMW. Overall, the pressurization of the lobby makes it stairwell amount of pressure(+) to the zone in pressure designed to prevent the spread of smoke control performance and found that, the way a normal state and sub-pressurization in the stairwell with stack effect of the turbulence Such as the formation of the upper flow, but, in the upper atmosphere with pressurization was formed by the underlying trend.

  • PDF

Experimental Analyses of Cell Voltages for a Two-cell PEM Stack Under Various Operating Conditions

  • Park, Sang-Kyun;Choi, Jae-Hyuk
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제35권7호
    • /
    • pp.881-890
    • /
    • 2011
  • Analyses of performance and behavior of the individual PEM fuel cells (PEMFC) under different operating conditions are of importance optimally to design and efficiently to operate the stack. The paper focuses on experimental analyses of a two-cell stack under different operating conditions, which performance and behavior are measured by the voltage of a cell as well as the stack. Experimental parameters include stoichiometric ratio, temperature of the air supplied under different working stack temperatures and loads. Results showed that the cell voltages are dominantly influenced by the temperature of the air supplied among others. In addition, an inherent difference between the first and the second cell voltage exists because of the tolerances of the cell components and the resulting different over-potentials at different equilibrium states. Furthermore, it is shown that the proton conductivity in the membranes conditioned by the humidity in the cathode channel highly affects the voltage differences of the two cells.

승용차용 연료전지 스택 개발 (Development of PEMFC Stack for passenger car application)

  • 이종현;금영범;양유창;김세훈
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.553-556
    • /
    • 2007
  • Hyundai${\cdot}$Kia Motors have developed PEMFC stack technologies for passenger car application in 1998. The developed 80kW class stack, which was installed Kia's Sportage FCV in 2005, has been modified for -10$^{\circ}C$ cold start-up and ensuring the stability and durability by using new technologies such as newly designed separator, manifold block, end plate, and so on. And also, the stack durability has been verified over 1,500hrs with the condition of combined vehicle driving mode. Hyundai${\cdot}$Kia Motors will keep continuing the stack R&D to reach the goal of FCV commercialization.

  • PDF