• Title/Summary/Keyword: stable range one

Search Result 319, Processing Time 0.023 seconds

Metal Transfer Characteristics of Aluminium under Pulsed Current Metal Inert Gas Welding (알루미늄의 펄스 전류 미그 용접)

  • 최재호;최병도;김용석
    • Journal of Welding and Joining
    • /
    • v.20 no.5
    • /
    • pp.127-133
    • /
    • 2002
  • In this study, metal transfer characteristics in pulsed current metal inert gas (MIG) welding of aluminum was investigated. Based on the metal transfer characteristics from direct current electrode negative MIG welding, the one drop per one pulse(ODOP) condition was predicted and compared with experimental data. The results indicated that experimental pulse range for the ODOP condition is wider than that predicted from the DCEP MIG welding data. In addition, more stable metal trnasfer behavior was obtained at the higher end of the ODOP condition.

Total Ankle Arthroplasty for the Post-traumatic Osteoarthritis (외상후성 관절염에 대한 족관절 인공관절 전치환술)

  • Lee, Keun-Bae;Cho, Sang-Gwon;Kim, Byung-Soo;Choi, Min-Sun
    • Journal of Korean Foot and Ankle Society
    • /
    • v.11 no.1
    • /
    • pp.45-50
    • /
    • 2007
  • Purpose: To evaluate the short-term clinical outcomes of total ankle arthroplasty for the post-traumatic osteoarthritis. Materials and Methods: Fourteen patients who had undergone total ankle arthroplasty from February 2005 to June 2006 were reviewed. Eleven patients were male and three patients were female. The mean age was 52.8 years (range, 33 to 69 years). The mean follow-up duration was 15.9 months (range, 12 to 24 months). Primary injuries were pilon fractures in eight cases, malleolar fractures in three, ankle syndesmotic injury in one, talus fracture and dislocation in one, and distal tibial physeal injury in one. Visual analogue scale (VAS), Range of motion (ROM), American Orthopaedic Foot and Ankle Society (AOFAS) score and complications were evaluated. Results: The mean VAS improved from 8.6 preoperatively to 2.6 at last follow-up. The mean ROM improved from 24.6 degrees preoperatively to 33.1 degrees postoperatively. The mean AOFAS score improved from 44.5 points preoperatively to 75.1 points postoperatively. Radiographically, all components were stable, but there were component malpositions in two cases, including one varus malposition of tibial component and one increased anterior translation of talar component. Complications were deep infection in one case, intraoperative malleolar fracture in three, marginal wound necrosis in two, and heterotopic ossification in one. One prosthesis was revised because of deep infection. Conclusion: Total ankle arthroplasty for the post-traumatic osteoarthritis is believed to be an useful method for preservation of the motion, relief of the pain and high satisfaction of patients in short-term results.

  • PDF

Electrical and optical properties of ZnO:Al thin films prepared by reactive sputtering method (반응성 sputtering법으로 제막된 ZnO : Al 박막의 전기.광학적 특성)

  • 유병석;유세웅;이정훈
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.6 no.4
    • /
    • pp.480-492
    • /
    • 1996
  • AZO (Aluminum doped Zinc Oxide) transparent conducting thin films were fabricated by reactive DC mangnetron sputtering method using zinc target containing 2 wt% of Al. Transition range with optimum transmittance and conductivity was obtained by contrlling partial pressure of reactive oxygen gas. Sputtering condition for this transition range could be kept stable by regulating the target voltage. According to XRD analysis, there was only one peak for (002) plane in AZO films and the films deposited in transition range.

  • PDF

Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

  • Kim, Sung-Eun;Jung, Dong-Woo;Chung, Kyu-Jin;Lee, Jun Ho;Kim, Tae Gon;Kim, Yong-Ha;Lee, Soo Jung;Kang, Su Hwan;Choi, Jung Eun
    • Archives of Plastic Surgery
    • /
    • v.41 no.5
    • /
    • pp.529-534
    • /
    • 2014
  • Background In 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience. Methods From November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction. Results The mean breast resection volume was 240 mL (range, 83-540 mL). The mean size of the breast implants was 217 mL (range, 125-395 mL). Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen. Conclusions By using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.

A Study on the Stability of Rich/Lean Methane Premixed Flame (과농/희박 메탄 예혼합화염의 안정성에 관한 연구)

  • Lee, Won-Nam;Seo, Dong-Kyu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.2
    • /
    • pp.170-177
    • /
    • 2005
  • The fuel-lean premixed flame has been considered one of the most efficient ways to reduce $NO_X$ emission during a combustion process. However, it is difficult to achieve stable fuel-lean premixed flames over the wide range of equivalence ratios: therefore, the application of fuel-lean flames to a practical combustion system is rather limited. In this study, the stability characteristics of fuel-lean flames stabilized by fuel-rich flames are investigated experimentally using a slot burner as a part of the basic research for practical application such as lean burn engines. Spontaneous emission of radical species were examined to understand the stability mechanisms of rich-lean premixed flames. The presence of fuel-rich flames could significantly lower the lean limit of fuel-lean flames. The stability of a fuel-lean flame is enhanced with the increase of fuel flow rate in a fuel-rich flame; how ever, it is not sensitive to the equivalence ratio of fuel-rich flames in the range of 1.2-2.4. The mechanisms of stable rich-lean premixed flames could be understood based on the characteristics of triple flame.

Humidity Calibration for a Pressure Gauge Using a Temperature-Stable Quartz Oscillator

  • Suzuki, Atsushi
    • Applied Science and Convergence Technology
    • /
    • v.25 no.6
    • /
    • pp.124-127
    • /
    • 2016
  • Humidity calibration for a temperature-stable quartz oscillator (TSQO) was investigated to exclude the influences of relative humidity on the TSQO output in order to use the corresponding devices outdoors. The TSQO output is a voltage that is inversely proportional to the electric impedance of the quartz oscillator, which depends on the viscosity and density of the measured gas. The TSQO output was humidity calibrated using its humidity dependence, which was obtained by varying the relative humidity (RH) from 0 to 100 RH% while other conditions were kept constant. The humidity dependencies of the TSQO output were fit by a linear function. Subtracting the change in the TSQO output induced by the change in humidity, calculated with the function from the experimentally measured TSQO output for a range of 0-100RH%, eliminated the influence of humidity on the TSQO output. The humidity calibration succeeded in reducing the fluctuations of the TSQO output from 0.4-3% to 0.1-0.3% of the average values for a range of 0-100RH%, at constant temperatures. The necessary stability of the TSQO output for application in hydrogen sensors was below one-third of the change observed for a hydrogen leakage of 1 vol.% hydrogen concentration, corresponding to 0.33% of the change in each background. Therefore, the results in this study indicate that the present humidity calibration effectively suppresses the influence of humidity, for the TSQO output for use as an outdoor hydrogen sensor.

Design of Bi-stable Mechanism Using Cylindrical Permanent Magnets (원통형 영구자석을 이용한 쌍안정 장치 설계)

  • Yang, Hyeon-Ho;Choi, Jae-Yong;Han, Jae-Hung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.5
    • /
    • pp.343-354
    • /
    • 2020
  • Bi-stable mechanism is a system that has two different stable equilibrium positions within its range of motion. It has an ability to stay in two different positions without external power input and despite small disturbances. One of the most bi-stable applied mechanism is a morphing system, such as deployable structures, switch systems, and robot grippers. However, due to the complexity of mechanism and limitation of structure configuration, it is difficult to apply on a morphing system with rotating link mechanism. In this paper, an implementation method of rotational bi-stable mechanism using cylindrical permanent magnets is proposed. The magnetic field and the magnetic force were calculated from electromagnet model of the cylindrical permanent magnet. Based on the model, the force relation between two links containing the cylindrical permanent magnets was estimated. An array of cylindrical permanent magnets was selected for symmetric bi-stability, and an experiment on the link structure with the proposed bi-stable mechanism was performed to investigate the stability against a external torque.

Reliable stabilizing multi-controller for steam generator level control (증기발생기 수위제어를 위한 다중 안정화 제어기 설계)

  • 권현진;박상현;이상정;함창식
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1229-1232
    • /
    • 1996
  • This paper proposes the passive redundancy algorithm of multi-controller structure applicable to the steam generator level control system in the low power operating range. In the passive redundancy scheme of multi-controller structure, two suitable controllers exist if the plant is strongly stabilizable. One of the two controllers can be selected arbitrarily only if it is stable. In particular, this paper shows that the passive redundancy scheme can be efficiently used with PID and GPC control algorithms through simulation studies on the control of the steam generator.

  • PDF

FCXO ; A Fuzzy Compensated Crystal Oscillator

  • de los Mozos, Mario Reyesr;Valderrama, Elena;Arguelles, Javier
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 1993.06a
    • /
    • pp.842-844
    • /
    • 1993
  • We present a F.L.C. (Fuzzy Logic Controller) to control of the oscillation frequency of a V.C.X.O. (Voltage Controled Crystal Oscillator). This F.C.X.O. maintains stable its oscillation frequency inside a range of 1 ppm (one part per millon), with temperature between -55$^{\circ}C$ to+75$^{\circ}C$.

  • PDF