• 제목/요약/키워드: stable limits

검색결과 151건 처리시간 0.028초

High Performance Flexible Inorganic Electronic Systems

  • 박귀일;이건재
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.115-116
    • /
    • 2012
  • The demand for flexible electronic systems such as wearable computers, E-paper, and flexible displays has increased due to their advantages of excellent portability, conformal contact with curved surfaces, light weight, and human friendly interfaces over present rigid electronic systems. This seminar introduces three recent progresses that can extend the application of high performance flexible inorganic electronics. The first part of this seminar will introduce a RRAM with a one transistor-one memristor (1T-1M) arrays on flexible substrates. Flexible memory is an essential part of electronics for data processing, storage, and radio frequency (RF) communication and thus a key element to realize such flexible electronic systems. Although several emerging memory technologies, including resistive switching memory, have been proposed, the cell-to-cell interference issue has to be overcome for flexible and high performance nonvolatile memory applications. The cell-to-cell interference between neighbouring memory cells occurs due to leakage current paths through adjacent low resistance state cells and induces not only unnecessary power consumption but also a misreading problem, a fatal obstacle in memory operation. To fabricate a fully functional flexible memory and prevent these unwanted effects, we integrated high performance flexible single crystal silicon transistors with an amorphous titanium oxide (a-TiO2) based memristor to control the logic state of memory. The $8{\times}8$ NOR type 1T-1M RRAM demonstrated the first random access memory operation on flexible substrates by controlling each memory unit cell independently. The second part of the seminar will discuss the flexible GaN LED on LCP substrates for implantable biosensor. Inorganic III-V light emitting diodes (LEDs) have superior characteristics, such as long-term stability, high efficiency, and strong brightness compared to conventional incandescent lamps and OLED. However, due to the brittle property of bulk inorganic semiconductor materials, III-V LED limits its applications in the field of high performance flexible electronics. This seminar introduces the first flexible and implantable GaN LED on plastic substrates that is transferred from bulk GaN on Si substrates. The superb properties of the flexible GaN thin film in terms of its wide band gap and high efficiency enable the dramatic extension of not only consumer electronic applications but also the biosensing scale. The flexible white LEDs are demonstrated for the feasibility of using a white light source for future flexible BLU devices. Finally a water-resist and a biocompatible PTFE-coated flexible LED biosensor can detect PSA at a detection limit of 1 ng/mL. These results show that the nitride-based flexible LED can be used as the future flexible display technology and a type of implantable LED biosensor for a therapy tool. The final part of this seminar will introduce a highly efficient and printable BaTiO3 thin film nanogenerator on plastic substrates. Energy harvesting technologies converting external biomechanical energy sources (such as heart beat, blood flow, muscle stretching and animal movements) into electrical energy is recently a highly demanding issue in the materials science community. Herein, we describe procedure suitable for generating and printing a lead-free microstructured BaTiO3 thin film nanogenerator on plastic substrates to overcome limitations appeared in conventional flexible ferroelectric devices. Flexible BaTiO3 thin film nanogenerator was fabricated and the piezoelectric properties and mechanically stability of ferroelectric devices were characterized. From the results, we demonstrate the highly efficient and stable performance of BaTiO3 thin film nanogenerator.

  • PDF

Tribological study on the thermal stability of thick ta-C coating at elevated temperatures

  • Lee, Woo Young;Ryu, Ho Jun;Jang, Young Jun;Kim, Gi Taek;Deng, Xingrui;Umehara, Noritsugu;Kim, Jong Kuk
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.144.2-144.2
    • /
    • 2016
  • Diamond-like carbon (DLC) coatings have been widely applied to the mechanical components, cutting tools due to properties of high hardness and wear resistance. Among them, hydrogenated amorphous carbon (a-C:H) coatings are well-known for their low friction properties, stable production of thin and thick film, they were reported to be easily worn away under high temperature. Non-hydrogenated tetrahedral amorphous carbon (ta-C) is an ideal for industrial applicability due to good thermal stability from high $sp^3$-bonding fraction ranging from 70 to 80 %. However, the large compressive stress of ta-C coating limits to apply thick ta-C coating. In this study, the thick ta-C coating was deposited onto Inconel alloy disk by the FCVA technique. The thickness of the ta-C coating was about $3.5{\mu}m$. The tribological behaviors of ta-C coated disks sliding against $Si_3N_4$ balls were examined under elevated temperature divided into 23, 100, 200 and $300^{\circ}C$. The range of temperature was setting up until peel off observed. The experimental results showed that the friction coefficient was decreased from 0.14 to 0.05 with increasing temperature up to $200^{\circ}C$. At $300^{\circ}C$, the friction coefficient was dramatically increased over 5,000 cycles and then delaminated. These phenomenon was summarized two kinds of reasons: (1) Thermal degradation and (2) graphitization of ta-C coating. At first, the reason of thermal degradation was demonstrated by wear rate calculation. The wear rate of ta-C coatings showed an increasing trend with elevated temperature. For investigation of relationship between hardness and graphitization, thick ta-C coatings(2, 3 and $5{\mu}m$) were additionally deposited. As the thickness of ta-C coating was increased, hardness decreased from 58 to 49 GPa, which means that graphitization was accelerated. Therefore, now we are trying to increase $sp^3$ fraction of ta-C coating and control the coating parameters for thermal stability of thick ta-C at high temperatures.

  • PDF

사출성형 공정에서 유발되는 냄새의 후각 감성 특성 (Olfactory Sensitivity Characteristics of Odors from Injection Molding Processing)

  • 류영재;김보성;이예현;곽승현;서상혁;류태범;민병찬
    • 산업경영시스템학회지
    • /
    • 제39권4호
    • /
    • pp.67-71
    • /
    • 2016
  • The purpose of this study was to explore olfactory sensitivity of odors from injection molding processing. To do this, the experiment was carried out in an injection molding factory, and participants were exposed to the environment where odor-substances (Formaldehyde, Benzene, Toluene, Ethylbenzene, Xylene, Styrene) exist. In addition, we used the subjective scale using semantic adjectives as an olfactory sensitivity. As a result, the assessment structure of olfactory sensitivity was composed of eight factors (irritant, thermal, tense, unique, like-dislike, active, stable, masculine), and the main factor which was irritant characteristics explained 20% of the total olfactory sensibility. These results suggested that odors from injection molding processing would cause more negative emotional responses than the flavor which is mainly used in olfactory sensitivity. This study, as a basic study of the improvement in a factory environment for the efficiency of work, has limits in that it was conducted to the extent of identifying the olfactory sensitivity structure of those who were at a laboratory and who were exposed to the environment of odor substance induced in the injection molding processing. Therefore, for the method of removing malodorous substance, the effect of materials which can neutralize it, and the comparison of a direct performance in the environment where negative sensitivity structure exists, a series of studies which aim to improve the environment of injection molding factories, such as performance assessment in the environment of a factory and an office need to be conducted. It is expected that when these studies are put together, the improvement guidelines will be provided as a type that can maximize the effectiveness of work in the factory environment where injection molding processing is done.

고온연료의 점화 및 화염 소화특성에 미치는 복사효과 (Radiation Effects on the Ignition and Flame Extinction of High-temperature Fuel)

  • 김유정;오창보;최병일;한용식
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.50-56
    • /
    • 2013
  • 대향류 비예혼합 연료-공기 유동장에서 고온연료의 점화특성과 형성된 화염의 소화특성에 미치는 복사효과에 대해 수치계산을 통해 검토하였다. 화학반응의 계산을 위해 GRI-v3.0의 상세화학반응기구를 사용하였으며, 단열계산과 광학적으로 얇은 복사모델을 적용하여 계산을 수행하였다. 대향류 유동장의 점화와 소화점을 정확히 찾기 위하여 화염제어 연속계산법을 적용하였다. 결과를 통해 스트레인율 변화에 대해 최고 온도보다는 최고 H 라디칼 농도가 점화와 소화거동을 이해하는데 더 적합하다는 것을 확인하였다. 최고 H 라디칼 농도변화 거동을 통해 기존에 알려진 S-곡선, C-곡선 및 O-곡선 등을 확인하였다. 복사열손실 분율($f_r$)과 공간에 대해 적분된 열발생률(IHRR)을 통해 $f_r$이 가장 큰 점에서 복사효과에 의한 소화가 발생하였으며, 화염신장 소화점에서는 IHRR이 가장 높지만 화염에서의 전도에 의한 열손실로 인해 소화가 되는 것을 확인하였다. 복사는 화염신장 소화점에는 거의 영향이 없지만 복사 소화점과 점화점에는 큰 영향을 주는 것을 알 수 있었다. 또한 연료의 온도가 높아질수록 복사에 의한 소화점의 스트레인율과 화염신장에 의한 스트레인율 사이의 영역이 넓어지게 되어 화염 안정성이 향상되고 있음을 알 수 있었다.

탄소나노튜브를 이용한 고휘도 마이크로빔 X-선원 발생부 설계 (Design of X-ray Target for a CNT-based High-brightness Microfocus X-ray Tube)

  • ;김선규;허성환;조성오
    • 한국진공학회지
    • /
    • 제15권1호
    • /
    • pp.103-109
    • /
    • 2006
  • 전자빔원으로 탄소나노튜브에 기초를 두고 있는 고휘도 마이크로빔 X선원용 타첫이 설계되었다. X-선원은 다음과 같은 제원을 따른다. $1\times10^{11} phs/s.mm^2.mrad^2$. 고휘도, 5 mm의 빔의 크기, $20\~40keV$ 평균 X-선 에너지. 제원을 만족시키기 위해서 구성, 물질, 타겟의 두께와 필요한 빔전류와 같은 타켓의 설계 변수들은 MCNPX code를 통해서 최적화되었다. 설계 변수들은 투과형 타겟 구조를 위해 X-선원의 스펙트럼과 세기의 분포의 계산으로부터 결정되었다 진공압력과 국소화된 열의 누적을 견디기 위한 투과형 타겟 구조를 위해서 구조적인 안정성과 온도 분포도 또한 고려되었다. 타겟 물질은 몰리보덴으로 선택되었고 최적화된 두께는 2mm로서 150mm 두께의 베릴륨이 붙여져 있다 부가적으로 투과형 타겟의 최대 온도가 안정적인 작동의 한계 내에서 유지될 수 있다는 것을 계산을 통하여 알게 되었다.

NIR as a tool for optimizing sampling time and studying batch dynamics.

  • Zeppelin, Joanna
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1126-1126
    • /
    • 2001
  • The paper presented here is the initial part of a larger study, in which it was determined which quality parameters in cheese powder could already be predicted by NIR at an early stage in the process and which could only be predicted at the final stages of the process. This initial study was performed in order to establish the levels and nature of variation within and between batches such that the subsequent data collection could be tackled optimally. The perspectives evolved into more than was originally planned and revealed some interesting uses of NIR-technology. Cheese powder production starts as a batch process, where waste cheese from other dairies is melted down in a vat. The process then turns into a continual process as the vat is emptied and the melted cheese is then filtered, homogenized, pasteurized and finally spray dried. Between each batch the powder is to a greater or lesser degree a mixture of 2 batches. This paper is divided into 2 aspects, one regarding the optimization of sampling time and the other is a study of process dynamics. Optimizing sampling time This initial study included 9 powder samples from 9 different batches produced during one day. The raw materials for the batches were chosen with the aim of creating a relatively high level of variation in the data. The total of 81 samples were taken out at regular intervals and spectra were collected on a NIR-systems 6500 instrument. The subsequent reduction of the data by PCA to score values shows the power of NIR as a tool to determine not only when samples are representative of a certain batch, but also which batches are stable enough to include in a further study. Studying process dynamics To take this experiment a step further 1 of the 81 samples were sent to the laboratory for further analyses. The samples were chosen on the criteria that they covered the spectral variation in the dataset. These samples were analysed for 4 chemical components and 5 physical attributes, which are essential for describing the quality of the product. The latent structure of the 7 samples, using the chemical and physical variables, is totally comparable to the latent structure of the NIR spectra. This outcome makes it possible to describe the dynamics of one day's production both chemically and physically with relatively little resources. Additionally it raises the question as to whether reference values are needed, as the latent structure of the NIR-spectra appears to be sufficient in providing information on the quality of the product. To be able to use NIR in this way would require defining quality limits in the principal component space as opposed to each of the reference values. The potential of NIR applied in an explorative fashion with batch processes opens a whole new gateway for the use of this technology. This study explains yet again after so many years in the field “why I'm crazy about NIR!”.

  • PDF

Evaluation of tissue ingrowth and reaction of a porous polyethylene block as an onlay bone graft in rabbit posterior mandible

  • Sosakul, Teerapan;Tuchpramuk, Pongsatorn;Suvannapruk, Waraporn;Srion, Autcharaporn;Rungroungdouyboon, Bunyong;Suwanprateeb, Jintamai
    • Journal of Periodontal and Implant Science
    • /
    • 제50권2호
    • /
    • pp.106-120
    • /
    • 2020
  • Purpose: A new form of porous polyethylene, characterized by higher porosity and pore interconnectivity, was developed for use as a tissue-integrated implant. This study evaluated the effectiveness of porous polyethylene blocks used as an onlay bone graft in rabbit mandible in terms of tissue reaction, bone ingrowth, fibrovascularization, and graft-bone interfacial integrity. Methods: Twelve New Zealand white rabbits were randomized into 3 treatment groups according to the study period (4, 12, or 24 weeks). Cylindrical specimens measuring 5 mm in diameter and 4.5 mm in thickness were placed directly on the body of the mandible without bone bed decortication, fixed in place with a titanium screw, and covered with a collagen membrane. Histologic and histomorphometric analyses were done using hematoxylin and eosin-stained bone slices. Interfacial shear strength was tested to quantify graft-bone interfacial integrity. Results: The porous polyethylene graft was observed to integrate with the mandibular bone and exhibited tissue-bridge connections. At all postoperative time points, it was noted that the host tissues had grown deep into the pores of the porous polyethylene in the direction from the interface to the center of the graft. Both fibrovascular tissue and bone were found within the pores, but most bone ingrowth was observed at the graft-mandibular bone interface. Bone ingrowth depth and interfacial shear strength were in the range of 2.76-3.89 mm and 1.11-1.43 MPa, respectively. No significant differences among post-implantation time points were found for tissue ingrowth percentage and interfacial shear strength (P>0.05). Conclusions: Within the limits of the study, the present study revealed that the new porous polyethylene did not provoke any adverse systemic reactions. The material promoted fibrovascularization and displayed osteoconductive and osteogenic properties within and outside the contact interface. Stable interfacial integration between the graft and bone also took place.

링크관측교통량을 이용한 도시부 OD 통행행렬 추정 (GA와 SAB 알고리즘의 비교를 중심으로) (OD trip matrix estimation from urban link traffic counts (comparison with GA and SAB algorithm))

  • 백승걸;김현명;임용택;임강원
    • 대한교통학회지
    • /
    • 제18권6호
    • /
    • pp.89-99
    • /
    • 2000
  • 전통적인 OD조사에 의한 OD추정방법의 여러 문제점들로 인해 링크에서 관측된 교통량과 기존OD를 결합해 새로운 OD를 추정하고자 하는 연구들이 지속되고 있으며, 그 필요성도 증대되고 있다. 그러한 기법중의 하나가 Yang(1995)이 제시한 바이레벨 모형으로, 그는 일반화최소자승법을 풀기위한 Sensitivity Analysis Based (SAB)을 제시하였다. 그러나 SAB 알고리즘은 두가지 중요한 문제점을 가지고 있다. 첫 번째 문제는 실제 OD를 알기가 어렵기 때문에, 기존 OD 조사시의 통행패턴이 현재의 통행패턴과 큰 변화가 없다는 가정 하에, 기존 OD를 추정시 중요한 추정기준으로 설정한다는 점이다. 그러나 이러한 기존 OD에 대한 추정의 종속성으로 인해, SAB는 기존 OD와 실제 OD의 차이가 큰 경우 정확한 해를 도출하지 못하고 추정결과가 일관적(robust)이지 않게 도출된다. 두 번째 문제는 SAB는 통행패턴 추정시 선형근사화를 가정하기 때문에 게임이론적 측면에서 전제로 설정한 완전한 Stackelberg 상황을 구현하지 못한다는 점이다. 이러한 문제점을 피하기 위해서는 기존 OD의 오차나 관측교통량의 오차에 대해 일관적이고 안정적인 해도출 기법이 필요하다. 본 연구의 목적은 SAB를 비롯한 기존 바이레벨 OD추정기법의 문제점을 지적하고 이에 대한 대안기법을 제시하는 것이다. OD추정의 문제는 본질적으로 비선형이고 비볼록하기 때문에, 다중해를 도출하게 된다. 따라서 전역해 탐색기법이 필요한데, 본 연구에서는 전역최적화가 가능한 유전알고리즘(Genetic Algorithm)을 이용한 OD추정모형(GA-Model:GAM)을 제시하였다. 사례네트워크에 대한 비교분석결과, GAM은 기존 OD의 오타에 대해 크게 종속적이지 않으며 OD구조가 변하는 경우에도 추정이 가능하여, 일반적으로 실제 OD를 알 수 없는 (기존OD의 오차가 어느 정도인지를 알 수 없는) 도시부 네트워크에서 신뢰성있는 추정력을 보였다.

  • PDF

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 1999년도 추계학술발표회 초록집
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF

시료고체상분산(matrix solid phase dispersion)전처리법을 이용한 식육중 테트라사이클린계 항생물질 동시정량분석 (Multiresidue matrix solid phase dispersion (MSPD) extraction and HPLC determination of tetracyclines in animal muscle tissue)

  • 강환구;손성완;조병훈;이혜숙;박신자;김재학;조명행
    • 대한수의학회지
    • /
    • 제36권3호
    • /
    • pp.541-550
    • /
    • 1996
  • Tetracycline antibiotics have been widely used not only therapeutics but feed additives. There are many methods for the isolation and determination of tetracycline antibiotics in animal muscle tissue. But those methods take much time and labor, so it is difficult to analyse many samples simultaneously. A rapid isolation method and liquid chromatographic determination of tetracycline antibiotics in animal muscle tissue (bovine, porcine, chicken) is presented. Blank control and tetracyclines fortified samples (0.5g) were blended with $C_{18}$ containing 0.05g each of oxalic acid and disodium ethylenediaminetetraacetate. After homogenize, homogenate was transferred to glass column made from 10ml glass syringe and compressed to 4~4.5ml volume. A column made from the $C_{18}$/meat matrix was washed with hexane (8ml) and dichloromethane (8ml, if needed), following which the tetracyclines were eluted,vith methanol or 0.01M methanolic oxalic acid (8ml). The eluates containing tetracyclines analytes were free from interfering compounds when analysed by HPLC with UV detection (photodiode array at 360nm). Standard curve for each tetracycline showed a linear response at the range of $0.05{\sim}1.0{\mu}g/ml$ and tetracycline antibiotics were eluted within 4ml of eluted volume. All tetracycline antibiotics except tetracycline were stable during the concentration process at $40^{\circ}C$ and time required for concentration was 3~4 hours. Fortified samples containing oxalic aicd and EDTA represented more good recoveries than those of not-contained sample. Recoveries were 91.8~110.1% (oxytetracycline; OTC), 57.7~79.5% (tetracycline; TC), 78.1~88.6% (chlortetracyclines; CTC) and 88.4~100.6% (doxycycline; DC) in pork tissue, 101.1~126.8% (OTC), 66.4~75.4% (TC), 79.2~88.1% (CTC) and 69.3~86.7% (DC) in beef tissue, and 90.8~95.6% (OTC), 66.2~84.4% (TC), 75.7~77.2% (CTC) and 55.6~80.7% (DC) in chicken muscle tissue. The detection limits validated in muscle tissue by this method were $0.05{\mu}g/g$ for OTC and TC, and $0.1{\mu}g/g$ for CTC and DC.

  • PDF