• Title/Summary/Keyword: stability period

Search Result 1,554, Processing Time 0.028 seconds

Study on the Storage of Chestnut (밤 저장(貯藏)에 관(關)한 연구(硏究))

  • Yim, Ho;Kim, Choung-Ok;Shin, Dang-Wha;Suh, Kee- Bong
    • Korean Journal of Food Science and Technology
    • /
    • v.12 no.3
    • /
    • pp.170-175
    • /
    • 1980
  • A mass production of chestnut necessiates the development of economic long-term storage method. The main objective of this study was to confirm the technical aspect of the chestnut storage method which was developed by two year project and to review the method of commercial application. The chestnut used for the experiments were separated in brine $(5.5{\sim}6.0^{\circ}\:B{\acute{a}}ume)$ into matured and unmatured lots and fumigated with $CS_2$ at a 5 $lb/27\;m^3$ level for $25{\sim}30\;hrs.$ The chestnuts were packed in wooden boxes with sawdust (50% moisture) in the ratio of 1 : 1 by volume. The boxes were stored in the cold room $(1{\pm}1^{\circ}C,\;85{\sim}95%\;RH)$ and the cellar ($0{\sim}10^{\circ}C$, controlled only by circulating night cool air). The results obtained were as follows: 1. Fully matured chestnut could be successfully preserved $8{\sim}9\;months$ at a l0% decay level in the cold room and $4{\sim}5\;months$ months in cellar. 2. Immatured chestnuts wire inferior to the matured in storage stability. At the maximum storage period, its storage life was two months shorter. 3. The heat transfer equation of piled chestnuts with sawdust can be suggested as $T_{\infty}-T_0=(T_{\infty}-T_0){\cdot}10^{-t/320}$ and j and $f_h$ values were 1 and 320 min, respectively. 4. The chestnuts in the package of storage unit had longer shelf life than naked chestnut during the retail distribution at ambient temperature.

  • PDF

Chemical and Functional Characteristics of Mechanically Deboned Chicken Meat and its Utilization in Processed Meat -I. Chemical and Functional Characteristics of Mechanically Deboned Chicken Meat- (기계발골가금육(機械拔骨家禽肉)의 특성(特性) 및 이용(利用)에 관(關)한 연구(硏究) -제(第) 1 보(報) : 기계발골가금육(機械拔骨家禽肉)의 특성(特性)-)

  • Ahn, Byung-Yoon;Kim, Jong-Won;Lee, Yu-Bang
    • Korean Journal of Food Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.171-175
    • /
    • 1981
  • Hand deboned and mechanically deboned chicken meat were produced from domestic broilers and spent layers. Meat yield, chemical composition, functional characteristics, storage stability and microbiogical properties were investigated. The results obtained were as follows: 1. 35% of carcass freight was recovered primarily as hand deboned chicken meat (HDM) and 45% secondarily as mechanically deboned chicken meat(MDM), total meat yield reaching 80% of carcass weight. 2. Moisture, protein, fat. ash and calcium content of MDM were 65, 12, 20, 1.7 and $0.2{\sim}0.4%$, respectively MDM was higher than HDM in fat, ash and calcium, but significantly lower in moisture and protein Total pigment content of MDM was 2.5 times higher than that of HDM, such high content being attributed to the increased inclusion of hemoglobin during the mechanical masceration of carcass in the deboning process. 3. The emulsifying capacity (ES) of MDM per g meat was only 70% that of HDM, but when ES was expressed on unit g of protein basis MDM showed even higher ES than HDM primarily due to the higher proportion of salt soluble protein fraction of MDM. 4. Since the TBA value of MDM increased rapidly after 4 weeks of frozen storage at $-20^{\circ}C$, the maximum possible storage period of MDM is estimated to be about 4 weeks. 5. Total microbial counts of MDM was approximately $1.8{\times}10\;cells/g$ showing no great difference from HDM or red meat.

  • PDF

Comparative Review on the Introduction and Operation of Salary Peak System -Focusing on Korea and Japan- (임금피크제 도입운영에 관한 비교법적 검토 -한국과 일본을 중심으로-)

  • Noh, Jae-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.11
    • /
    • pp.93-103
    • /
    • 2015
  • In this study, it has an intention of arranging an implication based on an effective introduction of a wage peak system in Japan to settle a mandatory retirement at sixty according to a legalization of retirement age at sixty smoothly. Institutionally, retirement age guaranteed type that reduces wage from certain period before retirement is of great importance. In Japan, mainly features the extension of retirement age that focus on keeping aged employment after retirement. In the introduction of the wage peak system, Korea attaches importance to the wage cost savings, but Japan puts emphasis on using aging workforce. Korea wants to promote the aged employment for retirement age at 60, whereas Japan actively push ahead with retirement age 65 and after that time. South Korea needs to reinforce the pensionable age and the connection though the extension of retirement age via the manpower utilization, employment promotion and the stability. It is necessary to prepare a institutional plan to try not to make a gap of the pensions by guaranteeing or extending the retirement age connect to the age of pensioners though the wage peak system. To activate the wage peak system, it is necessary to acknowledge a legal improvement that concedes rational changes such as the rule of employment. An active interpretation is needed currently though, it is more necessary to review the stipulation and the rational changes of the rule of employment that is established by a precedent like the Japanese legislation case. When a disadvantageous change of works rules is made, it is able to consider establishing the provision in the Act on age Discrimination Prohibition in Employment and Aged Employment Promotion, therefore it won't be able to apply the regulation in the rational criterion that satisfies the standards, rather than amending a Article 94 of the Labor Standards Act that makes accepting the approval of the majority of workers.

Shear Strength and Erosion Resistance Characteristics of Stabilized Green Soils (토양안정재를 혼합한 녹생토의 전단강도 및 침식저항특성)

  • Oh, Sewook;Jeon, Jinchul;Kim, Donggeun;Lee, Heonho;Kwon, Youngcheul
    • Journal of the Korean GEO-environmental Society
    • /
    • v.16 no.12
    • /
    • pp.45-52
    • /
    • 2015
  • With the rising interest in the environment, more attention on ecological restoration for damaged slope surface to restore its original state has been drawn. Generally, the most useful method is vegetation based spray work. This method uses green soil including sewage sludge, sawdust, paper sludge, and weathered granite soil. However, because there are neither accurate information nor test values about green soil, green soil is often lost by environmental factors such as rainfalls and strong winds. To solve the problem of green soil, it is necessary to prepare design standards about green soil, and conduct studies to deal with green soil loss in consideration of various variables including basic material property, soil quality of slope surface, and weather. This study was conducted in the mixture of green soil and eco-friendly soil stabilizer. With green soil, basic material property test and compaction test were conducted for the analysis on the basic characteristics of green soil. In the mixture with soil stabilizer at a certain ratio, we conducted shear strength test depending on the ratio in order to analyze the maximum shear strength, cohesion and the change in internal friction angles. Furthermore, in the mixture ratio of green soil and soil stabilizer, which is the same as the ratio in the shear strength test, an inclination of slope surface was made in laboratory for the analysis on erosion and germination rate. Finally, this study evaluated the most effective and economic mixing ratio of soil stabilizer to cope with neighboring environmental factors. According to the test, the shear strength of green soil increased up to 51% rely onto the mixing ratio of and a curing period, and its cohesion and internal friction angle also gradually increases. It is judged that the mixture of soil stabilizer was effective in improving shear strength and thereby increased the stability of green soil.

Effects of Arginine Vasopressin(AVP) Infusion on the Patients with Catecholamine-dependent Septic Shock (카테콜아민계 승압제를 투여중인 패혈성 쇼크 환자에서 아르기닌 바소프레신(AVP)의 효과)

  • Sheen, Seung Soo;Lim, Seung Guan;Jo, Sook Kyoung;Song, Kyoung Eun;Lee, Hyoung No;Oh, Yoon Jung;Park, Kwang Joo;Hwang, Sung Chul
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.5
    • /
    • pp.506-515
    • /
    • 2003
  • Background : A decreased level of serum arginine vasopressin(AVP) and an increased sensitivity to an exogenous AVP is expected in patients with septic shock who often require a high infusion rate of catecholamines. The goal of the study was to determine whether an exogenous AVP infusion to the patients with septic shock would achieve a significant decrement in infusion rate of catecholamine vasopressors while maintaining hemodynamic stability and adequate urine output. Method : Eight patients with septic shock who require a high infusion rate of norepinephrine had received a trial of 4-hour AVP infusion with simultaneous titration of norepinephrine. Hemodynamic parameters and urine output were monitored during the AVP infusion and the monitoring continued up to 4 hours after the AVP infusion had stopped. Results : Mean arterial pressure showed no significant changes during the study period(p=0.197). Norepinephrine infusion rate significantly decreased with concurrent AVP administration(p=0.001). However, beneficial effects had disappeared after the AVP infusion was stopped. In addition, hourly urine output showed no significant changes throughout the trials(p=0.093). Conclusion : Concurrent AVP infusion achieved the catecholamine vasopressor sparing effect in the septic shock patients, but there was no evidence of the improvement of renal function. Further study may be indicated to determine whether AVP infusion would provide an organ-protective effect to the septic shock patients.

The Development of Quality Assurance Program for CyberKnife (사이버나이프의 품질관리 절차서 개발)

  • Jang, Ji-Sun;Kang, Young-Nam;Shin, Dong-Oh;Kim, Moon-Chan;Yoon, Sei-Chul;Choi, Ihl-Bohng;Kim, Mi-Sook;Cho, Chul-Koo;Yoo, Seong-Yul;Kwon, Soo-Il;Lee, Dong-Han
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.185-191
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: Standardization quality assurance (QA) program of CyberKnife for suitable circumstances in Korea has not been established. In this research, we investigated the development of QA program for CyberKnife and evaluation of the feasibility under applications. $\underline{Materials\;and\;Methods}$: Considering the feature of constitution for systems and the therapeutic methodology of CyberKnife, the list of quality control (QC) was established and divided dependent on the each period of operations. And then all these developed QC lists were categorized into three groups such as basic QC, delivery specific QC, and patient specific QC based on the each purpose of QA. In order to verify the validity of the established QA program, this QC lists was applied to two CyberKnife centers. The acceptable tolerance was based on the undertaking inspection list from the CyberKnife manufacturer and the QC results during last three years of two CyberKnife centers in Korea. The acquired measurement results were evaluated for the analysis of the current QA status and the verification of the propriety for the developed QA program. $\underline{Results}$: The current QA status of two CyberKnife centers was evaluated from the accuracy of all measurements in relation with application of the established QA program. Each measurement result was verified having a good agreement within the acceptable tolerance limit of the developed QA program. $\underline{Conclusion}$: It is considered that the developed QA program in this research could be established the standardization of QC methods for CyberKnife and confirmed the accuracy and stability for the image-guided stereotactic radiotherapy.

Latarjet Operation for Anterior Shoulder Instability with Glenoid Bone Defect (관절와 골 결손을 동반한 견관절 전방 불안정증에 대한 Latarjet 술식)

  • Cho, Seung-Hyun;Cho, Nam-Su;Yi, Jin-Woong;Choi, Il-Hun;Kwack, Yoon-Ho;Rhee, Yong-Girl
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.189-198
    • /
    • 2009
  • Purpose: We wanted to evaluate the clinical results of the Latarjet procedure for treating anterior shoulder instability combined with a glenoid bone defect. Materials and Methods: Between Oct. 2006 and May. 2007, fourteen patients underwent a Latarjet operation to treat their anterior shoulder instability combined with a glenoid bone defect. The mean follow-up period was 15 months (range: 12 to 19 months), and the average age at the time of surgery was 29.9-years-old (range: 19 to 44 years). There were 13 males and 1 female. Eight patients exhibited involvement of the right shoulder. The dominant arm was involved in 8 patients. Six patients had undergone a previous arthroscopic Bankart repair before their Latarjet operation and 2 patients had a history of seizure. Results: The average Rowe score improved from 51.8 to 80.2 with 9 excellent, 4 good, and 1 fair results. The average Korean shoulder score for instability improved from 61.6 to 82.1 postoperatively. The active forward flexion and external rotation at the side of the involved shoulder was an average of $8^{\circ}$ and $16^{\circ}$ less than that of the uninvolved shoulder. The muscle strength of the involved shoulder measured 78.7% in forward flexion and 82.5% in external rotation, as compared with that of the uninvolved shoulder. There was 1 case of dislocation, 1 transient subluxation, 2 fibrotic unions, 1 resorption of the transferred coracoid process, 1 intraoperative broken bone, 1 transient musculocutaneous nerve injury and 1 case of stiffness. Conclusion: The Latarjet procedure for treating anterior shoulder instability combined with a significant glenoid defect effectively restores function and stability through extending the articular arc at the expense of external rotation. We should be cautious to avoid or detect complications when performing coracoid transfer.

Arthroscopic ACL Reconstruction Using Fresh-Frozen Achilles Allograft -Clinical results, Recovery of sports activity- (아킬레스 동종건을 이용한 전방십자인대 재건술후 임상적 결과와 운동력 회복 평가)

  • Chun Churl Hong;Ha Dae Ho;Kim Dong Chul;Kim Hyun Jun
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.31-36
    • /
    • 2002
  • Purpose : ACL (anterior cruciate ligament) reconstruction using achilles allograft was done for whom ACL injured person in recreational sports activity. The purpose of this study was to evaluate the clinical results and return to their sports activity in these patients. Materials and Methods : ACL injured 56 amateur athletes who had experienced sports 3 times a week more than 5 years, reconstructed with Achilles allograft, and it was analyzed subjective and objective parameter, Tegner scoring, Telos stress arthrometer, Lysholm Knee Scoring System and modified Feagin scoring system. The average age was 25 years old (range: 18$\~$49), the average follow up period was 15 months (range: 12$\~$19). Morbid sports were football (29 cases), basket ball (14 cases), badminton (5 cases), tennis (3 cases), squash (2 cases) and otherwise (3 cases). Result : The mean Lysholm Knee Scoring System was improved to 88.2 from 60. Telos arthrometer in anterior stress test revealed 2.3 mm improved from 7.1 mm. The modified Feagin scoring system showed 50 cases (89$\%$) with excellent and good results. We had obtained 12 cases (21$\%$) of Tegner score VI, 32 cases (57$\%$) of score V, 20 cases (35%$\%$ of score IV, 3 (5.3$\%$) cases of score III. Conclusions : Reconstruction of anterior cruciate ligaments can restore stability sufficient to allow sports activity in ACL injured patients, but it’s difficult to achieve 'normal' sports activity. So we will have to solve the reasons of this dissatisfaction at furthermore.

  • PDF

Clinical Results of Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon (슬괵건을 이용한 전방십자인대 재건술의 임상적 결과)

  • Song Eun Kyoo;Lee Keun Bae;Shin Sang Gyoo;Kim Hyun Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • Purpose: To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw, which is newly designed for fixation of graft into femur. Materials and Methods: Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon and LA screw were included in this study. The graft was fixed with LA screw at femoral tunnel and with only bioabsorbable interference screw at tibial tunnel. The mean follow-up period was 28 months. The clinical results were evaluated by physical examination and Lysholm knee score. Widening of bony tunnel and anterior laxity difference compared with normal side by instrumented anterior laxity test with Telos(R) (Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results: The Lysholm knee score improved from 60.0 points preoperatively to 94.0 points at last follow up. On the Lachman test, there were mild (+) instability in 16 cases, moderate (++) in 24,severe (+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at postoperative follow up. On instrumented anterior laxity test with Telos(R), difference between normal and affected knee on 20 lb was 12.9 mm in average preoperatively, and was decreased to 3.1mm at last follow-up. The femoral tunnel was widened from 10.6 mm postoperatively to 12.7 mm (21.1$\%$) at follow up on antero-posterior plane and from 10.7 mm to 12.4 mm (16.5$\%$) on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm (20.7$\%$) on antero-posterior plane and from 9.9mm to 11.7 mm ($18.9\%$) on lateral plane. Complications were: anterior knee crepitus in 17 case, quadriceps muscle atrophy(>3 cm) in 6, penetration of screw over the lateral femoral cortex in 5, saphenous nerve paresthesia in 2.Conclusions: ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixation devices in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel and anterior knee pain

  • PDF

Effect of Intravenous Administration of Tramadol on the Minimum Alveolar Concentration of Isoflurane in Dogs (개에서 트라마돌의 정맥투여가 아이소플루란의 최소폐포농도에 미치는 영향)

  • Seok, Seong-Hoon;Park, Se-Jin;Lee, Seung-Yong;Jin, So-Young;Kim, Young-Ki;Hwang, Jae-Min;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.308-312
    • /
    • 2015
  • This study was aimed to evaluate the effects of tramadol hydrochloride on the minimum alveolar concentration of isoflurane ($MAC_{ISO}$) in dogs. Six healthy, female German shepherd dogs (aged 1-2 years) were used in this study. Anesthesia was induced by mask induction and maintained with isoflurane in oxygen. Mechanical ventilation maintained the end-tidal $CO_2$ partial pressure ($P_{ET}CO_2$) from 35 to 45 mmHg throughout the study. A baseline $MAC_{ISO}$ ($MAC_{ISO}B$) was determined starting 45 minutes after induction of anesthesia by clamping a pedal digit until gross purposeful movement was detected. After $MAC_{ISO}B$ determination, dogs received a tramadol loading dose of 3 mg/kg followed by a continuous rate infusion (CRI) of 2.6 mg/kg/h. The determination of $MAC_{ISO}$ after administration of tramadol ($MAC_{ISO}T$) began 20 min after the start of the CRI. Arterial blood pressure and heart rate were recorded continuously and arterial blood samples for blood gas analysis were collected at the end of the equilibration period. Mean ${\pm}$ SD values for the $MAC_{ISO}B$ and $MAC_{ISO}T$ were $1.33{\pm}0.04%$ and $1.23{\pm}0.04%$, respectively. The $MAC_{ISO}B$ decreased significantly by $7.5{\pm}0.2%$ (P < 0.05) after administration of tramadol. The mean heart rate and arterial blood pressure of six dogs were not changed significantly after tramadol administration. The blood gas levels remained constant during the study. In conclusion, tramadol could significantly reduce $MAC_{ISO}$ without depression of cardiorespiratory function. Thus, the use of tramadol on inhalation anesthesia with isoflurane in dogs can improve the stability of anesthesia and the quality of recovery.