• Title/Summary/Keyword: stability of membrane

Search Result 702, Processing Time 0.031 seconds

Mechanical Stability Evaluation of Thin Film with Spin-coater (스핀코터를 이용한 박막의 기계적 안정성 평가)

  • Kim, Ji Eun;Kim, Jung Hwan;Hong, Seongchul;Cho, HanKu;Ahn, Jinho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.1
    • /
    • pp.6-11
    • /
    • 2016
  • For high volume manufacturing using extreme ultraviolet (EUV) lithography, mask protection from contamination during lithography process must be solved, and EUV pellicle is the strongest solution. Based on the technical requirements of EUV pellicle, EUV pellicle should have large membrane area ($110{\times}140mm^2$) with film transmittance over 90% and mechanical stability. Even though pellicle that satisfies size standard with high transmittance has been reported, its mechanical stability has not been confirmed, nor is there a standard to evaluate the mechanical stability. In this study, we suggest a rather simple method evaluating mechanical stability of pellicle membrane using spin-coater which can emulate the linear accelerated motion. The test conditions were designed by simulating the acceleration distribution inside pellicle membrane through correlating the linear acceleration and centripetal acceleration, which occurs during linear movement and rotation movement, respectively. By these simulation results, we confirmed the possibility of using spin-coater to evaluate the mechanical stability of EUV pellicle.

Dynamic Stability of Liquid in a Spherical Tank Covered with Membrane under Vertical Harmonic Excitation

  • Chiba, Masakatsu;Murase, Ryo;Nambu, Yohsuke;Komatsu, Keiji
    • International Journal of Aerospace System Engineering
    • /
    • v.2 no.2
    • /
    • pp.34-39
    • /
    • 2015
  • Experimental studies were conducted on the liquid sloshing characteristics in a spherical tank covered with a flexible membrane. A spherical acrylic tank with 145.2 mm in radius was used as a test tank, and it was half-filled with water. Silicon membranes with 0.2 mm thickness were used as a test membrane with plane or hemispherical types. The test tank was harmonically excited in a vertical direction by an electro-dynamic exciter. In this case, a parametric instability vibration comes up when the excitation frequency is twice the natural frequency. Parametric instability regions of natural modes were measured for three cases, i.e. liquid surface is free, covered with plane membrane and hemi-spherical membrane.

Development of nano-and meso- inorganic membrances for the environmental applications

  • Yi, Jong-Heop
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.03a
    • /
    • pp.37-59
    • /
    • 2004
  • Advantages : - Multi-functionality of inorganic surface ㆍMetal chelating ligand $\longrightarrow$ metal recovery .Alkylation $\longrightarrow$ hydrophobicity control - Enhanced stability ㆍThermal, mechanical and chemical stability ㆍSeparation in high temperature and pressure (omitted)

  • PDF

Assessment of Immune Parameters of the Wild Pacific Oyster (Crassostrea gigas) using a Flow Cytometry and Neutral Red Retention Assay (유세포 분석기와 Neutral Red Retention Assay를 이용한 자연산 참굴(Crassostrea gigas)의 면역력 측정)

  • Hong, Hyun-Ki;Kang, Hyun-Sil;Kim, Young-Ok;Choi, Kwang-Sik
    • Ocean and Polar Research
    • /
    • v.34 no.2
    • /
    • pp.137-149
    • /
    • 2012
  • Hemocyte parameters of the wild Pacific oyster Crassostrea gigas inhabiting intertidal zones in small bays (Gwangyang and Jinhae Bay) on the southern coast of Korea were evaluated using flow cytometry and neutral red retention (NRR) assay. Morphological features, cell count, mortality, DNA damage, phagocytosis, and lysosomal membrane stability of hemocytes were analyzed. Three types of hemocytes were identified in the oyster hemolymph: granulocytes, hyalinocytes, and blast-like cells. Immune related functions of hemocyte including phagocytosis and lysosomal membrane stability were significantly different among the study areas (P<0.05), while cell count, mortality, and DNA damage of hemocytes were not significantly different. In Gwangyang Bay, phagocytosis of granulocytes and lysosomal membrane stability of oyster hemocytes inhabiting inside bay were significantly lower than those of oyster hemocytes in outside bay (P<0.05), indicating that oysters in inside bay of Gwangyang were relatively suppressed the immunological function in hemocytes. Contrary to Gwangyang Bay, immune parameters of oyster hemocytes in Jinhae Bay not showed the difference between sampling sites. In conclusion, flow cytometry and NRR assay using oyster hemocyte has a powerful tool to investigate the cell level in a short time due to no-preprocessing of material.

Study on Commercially Available Anion Exchange Membrane for Alkaline Water Eectrolysis (알칼리 수전해를 위한 상용 음이온교환막에 관한 연구)

  • Park, Joo-Wang;Ryu, Cheol-Hwi;Hwang, Gab-Jin
    • Membrane Journal
    • /
    • v.31 no.4
    • /
    • pp.275-281
    • /
    • 2021
  • To evaluate the possibility as a separator in alkaline water electrolysis, the thermal stability, ion conductivity and durability of 5 commercially available anion exchange membranes were tested. The thermal stability of FAAM-PK-75 and FAAM-40 membrane analyzed by thermo-gravimetric analysis (TGA) showed good performance compared to the other three types of AEM, AHO, and AHA membrane. The ion conductivity of AEM membrane measured in 7 M KOH solution at 25℃ and 80℃ had a higher value of about 4~17 times compared to the other membranes. The durability of FAAM-PK-75 tested in 7 M KOH solution at 25℃ was high compared to the other membranes.

A Review of Strategies to Improve the Stability of Carbon-supported PtNi Octahedral for Cathode Electrocatalysts in Polymer Electrolyte Membrane Fuel Cells

  • In Gyeom Kim;Sung Jong Yoo;Jin Young Kim;Hyun S. Park;So Young Lee;Bora Seo;Kwan-Young Lee;Jong Hyun Jang;Hee-Young Park
    • Journal of Electrochemical Science and Technology
    • /
    • v.15 no.1
    • /
    • pp.96-110
    • /
    • 2024
  • Polymer electrolyte membrane fuel cells (PEMFCs) are green energy conversion devices, for which commercial markets have been established, owing to their application in fuel cell vehicles (FCVs). Development of cathode electrocatalysts, replacing commercial Pt/C, plays a crucial role in factors such as cost reduction, high performance, and durability in FCVs. PtNi octahedral catalysts are promising for oxygen reduction reactions owing to their significantly higher mass activity (10-15 times) than that of Pt/C; however, their application in membrane electrode assemblies (MEAs) is challenged by their low stability. To overcome this durability issue, various approaches, such as third-metal doping, composition control, halide treatment, formation of a Pt layer, annealing treatment, and size control, have been explored and have shown promising improvements in stability in rotating disk electrode (RDE) testing. In this review, we aimed to compare the features of each strategy in terms of enhancing stability by introducing a stability improvement factor for a direct and reasonable comparison. The limitations of each strategy for enhancing stability of PtNi octahedral are also described. This review can serve as a valuable guide for the development of strategies to enhance the durability of octahedral PtNi.

Separation of Hydrogen-Nitrogen Gas Mixture by PTMSP/PDMS-PEI Composite Membrane

  • Lee, Hyun-Kyung;Kang, Tae-Beom
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2004.05a
    • /
    • pp.148-151
    • /
    • 2004
  • The development of the gas separation processes using polymeric membranes has attracted a great deal of interest during the last two decades. Membrane in this application has to offer an excellent thermal stability, chemical/solvent resistance, and mechanical strength under operating conditions.(omitted)

  • PDF

Development of Pore-filled Polymer Electrolyte Membranes for Flexible Electrochromic Devices (유연한 전기변색 소자를 위한 세공충진 고분자 전해질 멤브레인의 개발)

  • Park, Hyeon-Jung;Lee, Ji-Hyeon;Kang, Moon-Sung
    • Membrane Journal
    • /
    • v.31 no.5
    • /
    • pp.333-342
    • /
    • 2021
  • A flexible electrochromic device (ECD) is a promising technology that is expected to be applied in various fields such as smart windows. Polymer electrolyte is an important component that determines the bleaching-coloration performance and physical stability of flexible ECDs. In this study, a pore-filled polymer electrolyte membrane (PFPEM) with excellent dimensional stability was developed to effectively fabricate flexible ECDs and improve durability. Polyvinyl acetate, which has excellent adhesion, and polyethylene glycol, which can improve ionic conductivity, were filled in the pores of a porous substrate made of polyethylene, which is inexpensive and has excellent physical and chemical stability. The optimal lithium salt (LiTFSI) content of the prepared PFPEM was determined at about 27 wt%, and it was confirmed to possess excellent dimensional stability, adhesive strength, and ion conductivity close to that of conventional polymer electrolytes. Although the visible light transmittance was lowered by the use of the porous substrate, it was expected to act as an advantage in the colored state.

The Effects of Dietary Proteins on Hepatic Histological Changes and Membrane Stability in Chemically Induced Rat Hepatocarcinogenesis (화학적으로 유도한 랫드 간세포 암화과정에서 단백질 식이가 간의 조직학적 변화와 생체막 안정도에 미치는 영향)

  • 박경애;김현덕;최혜미
    • Journal of Nutrition and Health
    • /
    • v.34 no.8
    • /
    • pp.833-842
    • /
    • 2001
  • The purpose of this study is to determine the effect of dietary proteins and fats on the hepatic histological changes, membrane stability, and drug-metabolizing enzyme activities during chemically induced rat hepatocarcinogenesis. Weanling Sprague-Dawley rats were fed the diet containing 20% casein or soy protein isolate and 15% perilla or corn oil for 10 weeks. Hepatocarcinogensis was initiated with diethylnitrosamine(DEN), and the rats were fed diets containing 0.02% 2-acetylaminofluorene(AAF) followed by 0.05% phenobarbital (PB). The scores of histological changes were decreased in treated rats fed soy protein diet compared to those find casein diet. Liver weights were significantly increased by AAF and PB treatment in rats fed casein diets in both oil groups. Glucose 6-phosphatase(G6Pase) activities, an index of membrane stability, were significantly reduced by AAF and PB treatment in rats find casein diets, and were lower in casein diet compared to soy protein diet groups. Especially, the activities were the highest in the rats fed soy protein-perilla oil diet. Lipid peroxide values also were increased by AAF and PB treatment in rats fed casein diet. Aniline hydroxylase activities were not influenced by protein and fat sources. Glutathione-dependent enzyme activities were increased by AAF and PB treatment. Linoleic and arachidonic acid content were increased in rats fed corn oil diet, and linolenic and eicosapentaenoic acid contents were increased in rats fed perilla oil diet. Our results suggest that soy protein isolate inhibit the abnormal histological changes in liver, possibly by maintaining the membrane stability during chemically induced rat hepatocarcinogenesis. Soy protein may be protective against the hepatocarcinogenesis induced by chemical carcinogen.

  • PDF

Ionic Liquid as a solvent and Long-Term Separation Performance in Polymer/Silver Salt Complex Membrane

  • Kang, Sang-Wook;Kim, Jong-Hak;Char, Kook-Heon;Kang, Yong-Soo
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.307-307
    • /
    • 2006
  • The reduction behavior of silver ions to silver nanoparticles is an important research topic in polymer/silver salt complex membranes for facilitated olefin transport, because it has a significant effect on the long-term stability of membrane performance. In this study, the effects of solvent on the formation of silver nanoparticles and long-term membrane performance in polymer/silver salt complex membrane were investigated. This effect was assessed for the complexes of poly(N-vinyl pyrrolidone) $(PVP)/AgBF_{4}$ with the use of ionic liquid (IL), acetonitrile (ACN) and water as a solvent. Membrane performance test shows that long-term stability is strongly dependent on the kind of solvent and arranged: IL > ACN >> water.

  • PDF