• 제목/요약/키워드: square wave anodic stripping voltammetry

검색결과 25건 처리시간 0.023초

DEVELOPMENT OF ANODIC STRIPPING VOLTAMMETRY FOR THE DETERMINATION OF PALLADIUM IN HIGH LEVEL NUCLEAR WASTE

  • Bhardwaj, T.K.;Sharma, H.S.;Jain, P.C.;Aggarwal, S.K.
    • Nuclear Engineering and Technology
    • /
    • 제44권8호
    • /
    • pp.939-944
    • /
    • 2012
  • Deposition potential, deposition time, square wave frequency, rotation speed of the rotating disc electrode, and palladium concentration were studied on a Glassy Carbon Electrode (GCE) in 0.01M HCl for the determination of palladium in High Level Nuclear Waste (HLNW) by anodic stripping voltammetry. Experimental conditions were optimized for the determination of palladium at two different, $10^{-8}$ and $10^{-7}M$, levels. Error and standard deviation of this method were under 1% for all palladium standard solutions. The developed technique was successfully applied as a subsidiary method for the determination of palladium in simulated high level nuclear waste with very good precision and high accuracy (under 1 % error and standard deviation).

Assay of Dinitrotoluene on a Contaminated Soil Sample with an Anodic Stripping Peak Current

  • Ly, Suw-Young;Lee, Chang-Hyun;Jung, Young-Sam
    • 한국환경과학회지
    • /
    • 제15권11호
    • /
    • pp.997-1002
    • /
    • 2006
  • This report presents a voltammetric assay of dinitrotoluene using a DNA immobilized onto a carbon nanotube paste electrode (PE). The cyclic voltammetry (CV) and square wave (SW) stripping voltammetry parameters of the optimized conditions were obtained. An anodic peak current appeared at 0.3 V (versus Ag/AgCl) in a 0.1-M $NH_4H_2PO_4$ electrolyte solution. The detection limit was found to be $0.6ngL^{-1}$(S/N = 10), within a deposition time of 100 sec.

Determination of Heavy Metals in Sea Salt Using Anodic Stripping Voltammetry

  • Kim, Yong Hoon;Kim, Giyoung
    • 산업식품공학
    • /
    • 제21권2호
    • /
    • pp.180-186
    • /
    • 2017
  • Salt, as food, is the most essential element for human survival due to its significant physiological functions. Here, we report the simultaneous detection of Pb and Cd in sea salt by square wave anodic stripping voltammetry (SWASV). Stripping voltammetric measurements were conducted using a manufactured rotating disk electrode system (MRDES). The detection limit was $3.6{\pm}0.18{\mu}gL^{-1}$ for Pb and $3.9{\pm}0.37{\mu}gL^{-1}$ Cd in NaCl solution. When the pH increased from 5.5 to 8.5, the peak currents of Pb and Cd decreased. At a pH of 8.3, the ratio of the current drop compared with that at a pH of 5.5 was 0.6 for Pb and 0.73 for Cd. The concentrations corrected by the current drop are in agreement with the concentrations obtained with ICP (inductively coupled plasma). This system demonstrates the reliable detection of heavy metals in aqueous media and, at a high $Na^+$ concentration, the successful application for the determination of Pb and Cd in sea salts.

Analysis of Cu in Mezcal Commercial Samples using Square Wave Anodic Stripping Voltammetry

  • Salinas, Gerardo;Ibanez, Jorge G.;Vasquez-Medrano, Ruben;Frontana-Uribe, Bernardo A.
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권4호
    • /
    • pp.276-281
    • /
    • 2018
  • High concentration of copper in mezcal, a representative Mexican spirituous alcoholic beverage, is a serious problem due to the damage that it may cause to human health. A cyclic voltammetry and square wave anodic stripping voltammetry study of copper (II) in three commercial mezcal samples based on glassy carbon electrode response was undertaken. The analysis was developed using a simulated matrix solution ($EtOH/H_2O$ (1:1), 0.1 M $LiClO_4$ and AcOH/AcONa 0.05 M/0.008 M), with Cu (II) concentrations in the range 0 - 1 ppm. Direct electrochemical analysis of mezcal samples was complicated by the presence of different organic compounds in the matrix. The analytical signal of Cu (II) in the spirituous was notably improved and the interferences caused by organic compounds were minimized, by diluting the mezcal samples 10% with $EtOH/H_2O$ (1:1) solution. An efficient quantification of Cu (II) was obtained from the calibration curve by the SWASV and using the internal standard method (Cd (II)) in commercial samples (1.2-6.7 ppm); the results were correlated satisfactorily with the values obtained by AAS.

Integrated Microdisk Gold Electrode Modified with Metal-porphyrin and Metal-phthalocyanines for Nitric Oxide Determination in Biological Media

  • Kim, Il-Kwang;Bae, Hyun-Ok;Oh, Gi-Soo;Chung, Hun-Taeg;Kim, Young-Jin;Chun, Hyun-Ja
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권11호
    • /
    • pp.1579-1584
    • /
    • 2003
  • An integrated gold microdisk electrode was constructed and modified with metal-porphyrin or metal-phthalocyanines for NO determination in biological media. Microanalysis of NO using square wave anodic stripping voltammetry in $1\;{\times}\;10^{-2}$ M $HClO_4$ was optimal when the accumulation potential was 0.1 V, frequency 100 Hz, and the scan rate was 200 mV/s. When the electrode was modified with metal-porphyrin or metal-phthalocyanines, the anodic peak currents of NO increased due to the catalytic oxidation of NO. In case of Fe(II)-phthalocyanine modified electrode, the peak currents remarkably increased and the sensitivity was high. The calibration curve had good linearity in the range from $3.6\;{\times}\;10^{-5}$ M to $7.2\;{\times}\;10^{-7}$ M, and the detection limit was $5.7\;{\times}\;10^{-7}$ M. For the structural stability and increased sensitivity, Fe(II)-phthalocyanine modified gold microdisk electrode coated with Nafion was applied to determination of NO released from cultured macrophase.

국내산(國內産) 명일엽(明日葉)의 부위별 게르마늄 함량(含量) (Germanium(IV) Content in the Korean Angelica keiskei Koidz)

  • 정승일;한완수
    • 한국약용작물학회지
    • /
    • 제7권1호
    • /
    • pp.11-15
    • /
    • 1999
  • 국내에서 재배 수확되는 명일엽에 지역별, 부위별로 게르마늄 함량을 네모파 산화전극 벗김전압 전류법을 이용하여 조사한 결과 재배된 지역에 따라 게르마늄의 함량이 공시재료간 잎은 3.8배 정도, 줄기는 5배 정도였다. 명일옆(明日葉)의 채취부위별 게르마늄 함량은 잎부분에서 386ppm로 가장 높았으며 줄기에서 29ppm으로 13.3배 잎에서 더 높았다.

  • PDF

DNA 고정 탄소나노튜브 페이스트전극의 물고기 세포속 테트라싸이클린에 정량 (Measuring Oxytetracycline Using a Simple Prepared DNA Immobilized on a Carbon Nanotube Paste Electrode in Fish Tissue)

  • 이수영;이장현;정영삼
    • 대한화학회지
    • /
    • 제51권5호
    • /
    • pp.412-417
    • /
    • 2007
  • DNA를 고정한 탄소나노튜브 페이스트 전극으로 옥시테트라싸이클린 항생제의 분석조건을 연구하였다. 사각 파형 벗김 전압전류법과 순환 전압 전류법을 사용하여 최적조건에서 1-10 ngL?1의 정량 가능 범위에 도달하였다. 벗김법 0.1 mgL?1 농도에서 15번 반복 측정하여 0.068%의 상대표준편차였으며, 벗김법 최적 분석 조건에서 0.4 ngL?1의 검출 한계를 얻었다. 개발된 결과를 양식어류의 세포에서 응용하였다.

Electrochemical Detection of Pesticide in Living Plant and Fish Brain Cell

  • Lee, Chang-Hyun;Ly, Suw-Young
    • 한국환경과학회지
    • /
    • 제19권8호
    • /
    • pp.941-949
    • /
    • 2010
  • The three electrode system was used to detect the pesticide fenitrothion ($C_9H_{12}NO_5PS$. MW=277.24) using cyclic voltammetry (CV) and square wave anodic stripping voltammetry (SWASV). The working electrode was mercury immobilized on a carbon nanotube paste electrode (Hg-CNTPE). At the optimized condition, the limit of detection (LoD) was 0.6 ppt ($2.16{\times}10^{-12}\;M$), and the relative standard deviation was 0.035% (n=15). And there is more sensitive in detecting fenitrothion than common type carbon nanotube paste electrode. When it was implanted into the brain of live fish (carp), the existence of fenitrothion was measured without any destruction or damage of tissue.

Antibiotics Assay of Doxycycline in Food System using Stripping Voltammetry

  • Ly, Suw Young;Lee, Chang Hyun
    • 한국응용과학기술학회지
    • /
    • 제33권4호
    • /
    • pp.726-733
    • /
    • 2016
  • A voltammetric analysis of doxycycline was developed using DNA immobilized onto a carbon nanotube paste electrode (PE). An anodic peak current was indicated at 0.2 V (versus Ag/AgCl) in a 0.1M $NH_4H_2PO_4$ electrolyte solution. The linear working range of the cyclic and square wave stripping voltammetry was obtained to $1-27ngL^{-1}$ with an accumulation time of 800 s. Final analytical parameters were optimized to be as follows: amplitude, 0.35 V; frequency, 500 Hz; and pH, 5.43. Here detection limit was found to be $0.45ngL^{-1}$, this result can be applied in foods systems and in the biological diagnostics

Detection of Toxic Heavy Metal, Co(II) Trace via Voltammetry with Semiconductor Microelectrodes

  • Ly, Suw Young;Lee, Chang Hyun;Koo, Jae Mo
    • Toxicological Research
    • /
    • 제33권2호
    • /
    • pp.135-140
    • /
    • 2017
  • The cobalt (Co(II)) ion is a main component of alloys and considered to be carcinogenic, especially due to the carcinogenic and toxicological effects in the aquatic environment. The toxic trace of the Co(II) detection was conducted using the infrared photodiode electrode (IPDE) using a working electrode, via the cyclic and square-wave anodic stripping voltammetry. The results indicated a sensitive oxidation peak current of Co(II) on the IPDE. Under the optimal conditions, the common-type glassy carbon, the metal platinum, the carbon paste, and the carbon fiber microelectrode were compared with the IPDE in the electrolyte using the standard Co(II). The IPDE was found to be far superior to the others.