• Title/Summary/Keyword: square tube

Search Result 325, Processing Time 0.022 seconds

Compressive performances of concrete filled Square CFRP-Steel Tubes (S-CFRP-CFST)

  • Wang, Qingli;Shao, Yongbo
    • Steel and Composite Structures
    • /
    • v.16 no.5
    • /
    • pp.455-480
    • /
    • 2014
  • Sixteen concrete filled square CFRP-steel tubular (S-CFRP-CFST) stub columns under axial compression were experimentally investigated. The experimental results showed that the failure mode of the specimens is strength loss of the materials, and the confined concrete has good plasticity due to confinement of the CFRP-steel composite tube. The steel tube and CFRP can work concurrently. The load versus longitudinal strain curves of the specimens can be divided into 3 stages, i.e., elastic stage, elasto-plastic stage and softening stage. Analysis based on finite element method showed that the longitudinal stress of the steel tube keeps almost constant along axial direction, and the transverse stress at the corner of the concrete is the maximum. The confinement effect of the outer tube to the concrete is mainly focused on the corner. The confinements along the side of the cross-section and the height of the specimen are both non-uniform. The adhesive strength has little effect both on the load versus longitudinal strain curves and on the confinement force versus longitudinal strain curves. With the increasing of the initial stress in the steel tube, the load carrying capacity, the stiffness and the peak value of the average confinement force are all reduced. Equation for calculating the load carrying capacity of the composite stub columns is presented, and the estimated results agree well with the experimental results.

Shear behavior of concrete-encased square concrete-filled steel tube members: Experiments and strength prediction

  • Yang, Yong;Chen, Xin;Xue, Yicong;Yu, Yunlong;Zhang, Chaorui
    • Steel and Composite Structures
    • /
    • v.38 no.4
    • /
    • pp.431-445
    • /
    • 2021
  • This paper presents experiments and theoretical analysis on shear behavior of eight concrete-encased square concrete-filled steel tube (CECFST) specimens and three traditional reinforced concrete (RC) specimens. A total of 11 specimens with the test parameters including the shear span-to-depth ratio, steel tube size and studs arrangement were tested to explore the shear performance of CECFST specimens. The failure mode, shear capacity and displacement ductility were thoroughly evaluated. The test results indicated that all the test specimens failed in shear, and the CECFST specimens enhanced by the interior CFST core exhibited higher shear capacity and better ductility performance than that of the RC specimens. When the other parameters were the same, the larger steel tube size, the smaller shear span-to-depth ratio and the existence of studs could lead to the more satisfactory shear behavior. Then, based on the compatible truss-arch model, a set of formulas were developed to analytically predict the shear strength of the CECFST members by considering the compatibility of deformation between the truss part, arch part and the steel tube. Compared with the calculated results based on several current design specifications, the proposed formulas could get more accurate prediction.

Custom-Made T-Tube Designed by 3-D Reconstruction Technique, a Preliminary Study (삼차원 재건 기술을 이용한 맞춤형 몽고메리 T-Tube의 제작에 관한 예비 연구)

  • Yoo, Young-Sam
    • Korean Journal of Bronchoesophagology
    • /
    • v.16 no.2
    • /
    • pp.131-137
    • /
    • 2010
  • Background: Montgomery T-tube is widely used to maintain airway in many cases. Market-available tubes are not always fit to the trachea of each patient and need some modification such as trimming. Complications do happen in prolonged use like tracheostomy tubes. To overcome above limitations, we designed custom-made T-tube using CT data with the aid of 3D reconstruction software. Material and Method: Boundaries were extracted from neck CT data of normal person and processed by surface rendering methods. Real laryngotracheal model and tracheal inner surface-mimicking tube model were made with plaster and rubber. The main tube was designed by accumulation of circles or simple closed curves made from boundaries. Stomal tube was made by accumulation of squares due to limitation of software. Measurement data of tracheal lumen were used to custom-made T-tubes. Tracheal lumen residing portion (vertical limb) was made like circular cylinder or simple closed curved cylinder. Stomal portion (horizontal limb) was designed like square cylinder. Results: Custom made T-tube with cylindric vertical limb and horizontal limb of square cylinder was designed. Conclusion: CT data was helpful in making custom made T-tube with 3D reconstruction technique. If suitable materials are available, commercial T-tube can be printed out from 3D printers.

  • PDF

Fluidelastic Instability of Flexible Cylinders in Tube Bundle Subjected to Cross Air-flow (공기-횡 유동장에 놓인 유연성 실린더 관군의 유체탄성 불안정)

  • Sim, Woo-Gun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.6 s.123
    • /
    • pp.498-506
    • /
    • 2007
  • Using wind tunnel, experimental approaches were employed to investigate fluidelastic instability of tube bundles, subjected to uniform cross flow. There are several flow-induced vibration excitation mechanisms, such as fluidelastic instability, periodic wake shedding resonance, turbulence-induced excitation and acoustic resonance, which could cause excessive vibration in shell-and tube heat exchanges. Fluidelastic is the most important vibration excitation mechanism for heat exchanger tube bundles subjected to cross flow. The system comprised of cantilevered flexible cylinder(s) and rigid cylinders of normal square array, In order to see the characteristics of flow in tube bundles, particle image velocimetry was used. From a practical design point of view, Fluidelastic instability may be expressed simply in terms of dimensionless flow velocity and dimensionless mass-damping. The threshold flow velocity for dynamic instability of cylinder rows is evaluated and the data for design guideline is proposed for the tube bundles of normal square array.

P-M Relations of Slender Welded Built-up Square CFT Column under Eccentric Loads (시공성을 향상시킨 용접조립 각형 CFT 편심 장주의 P-M 관계)

  • Lee, Seong-Hui;Choi, Sung-Mo;Kim, Young-Ho
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.2
    • /
    • pp.23-31
    • /
    • 2015
  • CFST columns are structurally superior because the concrete inside the steel tubes prevents local buckling at the tubes and the tubes confine the concrete. And, the thickness of steel tube in CFST column has been thinner with development of high-strengh steel. The thinner the steel tube of a square CFST column is, the more local buckling is likely to occur. For this reason, we developed welded built-up square steel tube with stiffeners which are placed at the center of the tube width acts as an anchor. In this study, we conduct experimental test for three specimens of the 4m long span welded built-up square CFT column with parameters of L/D and D/t. And, the test results were compared with the analysis results by M-${\phi}$-P Program.

An Experimental Study on the Impact Energy Absorption Mechanism of CFRP/Al Compound Square Tube (CFRP/Al 혼성 사각부재의 충격에너지 흡수 메카니즘의 실험적 고찰)

  • Hwang, Woo Chae;Cha, Cheon Seok;Yang, Yong Jun;Jung, Jong An;Yang, In Young
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.12-17
    • /
    • 2015
  • In this study, the collapse characteristic of CFRP/Al compound square tube was investigated experimentally. The conclusions are as follows; The impact collapse characteristic of CFRP/Al compound square tube was found to be the most superior stacking conditions $[90^{\circ}]_8$. It showed that a very stable collapse mode was crushing. In the member with $[0_2{^{\circ}}/90_2{^{\circ}}]_s$ and $[90_2{^{\circ}}/0_2{^{\circ}}]_s$, stacking conditions, $0^{\circ}$ fibers were splayed to the external by laminar bending, while the $90^{\circ}$ fibers were held between the folds of the aluminum member by laminar bending, local buckling and transverse crack. In the member with $[45_2{^{\circ}}/45_2{^{\circ}}]_s$ stacking conditions, fibers were held between the folds of the aluminum member by local buckling and transverse crack.

Structural characteristics of welded built-up square CFT column-to-beam connections with external diaphragms

  • Lee, Seong-Hui;Yang, Il-Seung;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • v.10 no.3
    • /
    • pp.261-279
    • /
    • 2010
  • Generally, a box tube, which is used for an existing square CFT structure, is made by welding four plates. The manufacturing efficiency of this steel tube is poor, and it also needs special welding technology to weld its internal diaphragm and the through diaphragm. Therefore, an interior-anchor-type square steel tube was developed using the method of cold-forming thin plates to prevent welding of the stress concentration position, and to maximize the section efficiency. And, considering of the flow of beam flange load, the efficiency of erection and the weldability of the diaphragm to thin walled steel column, the external diaphragm connection was selected as the suitable type for the welded built-up square CFT column to beam connection. And, an analytical study and tests were conducted to evaluate the structural performance of the suggested connection details and to verify the suggested equations for the connection details. Through this study, the composite effect of the internal anchor to concrete, the resistance and stress distribution of the connections before and after the existing column is welded to the beam, the effective location of welding in connection were analyzed.

An Experimental Study on Structural Performance of Welded Built-up Square CFT Stub Columns (용접조립 각형 CFT 단주의 구조특성에 관한 실험적 연구)

  • Lee, Seong Hui;Choi, Young Hwan;Yom, Kyong Soo;Kim, Jin Ho;Choi, Sung Mo
    • Journal of Korean Society of Steel Construction
    • /
    • v.20 no.5
    • /
    • pp.645-653
    • /
    • 2008
  • Welded built-up square tubes are manufactured by flare welding at the center of the column width for cold-formed L-shaped four-piece plates and improved composite effect of concrete and steel by vertical inner anchor. Also, the axial resistance of concrete is increased by the thinness of the steel column, and the composite effect of concrete and steel prevents the steel column from local buckling. In this study, we introduced a manufacturing method of built-up square column steel square concrete-filled tubular column with vertical inner anchor and superior structural performance of the square stub column verified by the structural test for 15 specimens with parameters of shape of tube (built-up square tube, general steel tube), width over thickness of the steel tube (B/t=50, 58, 67) and the strength of concrete (f'c=10MPa, 50MPa).

An Experimental Study on Wakes behind a Circular and a Square Cylinder in a Horizontal Circular Tube (수평원통관 내에서 원형 및 정사각 실린더의 후류에 관한 실험적 연구)

  • Chang, Tae-Hyun;Lee, Myung Jae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.6 no.3
    • /
    • pp.253-259
    • /
    • 2003
  • An experimental study was performed for turbulent flow behind a circular and a square cylinder by using 2-D PIV(Particle Image Velocimetry) technique in a cylindrical tube. The Reynolds number investigated were 10,000, 30,000 and 50,000. The measuring system consists of CCD camera. Ar-ion laser, image grabber and a host computer. The mean velocity vector, time mean axial velocity, turbulent intensity and Reynolds shear stress were measured along the test tube. The results are compared each other for the circular and the square cylinder.

  • PDF