• 제목/요약/키워드: square tube

검색결과 325건 처리시간 0.027초

Image Restoration in Dual Energy Digital Radiography using Wiener Filtering Method

  • Min, Byoung-Goo;Park, Kwang-Suk
    • 대한의용생체공학회:의공학회지
    • /
    • 제8권2호
    • /
    • pp.171-176
    • /
    • 1987
  • Wiener filtering method was applied to the dual energy imaging procedure in digital radiography(D.R.). A linear scanning photodiode arrays with 1024 elements(0.6mm H 1.3mm pixel size) were used to obtain chest images in 0.7 sec. For high energy image acquisition, X-ray tube was set at 140KVp, 100mA with a rare-earth phosphor screen. Low energy image was obtained with X-ray tube setting at 70KVp, 150mA. These measured dual energy images are represented in the vector matrix notation as a linear discrete model including the additive random noise. Then, the object images are restored in the minimum mean square error sense using Wiener filtering method in the transformed domain. These restored high and low energy images are used for computation of the basis image decomposition. Then the basis images are linearly combined to produce bone or tissue selective images. Using this process, we could improve the signal to noise ratio characteristics in the material selective images.

  • PDF

Spiral Tube 내에서의 3차원 유동 해석 (A numerical study of 3-D flows in spiral tubes with square cross-section)

  • 김성원;허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1998년도 추계 학술대회논문집
    • /
    • pp.62-69
    • /
    • 1998
  • Spiral tube heat exchangers can find numerous applications in many engineering field. Flow in spital tubes is interest to engineers due to occurrence of secondary flow which enhances the cross-sectional mixing and the heat transfer rate. In the present study, an incompressible viscous 3-D flow in spiral tubes with rectangular cross-section of various torsion rate and Reynolds number is studied by using a finite volume method. It is shown that the axial velocity profile is affected by the secondary flow motion. Because there is some difference from correlation proposed by Hur et al., a lot of analysis and arrangement of experimental results are needed. This study showed the results of variation of hydrodynamic entry length for torsion and Re numbers.

  • PDF

원음장에서의 충격성 소음전파에 관한 실험적 연구 (An Experimental Study on the Propagation of Impulse Noise in the Far Sound Field)

  • 송화영;제현수;이주원;이성태;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.852-855
    • /
    • 2004
  • This experimental study describes the propagation characteristics of the impulse noise emitted from the exit of a straight pipe attached to the open end of a simple shock tube. The sound pressure level and directivity of the impulse noise propagating from the exit of pipe with several different diameters are measured in the far sound fold for the range of the incident shock wave Mach number between 1.07 and 1.26. The experimental results showed that the peak values of impulse noises had a strong dependance on the exit diameter of a pipe and the shock wave Mach number. The impulse noise had the directivity propagating toward to the pipe axis and the characteristics of inverse square law of propagation distance. Moreover, it was shown that the one-third octave band SPL of impulse noise was almost constant regardless of the frequency band.

  • PDF

Nonlinear identification of Bouc-Wen hysteretic parameters using improved experience-based learning algorithm

  • Luo, Weili;Zheng, Tongyi;Tong, Huawei;Zhou, Yun;Lu, Zhongrong
    • Structural Engineering and Mechanics
    • /
    • 제76권1호
    • /
    • pp.101-114
    • /
    • 2020
  • In this paper, an improved experience-based learning algorithm (EBL), termed as IEBL, is proposed to solve the nonlinear hysteretic parameter identification problem with Bouc-Wen model. A quasi-opposition-based learning mechanism and new updating equations are introduced to improve both the exploration and exploitation abilities of the algorithm. Numerical studies on a single-degree-of-freedom system without/with viscous damping are conducted to investigate the efficiency and robustness of the proposed algorithm. A laboratory test of seven lead-filled steel tube dampers is presented and their hysteretic parameters are also successfully identified with normalized mean square error values less than 2.97%. Both numerical and laboratory results confirm that, in comparison with EBL, CMFOA, SSA, and Jaya, the IEBL is superior in nonlinear hysteretic parameter identification in terms of convergence and accuracy even under measurement noise.

쉐도우마스크의 열변형 해석 -온도분포 (Thermal Deformation Analysis of Shadow Mask : Temperature Distribution)

  • 김현규;천현태;임세영
    • 대한기계학회논문집
    • /
    • 제17권10호
    • /
    • pp.2574-2581
    • /
    • 1993
  • A Shadow mask in C. R. T. (Cathod Ray Tube) undergoes a temperature increase due to impinging electron beams emitted from guns, and thermal deformation from such temperature rise may cause the electron beams to island on the panel, and thus give rise to depolarization. Hence the analysis of temperature distribution for a shadow mask is an important procedure for designing the shadow mask. In this paper, we are concerned with nonlinear finite element analysis of the temperature distribution on a shadow mask. First of all, we replace shadow mask, containing numerous apertures of a slit type, by an orthotropic shell without apertures, and calculate the apparent thermal conductivities. Because of thermal radiation, which is one of the major heat transfer mechanism for shadow masks, the resulting finite element equation is nonlinear and solved by the Newton method. Finally numerical examples are illustrated for a 21" FST(Full Square Tube) shadow mask, and followed by discussion.sion.

증기발생기 세관의 중심좌표추출에 대한 연구 (Study on Extraction of the Center Point of Steam Generator Tubes)

  • 조재완;김창회;서용칠;최영수;김승호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 하계종합학술대회 논문집(4)
    • /
    • pp.263-266
    • /
    • 2002
  • This paper describes extraction procedure for the center coordinates of steam generator tubes of Youngkwang NPP #6, which are arrayed in triangular patterns. Steam generator tube images taken with wide field-of-view lens and low-light lamp mounted on a ccd camera tend to have low contrast, because steam generator is sealed and poorly illuminated. The extraction procedures consists of two steps. The first step is to process the region with superior contrast in entire image of steam generator tubes and to extract the center points. Using the extracted coordinates in the first step and the geometrical array characteristics of tubes lined up in regular triangle forms, the central points of the rest region with low contrast are estimated. The straight lines from center point of a tube to neighbour points in horizontal and 60, 120$^{\circ}$ degree directions are derived. The intersections of straight line In horizontal direction and slant line in regular triangle direction are selected as the center coordinates of steam generator tubes. The Chi-square interpolation method is used to determine the line's coefficients in horizontal and regular triangle direction.

  • PDF

Condensation Heat Transfer Correlation for Smooth Tubes in Annular Flow Regime

  • Han Dong-Hyouck;Moon C.;Park C.;Lee Kyu-Jung
    • Journal of Mechanical Science and Technology
    • /
    • 제20권8호
    • /
    • pp.1275-1283
    • /
    • 2006
  • Condensation heat transfer coefficients in a 7.92 mm inside diameter copper smooth tube were obtained experimentally for R22, R134a, and R410A. Working conditions were in the range of $30-40^{\circ}C$ condensation temperature, $95-410 kg/m^2s$ mass flux, and 0.15-0.85 vapor quality. The experimental data were compared with the eight existing correlations for an annular flow regime. Based on the heat-momentum analogy, a condensation heat transfer coefficients correlation for the annular flow regime was developed. The Breber et al. flow regime map was used to discern flow pattern and the Muller-Steinhagen & Heck pressure drop correlation was used for the term of the proposed correlation. The proposed correlation provided the best predicted performance compared to the eight existing correlations and its root mean square deviation was less than 8.7%.

선회가 있는 수평원통관에서 원형실린더의 후류에 관한 실험적 연구 (An Experimental Study on the Wake behind a Round Cylinder with Swirling Flow in the Horizontal Circular Tube)

  • 장태현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권4호
    • /
    • pp.417-425
    • /
    • 2005
  • An experimental study is performed on the turbulent swirling flow behind a crcular cylinder using 2-D PIV technique. The Reynolds numbers investigated are 10.000, 15,000. 20.000 and 25.000. The mean velocity vector, time mean axial velocity, turbulence intensity, kinetic energy and Reynolds shear stress behind the cylinder are measured before and behind the cylinder along the test tube. A comparison is included without swirling flow behind a circular and square cylinder. The recirculation zones are shown unsymmetric profiles.

탄소 섬유관으로 구속된 콘크리트 부재의 신뢰성 해석 (Reliability Analysis of Concrete Filled Carbon Composite Tube)

  • 김희철;이경훈;홍원기;이영학;엄철환
    • 한국지진공학회논문집
    • /
    • 제10권5호
    • /
    • pp.1-9
    • /
    • 2006
  • 본 논문에서는 탄소섬유관으로 구속된 무근 콘크리트 원형 및 각형 기둥에 대한 축하중 및 횡하중 재하 실험을 수행하고, 실험결과를 바탕으로 하여 몬테카를로 해석을 이용한 신뢰성 해석을 수행함으로써 탄소섬유관으로 구속된 무근 콘크리트 원형 및 각형 기둥과 탄소섬유관으로 구속된 철근 콘크리트 원형 및 각형 기둥의 두 가지 경우에 대한 강도저감계수를 예측하였다. 해석 결과, 무근의 경우에는 강도저감계수가 0.7로 예측되었고, 철근이 삽입된 경우에는 강도저감계수가 0.85로 예측 되었다. 이러한 계수값은 원형과 각형인 경우 모두 같은 계수값을 보여주었다.

X-ray PTV 기법을 이용한 불투명 튜브 내부의 미세기포의 크기 및 속도 동시 측정 (Simultaneous Measurement of Size and Velocity of Microbubbles inside Opaque Tube Using X-ray PTV Technique)

  • 김석;이상준
    • 한국가시화정보학회지
    • /
    • 제4권2호
    • /
    • pp.69-75
    • /
    • 2006
  • The microbubbles were used in various fields, such as turbulent control, drag reduction, material science and life science. The X-ray PTV using X-ray micro-imaging technique was employed to mea-sure the size and velocity of micro-bubbles moving in an opaque tube simultaneously. Micro-bubbles of $10{\sim}60{\mu}m$ diameter moving upward in an opaque tube (${\phi}$=2.7mm) were tested. Due to the different refractive indices of water and air, phase contrast X-ray images clearly show the exact size and shape of over-lapped microbubbles. In all of the working fluids tested (deionized water, tap water, 0.01 and 0.10M NaCl solutions), the measured terminal velocity of the microbubbles rising through the solution was proportional to the square of the bubble diameter. The rising velocity was increased with increasing mole concentration. The microbubble can be useful as contrast agent or tracer in life science and biology. The X-ray PTV technique should be able to extract useful information on the behavior of various bio/microscale fluid flows that are not amenable to analysis using conventional methods.

  • PDF