• Title/Summary/Keyword: spiral test

Search Result 193, Processing Time 0.03 seconds

Analysis of Vertical and Horizontal Behavior of Helical Piles in Sands Varying Helix Shapes and Locations (사질토에서의 헬릭스 형상 및 위치에 따른 헬리컬 파일의 수직 및 수평 거동 분석)

  • Bae, Jonghwan;Lee, Junwon;Shin, Sehee;Kim, Dongwook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.4
    • /
    • pp.393-400
    • /
    • 2020
  • Axial and lateral behavior of helical piles is generally influenced by number, diameter, helix pitch, and locations of helices. In this study, axial and horizontal behavior of helical piles with three helices was investigated varying helices' locations, diameter, and pitch. Especially, due to the spiral shapes of helices, the effect of lateral load directions at pile heads on their lateral behavior was investigated. Axial load test of small-scale helical pile was conducted in laboratory, and its results were compared with numerical analysis results of the same model for cross check of validity of both results. Furthermore, diverse numerical analyses were performed for different shapes of helical piles. Consequently, it was found that, for the given analysis conditions, the helix diameter was the most influential factor on the horizontal and vertical behavior of helical piles.

The Effects of High Pressure Water Contact State on Hydraulic Fracturing (고압수 접촉상태가 수압파쇄에 미치는 영향)

  • Lee, Sang Hun;Lim, Jong Se;Jang, Won Yil
    • Tunnel and Underground Space
    • /
    • v.26 no.5
    • /
    • pp.409-417
    • /
    • 2016
  • The shale gas is emerging as one of the oil and gas resources which can replace the traditional oil and gas resources. As the shale layer where the shale gas is deposited has low permeability, the hydrofracturing method is required to improve the productivity. This study is designed to conduct the laboratory hydrofracturing test on the samples which are modeled after the drilling hole having the general drilling hole and spiral groove. And compare the initial fracturing pressure and fluid contact between them in order to the result of the hydrofracturing depending on the shape of the drilling hole. In addition, the results were compared with the numerical modeling values from 3DEC and they were also compared with the data from the advance researches. It was found from the study that rather than the contact area of the high pressures water, the force concentration depending on the form of guide hole was more effective in the hydrofracturing.

Morphological aspect of the attached bacteria by the sterilization method of the ultrasonic scaling tip (소독멸균 방법에 따른 초음파 스케일링 팁에 부착된 세균의 양상)

  • Nam, Seoul-Hee;Kim, Yu-rin
    • Journal of Korean society of Dental Hygiene
    • /
    • v.15 no.4
    • /
    • pp.713-718
    • /
    • 2015
  • Objectives: The purpose of the study was to investigate the bacterial morphology attached on ultrasonic scaler tips using no cleansing solution, alcohol cotton, liquid chemical disinfecting agent, and autoclave method. Methods: Scaling tip was applied to the mouth and the ultrasonic scaler tips were assigned to four groups. Group 1 was control group with no cleansing solution. Group 2 was treated with alcohol cotton. Group 3 was treated with 2% green Y-Na solution in liquid chemical disinfecting agent, and Group 4 was sterilized by autoclave method. Live bacteria were observed by phase contrast microscopy. The scanning electron microscopy(SEM) revealed the morphological characteristics of scaler surface. The type of attached bacteria were analyzed using SPSS 21.0 program. The data were analyzed by one-way analysis of variance(ANOVA) and Tukey's post-hoc test. Results: The types of sterilization methods had influences on the bacterial viability. The numbers of cocci, bacilli, spiral form bacteria, and filamentous bacteria was observed in $89.00{\pm}3.60%$, $29.67{\pm}3.51%$, $3.33{\pm}0.57%$ and $1.67{\pm}0.57%$ in control group, $31.67{\pm}3.51%$, $63.33{\pm}4.04%$, $2.00{\pm}1.00%$ and $1.67{\pm}0.57%$ in alcohol cotton group, $69.67{\pm}4.50%$, $12.33{\pm}2.51%$, 0% and 0% in liquid chemical disinfecting agent group, and 0.0%, 0.0%, 0.0% and 0.0% in autoclave method group. The clean surface of ultrasonic scaler tip was shown on SEM by autoclave method. Conclusions: The most effective sterilization method of ultrasonic scaler tip was the autoclave method. Autoclave method is the most effective sterilization method and can reduce the cross-infection in the dental clinic.

SEJONG OPEN CLUSTER SURVEY (SOS). 0. TARGET SELECTION AND DATA ANALYSIS

  • Sung, Hwankyung;Lim, Beomdu;Bessell, Michael S.;Kim, Jinyoung S.;Hur, Hyeonoh;Chun, Moo-Young;Park, Byeong-Gon
    • Journal of The Korean Astronomical Society
    • /
    • v.46 no.3
    • /
    • pp.103-123
    • /
    • 2013
  • Star clusters are superb astrophysical laboratories containing cospatial and coeval samples of stars with similar chemical composition. We initiate the Sejong Open cluster Survey (SOS) - a project dedicated to providing homogeneous photometry of a large number of open clusters in the SAAO Johnson-Cousins' UBV I system. To achieve our main goal, we pay much attention to the observation of standard stars in order to reproduce the SAAO standard system. Many of our targets are relatively small sparse clusters that escaped previous observations. As clusters are considered building blocks of the Galactic disk, their physical properties such as the initial mass function, the pattern of mass segregation, etc. give valuable information on the formation and evolution of the Galactic disk. The spatial distribution of young open clusters will be used to revise the local spiral arm structure of the Galaxy. In addition, the homogeneous data can also be used to test stellar evolutionary theory, especially concerning rare massive stars. In this paper we present the target selection criteria, the observational strategy for accurate photometry, and the adopted calibrations for data analysis such as color-color relations, zero-age main sequence relations, Sp - MV relations, Sp - $T_{eff}$ relations, Sp - color relations, and $T_{eff}$ - BC relations. Finally we provide some data analysis such as the determination of the reddening law, the membership selection criteria, and distance determination.

Numerical simulation of VOC decomposition in an arc plasma reactor (수치해석 기법을 이용한 아크 플라즈마 반응기의 VOCs 분해성능 평가연구)

  • Park, Mi-jeong;Jo, Young-min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.1-7
    • /
    • 2016
  • A range of techniques have been being developed to remove the volatile organic compounds from paining processes. High temperature decomposition of harmful VOCs using arc plasma has recently been proposed, and this work analyzed the extreme hot process by computer-aided fluid dynamics prior to the reactor design. Numerical simulations utilized the conservation equations of mass and momentum. The simulation showed that the fluid flowed down along the inner surface of the centrifugal reactor by forming intensive spiral trajectories. Although the high temperature gas generated by plasma influences the bottom of the reactor, no heat transfer in radial direction appeared. The decomposition efficiency of a typical VOCs, toluene, was found to be a maximum of 67% across the reactor, which was similar to the value (approximately 70%) for the lab-scale test.

Characteristic Analysis of Eddy Current Array Probe Signal in Combo Calibration Standard Tube Using Electromagnetic Numerical Analysis (전자기 수치해석을 이용한 표준보정시험편의 배열형 와전류 탐촉자 신호 특성 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.330-337
    • /
    • 2010
  • In this paper, 3-dimensional electromagnetic numerical analysis is performed about the eddy current(EC) array probe characteristic which is the next generation probe for accurate diagnosis of steam generator(SG) in nuclear power plants(NPPs). ASME(American Society of Mechanical Engineers) Standard and X-probe combo calibration standard tube are selected for acquisition of eddy current testing(ECT) signals and this result of compared with the real test signals for reasonability of result. Based on the analysis result of calibration standard tube, ECT signals that are about the defects of pitting, stress corrosion cracking(SCC), multiple SCC and wear is obtained. Material of specimen was Inconel 600 which is usually used for SG tubes in NPPs. The operation frequency of 300 kHz were used. The signal characteristics could be observed according to the various defects. The results in this paper can be helpful when the ECT signals from EC array probe are evaluated and analyzed.

Evolution of Interferon-Gamma Release Assay Results and Submillisievert Chest CT Findings among Close Contacts of Active Pulmonary Tuberculosis Patients

  • Yoon, Soonho;Mihn, Do-CiC;Song, Jin-Wha;Kim, Sung A;Yim, Jae-Joon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.83 no.4
    • /
    • pp.283-288
    • /
    • 2020
  • Background: Latent tuberculosis (TB) infection among TB contacts is diagnosed using plain chest radiography and interferon-gamma release assays (IGRAs). However, plain chest radiographs often miss active TB, and the results of IGRA could fluctuate over time. The purpose of this study was to elucidate changes in the results of the serial IGRAs and in the findings of the serial submillisievert chest computed tomography (CT) scans among the close contacts of active pulmonary TB patients. Methods: Patients age 20 or older with active pulmonary TB and their close contacts were invited to participate in this study. Two types of IGRA (QuantiFERON-TB Gold In-Tube assay [QFT-GIT] and the T-SPOT.TB test [T-SPOT]) and submillisievert chest CT scanning were performed at baseline and at 3 and 12 months after enrollment. Results: In total, 19 close contacts participated in this study. One was diagnosed with active pulmonary TB and was excluded from further analysis. At baseline, four of 18 contacts (22.2%) showed positive results for QFT-GIT and T-SPOT; there were no discordant results. During the follow-up, transient and permanent positive or negative conversions and discordant results between the two types of IGRAs were observed in some patients. Among the 17 contacts who underwent submillisievert chest CT scanning, calcified nodules were identified in seven (41.2%), noncalcified nodules in 14 (82.4%), and bronchiectasis in four (23.5%). Some nodules disappeared over time. Conclusion: The results of the QFT-GIT and T-SPOT assays and the CT images may change during 1 year of observation of close contacts of the active TB patients.

A Study on the Insulation Basis of Hts Transformer (초전도 변압기의 절연기반 연구)

  • Cheon, Hyeon-Gweon;Kwag, Dong-Soon;Yun, Mun-Soo;Kim, Sang-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.639-642
    • /
    • 2005
  • HTS Transformer developing is developing a power distribution and transmission class HTS transformer that is one of the 21st century superconducting frontier projects. Therefore, we prepared the model, that is Z continuous winding from Kapton insulated Cu tape for a small simulated the HTS transformer. For the development of electrical insulation design of a HTS transformer with Z continuous winding, we have been discussed insulation composition and investigated breakdown characteristics such as breakdown of liquid $N_2(LN_2)$, polymer and surface flashover on FRP and breakdown-surface combination in $LN_2$. Also we have been designed and manufactured a bobbin that has spiral slot for the Z continuous winding. The Z continuous winding mini-model from Kapton film insulated Cu tape for simulated 22.9kV class HTS transformer has been constructed using 0.1 % breakdown strength obtained by Weibull distribution. The widing model was measured their insulation characteristics such as ac (50kV, 1min) and impulse (154kV, $1.2\times50{\mu}s$ full wave, 3 times) withstand test and its excellent performance was confirmed.

  • PDF

The Measurement of Vacuum Pressure for the Multi-Stage Rotors of Disk-Type Molecular Drag Pump (원판형 분자 드래그펌프 다단 회전자에 대한 압력분포 측정)

  • Kwon, Myoung-Keun;Hwang, Young-Kyu
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.4
    • /
    • pp.272-280
    • /
    • 2009
  • In this study is performed to investigate the pumping characteristics of three-stage disk-type molecular drag pump (DTDP). The experiments are measured using five vacuum pressure gauges in the positions for rotors of DTDP. The experimented DTDP is consisted of three rotors and four stator. In the DTDP, spiral channels of three rotors are cut on the both upper surface and lower surface of a rotating disk, and corresponding stator is a planar disk. The experiments are performed in the outlet pressure range of $0.2{\sim}533\;Pa$. The pressure of each rotors are measured under the various condition of outlet pressure and throughputs, and nitrogen gas is used for test gas. In the numerical study, the pumping characteristics of each rotor are studied for the variation of throughputs in the all rotating channel. Pressure contour and velocity are obtained by the numerical simulation.

Experimental Study on the Failure Behavior of RC Octagonal Hollow Section Columns with Aspect Ratio of 4.0 and Longitudinal Steel Ratio of 2.36 ~ 4.71% (형상비 4.0이고 축방향철근비 2.36 ~ 4.71%인 팔각형 중공단면 철근콘크리트 기둥의 파괴거동에 관한 실험적 연구)

  • Ko, Seong-Hyun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.102-111
    • /
    • 2022
  • The aim of this study is to assess the seismic performance of octagonal hollow cross section reinforced concrete bridge pier, and to investigate the effect of longitudinal reinforcement ratios on the failure behavior. Four octagonal hollow section RC bridge columns of small scale model were tested under a quasi-static cyclically reversed horizontal load with constant axial load. The volumetric ratio of transverse spiral hoop of all specimens was maintained constant(0.206%), the ratios of longitudinal reinforcement were varied(2.36 ~ 4.71%). Failure behavior and seismic performance were investigated. Three specimens with the exception of lap spliced specimen showed flexure-shear failure at final stage. The test results with the exception of lap spliced specimen showed that the displacement ductility factor and accumulated energy dissipation decreased in inverse proportion to the ratio of longitudinal steel.