• Title/Summary/Keyword: spindle motor

Search Result 295, Processing Time 0.026 seconds

A Study on Vibration Detection Method of Disc by Differential Amplifying Optical Power in Optical Disc Media (광 디스크 장치에서 광량 차동증폭에 의한 디스크 진동 검출 방안에 관한 연구)

  • 김진선;곽경섭
    • Journal of Korea Multimedia Society
    • /
    • v.5 no.2
    • /
    • pp.215-221
    • /
    • 2002
  • In high speed optical disc devices, the vibration caused by unbalanced displacement leads the focus and tracking servo systems to be unstable, and increases the data search time. In this paper, we propose a new scheme to solve the unbalanced displacement problem. The proposed method detects the unbalanced rate by differential amplifying optical power received at photo diode and converts it into an electrical signal. controlling the speed of spindle motor, according to the detected unbalanced rate, makes it possible to improve the performance of tracking and data searching tasks. Also, we analyze the dynamic characteristics of focus and tracking servo systems in high speed mode and provide the firmware and hardware architecture that the proposed method can be installed as an add-on- module in the existing system.

  • PDF

The primary cilium as a multiple cellular signaling scaffold in development and disease

  • Ko, Hyuk-Wan
    • BMB Reports
    • /
    • v.45 no.8
    • /
    • pp.427-432
    • /
    • 2012
  • Primary cilia, single hair-like appendage on the surface of the most mammalian cells, were once considered to be vestigial cellular organelles for a past century because of their tiny structure and unknown function. Although they lack ancestral motility function of cilia or flagella, they share common ground with multiciliated motile cilia and flagella on internal structure such as microtubule based nine outer doublets nucleated from the base of mother centrioles called basal body. Making cilia, ciliogenesis, in cells depends on the cell cycle stage due to reuse of centrioles for cell division forming mitotic spindle pole (M phase) and assembling cilia from basal body (starting G1 phase and maintaining most of interphase). Ciliary assembly required two conflicting processes such as assembly and disassembly and balance between these two processes determines the length of cilia. Both process required highly conserved transport system to supply needed substance to grow tip of cilia and bring ciliary turnover product back to the base of cilia using motor protein, kinesin and dynein, and transport protein complex, IFT particles. Disruption of ciliary structure or function causes multiple human disorder called ciliopathies affecting disease of diverse ciliated tissues ranging from eye, kidney, respiratory tract and brain. Recent explosion of research on the primary cilia and their involvement on animal development and disease attracts scientific interest on how extensively the function of cilia related to specific cell physiology and signaling pathway. In this review, I introduce general features of primary cilia and recent progress in understanding of the ciliary length control and signaling pathways transduced through primary cilia in vertebrates.

A Study on Structural Design and Evaluation of the High Precision Cam Profile CNC Grinding Machine (고 정밀 캠 프로파일 CNC 연삭기의 구조설계 및 평가에 관한 연구)

  • Lim, Sang-Heon;Shin, Sang-Hun;Lee, Choon-Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.10
    • /
    • pp.113-120
    • /
    • 2006
  • A cam profile CNC grinding machine is developed for manufacture of high precision contoured cams. The developed machine is composed of the high precision spindle using boll bearings, the high stiffness box layer type bed and the three axis CNC controller with the high resolution AC servo motor. In this paper, structural and modal analysis for the developed machine is carried out to check the design criteria of the machine. The analysis is carried out by FEM simulation using the commercial software, CATIA V5. The machine is modeled by placing proper shell and solid finite elements. And also, this paper presents the measurement system and experimental investigation on the modal analysis of a grinding machine. The weak part of the machine is found by the experimental evaluation. The results provide structure modification data for good dynamic behaviors. And safety of the machine was confirmed by the modal analysis of modified machine design. Finally, the cam profile grinding machine was successfully developed.

Milling tool wear forecast based on the partial least-squares regression analysis

  • Xu, Chuangwen;Chen, Hualing
    • Structural Engineering and Mechanics
    • /
    • v.31 no.1
    • /
    • pp.57-74
    • /
    • 2009
  • Power signals resulting from spindle and feed motor, present a rich content of physical information, the appropriate analysis of which can lead to the clear identification of the nature of the tool wear. The partial least-squares regression (PLSR) method has been established as the tool wear analysis method for this purpose. Firstly, the results of the application of widely used techniques are given and their limitations of prior methods are delineated. Secondly, the application of PLSR is proposed. The singular value theory is used to noise reduction. According to grey relational degree analysis, sample variable is filtered as part sample variable and all sample variables as independent variables for modelling, and the tool wear is taken as dependent variable, thus PLSR model is built up through adapting to several experimental data of tool wear in different milling process. Finally, the prediction value of tool wear is compare with actual value, in order to test whether the model of the tool wear can adopt to new measuring data on the independent variable. In the new different cutting process, milling tool wear was predicted by the methods of PLSR and MLR (Multivariate Linear Regression) as well as BPNN (BP Neural Network) at the same time. Experimental results show that the methods can meet the needs of the engineering and PLSR is more suitable for monitoring tool wear.

A Study on the Tool Fracture Detection Algorithm Using System Identification (시스템인식을 이용한 공구파손검출 알고리듬에 관한 연구)

  • Sa, Seung-Yun;Yu, Eun-Lee;Ryu, Bong-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.6
    • /
    • pp.988-994
    • /
    • 1997
  • The demands for robotic and automatic system are continually increasing in manufacturing fields. There have been many studies to monitor and predict the system, but they have mainly focused upon measuring cutting force, and current of motor spindle, and upon using acoustic sensor, etc. In this study, digital image of time series sequence was acquired by taking advantage of optical technique. Mean square error was obtained from it and was available for useful observation data. The parameter was estimated using PAA(parameter adaptation algorithm) from observation data. AR(auto regressive) model was selected for system model and fifth order was decided according to parameter estimation. Uncorrelation test was also carried out to verify convergence of parameter. Through the proceedings, it was found that there was a system stability.

A Study on Structural Analysis of Integrated Machining Center (집적화된 Machining Center의 구조해석에 관한 연구)

  • Park, Seong-Jin;Lee, Choon-Man;Kim, Woong;Byun, Sam-Soo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.1
    • /
    • pp.49-54
    • /
    • 2010
  • An integrated machining center is developed for high precision and productivity manufacturing. The developed machine is composed of the high precision spindle using ball bearings, the high stiffness bed and the three axis CNC controller with the high resolution AC servo motor. In this paper, structural and modal analysis for the developed machine are carried out to check the design criteria of machine. The analysis is carried out by FEM simulation with using the commercial software, CATIA V5, ANSYS and ARMD. The simulation model of machine is made by shell and solid finite elements. This study also presents the measurement system on the modal analysis of an integrated machining center. The weak part of the machine is found by the analytical evaluation. The results provide with the structural modification data for good dynamic behaviors. And the safety of machine is confirmed by the modal analysis of modified machine design. As this study results can be trustworthy with the analysis of ANSYS and CATIA, integrated machining center can be successfully developed.

Halbach Array Type Focusing Actuator for Small and Thin Optical Data Storage Device (할바 자석배열을 이용한 초소형 정보저장장치의 초점 구동기 설계)

  • Lee, Sung-Q;Park, Kang-Ho;Paek, Mun-Cheal
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.65-69
    • /
    • 2004
  • The small form factor optical data storage devices are developing rapidly nowadays. Since it is designed for portable and compatibility with flash memory, its components such as disk, head, focusing actuator, and spindle motor should be assembled within 5 m thickness. The thickness of focusing actuator is within 2 mm and the total working range is $+/-100{\mu}m$, with the resolution of less than $1{\mu}m$. Since the thickness is limited tightly, it is hard to place the yoke that closes the magnetic circuit and hard to make strong flux density without yoke. Therefore, Halbach array is adopted to increase the magnetic flux of one side without yoke. The proposed Halbach array type focusing actuator has the advantage of thin actuation structure with sacrificing less flux density than conventional magnetic array. The optical head unit is moved on the swing arm type tracking actuator. Focusing coil is attached to swing arm, and Halbach magnet array is positioned at the bottom of deck along the tracking line, and focusing actuator exerts force by the Fleming's left hand rule. The working range and resolution of focusing actuator are analyzed with FEM and experiment.

  • PDF

Disturbance estimation of optical disc by closed loop output estimator (페루프 외란 검출기를 통한 광디스크 외란 측정)

  • Park, Jin-Young;Chun, Chan-Ho;Jun, Hong-Gul;Lee, Moon-Noh;Hyunseok Yang;Park, Young-Pil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1166-1171
    • /
    • 2001
  • The method for output disturbance estimation is proposed. In this method, output disturbance is estimated from the closed loop system dynamics using the output and control input signals. In the closed-loop output-disturbance estimator, precise system identification is required to reduce estimation error. The realization of estimator was done by the DSP board (DSPl103), and disturbance estimation in various environments was performed: change of rotation speed, media feature and spindle motor with (or without) auto-ball balancing system (ABS). From these experiments, the disturbance characteristics of ODD under various conditions are analyzed, and the desirable servo loop configuration based these results is proposed.

  • PDF

An Analysis of Damping Coefficients for Capillary Type Orifices on a Curved Stabilizer used in a High Speed Rotating Flexible Optical Disk System (고속 회전 유연 디스크 시스템에서 곡면 안정기에 가공된 모세관형 오리피스의 감쇠계수 해석)

  • Song, Ki-Wook;Rhim, Yoon-Chul
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.1
    • /
    • pp.25-30
    • /
    • 2011
  • In the last couple of years, the flexible optical disk(FOD) system that consists of a thin polycarbonate(PC) film of 95 ${\mu}m$ thick, a rigid stabilizer, and a high speed spindle motor has been spot-lighted as the next-generation optical system for archival use of digital data. The air film between the rotating disk and stabilizer provides a means for damping out the lateral disk vibrations. However, its damping-capability drops significantly as the rotational speed of the disk exceeds a specific limit and, eventually, the disk vibration propagates inward causing the whole span of the disk exhibits large vibration amplitudes. Based on the numerical simulations as well as the experimental results, the present work aims to evaluate the damping coefficient of the air-film near the outer region of the disk where the capillary type orifices are applied to the edge of the curved stabilizer.

Microscopic Approach of Mass Involving Neurovascular Pedicle in the Hand (신경혈관 줄기를 침범한 수부종양의 미세현미경적 접근)

  • Hwang, Min-Kyu;Hwang, So-Min;Lim, Kwang-Ryeol;Jung, Yong-Hui;Song, Jennifer Kim
    • Archives of Reconstructive Microsurgery
    • /
    • v.21 no.2
    • /
    • pp.86-91
    • /
    • 2012
  • Purpose: Mass can compress around tissue and cause deviation of normal anatomical structures. Often, mass grows toward neurovascular pedicle and encircles depending on the nature of mature mass. Neglecting neurovascular involvement of the mass is a serious problem not to be overlooked. Authors have performed microscopic approach regarding mass involving the neurovascular pedicle in the hand. Materials and Methods: From January 2007 through February 2012, retrospective analysis for nine cases of mass involving neurovascular pedicles was done. Patients were evaluated preoperatively by ultrasonography or MRI and checked intraoperative finding. Masses were evaluated by site, preoperative evaluation, involved neurovascular pedicle, histopathologic diagnosis, complication, and recurrence. Results: The site of mass involving neurovascular pedicles was 4 cases on the wrist, 2 cases on the palm, 2 cases on the finger, 1 case on the hand dorsum. Involved neurovascular pedicles were 3 radial arteries and nerves, 3 proper digital arteries and nerves, 1 radial artery, 1 superficial branch of radial nerve, 1 common digital artery and nerve. The histopathologic diagnosis of mass were 3 ganglions, 2 giant cell tumors, 2 epidermal cysts, 1 fibroma, and 1 benign spindle tumor. There were 2 cases of recurrence and secondary excisions were performed. Conclusion: Neurovascular pedicle injury can lead to serious complication like sensory and motor disorders, distal part ischemia, and so on. In case of mass suspected neurovascular invasion, accurate preoperative evaluation such as ultrasonography or MRI is necessary. To prevent any neurovascular related complication during mass excision, delicate surgical technique using a microscope becomes essential.

  • PDF