• 제목/요약/키워드: spin injection

검색결과 95건 처리시간 0.028초

Efficient Organic Light-emitting Diodes using Hole-injection Buffer Layer

  • Chung, Dong-Hoe;Kim, Sang-Keol;Lee, Joon-Yng;Hong, Jin-Woong;Cho, Hyun-Nam;Kim, Young-Sik;Kim, Tae-Wan
    • Journal of Information Display
    • /
    • 제4권1호
    • /
    • pp.29-33
    • /
    • 2003
  • We have investigated the effects of hole-injection buffer layer in organic light-emitting diodes using copper phthalocyanine (CuPc), poly(vinylcarbazole)(PVK), and Poly(3,4-ethylene dioxythiophene):poly(styrenesulfonate) (PEDOT: PSS) in a device structure of $ITO/bufferr/TPD/Alq_3/Al$. Polymer PVK and PEDOT:PSS buffer layer were produced using the spin casting method where as the CuPc layer was produced using thermal evaporation. Current-voltage characteristics, luminance-voltage characteristics and efficiency of device were measured at room temperature at various a thickness of the buffer layer. We observed an improvement in the external quantum efficiency by a factor of two, four, and two and half when the CuPc, PVK, and PEDOT:PSS buffer layer were used, respectively. The enhancement of the efficiency is assumed to be attributed to the improved balance of holes and elelctrons resulting from the use of hole-injection buffer layer. The CuPc and PEDOT:PSS layer function as a hole-injection supporter and the PVK layer as a hole-blocking one.

조영제 사용 전 후 확산강조영상 검사의 비교 분석에 대한 연구 (A Study on Comparative Analysis of Diffusion Weighted Image Examination before and after Contrast Injection)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.51-57
    • /
    • 2009
  • The purpose of this study would evaluate if having clinical effects on diffusion image with quantitative analysis through ADC values of brain's normal tissue and lesions before and after contrast injections using a 3.0T. From November in 2007 until December in 2008, a total of 32 patient was performed on 3.0T(Signa Excite, GE Medical System, USA) with the normal or lesions in the patient who requests diffusion weighted image with 8channel head coil. The pulse sequence was used with spin echo EPI(TR: 10000msec, TE: 72.2 msec, Matrix: 128*128, FOV: 240 mm, NEX: 1, diffusion direction: 3, b-value: 1000). Measurement results of ADC values on lesions, CSF, white matter, gray matter, lesions after contrast injection were measured less 75% than before contrast injection, infarction: 100%, CSF: 78%(high), white matter: 71.4%(low), gray matter: 50%(high, low). The results of paired t-test on the deference of ADC values which statically is significant in three(lesions, CSF, white matter)regions except for white matter(p<0.05). Quantitative analysis of lesions, CSF, white matter, gray matter have difference on all regions. ADC values were low in lesions and white matter, normal CSF after contrast injection commonly is high than before contrast injection, ADC values which white matter were high and low (50:50) after contrast injection. 3.0T diffusion weighted image clinically supposed that performing DWI examination after contrast injection was not desirable because of having effects on brain tissue.

  • PDF

Spin injection into a Semimetallic Bismuth Nanowire

  • LEE K.I.;JEUN M.H.;LEE K.Y.;PARK H.D.;LEE K.H.;JEUNG W.Y.;CHANG J.Y.;HAN S.H.;LEE W.Y.
    • 한국자기학회:학술대회 개요집
    • /
    • 한국자기학회 2004년도 동계학술연구발표회 논문개요집
    • /
    • pp.59-60
    • /
    • 2004
  • PDF

Effects of PEDOT:PSS Buffer Layer in a Device Structure of ITO/PEDOT:PSS/TPD/Alq3/Cathode

  • Ahn, Joon-Ho;Lee, Joon-Ung
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권1호
    • /
    • pp.25-28
    • /
    • 2005
  • We have investigated the effects of hole-injection buffer layer in organic light-emitting diodes using poly(3,4-ethylenedioxythiophene):poly(stylenesulfonate)(PEDOT:PSS) in a device structure of $ITO/PEDOT:PSS/TPD/Alq_{3}/cathode$. Polymer PEDOT:PSS buffer layer was made by spin casting method. Current-voltage, luminance-voltage characteristics and efficiency of device were measured at room temperature with a variation of cathode materials; Al, LiF/Al, LiAl, and Ca/Al. The device with LiF/Al cathode shows an improvement of external quantum efficiency approximately by a factor of ten compared to that of Al cathode only device. Our observation shows that cathode is important in improving the efficiency of the organic light-emitting diodes.

신규 제작법을 이용한 Copper Phthalocyanine 전자사진 감광체의 개발과 Dark Decay와 Photoinjection Efficiency에 관한 연구 (A Preparation of Copper Phthalocyanine Photoreceptor by an Aqueous Coating Method and Study of Dark Decay and Photoinjection Efficiency)

  • 이상남
    • 한국인쇄학회지
    • /
    • 제11권1호
    • /
    • pp.103-122
    • /
    • 1993
  • A cause and counterplan of the increase in dark decay rate of$\varepsilon$-CuPc/PVCz photoreceptor which is consist of the carrier generation layer (CGL) of$\varepsilon$type copper phthalocyanine ($\varepsilon$-CuPc) thin film by an aqueous coating method and the carrier transport layer (CTL) of polyvinylcarbazol (PVCz) by spin coating, are studied in this paper. Electrochemical deposition of CGL was accompanied by an increase in work function of the aluminium substrate during the processes and the enhanced work function 5.3 eV rose above the ionization potential 5.16 eV of $\varepsilon$-CuPc. This resulted in the increased injection of holes from substrate into CGL and a fast dark decay rate. Improved photoreceptor, an electron-transport $\varepsilon$-CuPc/TNF photoreceptor, led to lowing of dark decay rate and increasing of photosensitivity. The carrier generation efficiency (ηg), carrier injection efficiency (ηi) and xerographic gain (G) of the $\varepsilon$-CuPc/TNF photoreceptor were obtained by XTOF method and PIDC.

  • PDF

전도성 고분자(PEDOT)의 두께에 따른 그래핀 OLED의 전류 특성변화 연구

  • 최성호;한창훈;최병덕
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.234-234
    • /
    • 2012
  • 고효율 저전력 고휘도를 장점으로 가지고 있는 OLED의 개선을 위하여 수많은 재료와 기술이 연구되어 왔다. 전기적 손실의 방지를 위하여 다양한 재료가 연구되고 있지만 그 중에서도 가장 각광받는 것은 그래핀이다. 그래핀(graphene)은 탄소원자가 육각형 벌집 모양 배열의 격자구조를 가지는 원자 단층 두께의 물질이다. 그래핀은 에너지와 역격자의 k 벡터가 선형적으로 비례하며 전도띠(conduction band)와 가전자띠(valence band)가 한 점에서 만나는 구조를 가지는 특징으로 인해 매우 빠른 전하 이동도(Mobility)를 가지고 있다. 이와 같은 그래핀의 특성을 이용하여 전극 층으로 이용함으로써 소자 특성의 개선이 가능할 것으로 예상되었다. $1{\times}1$ inch Glass에 ITO 대신에 그래핀을 증착한 후 Spin coater를 사용하여 PEDOT을 각각 1,000 rpm, 2,000 rpm으로 도포 하였다. 그 후 HTL (Hole transport latey), ETL (Electron-transport layer), EML (Emissive layer), EIL (Electron injection layer)를 순차적으로 증착 하여 소자를 제작하였다. 발광층에는 유기물질 Alq3를 사용하여 녹색광을 방출하도록 하였다. Spin coater의 rpm에 따라 전도성 고분자의 두께가 결정이 되는데, rpm이 높을수록 두께가 얇으며, 얇을수록 소비전력 효율이 낮다. 하지만 전류밀도 특성이 균일하지 못한 것을 확인하였다. 휘도 효율 특성은 PEDOT의 두께가 얇을수록 동일한 전압에서 휘도가 낮은것을 확인 하였다. 또한 ITO를 이용한 동일 공정의 OLED와 비교하였을 때 상대적으로 낮은 휘도와 전류 효율특성을 보였지만, 전류밀도는 상대적으로 그래핀이 높은 것으로 확인되었다. 본 연구를 바탕으로 그래핀 소자의 개선이 이루어진다면 더욱 높은 효율과 휘도를 낼 수 있을 것으로 판단된다.

  • PDF

Improved Perfusion Contrast and Reliability in MR Perfusion Images Using A Novel Arterial Spin Labeling

  • Jahng, Geon-Ho;Xioaping Zhu;Gerald Matson;Weiner, Michael-W;Norbert Schuff
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.341-344
    • /
    • 2002
  • Neurodegenerative disorders, like Alzheimer's disease, are often accompanied by reduced brain perfusion (cerebral blood flow). Using the intrinsic magnetic properties of water, arterial spin labeling magnetic resonance imaging (ASLMRI) can map brain perfusion without injection of radioactive tracers or contrast agents. However, accuracy in measuring perfusion with ASL-MRI can be limited because of contributions to the signal from stationary spins and because of signal modulations due to transient magnetic field effects. The goal was to optimize ASL-MRI for perfusion measurements in the aging human brain, including brains with Alzheimer's disease. A new ASL-MRI sequence was designed and evaluated on phantom and humans. Image texture analysis was performed to test quantitatively improvements. Compared to other ASL-MRI methods, the newly designed sequence provided improved signal to noise ratio improved signal uniformity across slices, and thus, increased measurement reliability. This new ASL-MRI sequence should therefore provide improved measurements of regional changes of brain perfusion in normal aging and neurodegenerative disorders.

  • PDF

PEDOT:PSS를 이용한 OLEOs의 발광 특성 향상에 관한 연구 (A study on Improvement of OLEDs luminance property using PEDOT:PSS)

  • 김동은;김병상;김두석;권오관;이범종;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1293-1294
    • /
    • 2006
  • OLEDs based on organic thin films are similar to semiconductor base light-emitting diodes in that they were also considered to be one of the next generation flat-panel displays. They are attractive because of low-operating voltage, low power consumption, ease of fabrication, and low cost. In this study, we used poly (3,4-ethylenedioxythiophene)/poly (4-styrenesulfonate) (PE DOT : PSS) as a hole injection layer. In this experiment spin coating method was used with various speed rate. The fundamental structure of the OLEDs was ITO/PEDOT:PSS/NPB/$Alq_3$/Al. As a result, we obtained the enhancement performance of OLEDs when the spin coating speed was 4000 rpm. We obtained a maximum luminance of 24334 $cd/m^2$ at a current density of 967 $mA/cm^2$.

  • PDF