• 제목/요약/키워드: spin echo

검색결과 218건 처리시간 0.027초

The Suppressing of MR Image Artifacts using Phases Cycling in Fast SE Sequence

  • Shin, Yong-Jin;Jeong, Gwang-Woo
    • 한국자기공명학회논문지
    • /
    • 제2권1호
    • /
    • pp.59-65
    • /
    • 1998
  • The correction of image artifacts due to misadjustment in tuning of RF coils (tip angle) and in the RF single sideband spectrometer was investigated using phase cycling of the $\pi$/2 and $\pi$ pulses in spin-echo sequences. A general procedure was developed for the systematic design of phase cycles that select desirable coherence transfer pathways. To analyze a phase cycling sequence, changes in the coherence level and phase factor for each RF pulse in the spin-echo cycle must be determined. Four different phase cycling schemes (FIXED, ALTERNATE, FORWARD, REVERSED) to suppress unwanted signal components such as mirror and ghost images were evaluated using two signal acquisitions. When the receiver phase factor is cycled counter-clockwise (REVERSED), these artifacts are completely removed.

  • PDF

프로젝션 타입 고속 스핀 에코 자기공명 영상에서의 대조도 분석 (Contrast analysis in the Projection-type fast spin echo imaging in MRI)

  • 김치영;김휴정;안창범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 D
    • /
    • pp.3216-3218
    • /
    • 2000
  • Projection-type Fast Spin Echo (PFSE) imaging has robustness against motion artifacts due to patient motion during magnetic resonance imaging data acquisition, or reduce flow artifacts. However, it has difficulty in controlling T2 contrast. In this paper, T2 contrast in the PFSE method is analyzed. The contrasts in FSE and PFSE method are compared by computer simulation and experiments with volunteers.

  • PDF

The fate of necrosis-avid MR contrast material (Gadophrin-2)-enhanced area of acute reperfused myocardial infarction as determined by MR imaging with Gd-DTPA enhancement and TTC staining after four weeks in a rabbit model

  • Choe, Yeon-Hyeon;Park, Jong-Min;Weinmann, Hanns J.
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.114-114
    • /
    • 2002
  • Purpose: To know the fate of Gadophrin-2-enhanced areas in hearts with acute reperfused myocardial infarction. Method: The left anterior descending branches of coronary arteries were occluded for 90 min and reperfused for 60 min in 15 rabbits. Then, Gadophrin-2 (0.05 mmol/kg) was injected via ear veins. Short-axial T1-weighted spin echo images and fast cine images were obtained 24 hours after injection of Gadophrin-2. After four weeks, short-axial cine MRI was performed and T1-weighted spin echo Images were obtained 5 min and 15 min after injection of Gd-DTPA (0.2 mmol/kg). The animals were sacrificed and short-axial slices of the specimen were stained with 1.5% triphenyltetrazolium chloride (TTC) solution.

  • PDF

$Mn^{II}$ Location and Adsorbate Interactions in (M)MnH-SAPO-34 and (W)MnH-SAPO-34 studied by EPR and Electron Spin Echo Modulation Spectroscopies

  • Back, Gern-Ho;Kim, Yang-Hee;Cho, Young-Soo;Lee, Yong-Ill
    • 한국자기공명학회논문지
    • /
    • 제6권2호
    • /
    • pp.118-131
    • /
    • 2002
  • Manganese-doped H-SAPO-34 samples were prepared by an ion-exchanged reaction between H-SAPO-34 and paramagnetic Mn(II) species in methanol media and characterized by ESR and Electron Spin-Echo Modulation(ESEM) studies. In the hydrated (W)MnH-SAPO-34 measured in water, the Mn(II) ion was octahedrally coordinated with four framework oxygens and two water molecules at a displaced site IV of the eight membered ring window in the ellipsoidal cavity, while the Mn(II) ion was octahedrally coordinated to three framework oxygens and three water molecules at a displaced site I' of the six membered ring window in the ellipsoidal cavity in hydrated(M)MnH-SAPO-34 measured in methanol. The similar result was found in the experiments with methanol adsorbents except ethanol.

  • PDF

Diagnostic Performance of Spin-Echo Echo-Planar Imaging Magnetic Resonance Elastography in 3T System for Noninvasive Assessment of Hepatic Fibrosis

  • Se Woo Kim;Jeong Min Lee;Sungeun Park;Ijin Joo;Jeong Hee Yoon;Won Chang;Haeryoung Kim
    • Korean Journal of Radiology
    • /
    • 제23권2호
    • /
    • pp.180-188
    • /
    • 2022
  • Objective: To validate the performance of 3T spin-echo echo-planar imaging (SE-EPI) magnetic resonance elastography (MRE) for staging hepatic fibrosis in a large population, using surgical specimens as the reference standard. Materials and Methods: This retrospective study initially included 310 adults (155 undergoing hepatic resection and 155 undergoing donor hepatectomy) with histopathologic results from surgical liver specimens. They underwent 3T SE-EPI MRE ≤ 3 months prior to surgery. Demographic findings, underlying liver disease, and hepatic fibrosis pathologic stage according to METAVIR were recorded. Liver stiffness (LS) was measured by two radiologists, and inter-reader reproducibility was evaluated using the intraclass correlation coefficient (ICC). The mean LS of each fibrosis stage (F0-F4) was calculated in total and for each etiologic subgroup. Comparisons among subgroups were performed using the Kruskal-Wallis test and Conover post-hoc test. The cutoff values for fibrosis staging were estimated using receiver operating characteristic (ROC) curve analysis. Results: Inter-reader reproducibility was excellent (ICC, 0.98; 95% confidence interval, 0.97-0.99). The mean LS values were 1.91, 2.41, 3.24, and 5.41 kPa in F0-F1 (n = 171), F2 (n = 26), F3 (n = 38), and F4 (n = 72), respectively. The discriminating cutoff values for diagnosing ≥ F2, ≥ F3, and F4 were 2.18, 2.71, and 3.15 kPa, respectively, with the ROC curve areas of 0.97-0.98 (sensitivity 91.2%-95.9%, specificity 90.7%-99.0%). The mean LS was significantly higher in patients with cirrhosis (F4) of nonviral causes, such as primary biliary cirrhosis (9.56 kPa) and alcoholic liver disease (7.17 kPa) than in those with hepatitis B or C cirrhosis (4.28 and 4.92 kPa, respectively). There were no statistically significant differences in LS among the different etiologic subgroups in the F0-F3 stages. Conclusion: The 3T SE-EPI MRE demonstrated high interobserver reproducibility, and our criteria for staging hepatic fibrosis showed high diagnostic performance. LS was significantly higher in patients with non-viral cirrhosis than in those with viral cirrhosis.

Elucidation of Central Line Refocusing in Quadrupolar Echo Formation

  • Han, Duk-Young
    • 한국자기공명학회논문지
    • /
    • 제3권1호
    • /
    • pp.27-35
    • /
    • 1999
  • Quadrupolar interaction is a strong line broadening agent for nuclei of half-integer spin except the central line. The two-pulse quadrupolar echo technique is widely used, which refocuses the quadrupolar broadening. Echo formation is due to the cancellation of quadrupolar broadening effect by the applied two pulses. Since the central line is not quadrupolar broadened, it should not be involved in the echo formation. However, the central line peak always appears in experiments. This is explained qualitatively here by close examination on the time development of individual coherence. This explanation is used to predict the number of echoes that will be formed with 2 pulse sequence for nuclei of I=3/2, 5/2, 7/2, 9/2 with ease.

  • PDF