• 제목/요약/키워드: spectroscopic analysis method

검색결과 207건 처리시간 0.026초

FLUX CALIBRATION METHOD OF SLIT SPECTROMETER FOR EXTENDED SOURCES

  • Lee, Sung-Ho;Park, Soo-Jong
    • 천문학회지
    • /
    • 제39권4호
    • /
    • pp.151-155
    • /
    • 2006
  • Long slit spectrometers are widely used in optical and infrared bands in astronomy. Absolute flux calibration for extended sources, however, is not straightforward, because a portion of the radiation energy from a flux calibration star is blocked by the narrow slit width. Assuming that the point spread function(PSF) of the star is circularly symmetric, we develop a robust method to extrapolate the detected stellar flux to the unobscured flux using the measured PSF along the slit-length direction. We apply this method to our long slit data and prove that the uncertainty of the absolute flux calibration is less than a few percents.

액체 크로마토그래프법에 의한 대기시료중 미량 알데히드류의 정량 (Determination of Trace Aldehydes in Ambient Air by Liquid Chromatography)

  • 이용근;정태우
    • 한국대기환경학회지
    • /
    • 제11권4호
    • /
    • pp.339-349
    • /
    • 1995
  • The purpose on this study is to optimize the chromatographic determination method of trace aldehydes in ambient air. Carbonyl compounds in urban air were trapped at $C_{18}$ DNPH-coated cartridges, and generated hydrazone derivatives were separated by HPLC and detected by UV-vis spectroscopic detector at 360nm. Formaldehyde and acetaldehyde compounds could be isolated from urban(Seoul) air with more than 95% collection efficiency. The analytical detection limits for formaldehyde and acetaldehyde are 0.06pp $b_{v}$, 0.08pp $b_{v}$ for 108 L air samples, respectively. The precision of this method are 3 .sim. 4%(RSD) for mutiple injection of hydrazone standards. Separation of seven dinitrophenylhydrazones could be achieved in appoximately 20 minutes operation time using $C_{18}$ column with apprepriate eluent. The method was applied to the analysis of aldehydes and ketone in Seoul ambient air. The 24-h ambient levels of formaldehyde, acetaldehyde reached up to 6 .sim. 14 and 3 .sim. 8ppbv, respectively. The daily average concentration ratio were 0.60 for acetaldehyde/formaldehyde.yde.

  • PDF

산화 그래핀을 이용한 구리이온 흡착과 투과도 특성을 이용한 구리이온 농도 실시간 측정 (Cu Ions Removal Using Graphene Oxide and in-situ Spectroscopic Monitoring Method of Residual Cu Ions)

  • 김승두;류희중;오훈정;황완식
    • 반도체디스플레이기술학회지
    • /
    • 제20권2호
    • /
    • pp.87-91
    • /
    • 2021
  • Various Cu ions are discharged into water from various industries, which results in a severe trouble for groundwater, soil, air, and eventually animals and humans. In this work, graphene oxide (GO) is introduced as a Cu removal absorber and the real-time monitoring method is demonstrated. The results show that GO is a very effective material to absorb Cu ions in the solution. In addition, the residual Cu ions in the solution is monitored via optical transmittance method, which well match with Inductively Coupled Plasma Mass Spectrometer (ICP-MS) analysis.

단위용적 및 다용적 기법 자기공명분광 신호처리 분석 소프트웨어의 개발 (The Development of Signal Processing Software for Single-and Multi-Voxel MR Spectroscopy)

  • 백문영;이현용;신운재;은충기;문치웅
    • 대한전자공학회논문지SP
    • /
    • 제39권5호
    • /
    • pp.544-555
    • /
    • 2002
  • 단위용적기법(Single-Voxel Technique) 및 다용적기법(Multi-Voxel Technique)으로 얻어진 수소원자핵 자기공명분광(Proton Magnetic Resonance Spectroscopy : 1H-MRS) 데이터를 고가의 특정 workstation이 아닌 일반 PC에서 처리${\cdot}$분석 할 수 있는 GUI(Graphical User Interface) 기반의 분광분석용 소프트웨어(S/W)를 개발하고 MRS 임상 데이터로 기초적인 시험을 하였다. 단위용적기법의 MRS 경우에는 시간 영역의 측정신호와 주파수 영역의 분광정보를 한 화면에 동시에 표시할 수 있게 하였고 필요에 따라 위상보정, 필터링(filtering), 퓨리에변환 등으로 후처리 한 후 생체 대사물질(metabolite) 별 MRS 피크 면적 비를 계산하여 정성분석을 하였다. 다용적기법의 MRS에서는 측정된 신호의 재배열 및 3차원 FFT로 분광영상(spectroscopic image)을 재구성하고 이를 T1-강조 또는 T2-강조 영상 위에 중첩시켜 해부학적 정보와 함께 표시할 수 있도록 하였다. 또한 생체에서 대사물질에 해당하는 분광정보의 각 피크의 분포도(metabolite image)를 만들고 해부학적 영상과 중첩시켰다. 병원에 설치되어있는 MR 장치에서 정상인과 뇌에 이상이 있는 환자를 대상으로 얻은 MR 분광 데이터를 처리·분석한 결과 사용자의 편의성이 높을 뿐만 아니라 신뢰성이 우수하여 임상적 활용도가 높을 것으로 기대된다.

Diverse Chemo-Dynamical Properties of Nitrogen-Rich Stars Identified from Low-Resolution Spectra

  • Changmin Kim;Young Sun Lee;Timothy C. Beers;Young Kwang Kim
    • 천문학회지
    • /
    • 제56권1호
    • /
    • pp.59-73
    • /
    • 2023
  • The second generation of stars in the globular clusters (GCs) of the Milky Way (MW) exhibit unusually high N, Na, or Al, compared to typical Galactic halo stars at similar metallicities. The halo field stars enhanced with such elements are believed to have originated in disrupted GCs or escaped from existing GCs. We identify such stars in the metallicity range -3.0 < [Fe/H] < 0.0 from a sample of ~36,800 giant stars observed in the Sloan Digital Sky Survey and Large Sky Area Multi-Object Fiber Spectroscopic Telescope survey, and present their dynamical properties. The N-rich population (NRP) and N-normal population (NNP) among our giant sample do not exhibit similarities in either in their metallicity distribution function (MDF) or dynamical properties. We find that, even though the MDF of the NRP looks similar to that of the MW's GCs in the range of [Fe/H] < -1.0, our analysis of the dynamical properties does not indicate similarities between them in the same metallicity range, implying that the escaped members from existing GCs may account for a small fraction of our N-rich stars, or the orbits of the present GCs have been altered by the dynamical friction of the MW. We also find a significant increase in the fraction of N-rich stars in the halo field in the very metal-poor (VMP; [Fe/H] < -2.0) regime, comprising up to ~20% of the fraction of the N-rich stars below [Fe/H] = -2.5, hinting that partially or fully destroyed VMP GCs may have in some degree contributed to the Galactic halo. A more detailed dynamical analysis of the NRP reveals that our sample of N-rich stars do not share a single common origin. Although a substantial fraction of the N-rich stars seem to originate from the GCs formed in situ, more than 60% of them are not associated with those of typical Galactic populations, but probably have extragalactic origins associated with Gaia Sausage/Enceladus, Sequoia, and Sagittarius dwarf galaxies, as well as with presently unrecognized progenitors.

과당에서 전환된 5-HMF(5-hydroxymethylfurfural)의 정량적 분석 (Quantitative analysis of 5-HMF produced from fructose)

  • 심재훈;신수정
    • 펄프종이기술
    • /
    • 제45권1호
    • /
    • pp.27-34
    • /
    • 2013
  • Quantitative analysis of 5-hydroxymethylfufural (5-HMF) conversion from fructose by dehydration and rearrangement was investigated by $^1H$-NMR spectroscopic method. Fructose was converted to 5-HMF in dimethylsulfoxide (DMSO)-$d^6$ or acidic deuterium hydroxide at controlled reaction temperature and time. With addition of internal standards (biphenyl for DMSO-$d^6$ solvent, and 2,5-dihydroxybenzoic acid for deuterium oxide solvent), conversion from fructose to 5-HMF was analyzed by $^1H$-NMR spectroscopy. Quantitative analysis was run by comparison with peak area integration between of 5-HMF and internal standard. In DMSO solvent, 5-HMF was stable end product but part of 5-HMF was converted to formic and levulinic acid at acidic aqueous medium.

Novel Synthesis and Characterization of Pt-graphene/TiO2 Composite Designed for High Photonic Effect and Photocatalytic Activity under Visible Light

  • Ye, Shu;Oh, Won-Chun
    • 한국세라믹학회지
    • /
    • 제54권1호
    • /
    • pp.28-32
    • /
    • 2017
  • The degradation of methyl blue (MB) catalyzed by platinum (Pt)-graphene/$TiO_2$ in dark ambiance was studied. Pt-graphene/$TiO_2$ composites were prepared by simple hydrothermal method. Characterizations of composites were studied by X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM), specific surface area (BET) analysis, and energy dispersive X-ray (EDX) analysis. UV-spectroscopic analysis of the dyes was performed by measuring the change in absorbance. The degradation of the organic dyes was calculated based on the decrease in concentration of the dyes with respect to regular time intervals. Rate coefficients for the catalytic process were successfully established and reusability tests were performed to test the stability of the used catalysts.

해동피로부터 Kalopanax-saponin B의 분리 및 함량분석 (Isolation and Quantitative Analysis of Kalopanax-Saponin B from Kalopanacis Cortex)

  • 홍성수;황지상;허재두;이경순;노재섭
    • 생약학회지
    • /
    • 제33권4호통권131호
    • /
    • pp.277-284
    • /
    • 2002
  • For the quality control of Kalopanacis Cortex, saponin compound, kalopanax-saponin B was isolated from the MeOH extract of Kalopanacis Cortex, and identified by the spectroscopic evidences. A quantitative analysis of kalopanaxsapo-nits B using HPLC method showed that the average contents was $1.010{\pm}0.212%$, respectively, in 22 samples collected through-out the regions of Korea.

High-resolution 1H NMR Spectroscopy of Green and Black Teas

  • Jeong, Ji-Ho;Jang, Hyun-Jun;Kim, Yongae
    • 대한화학회지
    • /
    • 제63권2호
    • /
    • pp.78-84
    • /
    • 2019
  • High-resolution $^1H$ NMR spectroscopic technique has been widely used as one of the most powerful analytical tools in food chemistry as well as to define molecular structure. The $^1H$ NMR spectra-based metabolomics has focused on classification and chemometric analysis of complex mixtures. The principal component analysis (PCA), an unsupervised clustering method and used to reduce the dimensionality of multivariate data, facilitates direct peak quantitation and pattern recognition. Using a combination of these techniques, the various green teas and black teas brewed were investigated via metabolite profiling. These teas were characterized based on the leaf size and country of cultivation, respectively.

소포제중 실리콘 오일의 함량에 대한 분석 (Quantitative Analysis of Silicone Oil in Antifoaming Agent)

  • 김경숙;양석란;임춘식;박현주
    • 대한화학회지
    • /
    • 제44권4호
    • /
    • pp.337-342
    • /
    • 2000
  • 현재 한전의 화력발전소에서 사용되는 실리콘 오일계 소포제의 품질관리를위해 각종 실험을 실시한 결과 제조업체별로 다른 계면활성제 (예를 들면 유화제와증점제)를 사용하고 있어 가가의 소포제는 특징적인 물성을 나타냄을 확인할 수 있었다. 보다 간편하면서도 정확한 소포제의 품질관리를 위해 고안된본 실험은 소포제에 사용된 계면활성제의 종류나 양에 관계없이 소포제에 함유된 실리콘 오일의 정확한 함량을 측정하고자 시도하였다. 우선 매우 간단한 실험 기구로 행할수 있은 중량법이나 원심분리법을 사용하여 실리콘 오일의 함량을 구한 다음, FT-IR에 의한 분광법을 사용하여 비교${\cdot}$확인하였다. 원심분리법은 바탕실험과 실제 소포제에 대해 적용한 결과, 소포제 내의 실리콘 오일의 전량 회수되지 않으므로 오일 함량의 분석에는 좋은 방법이 될 수 없음을 확인하였다. 한편 일부 회사에서 제조된 소포제의 경우 이들 방법 사리에 상당한 차이를 나타내었다. 비교실험 결과, FT-IR에 의한 분광법이 적은 시료의 양으로 짧은 시간내에 손쉽게 분석이 가능하고 좋은 재현상을 나타내므로, 언급한 전처리 방법과 함께 사용할 경우 첨가된 계면활성제의 종류와 양에 관계없이 좋은 결과를 얻을 수 있다고 판단된다.

  • PDF