• Title/Summary/Keyword: spectral measurements

Search Result 424, Processing Time 0.029 seconds

Radiometric Calibration Method of the GOCI (Geostationary Ocean Color Imager)

  • Kang, Gumsil;Myung, Hwan-Chun;Youn, Heong-Sik
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.60-63
    • /
    • 2006
  • Geostationary Ocean Color Imager (GOCI) is under development to provide a monitoring of oceancolor around the Korean Peninsula from geostationary platforms. It is planned to be loaded on Communication, Ocean, and Meteorological Satellite (COMS) of Korea. In this paper radiometric calibration concept of the GOCI is introduced. The GOCI radiometric response is modeled as a nonlinear system in order to reflect a nonlinear characteristic of detector. In this paper estimation approaches for radiometric parameters of GOCI model are discussed. For the GOCI, the offset signal depends on each spectral channel because dark current offset signal is a function of integration time which is different from channel to channel. The offset parameter can be estimated by using offset signal measurements for two integration time setting is described.

  • PDF

Analysis of Electroencephalogram and Electrocardiogram at an Acupoint PC9 during Pulsed Magnetic Field Stimulus

  • Lee, Jin-Yong;Hwang, Do-Gwen;Yoo, Jun-Sang;Lee, Hyun-Sook
    • Journal of Magnetics
    • /
    • v.17 no.2
    • /
    • pp.133-137
    • /
    • 2012
  • We investigated the effects of pulsed magnetic fields (PMF) stimulus on electroencephalogram (EEG) alpha activity and heart rate variability (HRV) from electrocardiogram (ECG) measurements with various stimulus durations at acupoint PC9. The alpha activity in the EEG and the ratio of low frequency power and high frequency power (LHR) in the HRV, a reflection of sympathovagal activity, were increased and decreased, respectively, after PMF stimulus of 3 min. Our spectral analysis quantitatively proved that the changes in the EEG alpha activity were consistent with an autonomic function in the ECG. These findings suggest that appropriate PMF stimulus results in the same effect as that of acupuncture applied to the acupoint PC9, which is closely related to the parasympathetic activity of the autonomic nervous system.

SPECTROSCOPIC STUDIES IN X-RAY ASTRONOMY (X-선 천문 분야의 분광관측 연구)

  • CHOI CHUL-SUNG
    • Publications of The Korean Astronomical Society
    • /
    • v.15 no.spc1
    • /
    • pp.73-83
    • /
    • 2000
  • X-ray astronomy deals with measurements of the electromagnetic radiation in the energy range of $E\~0.1-100 keV (\lambda\~0.12-120{\AA})$. The wavelength of X-ray is comparable to the size of atoms, so that the photons in the X-ray range are usually produced and absorbed by the atomic processes. Since the launch of the first X-ray astronomy satellite 'Uhuru' in 1970, technological advances in a launch capability and a detection capability make X-ray astronomy one of the most rapidly evolving fields of astronomical research. Particularly, a spectral resolving power $E/{\Delta}E$ has been increased by an order of 2 - 3 (in the energy range of 0.1 - 10 keV) during the past 30years. In this paper, I briefly review a developing process of the resolving power and spectroscopic techniques. Then I describe important emission/absorption lines in X-ray astronomy, as well as diagnostics of gas property with line parameters.

  • PDF

Void Contents Evaluation of Composite Laminates by Ultrasonic Attenuation Measurements (초음파의 감쇠를 이용한 복합재료의 기공함량 평가)

  • 정현조
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.6
    • /
    • pp.1535-1541
    • /
    • 1994
  • The void content of carbon fiber reinforced composite laminates was determined by the ultrasonic nondestructive technique. The ultrasonic immersion, through-transmission method developed stresses the utilization of spectral analysis and frequency dependence of the attenuation due to porosity. The measured attenuation shows approximately linear behavior over the frequency range investigated. The linear relationship between the void content and the attenuation slop (d $\alpha$/df) is found to hold, but the constant of proportionality is quite different for samples with different pore morphology. The void volume fraction determined by the attenuation slope agreed very well with that obtained by the acid digestion analysis.

A Study on a Technique of the Measurement of Flame Temperature and Soot Using the Two-color Method in Diesel Engines (디젤엔진에서 이색법을 이용한 화염온도와 Soot의 계측기술에 관한 연구)

  • Lee, Tae-Won;Lee, Seon-Bong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.9
    • /
    • pp.3007-3014
    • /
    • 1996
  • The instantaneous flame temperature and soot formation and oxidation in a D.I. diesel engine are measured using a two-color method. The proposed method based on the continuous spectral radiation from the soot particles in the flame is applicable to industrial diesel engines without major modifications of their main characteristics. Measurements are performed at one location inside the combustion chamber of a D.I. diesel engine. Effects of different engine speeds and loads on flame temperature and KL factor which is an index of soot concentration were examined. Little temperature change were observed with increasing rpm, while increased with loads. The higher the flame temperature is, the lower the KL factor is.

A Study on Temperature Features of Broadband Ultrasonic Attenuation (초음파 광역 감쇠의 온도 특성에 관한 연구)

  • 신정식;안중환;한승무;김형준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.245-248
    • /
    • 1997
  • The distilled water is used for the ultrasonic wave propagating material in the measurements of broadband ultrasonic attenuation (BUA) that is applied in industrial and medical applications, The acoustic impedance of water is significantly changed with its temperature. Therefore, the quantitative evaluation of BUA with temperature and the ultrasonic wave propagating distance is highly needed. In this study, we evaluated the variation of attenuation with change in temperature. To measure the variation of BUA in the low frequency region at the temperatures, 27$^{\circ}C$, 29$^{\circ}C$, and 31$^{\circ}C$, we tested the Plyethylene, Teflon, MC-Nylon, Urethane specimens and analyzed the center frequency, frequency bandwidth, spectral peak amplitude. The results showed that BUA value appeared to be lower with increasing temperature. This may be due to the fact that the frequency feature of ultrasonic wave is affected by not only the specific gravity, acoustic impedence, but material crystalline, porosity, the distance of ultrasonic wave propagation in water.

  • PDF

Development of Micro-Cooling Fans for Cooling of CPU (CPU 냉각용 저소음 Micro-Cooling Fan 의 개발)

  • 김기황;박용민;김진화;이승배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.961-966
    • /
    • 2001
  • Micro fans of randomly swept-blades were designed to provide C.P.U. in a personal computer with effective cooling in a very quiet mode. The proto--type axial micro-fans machined by a laser sintering machine were tested against manufactured products by comparing the performance and overall sound pressure level with spectral measurements in an environment suggested by ASHRAE and ANSI standards. The predicted OSPLs and directivity patterns of fans by iDesignFan software were in good agreements with measured data. The newly introduced fans of randomly swept-blades were proved to provide a very promising mode of low noise at small loading conditions.

  • PDF

Elimination of Self Noise & Doppler Effects from the Microphone Array Measurement (마이크로폰 어레이 측정에서의 도플러 효과와 자체소음 제거에 관한 실험적 연구)

  • Rhee, Wook;Park, Sung;Kim, Jai-Moo;Choi, Jong-Soo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.7 s.112
    • /
    • pp.677-682
    • /
    • 2006
  • In the case of aeroacoustic test in windtunnel, measurement accuracy is reduced by not only Doppler effects but also by the microphone self noise due to airflow and high turbulence in the wall boundary layer. Microphone array measurements can be easily utilized for the solutions of these problems. In this paper, geometrical optics approach and diagonal term elimination of cross spectral matrix was introduced to the de-dopplerization and self noise reduction methods for the microphone array measurement. For the validation, beamforming tests for sinusoidal point source were performed in the closed type test section of windtunnel, and their performances of beam width and sidelobe rejection were significantly improved.

Leak detection in a pipeline based on estimation theory

  • Jeong, Sang-Hun;Bang, Sung-Ho;Lee, Kwang-Soon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.170-175
    • /
    • 1992
  • A leak detection method for diagnosis of the leak position in a pipeline was developed using an estimation theory with the assumption that the measured flow rates and pressures are stochastic processes. A notch filter was designed using power spectral density analysis of measurements to reduce the effects of disturbances. The noise model dimension was determined by hypothesis testing and then recursive extended least square method was applied to estimate the leak position in real time. The proposed method was applied to an experimental system for evaluation of its performance.

  • PDF

Spectral and Thermal Properties of Some Uranyl Complexes of Some Schiff-Bases Derived from Glycylglycine

  • Sh. A. Sallam;M. I. Ayad
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.3
    • /
    • pp.199-205
    • /
    • 2003
  • Complexes of uranyl ion $UO^{+2}_2$with Schiff-bases obtained by condensing glycylglycine with salicylaldehyde; 2-hydroxy-1-naphthaldehyde, 2,3-dihydroxybenzaldehyde, and 2,4-dihydroxybenzaldehyde have been synthesized and characterized through elemental analysis, conductivity measurements, magnetic susceptibility determinations, u.v., i.r. and $^1H$ nmr spectra as well as d.t.a., t.g. and d.s.c. techniques. Structures and mechanisms of thermal decomposition are proposed.