• Title/Summary/Keyword: spectral measurements

Search Result 424, Processing Time 0.024 seconds

THE APPLICATION OF THE TOMS AEROSOLS RETRIEVAL ALGORITHM TO GLI MEASUREMENTS

  • Lee Hyun Jin;Kim Jae Hwan;Fukushima Hajime;Ha Kyung-Ja
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.381-384
    • /
    • 2005
  • We have applied the TOMS aerosols retrieval algorithm to GLI measurements. TOMS has utilized the aerosol index, which is a measure of the change in spectral contrast due to the wavelength-dependent effects of aerosols. We have retrieved the GLI aerosol index, which is made by the pair of 380/400nm, 380/412nm, 380/460nm, and 412/460nm. We have found that the biomass burning aerosols represent the absorbing aerosols. In addition, the pair of 380/460nm has shown the best signal for detecting aerosols in Principal Component Analysis(PCA) and comparison of aerosol optical thickness from AERONET data. The theoretical aerosol index is also shown the best signal in the pair of 380/460nm.

  • PDF

NEAR INFRARED BIO-SPECTROSCOPY : APPROACHES FOR MEASUREMENTS IN CRITICAL CARE

  • Burns, David
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.2102-2102
    • /
    • 2001
  • Near infrared, diffuse reflectance spectroscopy has shown significant potential for in vitro and in vivo assessment of metabolic status. However, the complexity of living samples can lead to ambiguous results. This presentation will focus on methods that provide controls for scattering and absorption estimation in tissue. For robust estimations, normalization procedures will be shown which can greatly improve interpretability of results. Normalization based on time, location and spectral property will be shown with data from models, tissue phantoms and in vivo measurements. In particular, interpretation of NIR spectra associated with major respiratory constituents will be examined. Measurement of constituents such as hemoglobin, myoglobin, tissue edema, and lactate will be shown. Results suggest that NIR may provide a valuable tool for physiological monitoring in critical care research and practice.

  • PDF

Thermal denaturation analysis of protein

  • Miyazawa, Mitsuhiro
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1628-1628
    • /
    • 2001
  • Near infrared (NIR) spectroscopy is a powerful technique for non-destructive analysis that can be obtained in a wide range of environments. Recently, NIR measurements have been utilized as probe for quantitative analysis in agricultural, industrial, and medical sciences. In addition, it is also possible to make practical application on NIR for molecular structural analysis. In this work, Fourier transform near infrared (FT-NIR) measurements were carried out to utilize extensively in the relative amounts of different secondary structures were employed, such as Iysozyme, concanavalin A, silk fibroin and so on. Several broad NIR bands due to the protein absorption were observed between 4000 and $5000\;^{-1}$. In order to obtain more structural information from these featureless bands, second derivative and Fourier-self-deconvolution procedures were performed. Significant band separation was observed near the feature at $4610\;^{-1}$ ,. Particularly the peak intensity at $4525\;^{-1}$ shows a characteristic change with thermal denaturation of fibroin. The structural information can be also obtained by mid-IR and CD spectral. Correlation of NIR spectra with protein structure is discussed.

  • PDF

Circular cylinder drag reduction using piezoelectric actuators

  • Orazi, Matteo;Lasagna, Davide;Iuso, Gaetano
    • Advances in aircraft and spacecraft science
    • /
    • v.1 no.1
    • /
    • pp.27-41
    • /
    • 2014
  • An active flow control technique based on "smart-tabs" is proposed to delay flow separation on a circular cylinder. The actuators are retractable and orientable multilayer piezoelectric tabs which protrude perpendicularly from the model surface. They are mounted along the spanwise direction with constant spacing. The effectiveness of the control was tested in pre-critical and in post-critical regime by evaluating the effects of several control parameters of the tabs like frequency, amplitude, height, angular position and plate incidence with respect to the local flow. Measurements of the mean static pressure distribution around the cylinder were used to estimate the pressure drag coefficient. The maximum drag reduction achieved in the pre-critical regime was of the order of 30%, whereas in the post-critical regime was about 10%, 3% of which due to active forcing. Furthermore, pressure fluctuation measurements were performed and spectral analysis indicated an almost complete suppression of the vortex shedding in active forcing conditions.

Discrete HMM Training Algorithm for Incomplete Time Series Data (불완전 시계열 데이터를 위한 이산 HMM 학습 알고리듬)

  • Sin, Bong-Kee
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.1
    • /
    • pp.22-29
    • /
    • 2016
  • Hidden Markov Model is one of the most successful and popular tools for modeling real world sequential data. Real world signals come in a variety of shapes and variabilities, among which temporal and spectral ones are the prime targets that the HMM aims at. A new problem that is gaining increasing attention is characterizing missing observations in incomplete data sequences. They are incomplete in that there are holes or omitted measurements. The standard HMM algorithms have been developed for complete data with a measurements at each regular point in time. This paper presents a modified algorithm for a discrete HMM that allows substantial amount of omissions in the input sequence. Basically it is a variant of Baum-Welch which explicitly considers the case of isolated or a number of omissions in succession. The algorithm has been tested on online handwriting samples expressed in direction codes. An extensive set of experiments show that the HMM so modeled are highly flexible showing a consistent and robust performance regardless of the amount of omissions.

Development of Medical Ultrasound Imaging Techniques for Tissue Characterization (The Correction Method of Diffraction Effect in Measurements of Attenuation Coefficient) (조직 정량화를 위한 의용 초음파 영상 기술 개발(감쇠계수 측정에서 회질 영향의 보정법))

  • 한성현;이강호;최종호;최종수
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.12
    • /
    • pp.1925-1932
    • /
    • 1990
  • In this paper, we consider the effect of diffraction due to the finite-sized aperture and propose the new correction method of errors in measurements of attenuation coefficient owing to the diffraction effect. In the existing correction method, we obtained the attenuation coefficient after correct the spectrum at each depth. However, this paper obtain the attenuation coefficient using lg-spectral difference approach and then correct errors. As a proposed method is not correction for the spectrum at each depth but the difference spectrum, we reduce the calculation. Also the correction is performed through the total frequency range, the accurate attenuation coefficient in whole bandwidth is produced.

  • PDF

Measurement and prediction of geometric imperfections in structural stainless steel members

  • Cruise, R.B.;Gardner, L.
    • Structural Engineering and Mechanics
    • /
    • v.24 no.1
    • /
    • pp.63-89
    • /
    • 2006
  • Geometric imperfections have an important influence on the buckling response of structural components. This paper describes an experimental technique for determining imperfections in long (5.7 m) structural members using a series of overlapping measurements. Measurements were performed on 31 austenitic stainless steel sections formed from three different production routes: hot-rolling, cold-rolling and press-braking. Spectral analysis was carried out on the imperfections to obtain information on the periodic nature of the profiles. Two series were used to model the profile firstly the orthogonal cosine and sine functions in a classic Fourier transform and secondly a half sine series. Results were compared to the relevant tolerance standards. Simple predictive tools for both local and global imperfections have been developed to enable representative geometric imperfections to be incorporated into numerical models and design methods.

Estimation of Surface Temperature of the Urban Area in Cheongju Using ASTER Data (ASTER에 의한 청주시주변의 지표면온도 추정)

  • Park, Jong-Hwa;Na, Sang-Il
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.563-568
    • /
    • 2005
  • Land surface temperature (LST) for large areas can only be derived from surface-leaving radiation measured by satellite sensors. These measurements represent the integrated effect of the surface and are superior to point measurements on the ground, e.g. in Urban Heat Island. ASTER (Advanced Spaceborne Thermal Emission and Reflection Radiometer) is an imaging instrument that is flying on the NASA's Terra satellite launched in December 1999. ASTER acquires 14 spectral bands and can be used to obtain detailed datas of land surface temperature, emissivity, reflectance and elevation. Spatial resolution of 90m of TIR channels of ASTER is useful when we analyze the spatial variations of surface heat fluxes in urban areas. The purpose of this study is to extract the LST using ASTER TIR channels.

  • PDF

Investigating the relation between AGN gas metallicity and their host galaxy stellar metallicity using a sample of local Seyfert 1 galaxies

  • Shin, Jae-Jin;Woo, Jong-Hak
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.72.1-72.1
    • /
    • 2011
  • We investigate the relation between AGN gas metallicity and their host galaxy stellar metallicity using a sample of local Seyfert 1 galaxies. Stellar metallicity is measured from stellar absorption lines while AGN gas metallicity is derived from the flux ratios of UV emission lines. We use a high quality spectra obtained from the Lick AGN Monitoring Project, to obtain pure host galaxy spectra based on the spectral decomposition analysis, leading to accurate measurements of the Mg2 (5175) and Fe (5270) indices. In the case of AGN gas metallicity, we measure the ratio of NV1240 to CIV1549 lines using UV spectra from the archival IUE and HST STIS data. We will present the results of metallicity measurements and comparison between AGN and stellar metallicity, and discuss the implications of the results.

  • PDF

An investigation of the Photospheric and Chromospheric Layers of Sunspots

  • Kim, Hyun-Nam;Solanki, Sami. K.;Lagg, Andreas;Kim, Kap-Sung;Choe, G.S.;Kwon, Yong-Jun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.95.2-95.2
    • /
    • 2011
  • The most powerful technique for deducing the magnetic structure of the Sun is spectro-polarimetry. Detailed measurements of the polarization signal of the spectral lines (Stokes vector) allow us to infer the physical conditions in the solar atmosphere prevailing during the line formation. Inversion codes are the main tool to extract this information from the Stokes spectra. This study will focus on measurements of the chromospheric He I 1083.0 nm triplet and the photospheric Si I 1082.7 nm line. A spectropolarimetric data set of sunspots, obtained with the German Vacuum Tower Telescope (VTT) at the Teide observatory on Tenerife, is analyzed using an inversion technique. We will introduce the German Vacuum Tower Telescope and the inversion code HeLix, and will show data sets that are analyzed by HeLix.

  • PDF