• 제목/요약/키워드: speckle image

검색결과 197건 처리시간 0.021초

Assessment of speckle image through particle size and image sharpness

  • Qian, Boxing;Liang, Jin;Gong, Chunyuan
    • Smart Structures and Systems
    • /
    • 제24권5호
    • /
    • pp.659-668
    • /
    • 2019
  • In digital image correlation, speckle image is closely related to the measurement accuracy. A practical global evaluation criterion for speckle image is presented. Firstly, based on the essential factors of the texture image, both the average particle size and image sharpness are used for the assessment of speckle image. The former is calculated by a simplified auto-covariance function and Gaussian fitting, and the latter by focusing function. Secondly, the computation of the average particle size and image sharpness is verified by numerical simulation. The influence of these two evaluation parameters on mean deviation and standard deviation is discussed. Then, a physical model from speckle projection to image acquisition is established. The two evaluation parameters can be mapped to the physical devices, which demonstrate that the proposed evaluation method is reasonable. Finally, the engineering application of the evaluation method is pointed out.

레이저 스펙클 내시경을 이용한 미세혈관 영상화 기법 (Laser Speckle Imaging Using Laser Speckle Endoscope)

  • 진호영;신현출
    • 대한전자공학회논문지SP
    • /
    • 제47권6호
    • /
    • pp.91-96
    • /
    • 2010
  • 간섭성을 가진 레이저 빛을 산란체에 주사하였을 때 반사되는 정보의 간섭현상에 의해 생기는 불규칙한 무늬를 레이저 스펙클이라 한다. 레이저 스펙클 시스템은 동물의 특정부분의 기능적인 측면 관찰이 가능하고, 상대적으로 저렴하고 간단한 시스템으로 구성된다. 레이저 스펙클 시스템의 가장 큰 특징은 스펙클 이미지를 영상처리 과정을 통해 미세혈관 관찰이 가능하다는 것이다. 기존의 연구는 주로 영상처리를 통한 화질개선에 대해 연구가 많이 진행되었지만 본 논문에서는 레이저 스펙클 시스템을 소형화 하여 상용화시키기 위한 단계로서 레이저 스펙클 내시경을 제작하였다. 제작된 내시경의 성능테스트를 위해 동물실험으로 성능을 입증할 것이다. 피실험체로서 꼬리부분에 미세혈관을 가진 금붕어를 사용하였고 일반 자연광 이미지와 영상처리된 스펙클 이미지를 비교함으로써 내시경 시스템의 가능성을 보일 것이다.

TVG 필터를 이용한 소나 영상의 스펙클 노이즈 제거 (Speckle Denoising of Sonar Image using TVG Filter)

  • 류재훈;류광렬
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2016년도 추계학술대회
    • /
    • pp.965-968
    • /
    • 2016
  • 본 논문은 PDF 웨이블릿 변환과 TVG 필터를 이용한 Sonar Image 의 스펙클 노이즈 제거에 관한 연구이다. TVG 필터는 해저면 바닥의 불규칙한 물체를 식별하는데 방해되는 Speckle Noise를 시간적이고 귀납적인 관찰의 결과로 얻어진 Gain 값으로 제거 한다. 실험 결과, 제안된 필터는 Speckle Noise를 약 90% 제거하여 보다 향상된 해저 영상 식별이 가능하다.

  • PDF

OCT 영상 개선을 위한 웨이블릿 영역에서의 Speckle 저감 방법 (Speckle Reduction Method in Wavelet Domain for OCT Image Enhancement)

  • 이창수;나지훈;이병하;장주완
    • 제어로봇시스템학회논문지
    • /
    • 제12권4호
    • /
    • pp.364-370
    • /
    • 2006
  • Optical coherence tomography (OCT) is high resolution medical imaging system which is obtaining image inside biological objects with non-destructive method. OCT system is based on Michelson interferometer with a reciprocating mirror in the reference arm and a biological object in the sample arm. The obtained OCT image suffers from a granular or mottled image, called speckle. Speckle is caused by random interferences between reflected coherence waves. In this paper, we propose effective speckle reduction method that uses wavelet transform. With wavelet domain image, sub-windowing and thresholding are performed. Finally, speckle reduction experiments for Misgurnus mizolepis skin and rat eye images are shown.

Speckle Reduction in the Wavelet Domain for Image with Optical Coherence Tomography

  • Chang, Ju-Wan;Lee, Chang-Su;Na, Ji-Hoon;Paes, Stephane;Lee, Byeong-Ha
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2459-2463
    • /
    • 2005
  • Optical coherence tomography (OCT) is high resolution medical imaging system which is obtaining image inside biological objects with non-destructive method. OCT system is based on Michelson interferometer with a reciprocating mirror in the reference arm and a biological object in the sample arm. The obtained OCT image suffers from a granular or mottled image, called speckle. Speckle is caused by random interferences between reflected coherence waves. In this paper, we propose effective speckle reduction method that uses wavelet transform. With wavelet domain image, sub-windowing and thresholding are performed. Finally, speckle reduction experiments for Misgurnus mizolepis skin and rat eye images are shown.

  • PDF

적응 윈도우 기법을 사용한 레이저 스펙클 영상의 처리 (Laser Speckle Imaging Using Adaptive Windowing Method)

  • 진호영;신현출
    • 대한전자공학회논문지SP
    • /
    • 제47권1호
    • /
    • pp.97-102
    • /
    • 2010
  • 레이저 스펙클이란 간섭성을 가진 레이저 빛을 산란체에 쏘았을 때 반사되는 정보를 레이저 스펙클이라 한다. 이 레이저 스펙클의 가장 큰 특징은 현재 의학 기술로는 볼 수 없는 미세혈관 관찰이 가능하다는 것이다. 미세혈관 관찰을 위해서 레이저 스펙클 장치로 얻은 이미지를 영상처리 하는 과정이 필요하다. 이 논문은 공간적 방향으로 다양한 크기의 윈도우를 적용시키는 새로운 영상처리법을 제안하였다. 기존의 영상처리법 LASCA에서는 고정된 크기의 윈도우를 적용시켜 영상처리 하였다. 하지만 작은 크기의 윈도우를 적용하였을 경우 이미지의 공간 해상도가 좋아 혈관이 잘 보이는 장점이 있지만 스펙클 노이즈의 영향을 많이 받게되는 반면 큰 크기의 윈도우를 적용하였을 경우 노이즈 제거에는 큰 효과를 보지만 해상도가 낮아져 영상이 흐릿해지는 현상을 발견할 수 있다. 그래서 우리는 이 두가지 방법의 장점만 살리는 적응 윈도우 기법을 소개한다. 우리는 적응 윈도우 기법과 기존의 라스카 이미지를 비교하여 보일 것이며 적응 윈도우 기법을 이용해 영상의 화질을 높인 것을 보일 것이다.

젖소의 개체인식 및 형상 정보화를 위한 컴퓨터 시각 시스템 개발 (I) - 반문에 의한 개체인식 - (Development of Computer Vision System for Individual Recognition and Feature Information of Cow (I) - Individual recognition using the speckle pattern of cow -)

  • 이종환
    • Journal of Biosystems Engineering
    • /
    • 제27권2호
    • /
    • pp.151-160
    • /
    • 2002
  • Cow image processing technique would be useful not only for recognizing an individual but also for establishing the image database and analyzing the shape of cows. A cow (Holstein) has usually the unique speckle pattern. In this study, the individual recognition of cow was carried out using the speckle pattern and the content-based image retrieval technique. Sixty cow images of 16 heads were captured under outdoor illumination, which were complicated images due to shadow, obstacles and walking posture of cow. Sixteen images were selected as the reference image for each cow and 44 query images were used for evaluating the efficiency of individual recognition by matching to each reference image. Run-lengths and positions of runs across speckle area were calculated from 40 horizontal line profiles for ROI (region of interest) in a cow body image after 3 passes of 5$\times$5 median filtering. A similarity measure for recognizing cow individuals was calculated using Euclidean distance of normalized G-frame histogram (GH). normalized speckle run-length (BRL), normalized x and y positions (BRX, BRY) of speckle runs. This study evaluated the efficiency of individual recognition of cow using Recall(Success rate) and AVRR(Average rank of relevant images). Success rate of individual recognition was 100% when GH, BRL, BRX and BRY were used as image query indices. It was concluded that the histogram as global property and the information of speckle runs as local properties were good image features for individual recognition and the developed system of individual recognition was reliable.

Edge Preserving Speckle Reduction of Ultrasound Image with Morphological Adaptive Median Filtering

  • Ryu, Kwang-Ryol;Jung, Eun-Suk
    • Journal of information and communication convergence engineering
    • /
    • 제7권4호
    • /
    • pp.535-538
    • /
    • 2009
  • Speckle noise reduction for ultrasound CT image using morphological adaptive median filtering based on edge preservation is presented in this paper. Speckle noise is multiplicative feature and causes ultrasound image to degrade widely from transducer. An input image is classified into edge region and homogeneous region in preprocessing. The speckle is reduced by morphological operation on the 2D gray scale by using convolution and correlation, and edges are preserved. The adaptive median is processed to reduce an impulse noise to preserve edges. As the result, MAM of the proposed method enhances the image to about 10% in comparison with Winner filter by Edge Preservation Index and PSNR, and 10% to only adaptive median filtering.

웨이브렛 기반 시그마 필터와 에지맵을 이용한 SAR 영상처리 (SAR Image Processing Using Wavelet-based Sigma Filter and Edgemap)

  • 고기영;박철우
    • 한국인터넷방송통신학회논문지
    • /
    • 제9권6호
    • /
    • pp.155-161
    • /
    • 2009
  • SAR영상의 가장 큰 문제점은 경계선 부근에서 스패클(Speckle)잡음을 어떻게 줄이느냐 하는 것이다. 본 논문에서는 제안한 방법을 이용하여 경계선을 보존할 수 있는 효과적인 필터를 개발하고자 한다. 스패클 잡음을 줄이면서 에지 영역에 대한 블러링 없는 영상을 추출하기 위하여 웨이브렛 기반의 sigma 필터를 적용하였다. 실험 결과 에지정보에 대한 블러링을 줄인 출력 영상을 구성하였다. 제안한 방법을 미디언 필터와 비교한 결과, 스패클 잡음을 효과적으로 제거한 우수한 영상을 얻을 수 있었다.

  • PDF

트랜스듀서의 음장 특성을 고려한 초음파 스펙클 패턴의 발생과 해석 (Generation and Analysis of Ultrasound Speckle Patterns considering Acoustic Field Characteristics of Transducer)

  • 박희영;최종호;최종수
    • 전자공학회논문지B
    • /
    • 제28B권10호
    • /
    • pp.822-830
    • /
    • 1991
  • In this paper, we propose a new process for ultrasonic B-mode image considering the sound field effects of a concave circuit focused transducer, and aim to remove the speckle pattern which cause the blurring on boundary in ultrasonic B-mode image. We discuss in detail the conception of speckle pattern generation, and the frequency compounding method which is applied to the process for getting a speckle reduced B-mode image. Through the computer simulation, we define the meaning of speckle region, and show the results of reduced speckle pattern. It is discovered in the results that the frequency compounding method is very effective for boundary detection and that the application of the method is limited by various conditions.

  • PDF