• Title/Summary/Keyword: specific field

Search Result 3,177, Processing Time 0.035 seconds

Transversely isotropic thick plate with two temperature & GN type-III in frequency domain

  • Lata, Parveen;Kaur, Iqbal
    • Coupled systems mechanics
    • /
    • v.8 no.1
    • /
    • pp.55-70
    • /
    • 2019
  • This investigation is focused on the variations in transversely isotropic thick circular plate due to time harmonic thermomechanical sources. The homogeneous thick circular plate in presence and absence of energy dissipation and two temperatures has been considered. Hankel transform is used for solving field equations. The analytical expressions of conductive temperature, displacement components, and stress components are computed in the transformed domain. The effects of frequency at different values are represented graphically. Some specific cases are also figured out from the current research.

Virus Diseases Occurred on Squash in Jeonnam Province (전남지역의 호박에 발생하는 바이러스 병 발생 실태)

  • Ko, Sug-Ju;Lee, Yong-Hwan;Cha, Kwang-Hong;Lee, Su-Heon;Choi, Hong-Soo
    • Research in Plant Disease
    • /
    • v.13 no.1
    • /
    • pp.71-73
    • /
    • 2007
  • Field disease incidences of squash virus diseases in Jeonnam province were estimated to be 76.1% and of delayed planting on August-September (retarding culture) and on February-March (semi-forcing culture) on glass house were 55.0% and 0%, respectively, in 2000. Disease incidences of individual squash plant within a field were 100% and 3.6%, respectively, in wild culture and retarding culture. Total of 61 samples suspected to be infected with viruses were collected in 2000 and tested by RT-PCR using specific oligonulceotide primer sets designed for the detection of Cucumber green mottle mosaic virus (CGMMV), Kyuri green mottle mosaic virus (KGMMV), Zucchini yellow mosaic virus (ZYMV), Papaya ring spot virus (PRSV), Watermelon mosaic virus (WMV), and Cucumber mosaic virus (CMV). Each specific primer set for WMV, ZYMV, and PRSV amplified expected size of DNA fragments from 16, 10, and 2 samples in wild culture, respectively. Double or triple infection were observed in 7 samples tested. In contrast, each specific primer set for WMV, ZYMV, and PRSV confirmed virus infection from 7, 6, and 6 samples, respectively, in samples collected from semi-forcing culture. Double infection of WMV and PRSV was observed in only one sample. However, no DNA fragment was amplified from RT-PCR using CGMMV, KGMMV, and CMV specific oligonucleotide primer sets indicating no CGMMV, KGMMV, or CMV infection in squash fields in Jeonnam province in 2000.

Dynamics of Transverse Magnetic Domain Walls in Rectangular-shape Thin-film Nanowires Studied by Micromagnetic Simulations

  • Lee, Jun-Young;Choi, Sang-Kook;Kim, Sang-Koog
    • Journal of Magnetics
    • /
    • v.11 no.2
    • /
    • pp.74-76
    • /
    • 2006
  • Dynamic behaviors of transverse domain walls (TDWs) in rectangular shaped thin-film magnetic nanowires with different widths under applied magnetic fields less than the Walker field were studied by micromagnetic simulations. It was found that the velocity of stable TDWs in the viscous region increases from 147 to 419 m/s and their mass decreases from $6.24{\times}10^{-23}\;to\;2.70{\times}10^{-23}kg$ with increasing strength of the applied magnetic field ranging from 5 to 20 Oe for the nanowire with a dimension of 10 nm in thickness and $5{\mu}m$ in length, and 50 nm in width. With increasing the width of nanowires from 50 to 125 nm at a specific field strength of 5 Oe, the TDW's velocity also increases from 147 to 246 m/s and its mass decreases from $6.24{\times}10^{-23}\;to\;5.91{\times}10^{-23}kg$.

Waveguide Applicator System for Head and Neck Hyperthermia Treatment

  • Fiser, Ondrej;Merunka, Ilja;Vrba, Jan
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1744-1753
    • /
    • 2016
  • The main purpose of this article is a complex hyperthermia applicator system design for treatment of head and neck region. The applicator system is composed of four waveguides with a stripline horn aperture and circular water bolus. The specific absorption rate (SAR) and temperature distribution from this applicator in various numerical phantom models was investigated. For used targets, the treatment planning based on the optimization process made through the SEMCAD X software is added to show the steering possibilities of SAR and thereby temperature distribution. Using treatment planning software, we proved that the SAR and temperature distribution can be effectively controlled (by amplitude and phase changing) improving the SAR and temperature target coverage approximately by 20 %. For the proposed applicator system analysis and quantitative evaluation of two parameters 25 % iso-SAR and $41^{\circ}C$ iso-temperature contours in the treatment area with the respect to sensitive structures in treatment area were defined. To verify our simulation results, the real measurement of reflectivity coefficient as well as the temperature distribution in a homogenous phantom were performed.

Intravenous Infusion Monitoring Sensor Based on Longitudinal Electric Field Proximity Sensing Technique (종방향 전기장 근접 감지 방식 수액 주입 측정 센서)

  • Kim, Young Cheol;Ahmad, Sheikh Faisal;Kim, Hyun Deok
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.101-106
    • /
    • 2017
  • A novel intravenous (IV) infusion monitoring sensor is presented to measure the drop rate in the drip chamber of an IV infusion set. It is based on a capacitive proximity sensor and detects the variation of the longitudinal electric field induced by the drop falling into the drip chamber. Unlike the conventional capacitor sensor with two semi-cylindrical conductor plates, the proximity sensor for IV monitoring is composed of a pair of conductor rings which are mounted on the outer surface of the drip chamber with a specific gap between them. The characteristics of the proximity sensor for IV monitoring were investigated through three dimensional electrostatic simulations. It showed quite superior performances in comparison with the conventional capacitor sensor. Especially, the proposed proximity sensor exhibits consistent sensitivity regardless of its mounting position on the drip chamber, operates normally though the drip chamber is tilted and shows robustness to the changes of the drop size and the drip factor of the IV infusion set. Thus, the proximity sensor for IV monitoring is more suitable for use in actual environment of IV therapy compared with the conventional capacitor sensor.

Fast Evaluation of Sound Radiation by Vibrating Structures with ACIRAN/AR

  • Migeot, Jean-Louis;Lielens, Gregory;Coyette, Jean-Pierre
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.561-562
    • /
    • 2008
  • The numerical analysis of sound radiation by vibrating structure is a well known and mature technology used in many industries. Accurate methods based on the boundary or finite element method have been successfully developed over the last two decades and are now available in standard CAE tools. These methods are however known to require significant computational resources which, furthermore, very quickly increase with the frequency of interest. The low speed of most current methods is a main obstacle for a systematic use of acoustic CAE in industrial design processes. In this paper we are going to present a set of innovative techniques that significantly speed-up the calculation of acoustic radiation indicators (acoustic pressure, velocity, intensity and power; contribution vectors). The modeling is based on the well known combination of finite elements and infinite elements but also combines the following ingredients to obtain a very high performance: o a multi-frontal massively parallel sparse direct solver; o a multi-frequency solver based on the Krylov method; o the use of pellicular acoustic modes as a vector basis for representing acoustic excitations; o the numerical evaluation of Green functions related to the specific geometry of the problem under investigation. All these ingredients are embedded in the ACTRAN/AR CAE tool which provides unprecedented performance for acoustic radiation analysis. The method will be demonstrated on several applications taken from various industries.

  • PDF

Evaluation and Estimation of Sediment Yield under Various Slope Scenarios at Jawoon-ri using WEPP Watershed Model (WEPP Watershed Version을 이용한 홍천군 자운리 농경지의 경사도에 따른 토양유실량 평가)

  • Choi, Jae-Wan;Lee, Jae-Woon;Lee, Yeoul-Jae;Hyun, Geun-Woo;Lim, Kyoung-Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.693-697
    • /
    • 2009
  • Physically-based WEPP watershed version was applied to a watershed, located at Jawoon-ri, Gangwon with very detailed rainfall data, rather than daily rainfall data. Then it was validated with measured sediment data collected at the sediment settling ponds and through overland flow. The $R^2$ and the EI for runoff comparisons were 0.88 and 0.91, respectively. For sediment comparisons, the $R^2$ and the EI values were 0.95 and 0.91. Since the WEPP provides higher accuracies in predicting runoff and sediment yield from the study watershed, various slope scenarios (2%, 3%, 5.5%, 8%, 10%, 13%, 15%, 18%, 20%, 23%, 25%, 28%, 30%) were made and simulated sediment yield values were analyzed to develop appropriate soil erosion management practices. It was found that soil erosion increase linearly with increase in slope of the field in the watershed. However, the soil erosion increases dramatically with the slope of 20% or higher. Therefore special care should be taken for the agricultural field with higher slope of 20% or higher. As shown in this study, the WEPP watershed version is suitable model to predict soil erosion where torrential rainfall events are causing significant amount of soil loss from the field and it can also be used to develop site-specific best management practices.

  • PDF

Acceptable Velocity Errors Tolerance For Field Artillery Weapon System (야전포병 무기체계의 속도오차 허용한계)

  • Min Kye-Ryo;Bai Do-Sun
    • Journal of the military operations research society of Korea
    • /
    • v.2 no.1
    • /
    • pp.163-176
    • /
    • 1976
  • The artillery fire is characterized by great damage that can be inflicted simultaneously to an area through concentrated firing. The field artillery guns used in R.O.K. Army are generally old. Thus high values of their velocity errors cause wide dispersion of shell landings. Therefore effects of the concentrated firing is lessened. In this paper a general model which considers all error factors involved in firing in general, is established first. Then from this a basic model which includes the errors involved in concentrated firing only, such as the ballistic error, velocity error, target density function, and damage function, is extracted. Among many weapon systems now in use a specific one called gun 'A' is selected and its concentration effects are measured through computer simulation. The results show that as the velocity error of a battery increases, its target coverage capability, i. e. concentration effect, decreases. Therefore the need arises for the field artillery commander to know beforehand characteristics, i.e. velocity errors, of the guns in his unit and also to carefully examine the problem of battery arrangement with the gun characteristics in mind in order to maximize the damage effects of his artillery unit.

  • PDF

Performance Comparison of Gas Leak Region Segmentation Based on Transfer Learning (Transfer Learning 기법을 이용한 가스 누출 영역 분할 성능 비교)

  • Marshall, Marshall;Park, Jang-Sik;Park, Seong-Mi
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.481-489
    • /
    • 2020
  • Safety and security during the handling of hazardous materials is a great concern for anyone in the field. One driving point in the security field is the ability to detect the source of the danger and take action against it as quickly as possible. Via the usage of a fully convolutional network, it is possible to create the label map of an input image, indicating what object is occupying the specific area of the image. This research employs the usage of U-net, which was constructed in biomedical field segmentation to segment cells, instead of the original FCN. One of the challenges that this research faces is the availability of ground truth with precise labeling for the dataset. Testing the network after training resulted in some images where the network pronounces even better detail than the expected label map. With better detailed label map, the network might be able to produce better segmentation is something to be studied in further research.