• 제목/요약/키워드: special silicone

검색결과 15건 처리시간 0.023초

Effect of 41℃ deep heat formed by vacuum heating on various pain: Dr.Pakk (Dr. 팍) for pain care

  • Chang, Tae-soun
    • 셀메드
    • /
    • 제12권4호
    • /
    • pp.16.1-16.2
    • /
    • 2022
  • Treatment of patients with pain is directed at relieving pain and restoring function. Heat therapy has been used as a pain treatment. The mean temperatures were 40 and 41℃. Our device, Dr.Pakk heats special silicone to 41℃ with far-infrared rays and attaches it to the painful knee using a vacuum to show the effect. The core technology of the Dr.Pakk is that deep heat is generated when the heat is transmitted deeply by attaching it to the skin. In our experience, Dr.Pakk can be especially effective for knee pain.

광섬유 브래그 격자를 이용한 촉각 센서용 유연 단축 힘 센서의 개발 및 평가 (Development of Flexible Force Sensor Using Fiber Bragg Grating for Tactile Sensor and Its Evaluation)

  • 허진석;이정주
    • 한국정밀공학회지
    • /
    • 제23권2호
    • /
    • pp.51-56
    • /
    • 2006
  • This paper shows the development of flexible force sensor using the fiber Bragg grating. This force sensor consists of a Bragg grating fiber and flexible silicone rubber (DC184, Dow corning co. Ltd). This sensor does not have special structure to maximize the deflection or elongation, but have good sensitivity and very flexible characteristics. In addition, this sensor has the immunity to the electro magnetic field and can be multiplexed easily, which is inherited from the characteristics of fiber Bragg grating sensor. In the future, this sensor can be utilized the tactile sensor system minimizing the sensor size and developing the fabrication method.

물세탁과 드라이클리닝의 세탁성능과 형태안정성 비교 (A comparison of detergency and dimensional stability between wet cleaning and dry cleaning)

  • 곽수경;김아리;오화원;박명자
    • 한국의상디자인학회지
    • /
    • 제21권1호
    • /
    • pp.181-189
    • /
    • 2019
  • The washability, redeposition, fill power, and fabric damage of wet cleaning and dry cleaning solvents were measured to identify the optimal type of washing that would increase washability while maintaining dimensional stability. The soiled fabric is a polyester cotton blend and the types of soil were wine, blood, make-up and sebum with carbon black. Petroleum and silicone solvents were used in dry cleaning. Results from this study are as follows. First, detergency is significantly influenced by the type of washing and type of soil. Wet cleaning is superior to dry cleaning. Wet cleaning shows a strong washing performance against hydrophilic soils, whereas, dry cleaning is stronger against hydrophobic soils. Second, redeposition is significantly affected by the type of washing, fabrics, and soils. Redeposition occurred little on cotton during wet cleaning, but showed a high rate for nylon. However, when the two types of fabric were dry cleaned, redeposition occurred on both types. Third, the fill power of duck-down is very affected by the type of washing. Resilience is the best in wet cleaning; and in dry cleaning, petroleum solvents showed a higher resilience when as compared to silicone solvents. Last, the level of fabric damage to cotton fabrics is highly influenced by the type of washing. Wet cleaning damages cotton fabrics significantly more than dry cleaning. For dry cleaning, petroleum solvents damage these fabrics slightly more than silicone solvents. In conclusion, the type of soil must initially be identified to determine the optimal type of washing. Special caution is required when textiles with particulate soil and nylon are washed. When considering the resilience of duck-down clothing, wet cleaning is more appropriate than dry cleaning. Dry cleaning, especially when using silicone-based solvents, is more suitable than wet cleaning for maintaining the shape of clothing.

X-Band용 전파흡수체의 개발 (Development of Electromagnetic wave Absorbers for X-Band)

  • 김동일;옥승민;문상현;신승재;송재만
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 I
    • /
    • pp.306-309
    • /
    • 2003
  • Carbon uses included (32 wt %) Silicone Rubber, use different composition and thickness and investigated effect and special quality that get to electromagnetic absorber to sintering style Ba Ferrite that have composition of Fe$_2$O$_3$: $Ba_2$CO$_3$= 82.1 : 17.9 wt% to develop high efficiency X-Band electric wave absorber

  • PDF

건축물 벽체용 문양거푸집 개발을 통한 의장콘크리트의 표면광택 특성 (Properties of Surface Grossing on the Design-Concreat by Developing of Design-Forms for Building Wall)

  • 오중근;공민호;조상영;정근호;정상진;정재영
    • 한국건축시공학회지
    • /
    • 제3권1호
    • /
    • pp.131-138
    • /
    • 2003
  • Contemporary architecture calls for a wide range of surface textures and treatments. A surface compatible with the architect's design may vary from a glass-smooth finish to one requiring special sculptured ornamentation. These surfaces require many different types of form sheathing and lining. The purpose of study is development of new design form and made elaborateness shape. Architecture finish material not used expenses working hours, personnel expenses, architecture finish material cost. After this, building wall apply a variety shape in concrete surface and Easy to used in field.

건축벽체용 의장콘크리트 개발에 관한 기초적 연구 (The Fundamental Study on Development of Design-Concrete used Building Wall)

  • 임현준;정근호;김우재;김성식;정재영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술논문발표회
    • /
    • pp.27-30
    • /
    • 2002
  • Contemporary architecture calls for a wide range of surface textures and treatments. A surface compatible with the architect's design may vary from a glass-smooth finish to one requiring special sculptured ornamentation. These surfaces require many different types of form sheathing and lining. The purpose of study development new design form and made elaborateness shape. Easy to used in field that architecture finish material not used expect effective reduce of working hours, personnel expenses, architecture finish material, cost. After this, building wall apply a variety shape in concrete surface.

  • PDF

당뇨발을 위한 생체역학적 치료방법들에 관한 고찰 (A Review of Biomechanical Treatments for the Diabetic Foot)

  • 고은경;정도영
    • The Journal of Korean Physical Therapy
    • /
    • 제19권5호
    • /
    • pp.51-63
    • /
    • 2007
  • Diabetic foot ulcers result from abnormal mechanical loading of the foot, such as repetitive pressure applied to the plantar aspect of the foot while walking. Diabetic peripheral neuropathy causes changes in foot structure, affecting foot function and subsequently leading to increased plantar foot pressure, which is a predictive risk factor for the development of diabetic foot ulceration. To early identify the insensitive foot makes it possible to prevent diabetic foot ulceration and to protect the foot at risk from abnormal biomechanical loading. Abnormal foot pressures can be reduced using several different approaches, including callus debridement, prescription of special footwear, foot orthosis. injection of liquid silicone, Achilles tendon lengthening, and so forth. Off-loading of the diabetic wound is a key factor to successful wound healing as it is associated with reduced inflammatory and accelerated repair processes. Pressure relief can be achieved using various off-loading modalities including accommodative dressing, walking splints, ankle-foot orthosis, total contact cast, and removable and irremovable cast walkers.

  • PDF

철도차량용 견인전동기의 절연설계 및 절연시스템 구성 (Design & system construction of insulation on the traction motor for EMU)

  • 왕종배;홍선호;조연옥;김명룡
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.194-197
    • /
    • 2001
  • Traction motors driven by high speed switching inverters is demanded higher operating temperature, severe duty cycles, higher starting current, frequent voltage transients and finally severe environmental exposure. For applications to inverter duty, traction motors needs a special insulation system, which has characteristics of increased bond strength, lower operating temperature and higher turn-to-turn insulation. In this paper, design considerations and manufacturing procedure of 200 Class insulation system with polyimde(Kapton) main insulation and silicone resin VPI process on the traction motor for EMU will be reviewed. And performance test and long life evaluation test which prove stability and long life evaluation test which prove stability and reliability of insulation system for traction motor will be introduced.

  • PDF

Influence of the material for preformed moulds on the polymerization temperature of resin materials for temporary FPDs

  • Pott, Philipp-Cornelius;Schmitz-Watjen, Hans;Stiesch, Meike;Eisenburger, Michael
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.294-301
    • /
    • 2017
  • PURPOSE. Temperature increase of $5.5^{\circ}C$ can cause damage or necrosis of the pulp. Increasing temperature can be caused not only by mechanical factors, e.g. grinding, but also by exothermic polymerization reactions of resin materials. The aim of this study was to evaluate influences of the form material on the intrapulpal temperature during the polymerization of different self-curing resin materials for temporary restorations. MATERIALS AND METHODS. 30 provisonal bridges were made of 5 resin materials: Prevision Temp (Pre), Protemp 4 (Pro), Luxatemp Star (Lux), Structure 3 (Str) and an experimental material (Exp). Moulds made of alginate (A) and of silicone (S) and vacuum formed moulds (V) were used to build 10 bridges each on a special experimental setup. The intrapulpal temperatures of three abutment teeth (a canine, a premolar, and a molar,) were measured during the polymerization every second under isothermal conditions. Comparisons of the maximum temperature ($T_{Max}$) and the time until the maximum temperature ($t_{TMax}$) were performed using ANOVA and Tukey Test. RESULTS. Using alginate as the mould material resulted in a cooling effect for every resin material. Using the vacuum formed mould, $T_{Max}$ increased significantly compared to alginate (P<.001) and silicone (P<.001). In groups Lux, Pro, and Pre, $t_{TMax}$ increased when the vacuum formed moulds were used. In groups Exp and Str, there was no influence of the mould material on $t_{TMax}$. CONCLUSION. All of the mould materials are suitable for clinical use if the intraoral application time does not exceed the manufacturer's instructions for the resin materials.

의치상 레진과 이장 레진 간의 결합강도 비교 (Comparison of bond strength between denture base resin and reline resin)

  • 금영희;김부섭
    • 대한치과기공학회지
    • /
    • 제39권3호
    • /
    • pp.161-167
    • /
    • 2017
  • Purpose: We compare the bond strength of heat-cured PMMA of Lucitone 199 and QC-20 and Tokuyama Rebase Resin of self-cured resin, which are widely used and well accepted in clinical practice. In order to test the mechanical bonding and chemical bonding, we will compare the bond strength between EstheShot Bright, Smiletone, Repair and Rebase resins. Methods: The denture base resin used in this study was PMMA heat-cured QC-20 and Lucitone 199, polyamide resin EstheShot Bright, Smiletone. And Two types of self-curing Rapid Repair and Tokuyama Rebase were used as resection resins. To measure the bond strength, the denture specimens were fabricated in the size of $10{\times}64{\times}3.5mm$ as instructed by the manufacturer. A surface treatment agent was applied to the cut surfaces of each denture specimen, and the specimens were placed in a preformed silicone mold, and autoclaved excimer resins were prepared. The bending strength of the fabricated specimens was measured using a universal testing machine (STM-5, United Calibration Co., U.S.A.) to measure the three-point bending strength. Results: In both polycarbonate and polyacetal resin, a special resin surface treatment agent showed higher bonding strength than the resin surface treatment agent(p<0.05). Regardless of the type of surface treatment, polycarbonate showed higher bond strength than polyacetal resin(p<0.05). Conclusion: It is considered desirable to use a special surface treating agent for the thermoplastic denture base resin such as polycarbonate and polyacetal resin.