• Title/Summary/Keyword: spatial light modulation

Search Result 45, Processing Time 0.025 seconds

Holographic optical memory by phase-modulation multiplexing (새로운 위상변조 다중화를 이용한 홀로그램 중첩기록 및 재생)

  • 손승대;고재량;이연호
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.6
    • /
    • pp.473-481
    • /
    • 1999
  • We propose a new scheme of hologram multiplexing that can improve the crosstalk noise in the conventional phase-code multiplexing. Our method is based on the idea that the separate holograms to be stored in a certain region of the photorefractve material should have relative phase other than $180^{\circ}$. To demonstrate the new idea we fabricate a phase spatial light modulator using piezo-electric material. The experimental result shows that the crosstalk noise in the restored holograms is reduced much in our method. We also computer simulate the hologram multiplexing and compare the result with the experimental data.l data.

  • PDF

Realization of 3-D Topographic and Tomograpic Images with Ultrahigh-resolution Full-field Optical Coherence Tomography

  • Choi, Woo-June;Na, Ji-Hoon;Ryu, Seon-Young;Lee, Byeong-Ha;Ko, Dong-Seob
    • Journal of the Optical Society of Korea
    • /
    • v.11 no.1
    • /
    • pp.18-25
    • /
    • 2007
  • We present an ultrahigh-resolution full-field optical coherence tomography (FF-OCT) implemented with a white-light interference microscope and a detector array as an alternative OCT technique. The use of detector array allows the capture of two-dimensional en-face images in parallel without taking any lateral scanning process. The phase shifting interferometric technique with the sinusoidal phase modulation (SPM) is utilized to get the demodulated OCT images. The configuration of the system and the resolution of the obtained image are presented. The topographic images, taken with the implemented system, of a coin, an integrated circuit chip, and the tomographic images of an onion epithelium are demonstrated also. Axial and lateral spatial resolution of ${\sim}1.0{\mu}m$ and ${\sim}2.0{\mu}m$ are achieved with the system respectively.

Optical Design of a Reflecting Omnidirectional Vision System for Long-wavelength Infrared Light (원적외선용 반사식 전방위 비전 시스템의 광학 설계)

  • Ju, Yun Jae;Jo, Jae Heung;Ryu, Jae Myung
    • Korean Journal of Optics and Photonics
    • /
    • v.30 no.2
    • /
    • pp.37-47
    • /
    • 2019
  • A reflecting omnidirectional optical system with four spherical and aspherical mirrors, for use with long-wavelength infrared light (LWIR) for night surveillance, is proposed. It is designed to include a collecting pseudo-Cassegrain reflector and an imaging inverse pseudo-Cassegrain reflector, and the design process and performance analysis is reported in detail. The half-field of view (HFOV) and F-number of this optical system are $40-110^{\circ}$ and 1.56, respectively. To use the LWIR imaging, the size of the image must be similar to that of the microbolometer sensor for LWIR. As a result, the size of the image must be $5.9mm{\times}5.9mm$ if possible. The image size ratio for an HFOV range of $40^{\circ}$ to $110^{\circ}$ after optimizing the design is 48.86%. At a spatial frequency of 20 lp/mm when the HFOV is $110^{\circ}$, the modulation transfer function (MTF) for LWIR is 0.381. Additionally, the cumulative probability of tolerance for the LWIR at a spatial frequency of 20 lp/mm is 99.75%. As a result of athermalization analysis in the temperature range of $-32^{\circ}C$ to $+55^{\circ}C$, we find that the secondary mirror of the inverse pseudo-Cassegrain reflector can function as a compensator, to alleviate MTF degradation with rising temperature.

Optical Design of a Modified Catadioptric Omnidirectional Optical System for a Capsule Endoscope to Image Simultaneously Front and Side Views on a RGB/NIR CMOS Sensor (RGB/NIR CMOS 센서에서 정면 영상과 측면 영상을 동시에 결상하는 캡슐 내시경용 개선된 반사굴절식 전방위 광학계의 광학 설계)

  • Hong, Young-Gee;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.6
    • /
    • pp.286-295
    • /
    • 2021
  • A modified catadioptric omnidirectional optical system (MCOOS) using an RGB/NIR CMOS sensor is optically designed for a capsule endoscope with the front field of view (FOV) in visible light (RGB) and side FOV in visible and near-infrared (NIR) light. The front image is captured by the front imaging lens system of the MCOOS, which consists of an additional three lenses arranged behind the secondary mirror of the catadioptric omnidirectional optical system (COOS) and the imaging lens system of the COOS. The side image is properly formed by the COOS. The Nyquist frequencies of the sensor in the RGB and NIR spectra are 90 lp/mm and 180 lp/mm, respectively. The overall length of 12 mm, F-number of 3.5, and two half-angles of front and side half FOV of 70° and 50°-120° of the MCOOS are determined by the design specifications. As a result, a spatial frequency of 154 lp/mm at a modulation transfer function (MTF) of 0.3, a depth of focus (DOF) of -0.051-+0.052 mm, and a cumulative probability of tolerance (CPT) of 99% are obtained from the COOS. Also, the spatial frequency at MTF of 170 lp/mm, DOF of -0.035-0.051 mm, and CPT of 99.9% are attained from the front-imaging lens system of the optimized MCOOS.

Research of Non-integeral Spatial Interpolation for Precise Identifying Soybean Location under Plastic Mulching

  • Cho, Yongjin;Yun, Yeji;Lee, Kyou-seung;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.156-156
    • /
    • 2017
  • Most crop damages have been occurred by vermin(e.g., wild birds and herbivores) during the period between seeding and the cotyledon level. In this study, to minimize the damage by vermin and acquire the benefits such as protection against weeds and maintenance of water content in soil, immediately vinyl mulching after seeding was devised. Vinyl mulching has been generally covered with black color vinyl, that crop seeding locations cannot be detected by visible light range. Before punching vinyl, non-contact and non-destructive methods that can continuously determine the locations are necessary. In this study, a crop position detection method was studied that uses infrared thermal image sensor to determine the cotyledon position under vinyl mulch. The moving system for acquiring image arrays has been developed for continuously detecting crop locations under plastic mulching on the field. A sliding mechanical device was developed to move the sensor, which were arranged in the form of a linear array, perpendicular to the array using a micro-controller integrated with a stepping motor. The experiments were conducted while moving 4.00 cm/s speed of the IR sensor by the rotational speed of the stepping motor based on a digital pulse width modulation signal from the micro-controller. The acquired images were calibrated with the spatial image correlation. The collected data were processed using moving averaging on interpolation to determine the frame where the variance was the smallest in resolution units of 1.02 cm. For this study, the spline method was relatively faster than the other polynomial interpolation methods, because it has a lower maximum order of formulation when using a system such as the tridiagonal linear equation system which provided the capability of real-time processing. The temperature distribution corresponding to the distance between the crops was 10 cm, and the more clearly the leaf pattern of the crop was visually confirmed. The frequency difference was decreased, as the number of overlapped pixels was increased. Also the wave pattern of points where the crops were recognized were reduced.

  • PDF

Optical Design of a Subminiature Catadioptric Omnidirectional Optical System with an LED Illumination System for a Capsule Endoscope (LED 조명계를 결합한 캡슐내시경용 초소형 반사굴절식 전방위 광학계의 설계)

  • Moon, Tae Sung;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.2
    • /
    • pp.68-78
    • /
    • 2021
  • A subminiature catadioptric omnidirectional optical system (SCOOS) with 2 mirrors, 6 plastic aspherical lenses, and an illumination system of 6 light emitting diodes, to observe the 360° panoramic image of the inner intestine, is optically designed and evaluated for a capsule endoscope. The total length, overall length, half field of view (HFOV), and F-number of the SCOOS are 14.3 mm, 8.93 mm, 51°~120°, and 3.5, respectively. The optical system has a complementary metal-oxide-semiconductor sensor with 0.1 megapixels, and an illumination system of 6 light-emitting diodes (LEDs) with 0.25 lm to illuminate on the 360° side view of the intestine along the optical axis. As a result, the spatial frequency at the modulation transfer function (MTF) of 0.3, the depth of focus, and the cumulative probability of tolerance at the Nyquist frequency of 44 lp/mm and MTF of 0.3 of the optimized optical system are obtained as 130 lp/mm, -0.097 mm to +0.076 mm, and 90.5%, respectively. Additionally, the simulated illuminance of the LED illumination system at the inner surface of the intestine within HFOV, at a distance of 15.0 mm from the optical axis, is from a minimum of 315 lx to a maximum of 725 lx, which is a sufficient illumination and visibility.

Characteristics of CCD Based Optical CT Scanner for Therapeutic Radiation Dosimetry (치료방사선량평가를 위한 CCD 기반 광학컴퓨터단층촬영 스캐너의 특성)

  • Lee, Jae Choon;Kim, Ae Ran;Ji, Young Hoon;Kwon, Soo-Il
    • Progress in Medical Physics
    • /
    • v.27 no.2
    • /
    • pp.72-78
    • /
    • 2016
  • A CCD camera and an LED light source were combined to fabricate a compact optical CT scanner for the therapeutic radiation dose evaluation of a polymer gel dosimeter. After the collimated beam emitted by the LED passed through aquarium, gel phantom, and telecentric lens, an image was collected by the CCD camera and reconstructed using MATLAB. By using a stepping motor and LabVIEW, the gel dosimeter was rotated at every $0.72^{\circ}$, and the time for collecting 500 slice images per a revolution was within 20 min. At a spatial frequency of 4.5 lp/mm of the optical CT scanner, the modulation transfer function value was 72%. The linear correlation coefficient of the optical CT scanner for the polymer gel dosimeter was 0.987.

Design and Performance of a Catadioptric Omnidirectional Zoom Optical System Using a Hybrid Lens for Visible Light (가시광에서 하이브리드 렌즈를 사용한 반사굴절식 전방위 줌 광학계의 설계 및 성능평가)

  • Park, Hyun Sik;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.31 no.2
    • /
    • pp.96-104
    • /
    • 2020
  • A catadioptric omnidirectional zoom optical system using a hybrid lens (COZOSH) that performs simultaneously two functions of a lens and a mirror was designed at the visible wavelength range for daytime unmanned surveillance, and its performance was analyzed. The hybrid lens has lots of advantages in terms of fabrication and assembly of a COZOSH, because of the obviation of a lens boring process and reduction of the number of optical components. Additionally, we designed the COZOSH to expand the compressed inner-image region of a donut image at low spatial frequencies. As a result, the optimized design performance of the optical system that satisfies all initial design specifications was obtained from calculation of the modulation transfer function, spot diagram, and tolerance analysis. We confirmed that the COZOSH is a passively athermalized optical system under conditions of temperature variation from -30℃ to 50℃, by using athermalization analysis during zooming.

A Ghost-Imaging System Based on a Microfluidic Chip

  • Wang, Kaimin;Han, Xiaoxuan;Ye, Hualong;Wang, Zhaorui;Zhang, Leihong;Hu, Jiafeng;Xu, Meiyong;Xin, Xiangjun;Zhang, Dawei
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.147-154
    • /
    • 2021
  • Microfluidic chip technology is a research focus in biology, chemistry, and medicine, for example. However, microfluidic chips are rarely applied in imaging, especially in ghost imaging. Thus in this work we propose a ghost-imaging system, in which we deploy a novel microfluidic chip modulator (MCM) constructed of double-layer zigzag micro pipelines. While in traditional situations a spatial light modulator (SLM) and supporting computers are required, we can get rid of active modulation devices and computers with this proposed scheme. The corresponding simulation analysis verifies good feasibility of the scheme, which can ensure the quality of data transmission and achieve convenient, fast ghost imaging passively.

Proof-of-principle Experimental Study of the CMA-ES Phase-control Algorithm Implemented in a Multichannel Coherent-beam-combining System (다채널 결맞음 빔결합 시스템에서 CMA-ES 위상 제어 알고리즘 구현에 관한 원리증명 실험적 연구)

  • Minsu Yeo;Hansol Kim;Yoonchan Jeong
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.3
    • /
    • pp.107-114
    • /
    • 2024
  • In this study, the feasibility of using the covariance-matrix-adaptation-evolution-strategy (CMA-ES) algorithm in a multichannel coherent-beam-combining (CBC) system was experimentally verified. We constructed a multichannel CBC system utilizing a spatial light modulator (SLM) as a multichannel phase-modulator array, along with a coherent light source at 635 nm, implemented the stochastic-parallel-gradient-descent (SPGD) and CMA-ES algorithms on it, and compared their performances. In particular, we evaluated the characteristics of the CMA-ES and SPGD algorithms in the CBC system in both 16-channel rectangular and 19-channel honeycomb formats. The results of the evaluation showed that the performances of the two algorithms were similar on average, under the given conditions; However, it was verified that under the given conditions the CMA-ES algorithm was able to operate with more stable performance than the SPGD algorithm, as the former had less operational variation with the initial phase setting than the latter. It is emphasized that this study is the first proof-of-principle demonstration of the CMA-ES phase-control algorithm in a multichannel CBC system, to the best of our knowledge, and is expected to be useful for future experimental studies of the effects of additional channel-number increments, or external-phase-noise effects, in multichannel CBC systems based on the CMA-ES phase-control algorithm.