• Title/Summary/Keyword: span number

Search Result 550, Processing Time 0.028 seconds

Estimation of Demand on Bulk-Type Dryer for Agricultural Products in Korea (농산물(農産物) 건조기(乾燥機)(벌크형)의 수요추정(需要推定)에 관(關)한 조사(調査) 연구(硏究) -고추 및 엽연초(葉煙草)를 대상(對象)으로)

  • Koh, H.K.;Noh, S.H.;Cho, Y.J.
    • Journal of Biosystems Engineering
    • /
    • v.13 no.2
    • /
    • pp.51-62
    • /
    • 1988
  • Bulk-type dryers which are widely used for drying special agricultural products such as tobaco leaf, red pepper, mushroom, ginseng, medicinal herb, etc, began to be distributed on a full scale since 1980 and the total number of dryers introduced to farms reached to about 36,600 units as of the end of 1986. In this study a survery was carried on the farmers cultivating special crops, dryer manufacturers and related administrative institutes and associations by means of on-the-spot investigation, mail or interview to collect data on scales and patterns of farming, utilization of bulk-type dryers, production and price streams of the special crops etc. Based on the analysis of the data surveyed predictions were made for the total demand on the bulk-type dryers and for annual demand over five-year span.

  • PDF

Recursive Nullspace Calculation for Multiuser MIMO Systems (다중 사용자 MIMO 시스템을 위한 순차적 영공간 계산)

  • Joung, Jin-Gon;Lee, Yong-Hoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.12A
    • /
    • pp.1238-1243
    • /
    • 2007
  • The computational complexity for the zero-forcing (ZF)-based multiuser (MU) multiple-input multiple-output(MIMO) preprocessing matrices can be immoderately large as the number of transmit antennas or users increases. In this paper, we show that the span of singular vector space of a matrix can be obtained from the singular vectors of the parted rows of that matrix with computational saving and propose a computationally efficient recursive-algorithm for achieving the ZF-based preprocessing matrices. Analysis about the complexities shows that a new recursive-algorithm can lighten the computational load.

Detemination of Tower Skeleton Diagram for KEPCO 765kV Transmission Lines (765kv 송전용 철탑 Skeleton Diagram 결정)

  • Park, K.H.;Kim, Y.W.;Won, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1804-1806
    • /
    • 1997
  • Route conditions, applied voltage and the condition of stringing conductors should be considered in determining standard types and skeleton diagrams of towers. In skeleton diagrams the necessary number of insulators and the air clearance have been decided by the results of studies on insulation coordination. Galloping, sleet-jumping, sag characteristics and the possibility of closeness of conductors should be considered according to the condition of stringing conductor and the span. After reviewing those factors, it is necessary to determine the minimum vertical and horizontal distance for the safety of transmission lines under any circumstances. Also it should be economical.

  • PDF

Verified 20-car Model of High-speed Train for Dynamic Response Analysis of Railway Bridges (검증된 고속철도 차량의 20량편성 정밀모형에 의한 철도교량의 동적응답 분석)

  • 김상효;김병석;허진영;최성락
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2001.10a
    • /
    • pp.485-492
    • /
    • 2001
  • The dynamic analysis model is developed with the high-speed train (KTX) and a 2-span continuous prestressed concrete box girder bridge with a double track. The analytical results are compared with the dynamic field test results and found to be valid to yield quite accurate dynamic responses. The various trainset models with different number of cars are developed and compared with the results of the regular 20-car trainset model. It is concluded that the reduced trainset models, such as 7-car and 10-car models, cannot exactly produce the dynamic responses of bridges, especially when the train speed is high. Under the coincidence condition of two trains traveling with resonance velocity in the opposite directions, it is found that the impact factor under two-way coincidence is three times larger than that under one-way traffic. Consequently, for the bridge with a double-track it is necessary to check not only the dynamic responses of the bridge with one-way traffic but those with two-way coincidence.

  • PDF

Shear-Fatigue Behavior of High-Strength Reinforced Concrete Beams under Repeated Loading (반복하중을 받는 고강도 철근콘크리트 보의 전단피로 거동)

  • 곽계환
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.4
    • /
    • pp.92-103
    • /
    • 1999
  • Recently structural damage has been frequently observed in reinforced concrete brdiges due to repeated loads such as vehicular traffic an due to continual overloads by heavy duty trucks. Therefore, the purpose of this experimental stduy is to investigate the damage mechanism due to fatigue behavior of high-strength reinforced concrete beams under repeated loads. From the test results, the relation of cycle loading to deflection is on the mid-span , the crack growth and the modes of failure according to cycle number, fatigue life and S-N curve were observed through the fatigue test. Based on the fatigue test results , high-strength reinforced concrete beams failed to 57 ∼66 percent of the static ultimate strength . Fatigue strength aobut two million cycles from S-N curves was certified by 60 percent of static ultimate strength.

  • PDF

Design Method for Continuous IPC Girder bridges (IPC 거더의 연속화 설계 방안)

  • 한만엽;황의승;박준범
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1007-1012
    • /
    • 2000
  • This study is to present a design method using continuous tendons in IPC girders. Present design methods use just concrete to make continuity between girders. In these design methods cracks occur in almost every joint area of girders. This means that these girders act as simple beam instead of continuous beams. The design method which is presented here uses continuous tendons between girders. In this method the cracks could be restrained. So the girders behave as continuous beams, which this method allows the span length gets longer than simple girders and also the section height could get lower. In this way the number of piers and the weight of super structure could be reduced which means the construction cost could also be reduced.

Load Bearing Capacity Evaluation of Continuous IPC Girder Bridge. (IPC 거더 연속교의 실교량 내하력 평가 연구)

  • Han, Man-Yop;Hwang, Eu-Seung;Jin, Kyung-Seok;Kang, Sang-Hoon;Shin, Jae-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.475-478
    • /
    • 2005
  • This study was performed to evaluate about load bearing capacity of continuos IPC Girder Bridge under and after Construction. This is Ichi-1 Bridge that is 2-40m span continuous bridge on a extension road through the Ichun and the Naesa. The result of static loading test to use a 25ton truck after construction, deflection ratio is 0.64 that is $35\%$ and average of response ratio is 0.48$\~$0.89 that is less than theoretical value. The result of dynamic loading test, the number of proper vibrations is 3.06Hz that is like theoretical value 3.61Hz, the modulus of impact is 0.235 that is bigger than specification 0.19. the load bearing capacity is minimum DB-40 that is so big value. In the result, continuos IPC Girder Bridge is safe in short period. we will evaluate long period behavior of continuos IPC Girder Bridge.

  • PDF

Effects of damping ratio on dynamic increase factor in progressive collapse

  • Mashhadi, Javad;Saffari, Hamed
    • Steel and Composite Structures
    • /
    • v.22 no.3
    • /
    • pp.677-690
    • /
    • 2016
  • In this paper, the effect of damping ratio on nonlinear dynamic analysis response and dynamic increase factor (DIF) in nonlinear static analysis of structures against column removal are investigated and a modified empirical DIF is presented. To this end, series of low and mid-rise moment frame structures with different span lengths and number of storeys are designed and the effect of damping ratio in DIF is investigated, performing several nonlinear static and dynamic analyses. For each damping ratio, a nonlinear dynamic analysis and a step by step nonlinear static analysis are carried out and the modified empirical DIF formulas are derived. The results of the analysis reveal that DIF is decreased with increasing damping ratio. Finally, an empirical formula is recommended that relates to damping ratio. Therefore, the new modified DIF can be used with nonlinear static analysis instead of nonlinear dynamic analysis to assess the progressive collapse potential of moment frame buildings with different damping ratios.

Mechanical behavior of concrete comprising successively recycled concrete aggregates

  • Verma, Surender K.;Ashish, Deepankar K.
    • Advances in concrete construction
    • /
    • v.5 no.4
    • /
    • pp.303-311
    • /
    • 2017
  • The concrete industry of developing countries like India consumes majority of natural resources. The increase in population has necessitated the construction of more and more structures. Further many structures have completed their life span or have undergone damages thus warranting the demolition of these structures. India produces approximately 23.75 million tons of recycled concrete aggregate (RCA) annually. The natural resources are depleting at a higher rate with the increasing demand of concrete industry. This difficulty can be reduced with the use of RCA in land fill and concrete manufacturing. Use of RCA can provide cost savings and better energy utilization. This paper presents mechanical behavior of concrete comprising successively recycled concrete aggregate. Mechanical properties of recycled concrete get affected with number of recycling. In mix design successive recycled concrete aggregate (SRCA) was used in place of natural aggregates (NA) with 100% replacement. The test results of the compressive, flexural strength and pulse velocity were obtained for 14 and 28 days of curing age which showed significant improvement in results.

The bridge behavior analysis by means of time history analysis according to the railway velocity (시간이력해석을 이용한 철도 주행속도에 따른 교량의 거동분석)

  • Lee Jong-seon;Lee Jae-Yeol;Hwang Nag-yeon;Kim Kyoung-Nam;Jung Kyoung-Sup
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.368-375
    • /
    • 2003
  • Now a days, the fabrication and election skills have improved in Korea. Due to taking the vertical clearance and a point of beauty, the election of the suspension and the cable-stayed bridges whose span length can be lengthened have been increased. Accordingly, there are link areas between the bridges by cables and other bridges. These dynamic behaviors are different from others. When the vehicles and trains run on the link area, the member force and the fatigue behavior which are occurred to the structure have different values depend on the velocity. On this paper, we analyze the bridge behavior by means of the tine history analysis depend on to velocity, the number of vehicles, single and double way.

  • PDF