• Title/Summary/Keyword: spalling

Search Result 470, Processing Time 0.027 seconds

Investigation of Spalling Mechanism in High Performance Concrete Subjected to Fire (고성능 콘크리트의 화재시 폭렬성상에 관한 메카니즘 고찰)

  • Han, Min-Cheol;Kim, Seong-Hwan;Park, Yong-Kyu;Heo, Young-Sun;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.99-102
    • /
    • 2006
  • This paper reviews the relevant literatures and investigates spalling mechanism of high strength concrete, in order to clearly inform spalling problem in fire. Firstly, we studies literatures on spalling occurrence and resistance methods. Secondly chemical change of concrete components in elevated temperature was presented. Finally, mechanism of the spalling occurrence and spalling resistance were carried out with fiber content. In addition, our research team introduced spalling mechanism, being different from other points of view, which has been generally accepted. To secure this mechanism theory, we investigate spalling properties of certain specimens fabricated by roller spindle and made with mortar or concrete condition.

  • PDF

A study on the Spalling causes of Work roll for Cold rolling (냉간압연용 작업롤의 Spalling 발생원인에 관한 연구)

  • 김순경;전언찬;전태옥
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.220-226
    • /
    • 1995
  • A study on the spalling causes of work roll for cold rolling was performed in the cold rolling mill. Performance of work roll is dependent to a great extent on spalling sothat both roll manufactures and users show great interest in spalling. So this paper shows that spalling origin on the roll surface. As being well known, spalling mostlyoccurred due to developing fatigue fracture originated a crack on a roll. But such spalling can be prevented by proper roll maintenance, The spalling accidents have sharply decreased since 1981 because of the use of ultrasonic test to detect cracks on a roll.

  • PDF

Spalling Properties of High Performance Concrete Designed with the Various Types of Coarse Aggregate (굵은골재 종류 변화에 따른 고성능 콘크리트의 폭렬특성)

  • Heo, Young-Sun;Park, Yong-Kyu;Jin, Hu-Lin;Jee, Suk-Won;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.11a
    • /
    • pp.95-98
    • /
    • 2006
  • This study investigates spalling properties of high performance concrete, 60MPa clan, made with the various types of coarse aggregate and adding ratio of polypropylene(PP) fiber. As experimental parameters, totally sixteen specimens of ${\phi}100{\times}200mm$ in size are prepared: one specimen for control without fiber, ten specimens with different coarse aggregate types, along with 0.05, 0.1, 0.15 percent of PP fiber in each. 1 hour fire test is conducted and then spalling appearance, spalling degree and residual compressive strength are examined. In addition, sit specimens made with two types of coarse aggregate site, along with same adding ratio of fiber are supplementally done, and only spalling properties is examined. Test results showed that control concrete and most specimens containing 0.05% of PP fiber exhibited 4 to 3 level of spalling degree, resulting severe explosive spalling, except for the specimen using basalt aggregate(Bc) showing 2 to 3 level of that. Especially, the Bc specimen containing 0.1% of the fiber exhibited that residual compressive strength value was 32%, which is 10% higher than other specimens using limestone or granite. Spalling resistance performance was also effective as aggregate size increase.

  • PDF

Quantitative assessment of spalling depth and width using statistical inference theory in underground openings (통계추론을 이용한 지하암반공동에서의 스폴링 깊이와 폭에 대한 정량적 평가)

  • Bang, Joon-Ho;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.1
    • /
    • pp.1-14
    • /
    • 2010
  • Until now, the evaluation method of spalling depth using Martin et al. (1999)'s linear regression relations has long been known applicable. However, it is not likely that the proposed equation is applicable to the openings other than circular type and mostly overpredict the spalling depth in comparison with actual spalling cases. Moreover, the evaluation method to estimate the spalling width has not been presented yet; it is essential to evaluate the spalling width in addition to the spalling depth, because the shape of the spalled region influences the choice of suitable rock reinforcement. In this study, linear regression equations, in which normalized spalling depth ($d_f/W_D$) and normalized spalling width ($w_f/W_D$) are functions of three spalling evaluation indices, ${\sigma}_1/{\sigma}_c,\;D_{is}(={\sigma}_{max}/{\sigma}_c)$ and ${\sigma}_{dev}/{\sigma}_{cm}$, are established based on in-situ spalling observations and CWFS simulation results. Confidence intervals of 95% using the statistical inference theory are used in verifying the reliability of linear regression equations. Spalling depth ($d_f$) and spalling width ($w_f$) predicted from the proposed linear regression relations, which take three spalling evaluation indices into account, showed reasonable match with in-situ observations by adopting weighting factors considering the degree of variance of linear regression relations.

A Study on the Spalling Properties of High-Performance Concrete with the Kinds of Aggregate and Polypropylene Fiber Contents (골재종류 및 폴리프로필렌 섬유 혼입률 변화에 따른 고성능 콘크리트의 폭열 특성에 관한 연구)

  • 한천구;양성환;이병렬;황인성
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.5
    • /
    • pp.69-77
    • /
    • 1999
  • A spalling is defined as the damages of concrete exposed to high temperature during the fire by causing cracks and localized bursting of small pieces of concrete. It is reported that spalling is caused by the vapor pressure and polypropylene(PP) fiber has an important role in protecting from spalling. This paper is a study on the properties and spalling resistance of high-performance concrete with the kinds of aggregate and the contents of PP fiber. According to the experimental results, concrete contained no PP fiber take place in the form of the surface spalling and the failure of specimenns after fire test regardless of the kinds of aggregate. Concrete contained more than 0.05% of PP fiber with the aggregate of basalt does not take place the spalling, while the concrete using granite and limestone does the surface spalling. It is found that residual compressive strength after exposed at high temperature has 50~60% of its original strength. Although specimens after exposed at high temperature is cured at water for 28days, they do not recover their original strength.

Effect of Fire Induced Spalling on the Response of Reinforced Concrete Beams

  • Kodur, V.K.R.;Dwaikat, M.B.
    • International Journal of Concrete Structures and Materials
    • /
    • v.2 no.2
    • /
    • pp.71-81
    • /
    • 2008
  • A macroscopic finite element model is applied to investigate the effect of fire induced spalling on the response of reinforced concrete (RC) beams. Spalling is accounted for in the model through pore pressure calculations in concrete. The principles of mechanics and thermodynamics are applied to compute the temperature induced pore pressure in the concrete structures as a function of fire exposure time. The computed pore pressure is checked against the temperature dependent tensile strength of concrete to determine the extent of spalling. Using the model, case studies are conducted to investigate the influence of concrete permeability, fire scenario and axial restraint on the fire induced spalling and also on the response of RC beams. Results from the analysis indicate that the fire induced spalling, fire scenario, and axial restraint have significant influence on the fire response of RC beams. It is also shown that concrete permeability has substantial effect on the fire induced spalling and thus on the fire response of concrete beams. The fire resistance of high strength concrete beams can be lower that that of normal strength concrete beams due to fire induced spalling resulting from low permeability in high strength concrete.

An Experimental Study on the Explosive Spalling Properties of High Strength Concrete Structure Member (고강도 콘크리트 구조부재의 폭렬 특성에 관한 실험적 연구)

  • Kim, Heung-Youl;Jeon, Hyun-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.421-424
    • /
    • 2006
  • This study, in order for perceiving the mechanical attribute followed by the explosive spalling of high strength concrete material under high temperature and evaluating capacity of endurance of material, targets understanding capacity of endurance of material such as explosive spalling in high temperature, temperature by thickness of clothing, transformation extent, transformation speed and displacement, stocking the maximum load based on the Allowable Stress Design Method. As a result of experimenting the explosive spalling attribute of high strength concrete material, the one possibly causing serious damage is the 50 MPa concrete. In all aspects of 60 MPa concrete, explosive spalling happens. Especially, it is hazardous enough to reveal all the iron bar. All explosive spalling is intensively concentrated on the surface of concrete for the first $5{\sim}25$ minutes, which urges for the explosive spalling protection action. As a result of evaluating the structural safety by the transformation of high strength concrete, while beam assures the fire safety meeting regulation, 60 MPa shows the dramatic increase of transformation, which only counts 84% of safety. In a column, both the concrete exclusion and excessive explosive spalling are concentrated upper part of column, which brings about the dramatic transformation, so it only meets the 50% of safety regulation. Likewise, in 80, 100 MPa concrete which was never experimented considering the condition of domestic structural endurance stocking devices, the faster collapse is expected.

  • PDF

Spalling Properties of High-Performance Concrete with the Kinds of Admixture and Polypropylene Fiber Contents (혼화재 종류 및 폴리프로필렌 섬유의 혼입률 변화에 따른 고성능 콘크리트의 폭열 특성)

  • Han, Cheon-Goo;Yang, Seong-Hwan;Lee, Byung-Yul;Hwang, Yin-Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.4 no.1
    • /
    • pp.85-92
    • /
    • 2000
  • Recently. there has been steadily applied in high-performance concrete using powder type admixture in construction field. It has been reported that high-performance concrete is likely to cause the spalling by fire more seriously due to the dense microstructure. In this paper, spalling properties of high-performance concrete with the kinds of admixture and polypropylene(PP) fiber contents are presented. According to the experimental results concrete contained no PP fiber take place in the form of the surface spalling, regardless of admixture. Concrete contained more than 0.05% of PP fiber and admixture do not take place the spalling, however the concrete using silica fume do spalling. Concrete using blast furnace slag have good performance in spalling resistance. It is found that residual compressive strength has 60~70% of its original strength when spalling do not occur. Although specimens after exposed at high temperature are cured at water for 28days, they do not recover their original strength.

  • PDF

Assessment of spalling occurrence using fuzzy probability theory and damage index in underground openings (퍼지확률이론과 손상지수를 이용한 지하암반공동에서의 스폴링 발생 평가)

  • Bang, Joon-Ho;Lee, Kang-Hyun;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.1
    • /
    • pp.15-29
    • /
    • 2010
  • Spalling is a kind of instability phenomenon of surrounding rock around underground openings subjected to high in-situ stress according to the development of extension fractures. Three kinds of spalling criteria have been presented so far; however, all spalling criteria have the range of values so that the fuzziness and vagueness of spalling criterion cannot be avoided. In this study, a new fuzzy probability model is proposed to predict the probability of spalling in a systematic way by using fuzzy probability theory. Many of the underground opening projects worldwide are evaluated with the proposed method. Prediction results expressed as the spalling probability agree well with the in-situ observations. In particular, a new fuzzy probability model considering all three evaluation indices of spalling by adopting weighting factors based on relative reliability among three evaluation indices is able to resolve erroneous prediction of spalling by choosing only one prediction method. Moreover, the more reasonable value of spalling probability could have been obtained by adopting the modified damage index to the newly proposed fuzzy probability model.

Spalling of Concrete with Compressive strength and heating rates (압축강도 및 가열속도에 따른 콘크리트의 폭렬성상)

  • Choe, Gyeong-Choel;Kim, Gyu-Yong;Yoon, Min-Ho;Lee, Young-Wook;Hwang, Ui-Chul;Yoo, Jae-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.11a
    • /
    • pp.43-44
    • /
    • 2015
  • In this study, spalling property were evaluated from concrete with compressive strengths of 30MPa, 90MPa, 180MPa, applied with fast heating condition(ISO-834 standard heating curve) and slow heatign condition(1℃/min). As a result, the spalling property of concrete was shown differently with compressive and heatign rate. And It could be separated three as non spalling, surface spalling and explosive spalling.

  • PDF