• Title/Summary/Keyword: source-filter model

Search Result 118, Processing Time 0.02 seconds

Evaluation Method for Improvement Efficiency of Indoor Air Quality in Residence (주택의 실내공기질 개선 평가 방법)

  • Yang, Won-Ho;Son, Bu-Soon;Yim, Sung-Kuk
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.255-263
    • /
    • 2007
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time indoors. The purposes of this study were to evaluate the alternative method for improvement of indoor air quality in house after coating titanium dioxide ($TiO_2$) photocatalyst for interior part of the house using nitrogen dioxide ($NO_2$) multiple measurements. To evaluate the alternative method in indoor environment, daily indoor and outdoor $NO_2$ concentrations of an apartment and a detached house were daily measured for consecutive 21 days in winter and summer, respectively, Another daily 21 measurements were carried out after $TiO_2$ coating on wall paper of interior part in houses. All $NO_2$ concentrations were measured by passive filter badges. Indoor air quality models using mass balance are useful tool to quantify the relationship between indoor air pollution levels, ambient concentrations, and explanatory variables. Using a mass balance model and linear regression analysis, penetration factor (ventilation rate divided by sum of ventilation rate and decay rate) and source strength factor (emission rate divided by sum of ventilation rate and decay rate) were calculated. Subsequently, the decay constants were estimated. In this study. magnitude of improvement of indoor air quality could be evaluated by decay constant.

A Study for Characteristics of PM10 in the Subway Passenger Cabins (지하철 전동차 객실에서의 PM10 오염특성 파악에 관한 연구)

  • Oh, Mi-Seok;Park, Duck-Shin;Park, Eun-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.523-533
    • /
    • 2011
  • This study had the aim of characteristics of $PM_{10}$ in subway cabins. $PM_{10}$ was measured by times of day (rush and non rush hours) and seasons with real time $PM_{10}$ sampler on the subway cabins of line 7. Filter samples were collected for evaluation of their elemental composition as well as identification of major sources of $PM_{10}$ using a receptor model, PMF. $PM_{10}$ concentration were the highest in the winter season both in the rush and non rush hours at 152.8 ${\mu}g/m^3$, 90.2 ${\mu}g/m^3$ respectively. The $PM_{10}$ concentrations in rush hour were 30% higher compared to non rush hours. Based on the chemical information, the composition rare of inorganic elements was 52.5%, anions were 10.2% and others were 37.3%. Fe was the most abundant element and significantly correlated (p.0.01) with Mn (r=0.97), Ti (r=0.91), Cr (r=0.88), Ni (r=0.89) and Cu (r=0.88). Characterized $PM_{10}$ sources by PMF in the cabin were soil and road dust related sources (27.2%), railroad related sources (47.5%), secondary nitrate sources (16.2%) and a Cl-factor mixed with a secondary sulfate source (9.1%).

Analysis of CHAMP Magnetic Anomalies for Polar Geodynamic Variations

  • Kim Hyung Rae;von Frese Ralph R.B.;Park Chan-Hong;Kim Jeong Woo
    • Korean Journal of Remote Sensing
    • /
    • v.21 no.1
    • /
    • pp.91-98
    • /
    • 2005
  • On board satellite magnetometer measures all possible magnetic components, such as the core and crustal components from the inner Earth, and magnetospheric, ionospheric and' its coupled components from the outer Earth. Due to its dipole and non-dipole features, separation of the respective component from the measurements is most difficult unless the comprehensive knowledge of each field characteristics and the consequent modeling methods are solidly constructed. Especially, regional long wavelength magnetic signals of the crust are strongly masked by the main field and dynamic external field and hence difficult to isolate in the satellite measurements. In particular, the un-modeled effects of the strong auroral external fields and the complicated behavior of the core field near the geomagnetic poles conspire to greatly reduce the crustal magnetic signal-to-noise ratio in the polar region relative to the rest of the Earth. We can, however, use spectral correlation theory to filter the static lithospheric and core field components from the dynamic external field effects that are closely related to the geomagnetic storms affecting ionospheric current disturbances. To help isolate regional lithospheric anomalies from core field components, the correlations between CHAMP magnetic anomalies and the pseudo-magnetic effects inferred from satellite gravity-derived crustal thickness variations can also be exploited, Isolation of long wavelengths resulted from the respective source is the key to understand and improve the models of the external magnetic components as well as of the lower crustal structures. We expect to model the external field variations that might also be affected by a sudden upheaval like tsunami by using our algorithm after isolating any internal field components.

Development of OSL Dosimetry Reader (선량 판독용 OSL 측정장치의 개발)

  • Park, Chang-Young;Chung, Ki-Soo;Lee, Jong-Duk;Chang, In-Su;Lee, Jung-Il;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.10-15
    • /
    • 2012
  • Design and performance test results of a newly developed optically stimulated luminescence (OSL) measurement system are presented in this paper. Generally, different types of optical filters are used in OSL reader system to minimize the interference of the stimulation light in the OSL signal. For optically stimulation of $Al_2O_3:C$, we have arrived at an optimal combination of the filters, i.e., GG420 filter for filtering the stimulating light source, and a combined UG11 and BG39 filter at the detecting window (PMT). By using a high luminance blue LED (Luxeon V), sufficient luminous intensity could be obtained for optically stimulation. By using various control boards, the OSL reader device was successfully interfaced with a personal computer. A software was developed to deliver required commands to operate the OSL reader by using the LabView program (National Instruments, Inc.). In order to evaluate the reliability and the reproducibility of newly designed-OSL reader. Performance testing of the OSL reader was carried out for OSL efficiency, OSL decay curve and signal to noise ratio of the standard $Al_2O_3:C$ OSL material. It was found to be comparable with that of commercial Riso reader system.

A Study on the Emission and Dispersion of Particulate Matter from a Cement Plant (한 시멘트공장의 분진발생과 대기확산에 관한 조사연구)

  • Chang, Man-Ik;Chung, Yong;Kwon, Sook-Pyo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.16 no.1
    • /
    • pp.67-77
    • /
    • 1983
  • To investigate the an air pollution by particulate matter and its dispersion, a cement plant produceing portland cement 600,000 ton/year and its vicinity were surveyed from Obtober, 1980 to April, 1983. The survey was mainly focused on main stack emmission rate of the cement plant and particle size distribution in the dust, dustfall and total suspended particulate concentration in the area by month and distance from the stack. The results of the study were as follows; 1. The main stack emission rate was surveyed before and after the spray tower was additionally installed to the original E.P bag filter. Before the spray tower installed, the main stack emission rate was higher ($0.64g/Nm^3$) than the emission standard of Korean Environmental Preservation Law's ($0.59g/Nm^3$, amended to $0.4g/Nm^3$ on April 1983), but after the spray tower was installed, its main stack emission rate was markedly decreased to the standard ($0.43g/Nm^3$). 2. $2{\sim}3{\mu}m$ of the particle size was the largest portion (20.8%) of the dust particulate from the main stack and 50% of the frequency distribution was $1.5{\mu}m$ of the size. Most particle size was below $10{\mu}m$. 3. The spray tower reduced the dustfall to $37.81{\sim}9.76\;ton/km^2/month$ while dustfall appeared at $45.29-15.45ton/km^2/month$, in the vicinity of plant before spray tower installed 4. Mean concentrations of total suspended particulate for 24 hours of the various stations were determined in $20.6-200.0{\mu}g/m^3$, 3 stations of tham were higher than the value of Harry and William's arthmetic average standard $130{\mu}g/m^3$. 5. Linear regression between dustfall [X] and total suspended particulate[Y] concentration was an equation, Y=4.024X+11.479.[r=0.91] 6. During the whole seasons in the opposite area 100m apart from the omission source the prevailing wind direction was with estimated more than $30ton/km^2/month$, and the concentration of total suspended particulate for 24 hours averaging time was more than $140{\mu}g/m^3$ in the same area and direction. 7. Assuming the wind direction were constant through the day dustfalls for a day were estimated at $13.40ton/km^2/day,\;10.79ton/km^2/day$ and $4.55ton/km^2/day$ at various distances of 100m, 500m and 1,500m from the emission source respectively. 8. In the simutalion of dustfall and suspended dust by area, Gaussian dispersion model modified by size distribution of particulate matter was not applicated since the emission of dust were from multi sources other them stack. From the above results, it could be applied that the dispersion of dust from the cement plant is estimated and regulated for the purpose of environmental protection.

  • PDF

Simulation of sediment reduction effects of VFS in uplands of Saemangeum watershed (새만금유역 밭경지 초생대 유사저감효과 모의)

  • Lee, Seul Gi;Jang, Jeong Ryeol;Choi, Kyung Sook
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.6
    • /
    • pp.535-542
    • /
    • 2018
  • The study was intended to simulate the sediment reduction effects of the Vegetative Filter Strip (VFS) in uplands of Saemangeum watershed through VFSMOD-W model application. The model was calibrated by using the field data and the simulation scenarios were designed based on the investigation of uplands characteristics in Saemangeum watershed. The simulation scenarios were considered various size and slope of uplands including 1 ha, 5 ha, 10 ha of field size with width-length ratio of 1 : 1 having 7% and 15% of slopes under the daily rainfall of 50 mm, 100 mm, 150 mm, and 200 mm in order to mimic the different fields conditions. The effluent reduction ranged from 2.9~13.5% and 2.9~12.1% for runoff, and 33.8~97.0% and 27.1~85.9% for sediment under the field's slope of 7% and 15%, respectively. The VFS reduction effects showed different degree of influence from field size, slope, rainfall amounts. Based on the simulated results, the sediment contributing non-point source pollution expected to be reduced in the condition of VFS constructed 10% of fields in outlet of less than 10 ha of uplands having less than 15% of the slope.

Analysis of Suspended Solids Reduction by Vegetative Filter Strip for Cultivated Area Using Web GIS-Based VFSMOD (VFSMOD를 이용한 경작지의 고형물질 유출 저감효과)

  • Ahn, Jae Hwan;Yun, Sang Leen;Kim, Seog Ku;Park, Youn Shik;Lim, Kyoung Jae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.12
    • /
    • pp.792-800
    • /
    • 2012
  • The study was performed to simulate the reduction efficiency of suspended solids (SS) for cultivated land located at riverine area at the Namhan River and the Bukhan River watershed sites (site A, B, C) under the rainfall conditions using HUFF & SCS UH-based VFS Design module of Web GIS-based VFSMOD System. The study indicates that the field 5% sloped, located at Bukhan River watershed (site A), requires at least 0.5 m width of Vegetative Filter Strip (VFS) to reduce 70% of SS while the field 10% sloped requires the at least 1.0~1.5 m width of VFS to reduce 70% SS, under the condition 106.2 mm of rainfall event and bell pepper or corn of crops. Against the conditions 95.1 mm of rainfall event and sweet potato or soy bean of crops, the field 5% sloped, located at Namhan River watershed (site B) requires at least 0.5 m width of VFS to reduce 70% of SS while the field 10% sloped requires at least 1.0 m width of VFS to reduce 50% SS. The crops sweet potato and soy bean are cultivated in the site C, located at Namhan River watershed, 1 m of VFS is capable of 64.0% and 62.0% of SS reduction against 102.6 mm and 151.2 mm rainfall conditions respectively, for the 5% sloped field. The result supports that VFS is one of most potential methods to reduce SS from cultivated area, which is environment-friendly hydrologic structure. The VFS design, however, needs to be simulated before its installation in the field, the simulation needs to consider not only various characteristics of the field but also different conditions affecting the VFS, using a model capable to consider a lot of factors.

Determination of Attenuation Collection Methods According to the Type of Radioactive Waste Drums (방사성폐기물드럼 종류별 감쇠보정방법의 결정)

  • Kwak, Sang-Soo;Choi, Byung-I1;Yoon, Suk-Jung;Lee, Ik-Whan;Kang, Duck-Won;Sung, Ki-Bang
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.4
    • /
    • pp.309-317
    • /
    • 1997
  • The measured radioactivity of gamma-emitting radionuclides in each radioactive waste drum using the non-destructive waste assay method is underestimated than real radioactivity in radioactive waste drum because the gamma-rays are attenuated within the medium. Therefore, the measured radioactivity should be corrected for the attenuation of gamma-rays. For the correction of the attenuation of gamma-rays, the attenuation correction method should be applied differently by considering the distribution and density of medium in radioactive wastes drum generated from nuclear power plants. In this study, the model drums were fabricated for simulating five types of radioactive waste drums generated from nuclear power plant and the optimum methods of the attenuation correction were experimentally determined to analyze the activity of radionuclides in the waste drum accurately using the segmented gamma scanning system. With the determination of the attenuation correction methods from the experimental results the transmission method and the average density method for the miscellaneous waste drum, the transmission method and the differential peak absorption method for the shielded miscellaneous waste drum were used to measure the density of medium in waste drums. Also, the average density method and the differential peak absorption method for the spent resin drum, the paraffin solidified drum, and the spent filter drum were used.

  • PDF