• Title/Summary/Keyword: source to detector distance

Search Result 101, Processing Time 0.024 seconds

Study of the Radioactive Source Detection and the Visualization with the Stereo Radiation Detector (스테레오 기반 감마선원 탐지 및 가시화에 관한 연구)

  • Park, Gang-teak;Lee, Nam-ho;Cha, Han-ju
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1100-1102
    • /
    • 2015
  • In the study, stereo-based of gamma-ray sources detector for the space including the gamma-ray source to scan in a raster scan method, and obtains a visible light image and the gamma-ray image. We went to retrieve and visualize the distance to source and the direction of the 3-dimension information from Stereo gamma-ray detectors. Configuration of the detector consisted of gamma-ray detecting sensor for gamma-ray Sources, pan-tilt for the scanning of the raster for detecting sources, and CCD camera for visible-light image. Implement a stereo structure of the device to measure the spatial distribution of source, the gamma-ray Detector and CCD camera for the stereo image acquisition was as each configuration 2. The gamma-ray detector and a visible light camera to revision the distribution of detection source, After performing each of the cameras of the stereo correction and shows the distribution of the gamma-ray Sources through 중첩 visible light image and the gamma-ray image. After Rectification process of Left and right image, we were derived visualization results of the stereo image.

  • PDF

The Change of Asphalt Content by The Position of Neutron Source (중성자선원의 위치에 따른 아스팔트 함량의 변화)

  • Kim, Ki-Joon
    • 전자공학회논문지 IE
    • /
    • v.45 no.2
    • /
    • pp.6-12
    • /
    • 2008
  • In this study, because of the importance of asphalt content, the target is to develop a asphalt content detector that the influence of the jurisdiction and usage of radioisotopes are limited of 100[${\mu}Ci$] or less. For development of a asphalt content detector, it is divided into three parts that is affected the change of asphalt content due to the position of neutron source. First part is to decrease the distance between asphalt mixture and neutron source, second is to install the reflector, and last is to change the history number. It performed to analysis by computer simulation and satisfactory results of error range can use to design data for development of a asphalt content detector.

Improvement of Analytic Reconstruction Algorithms Using a Sinogram Interpolation Method for Sparse-angular Sampling with a Photon-counting Detector

  • Kim, Dohyeon;Jo, Byungdu;Park, Su-Jin;Kim, Hyemi;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.27 no.3
    • /
    • pp.105-110
    • /
    • 2016
  • Sparse angular sampling has been studied recently owing to its potential to decrease the radiation exposure from computed tomography (CT). In this study, we investigated the analytic reconstruction algorithm in sparse angular sampling using the sinogram interpolation method for improving image quality and computation speed. A prototype of the spectral CT system, which has a 64-pixel Cadmium Zinc Telluride (CZT)-based photon-counting detector, was used. The source-to-detector distance and the source-to-center of rotation distance were 1,200 and 1,015 mm, respectively. Two energy bins (23~33 keV and 34~44 keV) were set to obtain two reconstruction images. We used a PMMA phantom with height and radius of 50.0 mm and 17.5 mm, respectively. The phantom contained iodine, gadolinium, calcification, and lipid. The Feld-kamp-Davis-Kress (FDK) with the sinogram interpolation method and Maximum Likelihood Expectation Maximization (MLEM) algorithm were used to reconstruct the images. We evaluated the signal-to-noise ratio (SNR) of the materials. The SNRs of iodine, calcification, and liquid lipid were increased by 167.03%, 157.93%, and 41.77%, respectively, with the 23~33 keV energy bin using the sinogram interpolation method. The SNRs of iodine, calcification, and liquid state lipid were also increased by 107.01%, 13.58%, and 27.39%, respectively, with the 34~44 keV energy bin using the sinogram interpolation method. Although the FDK algorithm with the sinogram interpolation did not produce better results than the MLEM algorithm, it did result in comparable image quality to that of the MLEM algorithm. We believe that the sinogram interpolation method can be applied in various reconstruction studies using the analytic reconstruction algorithm. Therefore, the sinogram interpolation method can improve the image quality in sparse-angular sampling and be applied to CT applications.

A Basic Study for the Performance Evaluation of a Raman LiDAR Detector for Detecting Hydrogen Gas (수소 가스 검출용 라만 라이다 측정기의 성능 평가를 위한 기초 연구)

  • WONBO CHO;YUNKYU LIM;YANGKYUN KIM;BYOUNGJIK PARK
    • Journal of Hydrogen and New Energy
    • /
    • v.34 no.2
    • /
    • pp.205-211
    • /
    • 2023
  • Hydrogen gas is light and diffuses very quickly. Therefore, when a leakage accident occurs, the damage is great, so a technology that can quickly measure the leakage in the air at a long distance is needed. In order to develop hydrogen gas leaked in the atmosphere in a non-contact manner, an experiment was performed to measure hydrogen gas using a lidar technology using the Raman effect. Hydrogen Raman signals were detected using a UV LED light source, which is a Raman light source, and a spectrometer in the ultraviolet region including an optical filter in the 400-430 nm band. To develop this, a Raman lidar optical structure was designed to measure the hydrogen Raman signal at a certain distance, and the hydrogen Raman spectrum was confirmed using a standard gas to evaluate the performance of this optical structure. The linearity was found to be 0.99 using hydrogen standard gas (10, 50, 100, 500, 1,000 ppm). Accordingly, a Raman lidar capable of measuring hydrogen gas rapidly diffusing in the air in an open state was developed to improve the limitations of existing hydrogen sensors.

Transmission Dose Measurement of Gamma-ray Using Tungsten Shield (텅스텐 차폐체의 감마선 투과선량 측정)

  • Han, Sang-Hyun;Koo, Bon-Yeoul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.124-129
    • /
    • 2018
  • This study was conducted to investigate the penetration dose and shielding rates of tungsten shields used in apron material by changing the type of source used in the nuclear medicine department, thickness of shielding material and distance between the source and detector. For the experiment, the source, shield, and detector were arranged in a straight line and measured with an inspector at a height of 100 cm. The highest shielding effect of tungsten was measured for $^{201}Tl$, while $^{123}I$ showed a higher shielding effect than $^{99m}Tc$. For the sources used in the experiment, the penetration dose decreased with distance and the shielding rate was measured with thicker thickness. However, the shielding rate of $^{13}1I$ and $^{18}F$ sources was found to be lower than when there was no shielding at 0.25 mmPb shield. Therefore, even if the radiation shielding effect of tungsten is high, considering the characteristics according to the type of source and the thickness of the shielding material, it may be helpful to reduce the exposure.

Conceptual design of neutron measurement system for input accountancy in pyroprocessing

  • Lee, Chaehun;Seo, Hee;Menlove, Spencer H.;Menlove, Howard O.
    • Nuclear Engineering and Technology
    • /
    • v.52 no.5
    • /
    • pp.1022-1028
    • /
    • 2020
  • One of the possible options for spent-fuel management in Korea is pyroprocessing, which is a process for electrochemical recycling of spent nuclear fuel. Nuclear material accountancy is considered to be a safeguards measure of fundamental importance, for the purposes of which, the amount of nuclear material in the input and output materials should be measured as accurately as possible by means of chemical analysis and/or non-destructive assay. In the present study, a neutron measurement system based on the fast-neutron energy multiplication (FNEM) and passive neutron albedo reactivity (PNAR) techniques was designed for nuclear material accountancy of a spent-fuel assembly (i.e., the input accountancy of a pyroprocessing facility). Various parameters including inter-detector distance, source-to-detector distance, neutron-reflector material, the structure of a cadmium sleeve around the close detectors, and an air cavity in the moderator were investigated by MCNP6 Monte Carlo simulations in order to maximize its performance. Then, the detector responses with the optimized geometry were estimated for the fresh-fuel assemblies with different 235U enrichments and a spent-fuel assembly. It was found that the measurement technique investigated here has the potential to measure changes in neutron multiplication and, in turn, amount of fissile material.

Study on Development of Embedded Source Depth Assessment Method Using Gamma Spectrum Ratio (감마선 스펙트럼 비율을 이용한 매립 선원의 깊이 평가 방법론 개발 연구)

  • Kim, Jun-Ha;Cheong, Jea-Hak;Hong, Sang-Bum;Seo, Bum-Kyung;Lee, Byung Chae
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.1
    • /
    • pp.51-62
    • /
    • 2020
  • This study was conducted to develop a method for depth assessment of embedded sources using gamma-spectrum ratio and for the evaluation of field applicability. To this end, Peak to Compton and Peak to valley ratio changes were evaluated according to 137Cs, 60Co, 152Eu point source depth using HPGe detector and MCNP simulation. The effects of measurement distance of PTV and PTC methods were evaluated. Using the results, the source depth assessment equation using the PTC and PTV methods was derived based on the detection distance of 50 cm. In addition, the sensitivity of detection distance changes was assessed when using PTV and PTC methods, and error increased by 3 to 4 cm when detection distance decreased by 20 cm based on 50 cm. However, it was confirmed that if the detection distance was increased to 100 cm, the effects of detection distance were small. And PTV and PTC methods were compared with the two distance measurement method which evaluates the depth of source by the change of net peak counting rate according to the detection distance. As a result of source depth assessment, the PTV and PTC showed a maximum error of 1.87 cm and the two distance measurement method showed maximum error of 2.69 cm. The results of the experiment confirmed that the accuracy of the PTV and PTC methods was higher than two distance measurement. In addition, Sensitivity evaluation by horizontal position error of source has maximum error of less than 25.59 cm for the two distance measurement method. On the other hand, PTV and PTC method showed high accuracy with maximum error of less than 8.04 cm. In addition, the PTC method has lowest standard deviation for the same time measurement, which is expected to enable rapid measurement.

A Study on Efficiency Error in Distance Inverse Square Law using Cylinder NaI(Tl) Scintillation Detector (원통형 NaI(Tl) 신틸레이션 검출기를 이용한 거리의 역자승 법칙에서 효율 오류에 대한 연구)

  • Lee, Samyol;Yoon, Jungran;Ro, TaeIk
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.5
    • /
    • pp.333-338
    • /
    • 2013
  • Generally, it's known fact that intensity of radioactivity satisfies inverse-square law. However, the law was dissatisfied with practical experiment because of limited shape of scintillation detector. Especially, in the case of near distance between the surface of detector and the radioactive source, the difference grows larger. In the present study, reason of this difference was confirmed by experiment with $2^{{\prime}{\prime}}{\times}2^{{\prime}{\prime}}{\phi}$ NaI(Tl) scintillation detector and $^{60}Co$(1.174 MeV, 1.333 MeV)and $^{137}Cs$(0.662 MeV) gamma ray sources. From the experiment, the correction coefficient was obtained with gamma ray detection efficiency and geometrical volume. In the result of the present study, the efficiency difference of the detector was corrected with the coefficient. In the present result, we obtained that the inverse-square law experiment have to consider the efficiency and geometrical value of the detector.

Development and Usefulness Evaluation of Virtual Reality Simulator for Education of Spatial Dose Rate in Radiation Controlled Area (방사선관리구역의 공간선량률 교육을 위한 가상현실 시뮬레이터의 개발과 유용성 평가)

  • Jeong-Min Seo
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.493-499
    • /
    • 2023
  • This study developed education contents of measuring spatial dose with virtual reality simulation and applied to students majoring radiological science. The virtual reality(VR) contents with measuring spatial dose rate in the radiation controlled area was developed based on the simulation from pilot study. In this simulation, the tube voltage and tube current can be set from 60 to 120 kVp in 10 kVp steps and 10 to 40 mAs in 10 mAs increments, and the distance from source can be set from 30 to 400 cm continuously. Iron and lead shields can be placed between the source and the detector, and shielding thickness can be set by 1 mm increments ranging from 1 to 20 mm. We surveyed to students for evaluating improvement of understanding spatial dose rate between before and after education by VR simulation. The survey was conducted with 5 questions(X-ray exposure factors, effects by distance from the source, effects from using shield, depending on material and thickness of shield, concept and measuring of spatial dose rate) and all answers showed significant improvement. Therefore, this VR simulation content will be well used in education for spatial dose rate and radiation safety environments.

The Study for the Fast Detection of the Stereo Radiation Detector using the Image Processing (영상처리기반 스테레오 감마선 탐지장치의 고속탐지에 관한 연구)

  • Hwang, Young-gwan;Lee, Nam-ho
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.1103-1105
    • /
    • 2015
  • Leaked Radioactive source in nuclear power station, radiation related facilities and the aging nuclear power plant for the dismantling must need to detect and remove early to prevent major accidents. In this paper, we implemented a single sensor-based gamma-ray detectors stereo which can provide the distance to the radiation source, a direction and doserate information for fast and efficient decontamination work the radiation source. And we have carried out an algorithm development for high-speed detection of the detection equipment. Two detectors are required for stereo structure for obtaining the distance information of the radioactive source, but we designed the only sensor-based detection device for the weight reduction. We have extracted the region of interest and obtained the distance calculation result and distribution of radiation source in order to minimize a stereo image acquisition time. Detection time of the algorithm showed a shorter time of about 41%.

  • PDF