• 제목/요약/키워드: source reduction

검색결과 1,927건 처리시간 0.029초

청소기의 공력소음 특성 파악 및 저소음화에 관한 연구 (A Study on the Identification of Aeroacoustic Noise and Noise Reduction for a Vacuum Cleaner)

  • 전완호;백승조;김창준
    • 한국소음진동공학회논문집
    • /
    • 제13권6호
    • /
    • pp.460-466
    • /
    • 2003
  • The aeroacoustic characteristics and noise reduction method of a centrifugal fan for a bagless vacuum cleaner were studied. The major noise source of vacuum cleaner is the centrifugal fan. The impeller of the fan rotates over 30000 rpm and generates very high-level piercing noise. It was found that the dominant noise source of the fan is generated from the aerodynamic interaction between the highly rotating impeller and stationary diffuser. In order to reduce the high tonal sound generated from the aerodynamic interaction between the impeller and diffuser, tapered impeller was carefully designed and tested. The trailing edge of the tapered impeller was inclined and this reduces the flow interactions between the rotating impeller and the stationary diffuser because of some phase shift. The static efficiency of the new impeller is slightly lower than the conventional one. The overall SPL is reduced about 3.6 dBA. The SPL of blade passing frequency(BPF) is reduced about 6 dBA and the $2^{nd}$ BPF is reduced about 20 dBA. The vacuum cleaner with the tapered impeller has lower noise level than that of the previous impeller and the strong tonal sound was dramatically reduced.

주차장 비점오염원 관리를 위한 식생체류지 개발 및 평가 (Development and Evaluation of Bioretention Treating Stormwater Runoff from a Parking Lot)

  • 유기경;최지연;홍정선;문소연;김이형
    • 한국습지학회지
    • /
    • 제17권3호
    • /
    • pp.221-227
    • /
    • 2015
  • 도시화에 따른 개발사업은 불투수층을 증가시키며, 강우시 비점오염물질의 유출량을 증가시킨다. 이러한 도시화에 의한 비점오염물질의 유출량을 저감하기 위하여 국내 외에서는 저영향개발(Low Impact Development, LID) 기법을 도입하고 있다. 따라서 본 연구에서는 LID 기법을 이용하여 도시지역 비점오염원 관리를 위한 식생체류지를 개발하고자 수행되었으며, 식생체류지의 효율 평가를 위하여 test-bed를 구축하여 2013년 11월부터 현재까지 총 11회 모니터링을 실시하였다. 유역면적 대비 식생체류지의 시설면적(SA/CA)이 약 2.2% 임에도 불구하고, 식생체류지 적용 이후 강우시 저류 및 침투량의 증가로 인하여 유출량이 크게 감소한 것으로 나타났다. 강우량 기준으로 유출량 저감을 살펴보면 0 mm < R <10 mm의 강우량 범위에서는 전량 침투 및 저류 되었으며, 10 mm < R <20 mm의 강우량 발생시 90% 이상 저류 되는 것으로 나타났다. 20 mm 이상의 강우량 발생시에는 70% 이상 저류 되는 것으로 분석되었다. 이러한 높은 유출저감은 비점오염물질의 저감효율을 향상시켰으며, 입자상 물질, 유기물 및 중금속 등을 약 90% 이상 저감시키는 것으로 나타났다.

Emergy를 이용한 오염물질 저감시설의 환경 비용/편익 분석 (Environmental Cost and Benefit Analysis Pollutant Reduction Facilities of the using the Emergy)

  • 김진이;황하선;김상수;이재관
    • 한국물환경학회지
    • /
    • 제29권5호
    • /
    • pp.591-597
    • /
    • 2013
  • The input emergy of an advanced treatment plant for reducing the 1 kg of TN and TP was estimated 4.14E+14 sej/kg, 5.02E+15 sej/kg, respectively. In addition, the input emergy of constructed wetland for reduction of the 1 kg of TN and TP reduction was estimated to be 2.48E+14 sej/kg, 3.38E+15 sej/kg, respectively. The cost reducing 1 kg of TN and TP for an advanced treatment plant was estimated 197,466 won and 2,388,739 won respectively and constructed wetland was estimated 117,976 won and 1,609,213 won respectively. As a result, All of the emergy source of constructed wetland for reducing non-point source is renewable resource. If we use the constructed wetland, it results in enhancing economic value by reducing of non-point pollution, controlling a flood and providing the habitat of animals or plants. Improving water quality program in the Nakdong River Basin should be changed into an ecological treatment facilities from expansion of the sewage treatment facilities and advanced treatment plant using high cost and non-renewable energies.

고랭지밭 밀집지역 초생대의 비점오염 저감 효율 평가 - 비점오염원 관리지역을 중심으로 (만대지구, 가아지구, 자운지구) - (Efficiency Evaluation of Vegetative Filter Strip for Non-point Source Pollutant at Dense Upland Areas - Focused on Non-point Source Management Area Mandae, Gaa, and Jaun Basins -)

  • 정연지;이동준;강현우;장원석;홍지영;임경재
    • 한국농공학회논문집
    • /
    • 제64권4호
    • /
    • pp.1-10
    • /
    • 2022
  • A vegetative filter strip (VFS) is one of the best management practices (BMPs) to reduce pollutant loads. This study aims to assess the effectiveness of VFS in dense upland field areas. The study areas are agricultural fields in the Maedae (MD), Gaa (GA), and Jaun (JU) watersheds, where severe sediment yields have occurred and the Korean government has designated them as non-point management regions. The agricultural fields were divided into three or four clusters for each watershed based on their slope, slope length, and area (e.g., MD1, MD2). To assess the sediment trapping (STE) and pesticide reduction efficiency (PRE) of VFS, the Vegetative Filter Strip Modeling System (VFSMOD) was applied with three different scenarios (SC) (SC1: VFS with rye vegetation; SC2: VFS with rye vegetation and a gentle slope in VFS range; and SC3: VFS with grass mixture). For SC1, there were relatively short slope lengths and small areas in the MD1 and GA3 clusters, and they showed higher pollutant reduction (STE>50%, PRE>25%). For SC2 and SC3, all clusters in GA and some clusters (MD1 and MD3) in MD show higher pollutant reduction (>25%), while the uplands in JU still show a lower pollutant (<25%). With correlation analysis between geographic characteristics and VFS effectiveness slope and slope length showed relative higher correlations with the pollutant efficiency than a area. The results of this study implied that slope and slope length should be considered to find suitable upland conditions for VFS installations.

다공성 경량골재 및 순환골재를 이용한 비점오염원 저감시설의 처리효율 평가 (Evaluation of the Non-point Source Treatment Facility using the porous lightweight aggregate and the recycled aggregate)

  • 강영현;장대창;강선홍
    • 상하수도학회지
    • /
    • 제23권6호
    • /
    • pp.735-741
    • /
    • 2009
  • This study intends to evaluate the efficiency of non-point source reduction technique by using the porous lightweight and recycled aggregate which microorganism is seeded. In case of infiltration velocity 30~70 mm/hr in high concentration of influent, it is indicated that SS was 40~94%, COD 44~91%, BOD 4~91%, TN 1.2~66%, TP 7~70% of removal efficiency. Removal efficiency is good in infiltration velocity 30 > 50 > 70㎜/hr order. Therefore, the non-point source treatment facility filled with lightweight and recycled aggregate using microbial seeding shows higher removal efficiency than a conventional sand and gravel. We confirm that the function and efficiency are improved significantly and applied to treat non-point sources.

Fast Time Difference of Arrival Estimation for Sound Source Localization using Partial Cross Correlation

  • Yiwere, Mariam;Rhee, Eun Joo
    • Journal of Information Technology Applications and Management
    • /
    • 제22권3호
    • /
    • pp.105-114
    • /
    • 2015
  • This paper presents a fast Time Difference of Arrival (TDOA) estimation for sound source localization. TDOA is the time difference between the arrival times of a signal at two sensors. We propose a partial cross correlation method to increase the speed of TDOA estimation for sound source localization. We do this by predicting which part of the cross correlation function contains the required TDOA value with the help of the signal energies, and then we compute the cross correlation function in that direction only. Experiments show approximately 50% reduction in the cross correlation computation time thereby increasing the speed of TDOA computation. This makes it very relevant for real world surveillance.

HERSCHEL OBSERVATIONS IN THE AKARI NEP FIELD: INITIAL SOURCE COUNTS

  • Pearson, Chris;Cheale, Ryan;Serjeant, Stephen;Matsuhara, Hideo;White, Glenn J.;Burgarella, Denis;Valtchanov, Ivan;Altieri, Bruno;Clements, David L.;Hopwood, Ros
    • 천문학논총
    • /
    • 제32권1호
    • /
    • pp.219-223
    • /
    • 2017
  • The preliminary data reduction, analysis and first results from the Herschel survey of the AKARI NEP field are presented. Herschel SPIRE observations of the NEP-Wide region and PACS observations of the NEP-Deep region have yielded galaxy catalogues of 4000 and 900 sources respectively down to flux density levels of approximately 15 mJy at 100-250 microns. Source counts produced from these catalogues reach cosmologically significant depths tracing the evolutionary upturn and turnover in the source counts. The source counts are in agreement with other large area surveys carried out with Herschel bridging the gap between the shallow and deep Herschel surveys.

소규모 공간에서의 잔향시간 영향요인 분석 (Analysis of the Factors affecting Reverberation Time in Small Room)

  • 김명준;이병기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.492-497
    • /
    • 2006
  • This study gives the results of the measurements and analysises of the reverberation times in a small room such as apartment houses. We measured the RT by changing measurement conditions, which were sound sources. sound source's positions, receiving point & height, sampling time and so on. The critical factor affecting reverberation time was sound source in unoccupied houses and the reverberation time differences between result of RT using impulsive and interrupted sound source was 0.3sec at 500Hz frequency. And the difference of RT due to sound sources affected the sound insulation such as apparent sound reduction index and sound level difference about 1dB at each frequency in unoccupied houses.

  • PDF

트랙터 운전실의 소음 저감에 관한 연구 (Noise Reduction in Tractor Cabin)

  • 김원진;은명우
    • 한국생산제조학회지
    • /
    • 제23권4호
    • /
    • pp.380-384
    • /
    • 2014
  • This study focused on identifying the major noise source in a tractor cabin using experimental methods. The noise levels in a tractor cabin for different engine revolution speeds were analyzed to identify the noise source. The results showed that the power steering unit (PSU) was the major noise source in a tractor cabin. The PSU was moved to the outside from the inside of the cabin in order to reduce the noise in the tractor cabin. As a result, the noise levels on the left and right sides of the operator in the tractor cabin were reduced by 6.8 and 3.9 dB, respectively. Finally, the window method was introduced to evaluate the contribution of the transmission noise. The orders of significance in the tractor noise were the front, bottom, and left area, successively.