• 제목/요약/키워드: source reduction

검색결과 1,927건 처리시간 0.03초

A Study on the Identification of Noise Source and the Noise Reduction Method of a Turbo Chiller (터보냉동기의 소음원 파악 및 저소음화에 대한 연구)

  • Jeon, Wan-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • 제7권3호
    • /
    • pp.7-13
    • /
    • 2004
  • In this paper, we identify the noise source and the path of a chiller. This chiller is newly developed for R-l34a refrigerant and 250 RT cooling capacity. The measured overall SPL of the developed turbo-chiller is about 100 dBA. Due to the high rotating speed of the centrifugal impeller, the nun noise source of the chiller is the blade passing frequency and its higher harmonics of the centrifugal impeller. This generated soundpropagates through the duct, and then transmits and radiates to the outer field. From the experiment, it is found that the high frequency noise is mostlytransmitted and radiated through the elbow duct, but the low frequency noise is transmitted and vadiated through the condenser wall. Therefore applying the absorbing material is an effective way of reducing the high and low frequency noise simultaneously. Measurement results show that the application of the sound absorbing material to the elbow duct reduced the overall sound pressure level by 4 dB compared to the 9 dBA reduction for the case of full enclosure. In order to control the generated noise, a dissipativetype silencer is also designed and tested. The silencer reduced the radiated noise about 7.5 dBA.

The Study of the Multi-Channel Active Noise Reduction of the Vehicle Cabin I : Computer Simulation (자동차 실내 소음저감을 위한 다채널 능동 소음제어에 관한 연구I : 컴퓨터 시뮬레이션)

  • Lee, T. Y.;Shin, J.;Kim, H. S.;Oh, J. E.
    • Journal of the korean Society of Automotive Engineers
    • /
    • 제14권5호
    • /
    • pp.95-106
    • /
    • 1992
  • Active control of acoustic noise is an application area of adaptive digital signal processing with increasingly interest along the last year. This work studies the implementation of the multichannel LMS filter and the application of this algorithm for the reduction of the noise inside a vechicle cabin using a number of 'secondary sources' drived by adaptive filtering of a reference noise source. Firstly, we propose the use of an adaptive method for the time-varient optimal convergence factor. Secondly, we propose the use of adaptive delayed inverse model to estimate the elastic-acoustic transfer function presented in vechicle cabin. The original, primary source is often periodic, with a known fundamental frequency. A suitably filtered reference signal can thus be used to drive the secondary sources. An algorithm is presented for adapting the coefficients of an FIR filter feeding such a secondary source in such a way as to minimize the output of a suitably placed microphone. In this algorithm, the coefficients of adaptive filter driving an array of secondary sources can be adapted to minimize the sum of the squares of the outputs of a number of error microphones. The multichannel LMS algorithm displays that such an algorithm is considered suitable to used for the global suppression of noise in vehicle cabin.

  • PDF

Hourly SWAT Watershed Modeling for Analyzing Reduction Effect of Nonpoint Source Pollution Discharge Loads (비점원오염 저감효과 분석을 위한 시단위 SWAT 유역 모델링)

  • Jang, Sun Sook;Ahn, So Ra;Choi, Joong Dae;Kim, Seong Joon
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • 제57권1호
    • /
    • pp.89-97
    • /
    • 2015
  • This study is to assess the effect of non-point source pollution discharge loads between tillage and no-tillage applications for upland crop areas using SWAT (Soil and Water Assessment Tool) watershed modeling. For Byulmi-cheon small rural catchment ($1.17km^2$) located in upstream of Gyeongan-cheon watershed, the rainfall, discharge and stream water quality have been monitored in the catchment outlet since 2011. The SWAT model was calibrated and validated in hourly basis using 19 rainfall events during 2011-2013. The average Nash-Sutcliffe model efficiency and $R^2$ (determination coefficient) for streamflow were 0.67 and 0.79 respectively. Using the 10 % surface runoff reduction from experiment results for no-tillage condition in field plots of 3 % and 8 % slopes under sesami cultivation, the soil saturated hydraulic conductivity for upland crop areas was adjusted from 0.001 mm/hr to 0.0025 mm/hr in average. Under the condition, the catchment sediment, T-N (total nitrogen, TN), and T-P (total phosphorus, TP) discharge loads were reduced by 6.9 %, 7.4 %, and 7.7 % respectively.

A Study on the Vibration Reduction by the Position of Borehole using Experimental Waveform and Finite Element Analysis (실측파형과 유한요소해석을 통한 방진구의 위치별 진동 저감 연구)

  • Song, Jeong-Un;Kim, Seung-Kon;Park, Hoon;Hong, Woong-Ki
    • Journal of Environmental Impact Assessment
    • /
    • 제22권4호
    • /
    • pp.381-387
    • /
    • 2013
  • In order to improve the environmental vibration, it is necessary to method for not only reduce the vibration source, but also control the vibration path. In this study, we used borebole for estimate the vibration reduction. And also, we analyzed displacement and vibration velocity caused by the position of borehole as well as the condition of borehole in ground structure. Visual FEA(Finite Element Analysis) program was used in this numerical analysis. The results are as follows : The displacement magnitude and X, Y direction displacement were represented to different results due to the condition and position of borehole, and were represented to the lowest values when the position of borehole is the most close condition from the vibration source. And also, the vibration velocity was decreased as using borebole in ground structure. The isolation efficiency of the vibration was calculated to maximum 18.40% when borehole was established to the most close position from the vibration source and the receive point.

FEASIBILITY STUDY OF SOUND POWER BASED ACTIVE NOISE CONTROL STRATEGIES FOR GLOBAL NOISE REDUCTION

  • Kang, Seong-Woo;Kim, Yang-Hann
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.785-790
    • /
    • 1994
  • The active noise control which regards the acoustic power as a target function to be minimized, is analyzed to test its feasibility of which simplifies the measurement system compared with the global acoustic energy based active noise control system. In fact, it is found that the acoustic power based active noise control strategy is equally likely as good as the global acoustic energy based active noise control method if the acoustic field of interest is diffusive or very low model density one. In the intermediate model density field, we also demonstrate that the power based control gives the similar results as the energy based control in terms of global sound energy reduction for the lightly damped enclosure which might be most important system in practical application. From all the theoretical and power based control strategy is dependent on the characteristics of the acoustic field to be controlled; i.e., the model density distribution, the degree of reverberation, and on the strength of modal interaction of the control source with the primary source; i.e., the location of control source.

  • PDF

Analysis of the Effects on Soil Erosion and Suspended Sediment Reduction by Alpine Unauthorized and Illegal Agricultural Fields Restoration Scenarios (고랭지 임의·불법 경작지 복구 시나리오에 따른 토양유실 및 부유사량 저감 효과 분석)

  • Lee, Seoro;Lee, Gwanjae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • 제66권2호
    • /
    • pp.53-62
    • /
    • 2024
  • This study assessed the efficiency of reducing soil erosion and suspended sediment through the restoration of alpine unauthorized and illegally cultivated fields, using the SWAT (Soil and Water Assessment Tool) model in the Mandae District. The results showed that in Scenario 5, which involved restoring unauthorized and illegal fields within forests, along rivers (banks), and in ditch areas were restored to their original land categories, achieved the highest efficiency in reducing average annual soil erosion and suspended sediment, with reductions of 8.1% and 4.5%, respectively. In particular, it was confirmed that the restoration of unauthorized and illegal fields within forested areas has a significant impact. This demonstrated that the restoration of unauthorized and illegal agricultural fields can substantially reduce the soil erosion and suspended sediment attributable to non-point source pollution. Our findings highlight the importance of managing these unauthorized and illegal agricultural activities in developing sustainable strategies within non-point source pollution management areas. This study is expected to provide important basic data to effectively establish water quality improvement strategies in the region of non-point source pollution management.

A Study on the Reduction of Diesel-Engine Emissions (디젤엔진 배기가스의 저감에 관한 연구)

  • Hur, Youn-Bok;Chung, Soon-Suk;Kim, Kwang-Soo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 대한안전경영과학회 2012년 추계학술대회
    • /
    • pp.245-252
    • /
    • 2012
  • Internal engine is the main power source of vehicle and is the main source of air pollution. To satisfy this getting rigorous emission regulation, it must be solved simultaneously the dilemma of reducing emission gas and increasing heat efficiency. Diesel engine is preferred compare with gasoline engine in aspect of energy consumption but it must be solved reducing the containing of NOx, CO and HC. In this study 1. Looking for alternative of performance improvement of Exhaust Gas Recirculation(EGR) which is emission gas reduction system, 2. Reducing malfunction of controlling emission gas 3. Made possible precision control.

  • PDF

Identification and Reduction Method for Refrigerator Contraction and Expansion Noise (냉장고 수축팽창 소음원의 규명과 저감 방법)

  • Kim, Wonjin;Park, Seong Kyu
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • 제22권4호
    • /
    • pp.723-729
    • /
    • 2013
  • The contraction and expansion noise of a refrigerator are investigated, and some effective methods are proposed to reduce the level and occurrence frequency of noise. First, the noise of a refrigerator is measured to estimate the frequency spectrum and occurrence frequency of noise. Second, a sound visualization was conducted using an acoustic camera to determine the location of the noise source. From the results, it was observed that the internal part mainly producing noise was the third shelf in the freezer room. A method to estimate the acceleration on the location of the noise source is introduced to analyze the contraction and expansion noise precisely and accommodate experimental convenience. Noise reduction methods such as the replacement of the existing shelf with glass shelves, adoption of rail slides, and increase of roughness on the contact surface of the shelf are proposed and tested.

Evaluation of Floor Impact Sound by Floor Coverings in Standard Test Building (표준시험동에서 바닥마감재에 따른 바닥충격음 특성평가)

  • Kim, Hak-Cheon;Kim, Yong-Gil;Kim, Sang-Chul;Lee, Hyun-Lyul;Cho, Hyung-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 한국소음진동공학회 2008년도 추계학술대회논문집
    • /
    • pp.439-440
    • /
    • 2008
  • Five floor coverings were tested with three different types of floor structures in the standard test building in order to evaluate the effectiveness of the floor impact sound reduction. The level of floor impact sound reduction is influenced by not only the types of floor coverings but interrelationship between the floor coverings and floor structures. From the tests, it was found that floor coverings were effective in reducing the floor impact sound using the light impact source. In addition, proper mixtures of the floor structure and the floor covering have shown effectiveness to a certain extent in reducing the floor impact sound using the heavy impact source.

  • PDF

Detonating Cord as a Controllable Source for Scaled Model Blasting Test (축소모형실험 폭원으로서 도폭선의 폭력조절)

  • Yang, Hyung-Sik;Kim, Jong-Gwan;Choi, Mi-Jin;Choi, Byung-Hee;Ryu, Chang-Ha
    • Tunnel and Underground Space
    • /
    • 제17권4호
    • /
    • pp.295-300
    • /
    • 2007
  • A method using detonating cord was suggested to control the blasting source for scaled model test. Blasting of 5 concrete block was carried out to verify the method. It was proved that blasting power can be controlled by suggested method. It seemed to be reasonable to use the reduction ratio based on the explosion heat.