• Title/Summary/Keyword: source current density

Search Result 309, Processing Time 0.025 seconds

940-nm 350-mW Transverse Single-mode Laser Diode with AlGaAs/InGaAs GRIN-SCH and Asymmetric Structure

  • Kwak, Jeonggeun;Park, Jongkeun;Park, Jeonghyun;Baek, Kijong;Choi, Ansik;Kim, Taekyung
    • Current Optics and Photonics
    • /
    • v.3 no.6
    • /
    • pp.583-589
    • /
    • 2019
  • We report experimental results on 940-nm 350-mW AlGaAs/InGaAs transverse single-mode laser diodes (LDs) adopting graded-index separate confinement heterostructures (GRIN-SCH) and p,n-clad asymmetric structures, with improved temperature and small-divergence beam characteristics under high-output-power operation, for a three-dimensional (3D) motion-recognition sensor. The GRIN-SCH design provides good carrier confinement and prevents current leakage by adding a grading layer between cladding and waveguide layers. The asymmetric design, which differs in refractive-index distribution of p-n cladding layers, reduces the divergence angle at high-power operation and widens the transverse mode distribution to decrease the power density around emission facets. At an optical power of 350 mW under continuous-wave (CW) operation, Gaussian narrow far-field patterns (FFP) are measured with the full width at half maximum vertical divergence angle to be 18 degrees. A threshold current (Ith) of 65 mA, slope efficiency (SE) of 0.98 mW/mA, and operating current (Iop) of 400 mA are obtained at room temperature. Also, we could achieve catastrophic optical damage (COD) of 850 mW and long-term reliability of 60℃ with a TO-56 package.

A Study on the Effect of Carbon Nanotube Directional Shrinking Transfer Method for the Performance of CNTFET-based Circuit (탄소나노튜브 방향성 수축 전송 방법이 CNTFET 기반 회로 성능에 미치는 영향에 관한 연구)

  • Cho, Geunho
    • The Journal of the Convergence on Culture Technology
    • /
    • v.4 no.3
    • /
    • pp.287-291
    • /
    • 2018
  • The CNTFET, which is attracting attention as a next-generation semiconductor device, can obtain ballistic or near-ballistic transport at a lower voltage than that of conventional MOSFETs by depositing CNTs between the source and drain of the device. In order to increase the performance of the CNTFET, a large number of CNTs must be deposited at a high density in the CNTFET. Thus, various manufacturing processes to increase the density of the CNTs have been developed. Recently, the Directional Shrinking Transfer Method was developed and showed that the current density of the CNTFET device could be increased up to 150 uA/um. So, this method enhances the possibility of implementing a CNTFET-based integrated circuit. In this paper, we will discuss how to evaluate the performance of the CNTFET device compared to a MOSFET at the circuit level when the CNTFET is fabricated by the Directional Shrinkage Transfer Method.

Lipid-lowering and hepatoprotective effects of Vitis vinifera dried seeds on paracetamol-induced hepatotoxicity in rats

  • Almajwal, Ali Madi;Elsadek, Mohamed Farouk
    • Nutrition Research and Practice
    • /
    • v.9 no.1
    • /
    • pp.37-42
    • /
    • 2015
  • BACKGROUND/OBJECTIVES: Red grape seeds as functional food are a good source of important bioactive components such as phenolics and antioxidants, which decrease oxidative stress that contributes to the pathogenesis of hepatotoxicity. The current study was conducted in order to evaluate the protective effect of red grape dried seeds (RGDS) on antioxidant properties, lipid metabolism, and liver and kidney functions of rats with paracetamol (750 mg/kg) induced hepatotoxicity. MATERIALS/METHODS: RGDS was added to the basal diet at 5, 10, and 20%. Thirty five adult male rats were assigned to five groups (n = 7) for a six-week feeding period; group (1) normal control, group (2) induced control, groups (3, 4, and 5) fed a diet with RGPS at different levels, 5, 10, and 20%, respectively. At the end of the feeding period, animals' blood and tissues were collected for estimation of serum lipid profile, serum liver, and kidney biomarkers. The protection was measured by detecting lipid peroxidation (LPO), glutathione (GSH), superoxide dismutase (SOD), Catalase (CAT) (in liver tissues), and liver histological examination. RESULTS: The results showed a significant (P < 0.05) decrease in levels of serum cholesterol, triglycerides, low density lipoprotein (LDL-C), and very low density lipoprotein (VLDL-C), with a significant increase in level of high density lipoprotein (HDL-C) for RGDS groups compared to induced control. Rats administered a diet containing RGDS levels produced significant (P < 0.05) hepatoprotection by decreasing the activities of liver enzymes, kidney parameters, and lipid peroxidation, while levels of GSH, SOD, and CAT were increased significantly to near the normal levels. CONCLUSION: The RGDS 20% group was more effective than others against hepatotoxicity of paracetamol, which may be attributed to RGDS total phenols and antioxidant contents, which were 1.438 mg and 1.231 mg, respectively.

Manganese Doped LiFePO4 as a Cathode for High Energy Density Lithium Batteries (고에너지밀도 리튬전지를 위한 망간이 첨가된 LiFePO4 양극재료)

  • Kim, Dul-Sun;Kim, Jae-Kwang;Ahn, Jou-Hyeon
    • Journal of the Korean Electrochemical Society
    • /
    • v.16 no.3
    • /
    • pp.157-161
    • /
    • 2013
  • Porous $LiMn_{0.6}Fe_{0.4}PO_4$ (LMFP) was synthesized by a sol-gel process. Uniform dispersion of the conductive carbon source throughout LMFP with uniform carbon coating was achieved by heating a stoichiometric mixture of raw materials at $600^{\circ}C$ for 10 h. The crystal structure of LMFP was investigated by Rietveld refinement. The surface structure and pore properties were investigated by SEM, TEM and BET. The LMFP so obtained has a high specific surface area with a uniform, porous, and web-like nano-sized carbon layer at the surface. The initial discharge capacity and energy density were 152 mAh/g and 570 Wh/kg, respectively, at 0.1 C current density, and showed stable cycle performance. The combined effect of high porosity and uniform carbon coating leads to fast lithium ion diffusion and enhanced electrochemical performance.

Multi-channel Transimpedance Amplifier Arrays in Short-Range LADAR Systems for Unmanned Vehicles (무인차량용 단거리 라이다 시스템을 위한 멀티채널 트랜스임피던스 증폭기 어레이)

  • Jang, Young Min;Kim, Seung Hoon;Cho, Sang Bock;Park, Sung Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.40-48
    • /
    • 2013
  • This paper presents multi-channel transimpedance amplifier(TIA) arrays in short-range LADAR systems for unmanned vehicles, by using a 0.18um CMOS technology. Two $4{\times}4$ channel TIA arrays including a voltage-mode INV-TIA and a current-mode CG-TIA are introduced. First, the INV-TIA consists of a inverter stage with a feedback resistor and a CML output buffer with virtual ground so as to achieve low noise, low power, easy current control for gain and impedance. Second, the CG-TIA utilizes a bias from on-chip bandgap reference and exploits a source-follower for high-frequency peaking, yielding 1.26 times smaller chip area per channel than INV-TIA. Post-layout simulations demonstrate that the INV-TIA achieves 57.5-dB${\Omega}$ transimpedance gain, 340-MHz bandwidth, 3.7-pA/sqrt(Hz) average noise current spectral density, and 2.84mW power dissipation, whereas the CG-TIA obtains 54.5-dB${\Omega}$ transimpedance gain, 360-MHz bandwidth, 9.17-pA/sqrt(Hz) average noise current spectral density, and 4.24mW power dissipation. Yet, the pulse simulations reveal that the CG-TIA array shows better output pulses in the range of 200-500-Mb/s operations.

Spatiotemporal Analysis of Hippocampal Long Term Potentiation Using Independent Component Analysis

  • Kim, T.S.;Lee, J.J.;Hwang, S.J.;Lee, Y.K.;Park, J.H.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.17-23
    • /
    • 2007
  • Long-term potentiation (LTP) of synaptic transmission is the most widely studied model for learning and memory. However its mechanisms are not clearly elucidated and are a subject for intense investigation. Previous attempts to decipher cellular mechanisms and network properties involved a current-source density analysis (CSDA) of the LTP from small animal hippocampus measured with a limited number of microelectrodes (typically <3), only revealing limited nature of spatiotemporal dynamics. Recent advancement in multi-electrode array (MEA) technology allows continuous and simultaneous recordings of LTP with more than 60 electrodes. However CSDA via the standard Laplacian transform is still limited due to its relatively high sensitivity toward noise, inability of resolving overlapped current sources and sinks, and its requirement for tissue conductivity values. In this study, we propose a new methodology for improved CSDA. Independent component analysis and its joint use (i.e., Joint-ICA) are applied to extract spatiotemporal components of LTP. The results show that ICA and Joint-ICA are capable of extracting independent spatiotemporal components of LTP generators. The ICs of LTP indicate the reversing roles of current sources and sinks which are associated with LTP.

Detection of Rapid Atrial Arrhythmias in SQUID Magnetocardiography (스퀴드 심자도 장치를 이용한 심방성 부정맥의 측정)

  • Kim Kiwoong;Kwon Hyukchan;Kim Ki-Dam;Lee Yong-Ho;Kim Jin-Mok;Kim In-Seon;Lim Hyun-Kyoon;Park Yong-Ki;Kim Doo-Sang;Lim Seung-Pyung
    • Progress in Superconductivity
    • /
    • v.7 no.1
    • /
    • pp.28-35
    • /
    • 2005
  • We propose a method to measure atrial arrhythmias (AA) such as atrial fibrillation (Afb) and atrial flutter (Afl) with a SQUID magnetocardiograph (MCG) system. To detect AA is one of challenging topics in MCG. As the AA generally have irregular rhythm and atrio-ventricular conduction, the MCG signal cannot be improved by QRS averaging; therefore a SQUID MCG system having a high SNR is required to measure informative atrial excitation with a single scan. In the case of Afb, diminished f waves are much smaller than normal P waves because the sources are usually located on the posterior wall of the heart. In this study, we utilize an MCG system measuring tangential field components, which is known to be more sensitive to a deeper current source. The average noise spectral density of the whole system in a magnetic shielded room was $10\;fT/{\surd}Hz(a)\;1\;Hz\;and\;5\;fT/{\surd}Hz\;(a)\;100\;Hz$. We measured the MCG signals of patients with chronic Afb and Afl. Before the AA measurement, the comparison between the measurements in supine and prone positions for P waves has been conducted and the experiment gave a result that the supine position is more suitable to measure the atrial excitation. Therefore, the AA was measured in subject's supine position. Clinical potential of AA measurement in MCG is to find an aspect of a reentry circuit and to localize the abnormal stimulation noninvasively. To give useful information about the abnormal excitation, we have developed a method, separative synthetic aperture magnetometry (sSAM). The basic idea of sSAM is to visualize current source distribution corresponding to the atrial excitation, which are separated from the ventricular excitation and the Gaussian sensor noises. By using sSAM, we localized the source of an Afl successfully.

  • PDF

Frontal Gamma-band Hypersynchronization in Response to Negative Emotion Elicited by Films (영상에 의해 유발된 부정적 감정 상태에 따른 전두엽 감마대역 신경동기화)

  • Kim, Hyun;Choi, Jongdoo;Choi, Jeong Woo;Yeo, Donghoon;Seo, Pukyeong;Her, Seongjin;Kim, Kyung Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.39 no.3
    • /
    • pp.124-133
    • /
    • 2018
  • We tried to investigate the changes in cortical activities according to emotional valence states during watching video clips. We examined the neural basis of two emotional states (positive and negative) using spectral power analysis and brain functional connectivity analysis of cortical current density time-series reconstructed from high-density electroencephalograms (EEGs). Fifteen healthy participants viewed a series of thirty-two 2 min emotional video clips. Sixty-four channel EEGs were recorded. Distributed cortical sources were reconstructed using weighted minimum norm estimation. The temporal and spatial characteristics of spectral source powers showing significant differences between positive and negative emotion were examined. Also, correlations between gamma-band activities and affective valence ratings were determined. We observed the changes of cortical current density time-series according to emotional states modulated by video clip. Gamma-band activities showed significant difference between emotional states for thirty seconds at the middle and the latter half of the video clip, mainly in prefrontal area. It was also significantly anti-correlated with the self-ratings of emotional valence. In addition, the gamma-band activities in frontal and temporal areas were strongly phase-synchronized, more strongly for negative emotional states. Cortical activities in frontal and temporal areas showed high spectral power and inter-regional phase synchronization in gamma-band during negative emotional states. It is inferred that the higher amygdala activation induced by negative stimuli resulted in strong emotional effects and caused strong local and global synchronization of neural activities in gamma-band in frontal and temporal areas.

Fabrication of the Plasma Focus Device for Advanced Lithography Light Source and Its Electro Optical Characteristics in Argon Arc Plasma (차세대 리소그래피 빛샘 발생을 위한 플라스마 집속 장치의 제작과 아르곤 아크 플라스마의 발생에 따른 회로 분석 및 전기 광학적 특성 연구)

  • Lee S.B.;Moon M.W.;Oh P.Y.;Song K.B.;Lim J.E.;Hong Y.J.;Yi W.J.;Choi E.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.15 no.4
    • /
    • pp.380-386
    • /
    • 2006
  • In this study, we had designed and fabricated the plasma focus device which can generate the light source for EUV(Extreme Ultra Violet) lithography. And we also have investigated the basic electrical characteristics of currents, voltages, resistance and inductance of this system. Voltage and current signals were measured by C-dot and B-dot probe, respectively. We applied various voltages of 1.5, 2, 2.5 and 3 kV to the anode electrode and observed voltages and current signals in accordance with various Ar pressures of 1 mTorr to 100 Torr in diode chamber. It is observed that the peak values of voltage and current signals were measured at 300 mTorr, where the inductance and impedance were also estimated to be 73 nH and $35 m{\Omega}$ respectively. The electron temperature has been shown to be 13000 K at the diode voltage of 2.5 kV and this gas pressure of 300 mTorr. It is also found that the ion density Ni and ionization rate 0 have been shown to be $N_i = 8.25{\times}10^{15}/cc$ and ${\delta}$= 77.8%, respectively by optical emission spectroscopy from assumption of local thermodynamic equilibrium(LTE) plasma.

Comparisons of lasing characteristics of InGaAs quantum-dot and quantum well laser diodes (InGaAs 양자점 레이저 다이오드와 양자우물 레이저 다이오드의 특성 비교)

  • Jung, Kyung-Wuk;Kim, Kwang-Woong;Ryu, Sung-Pil;Cho, Nam-Ki;Park, Sung-Jun;Song, Jin-Dong;Choi, Won-Jun;Lee, Jung-Il;Yang, Hae-Suk
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.5
    • /
    • pp.371-376
    • /
    • 2007
  • We have investigated the lasing characteristics of the InGaAs quantum dot laser diode (QD-LD) and InGaAs quantum well laser diode (QW-LD) operated at the 980 nm wavelength range. The 980-nm lasers are used as a pumping source for a erbium-doped fiber amplifier (EDFA) and it shows high efficiency in long-haul optical fiber network. We have compared the threshold current density, the characteristic temperature, the optical power and the internal efficiency of QD-LD and QW-LD under a pulsed current condition. The QD-LD shows superior performances to the QW-LD. Further optimization of a LD structure is expected to the superior performances of a QD-LD.