• Title/Summary/Keyword: sound-pressure-level(SPL)

Search Result 127, Processing Time 0.025 seconds

A Study on the Noise Reduction through the Control of Internal Flow for a Slim Type External ODD (슬림타입 외장형 ODD 내부의 유동 안정을 통한 소음저감에 관한 연구)

  • Lee, Woo-Jin;Seo, Jun-Ho;Rhim, Yoon-Chul
    • Transactions of the Society of Information Storage Systems
    • /
    • v.8 no.2
    • /
    • pp.72-77
    • /
    • 2012
  • The demand for the laptop computer has been increased day by day and most of users ask quiet computer and devices to work in comfortable environment. One of the devices which generate acoustic noise is an external ODD. Unlike the internal ODD, the external ODD is easy to emit noise because it runs outside of the computer and also it is packed with a thin plastic covers. As the disk rotates, vortex flow is generated inside of the cavity due to various and complicated mold parts of the cover. In addition, there is a gap between the disk tray and the upper/lower cases, through which the air flows as well as the noise leaks. In this study, we have proposed how to reduce the acoustic noise of an external ODD using numerical and experimental analysis. The pressure fluctuations and turbulent kinetic energy distributions are calculated for the developed model. The results show that the sound pressure level is reduced by 2.3dB through simple modifications of ribs of the top cover, which remove or suppress flow instabilities inside of the cavity.

Research on the characteristics of noise exposure on worker wearing acoustic devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.808-813
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset Noise exposure measurements of 17 operators were performed in 7 call centers and Head and Torso Simulator method in compliance with the ISO Standard 11904-2 was used for the measurement of noise transmitted from the headset Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of Pearson Correlation Analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

  • PDF

Research on the Characteristics and Measures of Noise Exposure on Worker Wearing Acoustic Devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.7
    • /
    • pp.615-621
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset. Noise exposure measurements of 17 operators were performed in 7 call centers and head and Torso simulator method in compliance with the ISO standard 11904-2 was used for the measurement of noise transmitted from the headset. Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of pearson correlation analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

Performance improvement of a quiet zone using multichannel real-time active noise control system (다채널 실시간 능동 소음제어 시스템을 이용한 정숙공간 성능개선)

  • Mu, Xiangbin;Ko, JinSeok;Rheem, JaeYeol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.3
    • /
    • pp.216-222
    • /
    • 2016
  • Generation of a quiet zone in noisy environment is undoubtedly of considerable realistic significance. This paper describes development and implementation of a multichannel real-time active noise control (ANC) system for 3 dimensional noisy environment to enhance the quiet zone performance in terms of size and noise cancellation gain. The proposed ANC system employes a multichannel delay-compensated filtered-X least mean square (FXLMS) algorithm; its real-time implementation is designed in TMS320C6713 digital signal processor (DSP) board. The system is evaluated for cancelling various tonal frequency noises in the range from 100 to 500 Hz, and the performance is then illustrated by measuring the quiet zone in terms of sound pressure level (SPL) attenuation. Experiment results show that a quiet zone of quiet with satisfactory size and maximum 24 dB noise attenuation is successfully generated.

Acoustic Transfer Characteristics of Ship′s Bridge for Whistle Sound (기적음에 대한 선박 선교의 음향전달특성)

  • Yim, Jeong-Bin;Kim, Chang-Kyoung
    • Journal of Navigation and Port Research
    • /
    • v.28 no.6
    • /
    • pp.491-496
    • /
    • 2004
  • The paper describes measurement techniques for an acoustic transfer characteristic of ship's bridge stimulated by a whistle sound The response sounds, according to the opening-shutting conditions of bridge doors for Training Ship ‘SAENURI’, are measured by B&K 2260D equipment, and then the frequency responses are extracted by B&K 7830 software. To evaluate the measured transfer characteristic, the 128th order FIR (Finite Impulse Response) filters, containing the different frequency characteristics, are constructed based on the frequency sampling-based design method Using evaluation indexes with six scales, psychological assessments by five subjects are carried out with test sounds which are obtained from convolving the source signal with FIR filters. As results of tests, the test sounds gives $A_S$ 3.3∼4.7 which means the psychological sense of ‘it is almost similar sound as original ones in a real world’, and thus it is clearly seen that the proposed method can be used for the measurement of an acoustic transfer characteristic of ship’s bridge.

Generation of Time Series Data from Octave Bandwidth SPL of Acoustic Loading Using Interpolation Method (보간법을 이용한 옥타브 밴드폭 음향 하중 SPL의 시계열 데이터 생성)

  • Go, Eun-Su;Kim, In-Gul;Jeon, Minhyeok;Cho, Hyun-Jun;Park, Jae-Sang;Kim, Min-Sung
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.1-11
    • /
    • 2021
  • Thermal protection system structures such as double-panel structures are used on the skin of the fuselage and wings to prevent the transfer of high heat into the interior of an high supersonic/hypersonic aircraft. The thin-walled double-panel skin can be exposed to acoustic loads by high power engine noise and jet flow noise, which can cause sonic fatigue damage. In order to predict the fatigue life of the skin, the octave bandwidth SPL should be calculated as narrow bandwidth PSD or acoustic load history using interpolation method. In this paper, a method of converting the octave bandwidth SPL acoustic load into a narrow bandwidth PSD and reconstructed acoustic load history was investigated. The octave bandwidth SPL was converted to the narrow bandwidth PSD using various interpolation methods such as flat, log and linear scale, and the probabilistic characteristics and fatigue damage results were compared. It was found that average error of fatigue damage index by the log scale interpolation method was relatively small among three methods.

FEM vibroacoustic analysis in the cabin of a regional turboprop aircraft

  • Cinefra, Maria;Passabi, Sebastiano;Carrera, Erasmo
    • Advances in aircraft and spacecraft science
    • /
    • v.5 no.4
    • /
    • pp.477-498
    • /
    • 2018
  • The main goal of this article is to validate a methodological process in Actran MSC Software, that is based on the Finite Element Method, to evaluate the comfort in the cabin of a regional aircraft and to study the noise and vibrations reduction through the fuselage by the use of innovative materials. In the preliminary work phase, the CAD model of a fuselage section was created representing the typical features and dimensions of an airplane for regional flights. Subsequently, this model has been imported in Actran and the Sound Pressure Level (SPL) inside the cabin has been analyzed; moreover, the noise reduction through the fuselage has been evaluated. An important investigation and data collection has been carried out for the study of the aircraft cabin to make it as close as possible to a real problem, both in geometry and in materials. The mesh of the structure has been built from the CAD model and has been simplified in order to reduce the number of degrees of freedom. Finally, different fuselage configurations in terms of materials are compared: in particular, aluminum, composite and sandwich material with composite skins and poroelastic core are considered.

Damping Characteristic of Helmholtz Resonator according to Its Geometry and Sound Pressure Level (헬름홀쯔 공명기의 기하학적 형상과 가진 음압에 따른 감쇠 특성)

  • Song, Jae-Kang;Kim, Ki-Woo;Chae, Byoung-Chan;Ko, Young-Sung;Kim, Sun-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.10
    • /
    • pp.966-972
    • /
    • 2010
  • Damping characteristics of a Helmholtz resonator to passively control the combustion instability were investigated by linear acoustic analysis and atmospheric acoustic tests. Its orifice length and diameter were selected as the design parameters and supplied SPL(sound pressure level) effect on damping characteristics were investigated. Damping capacity is improved by decreasing the orifice length as well as by increasing the orifice diameter. Also, the results showed that the damping capacity of the resonator decreased nonlinearly about above 110 dB and instabilities in the nonlinear region were more effectively suppressed by increasing the orifice diameter.

Effect of the Inter-aural Level Differences on the Speech Intelligibility Depending on the Room Absorption in Classrooms (실내 흡음에 따른 양이간 음량차가 강의실의 음성명료도에 미치는 영향)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.4
    • /
    • pp.335-345
    • /
    • 2013
  • The present study investigates the effect of the inter-aural level difference(ILD) on the syllable articulation test in classrooms which can be occurred by the absorption of interior surfaces. In order to do this, the sound absorbing materials were installed in the classroom and sound pressure level(SPL) at each ear was measured using binaural recording systems. Also, syllable articulation tests were carried out at a classroom with and without sound absorption materials by 20 students who have normal hearing condition, in order to investigates the effect of the ILD on the speech intelligibility. As a result, it was found that the larger inter-aural level differences was occurred at the nearer positions to lateral walls after sound absorptions were applied to lateral walls in the classroom. At some places, the measured ILD was lager than JND of sound level (3dB). Also, it was shown that the correlation coefficient of inter-aural level difference with the score of syllable test has the significant result(-0.441). Thus, It is concluded that ILD can affect the subjective speech intelligibility in classrooms.

Flow-field Analysis and Noise Prediction of Centrifugal Compressor (원심압축기 유동해석 및 소음예측에 관한 연구)

  • 선효성;신인환;이수갑
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1005-1009
    • /
    • 2002
  • The objective of this research is to suggest the noise prediction method of the centrifugal compressor. It is focused on the Blade Passing Frequency (BPF) component which is regarded as the main part of the rotating impeller noise. Euler solver is used to simulate the flow-field of the centrifugal compressor and time-dependent pressure data are calculated to perform the near-field noise prediction by Ffowcs Williams-Hawkings (FW-H) formulation. Indirect Boundary Element Method (IBEM) is applied to consider the noise propagation effect. Pressure fluctuations of the inlet and the outlet in the centrifugal compressor impeller are presented and Sound Pressure Level (SPL) prediction results are compared with the experimental data.

  • PDF